| Brand | Granutools |
|---|---|
| Origin | Belgium |
| Model | Granudrum |
| Sample Capacity | 50 mL (max), 10 mL (min) |
| Measurable Parameter | Dynamic Cohesion Index & Flow Angle |
| Rotation Speed Range | 2–60 rpm |
| Measurement Principle | Rotating Drum Imaging with CCD-Based Interface Analysis |
| Compliance | Designed for GLP/GMP-aligned workflows, supports audit-trail-capable data export |
| Brand | Granutools |
|---|---|
| Origin | Belgium |
| Model | Granuflow |
| Sample Capacity | 500 mL (max), 50 mL (min) |
| Measurable Parameters | Flow Rate Index, Beverloo Curve |
| Orifice Array | 7 calibrated circular orifices (1–38 mm diameter) |
| Measurement Principle | Gravimetric mass-flow vs. time slope analysis |
| Compliance | ASTM B213, ISO 4490, USP <1174> |
| Reproducibility | ±2% RSD |
| Measurement Duration | <5 min per test |
| Data Output | Cb (Beverloo flow index), Dmin (minimum orifice diameter), mass flow rate (g/s) |
| Brand | Granutools |
|---|---|
| Origin | Belgium |
| Model | Granuheap |
| Instrument Type | Powder Heap Angle Analyzer |
| Measurable Parameter | Angle of Repose |
| Maximum Sample Vessel Capacity | 8 mL |
| Minimum Sample Volume | 4–8 mL |
| Automation Level | Fully Automated |
| Measurement Principle | Image-based heap geometry analysis with rotational multi-angle imaging |
| Brand | Granutools |
|---|---|
| Origin | Belgium |
| Model | Granupack |
| Sample Capacity | 40 mL (max), 10 mL (min) |
| Measurable Parameters | Bulk Density, Tapped Density, Hausner Ratio, Compaction Curve |
| Measurement Accuracy | ±0.4% for metallic powders, ±0.6% for pharmaceutical excipients |
| Drop Height Options | ΔZ = 1 mm or 3 mm |
| Compliance | European Pharmacopoeia (Ph. Eur. 2.9.34) |
| Brand | GREATEK |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GT-E220 |
| Price | USD 32,500 (FOB Guangdong) |
| Imaging Method | Optical Rigid Endoscope |
| Camera Resolution | 640 × 480 (0.31 MP effective, 720p-equivalent progressive scan output) |
| Display | 6.5-inch capacitive touchscreen (1280 × 720 IPS LCD) |
| Measurement Modes | Point-to-Point, Point-to-Line, Point-to-Plane, Curvilinear Distance |
| Real-time 3D Reconstruction | Binocular stereo photogrammetry with sub-pixel disparity matching |
| Battery | Removable 7800 mAh Li-ion pack (typ. 4.5 h continuous operation) |
| Data Export | USB 2.0 mass storage mode, FAT32-formatted U disk support |
| Compliance | T/CECS 683–2020, JGJ/T 485–2019, DB37/T 5106–2018, DG/TJ 08–2252–2018, DB13(J)/T 8327–2019, DB32/T 3754–2020, DBJ/T–199–2020, DB22/T 5037–2020, DBJ52/T105–2021 |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | GTM- |
| Price Range | USD 1,400 – 2,800 |
| Load Capacity Options | 0–5 kN, 0–10 kN, 0–20 kN, 0–50 kN |
| Measurement Accuracy | ±0.15% FS (Load), ±0.5% FS (Deformation) |
| Deformation Range | ±5 mm |
| Displacement Rate | 0–1 mm/min (adjustable) |
| Temperature Capability | GTM-1 — Ambient only |
| Sample Dimension Tolerance | Parallelism ≤0.02 mm, Perpendicularity ≤0.02 mm, Surface Roughness Rz ≤1.60 µm |
| Strain Gauge Length Limits | ≤1 mm (3-point bend), ≤5 mm (4-point bend) |
| Compliance Standards | GB/T 10700–2006, GB/T 6569, GB/T 1182, GB/T 1031 |
| Brand | Guance |
|---|---|
| Origin | Beijing, China |
| Model | GCYZS-75A |
| Measurement Range | 0–100% O₂ |
| Resolution | 0.1% O₂ |
| Accuracy | ±0.4% O₂ |
| Response Time | <10 s |
| Display Precision | 0.1% ±1 digit |
| Drift | <3% per year |
| Combustion Tube ID | 90 mm, Length: 480 mm |
| Gas Flow Velocity in Tube | 40 ±10 mm/s |
