Physical Property Testing Instruments
Filter
Showing 1831–1860 of 4517 results
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,500 (FOB) |
| Internal Chamber Dimensions | Φ25×40 cm / Φ30×50 cm / Φ40×60 cm / Φ50×70 cm |
| Temperature Range | 100–132 °C |
| Humidity Condition | 100 % RH saturated steam |
| Pressure Range | 0–4 kgf/cm² above atmospheric pressure |
| Temperature Control Accuracy | ±0.1 °C (PID-controlled digital LED controller) |
| Safety Features | Dual overheat protection, interlocked door switch, automatic pressure relief valve, ABS thermal-insulated door, integrated silicone gasket, auto-water replenishment, unsaturated steam purge system |
| Brand | OEM / Custom Brand Available |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 13,500 (FOB) |
| Internal Chamber Dimensions | Ø350 × 500 mm (cylindrical) |
| Internal Material | SUS304 stainless steel |
| External Material | Powder-coated steel |
| Temperature Range | RT+10°C to 132°C (saturated steam) |
| Humidity Range | 75–100% RH (saturation-controlled) |
| Pressure Range | 0.00–2.90 kg/cm² gauge (max vessel rating: 3.5 kg/cm²) |
| Test Duration | 0–999 hours (programmable) |
| Temperature Uniformity | ±1.0°C |
| Ramp-up Time (RT→132°C) | ≤60 min |
| Pressurization Time (0→2.0 kg/cm²) | ≤50 min |
| Vacuum Preconditioning | Integrated particulate-filtered air purge (<1 µm filtration) |
| Water Autonomy | Up to 200 h per fill (optional fully automated补水 system available) |
| [Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,500 (approx.) |
| Internal Chamber | Ø300 × 450 mm (cylindrical) |
| External Dimensions | 660 × 950 × 600 mm (W×H×D) |
| Interior Material | SUS304 Stainless Steel |
| Exterior Finish | Powder-Coated Steel |
| Temperature Range | 100–132°C |
| Humidity | 100% RH (saturated steam) |
| Pressure Range | 0.0–3.0 kg/cm² absolute (max. safety rating: 3.0 kg/cm² gauge = 1 atm + 2.0 kg/cm²) |
| Time Range | 0–1000 h |
| Temp. Uniformity | ±2.0°C at 100°C |
| Temp. Accuracy | ±0.5°C |
| Temp. Resolution | 0.1°C |
| Pressure Accuracy | ±0.15 kg/cm² |
| Heating Rate | RT to 121°C in ≤35 min |
| Pressurization Rate | 0.0 to 1.0 kg/cm² in ≤35 min |
| Control System | Microprocessor-based PID + SSR with LED display for temperature/time |
| Sensor | PT-100 RTD (Class A) |
| Heating Element | Insulated high-voltage resistant sheathed heater |
| Air Circulation | Natural convection of saturated steam] |
| Brand | Generic |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,000 (FOB) |
| Internal Dimensions (HAST-25) | Ø250 × 450 mm |
| Internal Dimensions (HAST-35) | Ø350 × 500 mm |
| Temperature Range | RT to 132°C |
| Humidity Range | 75–100% RH |
| Pressure Range | 0.0–2.8 kg/cm² (gauge), max safe capacity 4.0 kg/cm² |
| Temperature Uniformity | ±1.5°C |
| Temperature Control Accuracy | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Pressurization Time (0 → 2.0 kg/cm²) | ~30 min |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Casing | SECC steel with electrostatic powder coating |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 13,500 (FOB) |
| Internal Dimensions | Ø250 × 400 mm |
| External Dimensions | W560 × H1000 × D650 mm |
| Temperature Range | +100°C to +132°C |
| Relative Humidity | 100% RH (saturated steam) |
| Control System | Microprocessor-based PID controller with LED display, SSR output |
| Temperature Sensor | Pt100 platinum resistance thermometer |
| Heating | Stainless steel finned heater |
| Humidification | Electric surface-evaporation type with drain port |
| Inner Chamber Material | SUS#304 mirror-finish stainless steel |
| Outer Cabinet | SUS#304 stainless steel with electrostatic powder coating |
| Safety Protections | Fuseless overcurrent protection, compressor overload protection, overtemperature cut-off, low-water level alarm, dry-heater burnout prevention, fast-acting thermal fuse |
