Physical Property Testing Instruments
Filter
Showing 1771–1800 of 12277 results
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-DSC400 |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | Ambient to 600 °C |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 °C/min (heating), −0.1–20 °C/min (cooling, air-cooled variant) |
| DSC Sensitivity | 0.0001 mW |
| Temperature Resolution | 0.001 °C |
| Atmosphere Control | Dual mass-flow-controlled gas channels + auxiliary purge line |
| Cooling Options | Air cooling, Peltier, mechanical refrigeration, or liquid nitrogen (model-dependent) |
| Software | Integrated GLP-compliant data acquisition and analysis suite with audit trail capability |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC400 |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | Ambient to 600 °C |
| Programmable Temperature Control | Intelligent PID Algorithm |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), –0.1 to –20 K/min (cooling) |
| Temperature Precision | ±0.001 °C |
| DSC Signal Range | ±1000 mW |
| Temperature Stability | ±0.1 °C |
| DSC Sensitivity | 0.0001 mW |
| Temperature Resolution | 0.001 °C |
| Cooling Options | Forced-air, Peltier, Mechanical Refrigeration, Liquid Nitrogen |
| Atmosphere Control | Dual independent mass-flow-controlled gas channels + dedicated purge gas inlet |
| Sensor Type | Corrosion-resistant, EMI-shielded thermocouple array |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Domestic Instrument Manufacturer |
| Model | DZ-DSC400C |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | −50 °C to 600 °C |
| Temperature Accuracy | ±0.001 °C |
| Temperature Precision (Resolution) | 0.001 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), −0.1 to −40 K/min (cooling) |
| Scan Modes | Isothermal, dynamic heating, dynamic cooling |
| DSC Signal Range | ±1000 mW |
| Temperature Stability (Drift) | ≤0.1 °C/h |
| Cooling Method | Peltier-based active refrigeration (standard) |
| Gas Control | Triple-gas manifold with automatic dual-atmosphere switching (e.g., N₂ ↔ O₂), plus dedicated inert purge line |
| Temperature Control Algorithm | Adaptive PID with self-tuning and dynamic/static hybrid compensation |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DZ-DSC400C |
| Sample Capacity | Single-sample |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −50 °C to 600 °C |
| Programmable Temperature Control | Intelligent PID with Self-Tuning & Adaptive Optimization |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), −0.1 to −40 K/min (cooling) |
| Temperature Precision | ±0.001 °C |
| DSC Signal Range | ±1000 mW |
| Temperature Stability | ±0.001 °C |
| Cooling Method | Integrated Thermoelectric (Peltier) Module |
| Gas Flow Control | Triple-channel Mass Flow System (0–200 mL/min per channel), Dual Atmosphere Switching with <3 s stabilization time, plus Dedicated Inert Purge Line |
| Temperature Resolution | 0.001 °C |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC400D |
| Price Range | USD 19,500–27,800 (FOB China) |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Heat-Flux DSC |
| Temperature Range | −70 °C to 600 °C |
| Temperature Control | Intelligent PID algorithm |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 °C/min (heating), −0.1 to −60 °C/min (cooling) |
| Temperature Precision | ±0.001 °C |
| DSC Signal Range | ±1000 mW |
| DSC Sensitivity | 0.0001 mW |
| Temperature Resolution | 0.001 °C |
| Gas Flow Range | 0–200 mL/min (expandable) |
| Cooling Method | Integrated mechanical refrigeration system (supplemented by optional air-cooling, Peltier, and liquid nitrogen interfaces) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-DSC400L |
| Sample Capacity | Single |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −170 °C to 600 °C |
| Programmable Temperature Control | Intelligent PID |
| Temperature Accuracy | ±0.001 °C |
| Heating/Cooling Rate | 0.1–100 K/min (heating), −0.1 to −80 K/min (cooling) |
| Scan Modes | Isothermal, Heating, Cooling |
| DSC Signal Range | ±1000 mW |
| DSC Sensitivity | 0.0001 mW |
| Temperature Resolution | 0.001 °C |
| Gas Flow Control | Dual-channel mass flow controller (0–200 mL/min, expandable), plus dedicated purge/protect gas inlet |
| Cooling Method | Liquid nitrogen cryogenic cooling (supplemented by optional air-cooling, Peltier, or mechanical refrigeration modules) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-STA200 |
| Temperature Range | Ambient to 1250 °C |
| Heating Rate | 0.1–100 °C/min |
| Maximum Sample Mass | 30 g |
| Atmosphere Control | Inert, Oxidizing, Reducing |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Balance Range | 0.01 mg–3 g (extendable to 30 g) |
| Balance Sensitivity | 0.01 mg |
| DSC Range | 0 to ±800 mW |
| DSC Resolution | 0.001 mW |
| Atmosphere System | Dual-gas mass flow control with integrated flow meters |