| Chamber Temperature Control | 23 ±2 °C |
| Ignition Flame Length | 5–50 mm (adjustable) |
| Power Supply | 220 V ±15%, 50 Hz, 100 W |
| Operating Pressure | 0.1 MPa |
| Input Pressure Range | 0.25–0.4 MPa |
| Gas Requirements | Industrial-grade O₂ (GB/T 3863) and N₂ (GB/T 3864), each with pressure regulator (user-supplied) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FTDZ-I |
| Price | USD 2,150 (FOB Beijing) |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Domestic (China) |
| Model | GCGEST-121C+ |
| Pricing | Upon Request |
| Resistance Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V |
| Accuracy | ±1% (≤1×10¹⁰ Ω), ±5–10% (>1×10¹⁰ Ω) |
| Display | Dual-line LCD (simultaneous V, R, I) |
| Power Supply | 220 V AC / 50 Hz |
| Power Consumption | 100 W |
| Dimensions (L×W×H) | 300 mm × 300 mm × 150 mm |
| Weight | ~5 kg |
| Standard Electrode | 2.5 kg, 63 mm diameter |
| Compliance | SJ/T 11294–2018 Annex A (ESD Floor Coating Testing) |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCPMFY-A |
| Price | USD 1,700 (approx.) |
| Touchscreen | 7-inch capacitive HMI |
| Measurement Principle | Controlled compression-deformation-relaxation cycle with laser-displacement tracking and load-cell feedback |
| Compression Speed | (1000 ± 100) mm/min |
| Platen Diameter | 203 mm |
| Support Plate Perforation | Ø6.5 mm, 20 mm pitch |
| Sample Dimensions | 380 × 380 × 100 mm |
| Initial Preload Force | 4.5 N |
| Deformation Target | 75% of initial thickness |
| Dwell Time | 60 s |
| Recovery Threshold | Re-engagement of 4.5 N preload force |
| Time Resolution | 0.01 s |
| Thickness Measurement Accuracy | ±1 mm |
| Load Cell Capacity | 1000 N |
| Compliance | GB/T 26392–2011, ASTM D3574–2008 Section 12 (Recovery Time for Slow-Recovery Foams) |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NDH-B3 |
| Instrument Type | Electronic Universal Testing Machine |
| Arc On/Off Time Accuracy | < ±1 ms |
| Voltage Regulation Capacity | 3 kVA |
| High-Voltage Transformer Capacity | 3 kVA, 0–20 kV Output |
| Rated Test Voltage | 12.5 kV |
| Voltage Accuracy | ±1% |
| Current Control Accuracy | ±3% |
| Current Measurement Accuracy | ±1.5% |
| Electrode Force on Specimen | (0.5 ± 0.05) N |
| Electrode Material | Tungsten Rod |
| Electrode Spacing | (6.35 ± 0.1) mm (IEC), (6.0 ± 0.1) mm (ASTM) |
| Ambient Temperature | (23 ± 2) °C |
| Ambient Humidity | (50 ± 5)% RH |
| Input Power | 220 V AC / 50 Hz |
| Output Voltage Range | 0–17.5 kV AC |
| Test Current Settings | 10, 20, 30, 40 mA |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMQS-I.2 |
| Price | USD 2,250 (FOB Beijing) |
| Power Supply | 220 V AC / 50 Hz |
| Vertical Travel Range | 0–800 mm |
| Optical Sensor Accuracy | ±1 mm |
| Optical Sensor Range | 10–1000 mm |
| Temperature Probe Range | 0–500 °C (Accuracy: ±0.5% FS) |
| Pressure Sensor Range (Optional) | 0–500 N |
| Sample Cup ID | 100 mm |
| Sample Cup Height | 200 mm |
| Brand | GuanCe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMPL-2000A4 |
| Max Test Force | 0–1000 N |
| Frequency Range | 10–100 cycles/min (Standard Compliance: 70 ± 5 cycles/min) |
| Machine Weight | 100 kg |
| Platen Diameter | Ø250 ± 1 mm (Edge Radius: R25 ± 1 mm) |
| Specimen Support Table | 500 × 500 × 10 mm (Perforated, 6.35 mm holes on 20 mm centers) |
| Specimen Dimensions | 500 × 500 × (50 ± 2) mm |
| Drive System | Servo Motor |
| Control Interface | 7-inch Color Touchscreen HMI |
| Control Unit | Siemens PLC |
| Test Modes | Constant-Load Mode / Thickness-Reduction Percentage Mode |