| Power Supply | 1Φ 220 V, 8 A, 50 Hz ±10% |
| Water Requirement | RO-purified or distilled water |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pressure Range | 0–6 kg/cm² (0–0.6 MPa) |
| Operating Pressure | 2.0 kg/cm² (≈200 kPa gauge) |
| Temperature Range | +100°C to +132°C (saturated steam) |
| Humidity Range | 75–100% RH (saturated vapor) |
| Temperature Control Accuracy | ±0.5°C |
| Time Setting Range | 0.00–999.99 hours |
| Chamber Structure | Horizontal cylindrical test chamber with vacuum-assisted air purge |
| Compliance | ASTM D2244, IEC 60068-2-66, JIS C 60068-2-66, MIL-STD-202, ISO 16750-4, UL 746, NACE TM0177, CNS 12527, BS EN 60068-2-66 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 13,500 (FOB) |
| Internal Dimensions | Ø250 × 400 mm |
| External Dimensions | W560 × H1000 × D650 mm |
| Temperature Range | +100°C to +132°C |
| Humidity Range | 75–100% RH |
| Control System | Microprocessor-based PID controller with LED display |
| Temperature Sensor | Pt100 Platinum Resistance Thermometer |
| Heating | Stainless Steel Finned Heater |
| Humidification | Electric Surface Evaporation System |
| Chamber Material | Interior – Mirror-Finish SUS#304 Stainless Steel |
| Safety Protections | Fuseless Overload Protector, Compressor Overcurrent Protector, Overtemperature Cut-off, Low-Water Level Detection, Dry-Run Protection for Heater/Humidifier, Fast-Acting Thermal Fuse |
| Power Supply | 1φ 220 V, 8 A, 50 Hz ±10% |
| Water Requirement | RO Purified or Distilled Water |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,000 (FOB) |
| Internal Dimensions (Ø × H) | Φ250×300 mm to Φ650×600 mm |
| External Dimensions (W×H×D) | 500×500×700 mm to 950×900×1100 mm |
| Operating Temperature Range | 105–135 °C (143 °C optional) |
| Relative Humidity Range | 70–100 % RH |
| Saturation Pressure Range | 0.0–2.0 kg/cm² (gauge) — up to 3.0 kg/cm² on request |
| Power Supply | AC 220 V / 380 V, 50/60 Hz |
| Safety Systems | Low-water cutoff, overpressure relief, auto/manual water replenishment, automatic steam venting |
| Standard Accessories | Two stainless-steel shelves |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,000 (FOB) |
| Brand | OEM / Custom Manufacturer |
|---|---|
| Origin | China (Manufactured in Wuhan) |
| Supplier Type | Authorized Distributor |
| Import Status | Imported Components |
| Price | USD 4,050 (FOB Wuhan) |
| Temperature Range | 110°C / 132°C (saturated steam) |
| Humidity Range | 100% RH (saturation) |
| Pressure Range | 0.5–2.0 kg/cm² (max safety capacity: 3.5 kg/cm²) |
| Test Duration | 0–999 h (adjustable) |
| Temperature Uniformity | ±2.0°C |
| Heating Rate | RT to 132°C in ≤35 min (at control point) |
| Pressurization Rate | 0.0 to 2.0 kg/cm² in ≤40 min (at control point) |
| Temperature Control Accuracy | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Controller | Microprocessor-based PID with SSR output |
| Compliance | ASTM F1876, IEC 60068-2-66, JIS C 60068-2-66, ISO 16750-4, MIL-STD-883 Method 1008.8, UL 1577, NACE TM0177, CNS 12403 |
| Brand | OEM / Custom Manufacturer |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 14,200 (FOB) |
| Internal Chamber Dimensions | Ø300 × 450 mm (D × H) |
| External Dimensions | 660 × 950 × 600 mm (W × H × D) |
| Internal Material | SUS316 Stainless Steel or Epoxy-Coated Steel |
| Temperature Resolution | 0.1 °C |
| Pressure Control Range | 0–4 kg/cm² (0–392 kPa) |
| Operating Pressure Range | 1.0–2.5 kg/cm² (98–245 kPa) |
| Saturation Steam Temperature Range | Up to 143 °C at 2.5 kg/cm² |
| Pressure Accuracy | ±0.2–1.5 kg/cm² |
| Heating Method | Insulated High-Voltage Nichrome Heater with PID + SSR Control |
| Air Circulation | Natural Convection of Saturated Steam |