| Display | 7-inch 24-bit color LCD touchscreen |
| Data Interface | Standard USB |
| Power Supply | AC 220 V, 50 Hz |
| Crucible Material | High-purity alumina ceramic |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-STA401 |
| Price Range | USD 21,000–28,000 |
| Temperature Range | Ambient to 1250 °C |
| Heating/Cooling Rate | 0.1–100 °C/min (heating), −0.1 to −40 °C/min (cooling) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| Maximum Sample Mass | 30 g (expandable to 50 g) |
| Mass Resolution | 0.01 mg |
| Mass Accuracy | ±1 mg |
| DSC Sensitivity | ±1000 mW |
| Atmosphere Control | Triple-gas mass flow control (digital MFCs) |
| Data Acquisition Interval | Real-time, 2 s, 5 s, or 10 s selectable |
| Cooling Time | ≤15 min (1000 °C → 50 °C) |
| External Water Cooling | Integrated chiller interface (−10 °C to 60 °C) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZ-STA401 |
| Price | Upon Request |
| Temperature Range | Ambient to 1250 °C |
| Heating/Cooling Rate | 0.1–100 °C/min (heating), −0.1 to −40 °C/min (cooling) |
| Temperature Stability | ±0.01 °C |
| Temperature Resolution | 0.001 °C |
| Sample Capacity | 30 g max |
| Mass Measurement Range | 0.01 mg–3 g (expandable to 50 g) |
| Mass Accuracy | 0.01 mg |
| Mass Resolution | 0.01 µg |
| DSC Range | ±1000 mW |
| DSC Sensitivity | 0.0001 mW |
| Atmosphere Control | Integrated Digital Mass Flow Controller |
| Cooling Mode | Optional External Water Chiller (−10 to 60 °C) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-STA401 |
| Technique | TG-DSC |
| Temperature Range | Ambient to 1250 °C |
| Heating Rate | 0.1–100 °C/min |
| Temperature Stability | ±0.01 °C |
| Mass Resolution | 1 µg |
| Mass Range | 0.01 mg–3 g (expandable to 50 g) |
| Maximum Sample Capacity | 30 g |
| Atmosphere Control | Inert, oxidative, reductive |
| Gas Flow Control | Digital mass flow controller |
| Cooling Time (1000 °C → 50 °C) | ≤20 min |
| Temperature Resolution | 0.1 °C |
| DSC Sensitivity | ±1000 mW |
| Furnace Material | Dual-wound Pt-Rh alloy heating element |
| Sensor | High-purity noble metal alloy microbalance sensor |
| Thermal Insulation | Dual-layer vacuum-insulated furnace housing |
| Integration Capability | FTIR coupling interface compliant with standard gas outlet port |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Region Classification | Domestic (PRC) |
| Model | DZ-TGA201 |
| Pricing | Upon Request |
| Temperature Range | Ambient to 1250 °C |
| Mass Resolution | 1 µg |
| Mass Accuracy | ±1 µg |
| Dynamic Weighing Capacity | 0.01 mg–3 g (expandable to 50 g) |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Maximum Sample Load | 50 g |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ-TGA201 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 1250 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Accuracy | ±0.001 °C |
| Dynamic Weighing Range | 0.01 mg to 3 g (expandable to 50 g) |
| Balance Sensitivity | 0.01 µg |
| Mass Accuracy | 0.01 mg |
| Heating Rate | 0.1–100 °C/min |
| Cooling Rate | –0.1 to –40 °C/min |
| Maximum Sample Mass | 30 g |
| Mass Precision | 0.01 mg |
| Temperature Stability | ±0.01 °C |
| Cooling Time (1000 °C → 50 °C) | ≤20 min (standard), ≤15 min with optional cryo-cooling unit |
| Atmosphere Control | Triple-gas mass flow controller |
| Data Acquisition Intervals | Real-time, 2 s, 5 s, or 10 s selectable |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZ3320A |
| Sample Capacity | Single |
| Instrument Type | Differential Thermal Analyzer (DTA) |
| Temperature Range | Ambient to 1150 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DTA Signal Range | 0 to ±2000 µV (expandable) |
| DTA Sensitivity | 0.01 µV |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Control Interface | USB bidirectional communication |
| Display | 7-inch 24-bit color LCD touchscreen |
| Sensor Material | Ni-Cr alloy thermocouple |
| Furnace Design | Top-opening vertical furnace |
| Atmosphere Control | Programmable internal gas switching |
| Power Supply | AC 220 V, 50 Hz |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single-sample mode |
| Test Environment | Ambient temperature operation |
| Thermal Conductivity Range | 0.00001–50 W/(m·K) |
| Resolution | 0.00001 W/(m·K) |
| Repeatability | ≤1% |
| Accuracy | ±1% |
| Temperature Range | −30 °C to 200 °C |
| Sample Forms | Solids (bulk, metallic, thin films), powders, granules, liquids, gels, pastes, and insulating materials |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Minimum Solid Sample Dimensions | 15 mm × 15 mm × 7.5 mm (Probe #1) |
| Liquid/Powder Sample Volume | 18 mL via dedicated fixture |
| Measurement Time | ≤160 s per test |
| Power Consumption | <300 W |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-AS |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single-sample per test |
| Test Environment | Ambient temperature (with optional environmental chamber integration) |