| Max Cycles | >100,000 |
| End-of-Test Alert | Audible Alarm + Auto-Return to Home Position |
| Power Supply | 220 VAC / 50 Hz |
| Footprint | 800 × 500 × 1200 mm (L × W × H) |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Model | CaBER 1 |
| Motor Type | Linear Motor |
| Hencky Strain (ε₀) | 10 |
| Applied Strain Rate Range | 0.01–300 s⁻¹ |
| Fluid Strain Rate Range | 10⁻⁵–10 s⁻¹ |
| Shear Viscosity Range | 10–10⁶ mPa·s |
| Plate Diameter | 4–8 mm (standard: 6 mm) |
| Temperature Range | 0–80 °C |
| Filament Diameter Resolution | 10 µm |
| System Response Time | 10 ms |
| Dimensions | 40 × 34 × 60 cm |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Model | Mars 40 |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air-bearing (2 radial + 1 axial) |
| Minimum Rotational Speed | 1×10⁻⁷ rpm |
| Maximum Rotational Speed | 4500 rpm |
| Frequency Range | 1×10⁻⁶ – 100 rad/s |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Angular Displacement Resolution | 12 nrad |
| Motor Inertia | 1×10⁻⁵ kg·m² |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Model | MARS III |
| Minimum Torque | 0.003 µN·m |
| Maximum Torque | 200 mN·m |
| Torque Resolution | 0.1 nN·m |
| Angular Displacement Resolution | 0.012 µrad |
| Motor Inertia | 10 µN·m·s² |
| Minimum Rotational Speed | 1.0×10⁻⁸ rpm |
| Maximum Rotational Speed | 1500 rpm (4500 rpm optional) |
| Minimum Oscillation Frequency | 1.0×10⁻⁶ Hz |
| Maximum Oscillation Frequency | 100 Hz |
| Normal Force Range | 0.01–50 N |
| Normal Force Resolution | 0.001 N |
| Temperature Control Range (Peltier) | −60 to 200 °C |
| Temperature Control Range (Electric Heater) | 30 to 300 °C |
| Temperature Control Range (Liquid Circulator) | −40 to 180 °C |
| Temperature Control Range (CTC Radiation/Convection Furnace) | −150 to 600 °C |
| Bidirectional Normal Force Measurement | Yes |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Model | MiniLab II |
| Instrument Type | Torque Rheometer |
| Screw Configuration | Co-rotating and Counter-rotating Conical Twin-Screw |
| Minimum Speed | 1 rpm |
| Maximum Speed | 360 rpm |
| Frequency Range | 0.1–37.7 rad/s |
| Maximum Torque | 300 N·m |
| Torque Resolution | 0.1 N·m |
| Motor Power | 400 W |
| Barrel Volume | 7 cm³ (≈5 g PE) |
| Max Temperature | 350 °C (optional 420 °C) |
| Max Pressure | 200 bar |
| Barrel Material | Stainless Steel (HRC55) |
| Screw Material | Stainless Steel 1.4122 |
| Cooling | Air/Water (350 °C version), Air-only (420 °C version) |
| Flow Path | Integrated Recirculation Channel with Automated Bypass Valve |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Laboratory-Scale Co-Rotating Twin-Screw Extruder |
| Screw Diameter | 11 mm |
| L/D Ratio | 40:1 |
| Drive Power | 1.25 kW |
| Speed Range | 10–1000 rpm (infinitely variable) |
| Max Operating Pressure | 100 bar (with integrated safety monitoring) |
| Temperature Range | Ambient to 350 °C (optional up to 450 °C) |
| Barrel Zones | 8 (1 cooling feed zone + 7 independently heated zones) |
| Footprint | 82 × 48 × 34 cm (L × W × H) |
| Throughput | Up to 2.5 kg/h |
| Minimum Sample Requirement | ~20 g |
| Screw Design | Modular, segmentable for customizable configuration |
| Barrel Configuration | Horizontally split, top barrel section removable |
| Control Interface | Integrated color touchscreen |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Benchtop Controlled-Stress/Controlled-Rate Rotational Rheometer |
| Model | RS 1 |
| Drive System | Air-bearing motor |