| Compliance | ASTM B117, IEC 60068-2-66, JIS C 60068-2-66, MIL-STD-202G, ISO 9001, UL 61010-1, NACE TM0177 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | +105.0°C to +142.9°C |
| Humidity Range | 75–100% RH |
| Temperature Stability | ±0.5°C |
| Humidity Stability | ±3% RH |
| Temperature Uniformity | ±1.0°C |
| Pressure Range | 0.2–2.0 kg/cm²G (Optional: 0.2–4.0 kg/cm²G) |
| Ramp Time | ~120 min (from ambient to 140°C) |
| Internal Chamber Dimensions | Ø45×45 cm or Ø65×60 cm |
| Construction Material | Inner & Outer Chamber – SUS316 Stainless Steel (Body), SUS304 Stainless Steel (Exterior Casing) |
| Power Supply | 1φ 220V 60Hz / 3φ 380V 50Hz, 20A |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 13,500 (FOB) |
| Internal Dimensions (Ø × H) | Φ250×300 mm to Φ650×600 mm |
| External Dimensions (W×H×D) | 500×500×700 mm to 950×900×1100 mm |
| Operating Temperature Range | 105–135 °C (143 °C optional) |
| Relative Humidity Range | 70–100 % RH |
| Steam Pressure Range | 0–2.0 kg/cm² (gauge), up to 3.0 kg/cm² on special order |
| Power Supply | AC 220 V / 380 V, 50/60 Hz |
| Safety Features | Dual overheat protection, door interlock, pressure relief valve, low-water cutoff, automatic steam purge, auto-fill and manual drain functions |
| Compliance | Designed per JESD22-A110, JEDEC Standard for HAST |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | +100°C to +132°C |
| Temp. Uniformity | ±1.5°C |
| Temp. Stability | ±0.5°C |
| Humidity Range | 75–100% RH (Saturated Steam) |
| Humidity Uniformity | ±3.0% RH |
| Humidity Stability | ±1.5% RH |
| Pressure Range | 0–4 kg/cm² (gauge), with operating range 1.0–3.0 kg/cm² |
| Max. Safety Pressure Capacity | 4 kg/cm² (≈490 kPa gauge, equivalent to ~5 atm absolute) |
| Test Duration | 0–999 hours |
| Pressurization Time | ~45 min (0 → 2.00 kg/cm²) |
| Heating Time | ~10 min (+100°C → +132°C, no-load, air temperature average) |
| Circulation Method | Natural convection of saturated steam |
| Control System | Microprocessor-based PID controller with PT-100 RTD sensing, LED time display, analog pressure gauge, and manual water inlet valve with auto-refill capability |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Internal Chamber Dimensions | Φ25×35 cm, Φ30×45 cm, Φ40×55 cm, Φ50×60 cm |
| Temperature Range | 105–132°C, 105–142.9°C, 105–155°C |
| Pressure Range | 0.2–2.0 kg/cm² (gauge), 0.2–3.0 kg/cm² (gauge), 0.2–3.5 kg/cm² (gauge) |
| Humidity Range | 65–100% RH (adjustable) |
| Controller | Dual-language (English/Chinese), USB & RS-232C interfaces, real-time data logging and curve export |
| Resolution | Temperature: 0.1°C, Humidity: 0.1% RH, Pressure: 0.1 kg/cm² |
| Temperature/Humidity Stability (Unsaturated Mode) | ±0.5°C / ±2.5% RH |
| Temperature/Humidity Stability (Saturated Mode) | ±0.5°C / 100% RH |
| Uniformity | ±0.5°C / ±5% RH |
| Bias Terminals | Standard: 8 channels (optional: 8–55 channels), AC/DC 125 V / 1 A |
| Pressurization Time | ~45–55 min depending on configuration |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,000 (FOB) |
| Internal Dimensions (Ø × L) | 30 cm × 50 cm |
| External Dimensions (W × H × D) | 56 cm × 45 cm × 82 cm |
| Operating Pressure Range | Up to 3 atm (gauge) |
| Temperature Range | 100 °C to 130 °C |
| Humidity Range | 85–100% RH (saturated steam environment) |
| Water Supply | Automatic float-controlled stainless steel reservoir |
| Safety Compliance | Meets IEC 60068-2-66, JESD22-A102D, MIL-STD-202 Method 108, and JEDEC JESD22-A110 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Internal Chamber Dimensions | Φ250×450 mm / Φ300×450 mm / Φ400×450 mm |
| Temperature Range | 100–132 °C |
| Humidity Range | 75–100 % RH (saturated steam) |
| Pressure Range | 0–2.5 kg/cm² above ambient atmospheric pressure |
| Circulation Method | Natural convection of saturated steam |
| Temperature Sensor | PT-100 Ω RTD (platinum resistance thermometer) |
| Heating Element | Insulated, high-voltage-rated resistive heater |
| Chamber Material | Stainless steel cylindrical inner chamber with arc-shaped interior walls |
| Sealing Mechanism | Self-tightening elastomeric packing under internal pressure |
| Pre-test Vacuum Function | Integrated vacuum pump with ≤1 µm particulate filtration |
| Safety Protection | Critical-point limit monitoring with fault indication and automatic shutdown |
| Auxiliary Functions | Timed post-test drying cycle |
| Water Management | Automatic water replenishment and controlled pressure release at test completion |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Temperature Range | 105–132 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Stability | ±0.5 °C |
| Humidity Range | 75–100 % RH |
| Humidity Stability | ±2.5 % RH |
| Humidity Uniformity | ±5.0 % RH |
| Pressure Range | 0.05–0.196 MPa (0.5–2.0 kgf/cm²) |
| Ramp Time (Temp) | ≤35 min (25→132 °C) |
| Ramp Time (Pressure) | ≤40 min (0→0.196 MPa) |
| Safety | Overpressure, overtemperature, and vacuum-failure interlocks |
| Compliance | Designed per JESD22-A110, JEDEC Standard, MIL-STD-883 Method 1030, and IEC 60068-2-66 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Temperature Range | 105–132 °C (control point) |
| Temperature Uniformity | ±2.0 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 75–100 % RH (control point) |
| Humidity Fluctuation | ±2.5 % RH |
| Humidity Uniformity | ±5.0 % RH |
| Pressure Range | 0.05–0.196 MPa (0.5–2 kgf/cm²) |
| Ramp Time (Ambient to 132 °C) | ≤35 min |
| Pressure Ramp Time (Ambient to 2 kgf/cm²) | ≤40 min |
| Water Level Auto-Replenishment | Yes |
| Post-Test Drying Function | Electric Heating Dry Mode |
| Compliance | ASTM B809, JESD22-A102, JEDEC JESD22-A110, IEC 60068-2-66 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Industrial Distributor |
| Price | USD 14,200 (FOB) |
| Chamber Volume | 75.4 L (Ø400 mm × L600 mm) |
| External Dimensions | 900 × 700 × 1600 mm (W×D×H) |
| Inner Tank Material | SUS316 Stainless Steel (3 mm thick) |
| Outer Casing | Optional SUS304 or Powder-Coated Steel |
| Insulation | Rock Wool + Rigid Polyurethane Foam (≥80 mm) |
| Steam Generator | Titanium Alloy Heating Element (Corrosion-Resistant) |
| Control System | Delta DOP-107EV Color Touch HMI + PLC-Based PID Algorithm |
| Temperature Sensor | PT-100 Platinum RTD (Class A, ±0.15 °C) |
| Pressure Indication | Analog Bourdon Tube Gauge (0–300 kPa, ±1.6% FS) |
| Humidity Control | Saturated Steam Generation with Auto-Water Refill (No Downtime Required) |
| Compliance | GB/T 10586–1989, GB/T 2423.3–2016 (IEC 60068-2-3), MIL-STD-810G Method 502.5, GJB 150.9A–2009, GB/T 2423.34–2012 (IEC 60068-2-52), MIL-STD-883K Method 1004.2 |
| Brand | Haytham |
|---|---|
| Model | Blue Box1200-32 |
| Origin | Guangdong, China |
| Type | Domestic |
| Supplier Type | Authorized Distributor |
| Pricing | Upon Request |
| Brand | Haytham |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BlueBox 2000-1Q |
| Pricing | Upon Request |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Tabletop Dimensions | 500 × 500 mm |
| Shaker Body Dimensions | 500 × 450 × 500 mm |
| Mounting Pattern | 25 × M10 threaded holes on tabletop |
| Vibration Axes | Vertical (Y-axis) and Horizontal (X-axis) |
| Frequency Range | 1–5000 Hz, resolution 0.01 Hz |
| Peak-to-Peak Displacement | 0–4 mm adjustable |
| Maximum Load Capacity | 75 kg |
| Rated Sinusoidal Force | 1125 kgf (11.03 kN) |
| Maximum Acceleration | ≤15 g |
| Waveform | Sine (full- or half-cycle) |
| Test Duration Setting | Programmable in seconds (0–999,999 s) |
| Power Consumption | 3.8 kW |