| Minimum Rotational Speed | 1.0 × 10⁻³ rpm |
| Maximum Rotational Speed | 1200 rpm |
| Angular Frequency Range (Oscillatory Mode) | 1.0 × 10⁻⁴ – 100 rad/s |
| Maximum Torque | 100 mN·m |
| Torque Resolution | 5 nN·m |
| Angular Displacement Resolution | 0.012 µrad |
| Motor Inertia | 11 µN·m·s² |
| Normal Force Range | Not specified |
| Normal Force Resolution | Not specified |
| Temperature Control Options | Peltier (–40 to +180 °C), Electric Heating (+20 to +200 °C), Liquid Circulator (–40 to +180 °C) |
| Optional Accessories | Star Geometry, SHRP Asphalt Testing System, Anti-Slip System |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Model | RS6000 |
| Motor Technology | 4th-generation vector-controlled motor |
| Torque Range | 0.005 µN·m (min) to 200 mN·m (max) |
| Torque Resolution | 0.5 nN·m |
| Angular Displacement Resolution | 0.012 µrad |
| Rotational Speed Range | 1.0×10⁻⁷ – 1500 rpm (up to 4500 rpm optional) |
| Oscillation Frequency Range | 1.0×10⁻⁵ – 100 Hz |
| Normal Force Range | ±0.01–50 N |
| Normal Force Resolution | 0.001 N |
| Temperature Control | Peltier (−60 to 200 °C), Electric Heater (30 to 300 °C), Liquid Circulator (−40 to 180 °C) |
| Data Acquisition Rate | 2.5 ms per point |
| Compliance | ASTM D4402, ISO 6721-10, ISO 3219, USP <911>, FDA 21 CFR Part 11-ready software architecture |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Instrument Type | Rotational Viscometer / Compact Rheometer |
| Model | VT iQ |
| Viscosity Range | 0.001 – 600,000 Pa·s |
| Angular Velocity Range | 0.001 – 157 rad/s |
| Torque Range | 0.2 – 100 mN·m |
| Shear Stress Range | 0.7 – 63,660 Pa |
| Shear Rate Range | 0.004 – 11,415 s⁻¹ |
| Temperature Control | Peltier (–5 °C to 160 °C, depending on geometry) and Liquid Circulator (–20 °C to 180 °C) |
| Connectivity | USB, TCP/IP, USB flash drive interface for RheoApp, keyboard & barcode scanner ports |
| Dimensions (W × L × H) | 270 × 500 × 500 mm |
| Weight | 18 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Model | VT1 Plus / VT2 Plus |
| Instrument Type | Battery-Powered Rotational Viscometer |
| Viscosity Range | VT1 Plus: 1.5–330 mPa·s |
| VT2 Plus | 0.3–4000 dPa·s |
| Temperature Capability | Up to 150 °C |
| Rotational Speed | 62.5 rpm |
| Repeatability | ±1% of Full Scale Deflection (FSD) |
| Standard Accuracy | ±5% FSD |
| Display | Digital LCD |
| Power | 4 × AA batteries (included), with optional charger |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Instrument Type | Rotational Viscometer |
| Model | VT550 |
| Measurement Principle | Searle (rotating spindle) geometry |
| Viscosity Range | 2–10⁷ mPa·s |
| Speed Range | 0.5–800 rpm |
| Torque Range | 0.1–50 mN·m (up to 400 rpm) |
| Temperature Range | −40 °C to +350 °C (with external temperature control unit) |
| Compliance Standards | ISO 2555, ISO 3219, DIN 53018, DIN 53019 |
| Operating Modes | Controlled Rate (CR), Controlled Deformation (CD) |
| Predefined Protocols | 10 factory-programmed routines |
| Display | Integrated LCD with digital readout |
| Output | Real-time digital display and optional thermal printout |
| Brand | Aerospace Vertical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HAG-Type |
| Price Range | USD 6,000 – 10,000 (FOB) |
| Application | Halogen acid gas quantification in flame-retardant cables |
| Sample Form | Solid wire & cable specimens |
| pH Repeatability | ±0.02 pH units |
| Combustion Boat | Fused quartz tube, 100 mm × 25 mm × 10 mm (L × W × D) |
| Air Filtration | Activated carbon + silica gel dual-stage drying & purification |