| Input Current | ≤15 A |
| Supply Voltage | 380 V ±20%, 3-phase, 50/60 Hz |
| Operating Temperature | −10 °C to +60 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Recommended Ambient | ≤28 °C with adequate ventilation |
| Brand | Hengpin (Jinan Hengpin Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HP603 |
| Force Capacity | 500 N (optional load cells: 100 N, 200 N, 1000 N, 2000 N, 5000 N) |
| Resolution | 0.01 N |
| Accuracy | ±0.1 N |
| Test Mode | Fracture Strength Measurement |
| Speed Range | 1–500 mm/min (adjustable in real time) |
| Speed Accuracy | ±0.1 mm/s |
| Dimensions (W×D×H) | 540 × 280 × 1250 mm |
| Weight | ~55 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Hengpin (Ji’nan) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (PRC) |
| Model | HP612Q |
| Price Range | USD 1,400 – 2,800 |
| Force Range Options | 50 N / 100 N / 500 N / 1000 N |
| Resolution | 0.1 N |
| Accuracy | ±0.5% FS |
| Test Speed | 1–300 mm/min |
| Upper Platen | 10 mm diameter ultra-hard tungsten carbide indenter |
| Parallelism between Platens | < 0.025 mm |
| Lower Platen Diameter | 120 mm |
| Dimensions (W×D×H) | 430 × 350 × 710 mm |
| Weight | 45 kg |
| Power Supply | 220 V AC, 50 Hz |
| Standard Accessories | Main unit, microsphere compression fixtures, thermal mini-printer |
| Optional | Lenovo PC, inkjet printer, PC-based control & analysis software |
| Brand | Hengyi / Hengyitest |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HY-2000N.MFFG |
| Max Torque | 2000 N·m |
| Torque Measurement Range | 2–2000 N·m |
| Torque Resolution | 1/50000 |
| Torsional Angle Measurement Range | 0–100000° (or continuous) |
| Motor Power | 5 kW |
| Brand | Hengyi / Hengyitest |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | HY(BP)-5080 |
| Price | Upon Request |
| Static Load Capacity | 50 kN |
| Dynamic Load Capacity | ±50 kN |
| Force Measurement Accuracy | ±0.5% of reading (full range, no range switching) |
| Force Resolution | 1/30,000 (constant across full range) |
| Effective Force Measurement Range | 0.5–20 kN |
| Displacement Range | ±50 mm |
| Displacement Accuracy | ±0.5% of reading (full range, no range switching) |
| Displacement Resolution | 1/30,000 (constant across full range) |
| Function Generator Frequency Range | 0.001–100 Hz |
| Waveform Types | Rectangular, triangular, sinusoidal, ramp, and user-defined waveforms |
| System Bandwidth (Host Response) | 0.01–20 Hz |
| Continuous Operating Frequency | 20 Hz |
| Cycle Counter Capacity | 999,999,999 (presettable) |
| Control Modes | Force and displacement control with seamless in-test switching |
| Effective Test Space | 800 mm |
| Column Spacing | 600 mm |
| Frame Height | 1900 mm |
| Frame Stiffness | 1.7 × 10⁸ N/mm |
| Frame Weight | 1200 kg |
| Hydraulic Power Unit Flow Rate | 80 L/min |
| Hydraulic Working Pressure | 25 MPa |
| Motor Speed | 1450 rpm |
| Actuator | Dual-rod, 150 mm bore |
| Load Cell | 50 kN (Transducer Technologies) |
| Displacement Transducer | 100 mm stroke |
| Controller | DOLI EDX-2000 full-digital servo controller (Germany) |
| Software | Hengyi proprietary fatigue testing software (Windows-based, GLP-compliant data logging) |
| Brand | Hengyi / Hengyitest |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | HY(BT)-60B |
| Instrument Type | Fully Automatic |
| Max Test Force | 60 kN |
| Force Measurement Range | 0.2–60 kN |
| Force Accuracy | ±1% |
| Test Speed | 2–100 mm/min (constant-rate control) |
| Punch Diameter | φ20 ± 0.05 mm |
| Specimen Thickness Capacity | 0.05–2 mm |
| Clamping Piston Stroke | 40 mm |
| Cupping Depth Resolution | 0.01 mm |
| Control System | PC-based with proprietary amplifier & high-precision optical encoder |
| Compliance | GB/T 4156–2023 (revised from GB 4156–1984), GB/T 5125–2008 (revised from GB 5125–1985) |