| Thermocouple | K-type, 0–1300 °C, stainless-steel sheathed |
| Heating Furnace | 600 mm effective length × Ø42 mm ID, 10 kW electric heating, PID-controlled |
| Gas Collection | Dual 500 mL absorption flasks |
| Air Flow Control | 20–200 mL/min adjustable rotameter |
| Power Supply | 220 V AC, 30 A |
| Conductivity Range | 0–1×10⁵ µS/cm |
| pH Measurement Range | 0–14, resolution 0.01 pH |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-5078 Verticality Deviation Tester |
| Pricing | Available Upon Request |
| Sample Diameter Range | 3–55 mm (4-jaw chuck, standard grip), 55–145 mm (reverse grip) |
| Chuck Type | Selectable 3-jaw or 4-jaw self-centering chuck |
| Measurement Range | 0–12.7 mm |
| Resolution | 0.001 mm |
| Indication Error | ±0.005 mm |
| Measurement Uncertainty | ≤ 0.05 mm (5 µm) |
| Adjustable Height Range | 5–400 mm |
| Positioning Mechanism | Universal adjustable bracket with multi-axis freedom |
| Data Output | USB/RS232 interface for real-time export to Excel or Word (optional) |
| Dimensions (L×W×H) | 330 × 240 × 240 mm |
| Net Weight | 20 kg |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HD-5079 |
| Price | Upon Request |
| Torque Range | 20 N·m (40 N·m optional) |
| Accuracy Class | Class 1 |
| System Resolution | 0.001 N·m |
| Clamp Diameter Range | Φ5 mm to Φ170 mm |
| Sample Count per Batch | 1–9 units |
| Power Supply | 220 V, 50 Hz |
| Weight | 15 kg |
| Compliance Standards | GB/T 17876, ASTM D 2063, ASTM D 3198, ASTM D 3474 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-5080 Bottle Wall Thickness Gauge |
| Pricing | Upon Request |
| Measurement Range | 0–12.7 mm |
| Resolution | 0.001 mm |
| Sample Diameter | 15–200 mm (customizable) |
| Sample Height | ≤300 mm (customizable) |
| Dimensions (W×D×H) | 400 × 220 × 500 mm |
| Weight | 10 kg |
| Display | LCD digital indicator |
| Data Output | USB/RS232 interface for Excel and Word export (optional) |
| Compliance Standards | QB/T 2665–2004, QB/T 2357–1998, QB/T 1868–2004 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HD-5081 |
| Quotation | Available Upon Request |
| Sample Diameter Range | φ20–160 mm |
| Sample Height Adjustment | 20–180 mm |
| Impact Energy Range | 0–2.9 N·m |
| Dimensions (L×W×H) | 500 × 350 × 700 mm |
| Weight | 28 kg |
| Compliance Standards | GB/T 6552–2015, YBB00382004–2015 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HAIDA HD-5083 Vacuum Leak Tester |
| Price | Upon Request |
| Pressure Range | 0 to –90 kPa |
| Accuracy Class | 2.5 |
| Control Method | Manual Pressure Adjustment & Hold |
| Display | Analog Pressure Gauge |
| Air Supply Requirement | 0.7 MPa (User-Supplied) |
| Air Inlet | Φ6 mm Polyurethane Tubing |
| Vacuum Chamber Dimensions (Standard) | Φ270 × 210 mm (H) |
| Overall Dimensions (Main Unit) | 420 × 320 × 130 mm (L×W×H) |
| Seal Chamber Dimensions | Φ300 × 350 mm (H) |
| Net Weight | 12 kg |
| Compliance Standards | GB/T 15171, ASTM D3078 |
| Brand | HAIDA INTERNATIONAL |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HAIDA HD-5085 Film Dart Impact Tester |
| Pricing | Upon Request |
| Test Methods | ASTM D1709, ISO 7765-1:1988, GB/T 9639.1–2008, JIS K7124-1 |
| Drop Height | A-method 0.66 ± 0.01 m / B-method 1.50 ± 0.01 m |
| Dart Tip Diameter | A-method 38 ± 1 mm / B-method 50 ± 1 mm |
| Mass Range | A-method 50–2000 g, B-method 300–2000 g |
| Mass Resolution | 0.1 g |
| Pneumatic Pressure Requirement | 0.6 MPa |
| Specimen Size | >150 mm × 150 mm |
| Interface | RS232 serial port, built-in thermal printer |