| Thermal Conductivity Range | 0.00001–50 W/(m·K) |
| Temperature Range | –30 °C to 200 °C |
| Resolution | 0.00001 W/(m·K) |
| Repeatability | ≤1% RSD |
| Accuracy | ±2% (traceable to NIST-certified reference materials) |
| Sample Forms | Solids (bulk, thin films, foams), liquids, powders, pastes, gels, and elastomers |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Minimum Solid Sample Dimensions | 15 mm × 15 mm × 7.5 mm (Probe #1) |
| Liquid/Powder Sample Volume | 18 mL via dedicated fixture |
| Measurement Time | ≤160 s per test |
| Power Consumption | <300 W |
| Display | 7-inch color capacitive touchscreen interface |
| Control Architecture | Bidirectional software–instrument communication (USB/Ethernet) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Model | DZDR-AS |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Thermal Conductivity Range | 0.0001–50 W/(m·K) |
| Temperature Range | −40 °C to 200 °C |
| Accuracy | ±0.0001 W/(m·K) |
| Repeatability | ≤1% |
| Measurement Time | ≤160 s |
| Sample Forms | Solids (blocks, metals, films), Liquids, Powders, Gels, Pastes, and Insulating Materials |
| Sample Requirements | Surface must be flat and smooth |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Power Consumption | <300 W |
| Solid Sample Dimensions (Probe #1) | ≥15 mm × 15 mm × 3.75 mm |
| Solid Sample Dimensions (Probe #2) | ≥30 mm × 30 mm × 7.5 mm |
| Liquid/Powder Sample Volume | 18 mL (with dedicated fixture) |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Domestic Instrument Manufacturer |
| Model | DZDR-AS |
| Measurement Principle | Transient Plane Source (TPS) Method |
| Sample Throughput | Single-sample per test |
| Operating Environment | Ambient temperature |
| Thermal Conductivity Range | 0.0001–50 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Repeatability | ≤1% |
| Accuracy | ±0.0001 W/(m·K) |
| Temperature Range | −40 °C to 200 °C (expandable) |
| Sample Form Compatibility | Solid blocks, metals, liquids, powders, gels, pastes, thin films, thermal insulation materials, alloys, ores, polymers, and foams |
| Test Duration | <160 s |
| Probe Configuration | Dual high-precision TPS sensors (standard) |
| Sample Dimensions | Probe #1: 7.5 × 7.5 × 3.75 mm |
| Probe #2 | 15 × 15 × 7.5 mm |
| Power Supply | AC 220 V |
| Max. Power Consumption | <300 W |
| Max. Sample Temperature Rise | <20 °C |
| Probe Power Range | Probe #1: 0–1 W |
| Probe #2 | 0–15 W |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-AS |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single sample per test |
| Test Environment | Ambient temperature |
| Thermal Conductivity Range | 0.0001–50 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Repeatability | ≤1% |
| Temperature Range | −40 °C to +200 °C (expandable) |
| Sample Forms | Solid blocks, metals, liquids, powders, pastes, gels, thin films, foams, polymers, alloys, minerals, and thermal insulation materials |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-AS |
| Instrument Type | Transient Plane Source (TPS) Method |
| Sample Throughput | Single sample per test |
| Test Environment | Ambient temperature |
| Thermal Conductivity Range | 0.00001–50 W/(m·K) |
| Resolution | 0.0001 W/(m·K) |
| Repeatability | ≤1% |
| Accuracy | ±0.00001 W/(m·K) |
| Test Atmosphere | Ambient air (no controlled atmosphere) |
| Temperature Range | −30 °C to 200 °C |
| Sample Forms Supported | Solids (bulk, metallic), liquids, powders, pastes, gels, thin films, and aerogels |
| Brand | DAZHAN |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DZDR-S |
| Instrument Type | Transient Plane Source Method |
| Sample Throughput | Single sample per test |
| Test Environment | Ambient temperature (standard) |
| Thermal Conductivity Range | 0.0001–300 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ≤3% |
| Sample Forms | Solid blocks, pastes, granular solids, gels, liquids, powders, coatings, thin films, and thermal insulation materials |
| Brand | DC-Energies |
|---|---|
| Model | DC |
| Type | Ultrasonic Spray Coating System for Catalyst Inks |
| XY Travel Range | 200 × 200 mm |
| Z-Axis Travel | 50 mm |
| Dispensing System | Programmable Flow Rate Control |
| Hotplate Dimensions | 220 × 220 mm |
| Heating Temperature | Up to 200 °C |
| Vacuum Substrate Hold-Down | Integrated |
| Power Supply | 220 VAC, 50 Hz, <800 W |
| Overall Dimensions | 630 × 600 × 630 mm (W×D×H) |
| Weight | <50 kg |
| Max Coating Area | 200 × 200 mm² |
| Compatible Processes | CCS, CCM, Thermal Transfer |
| Brand | DD KJ |
|---|---|
| Origin | Chongqing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YW-060 |
| Internal Volume | 60 L |
| Temperature Range (Chamber) | 35–55 °C |
| Temperature Range (Saturated Air Chamber) | 45–75 °C |
| Temperature Fluctuation | ≤ 0.5 °C |
| Temperature Uniformity | < 2 °C |
| Temperature Deviation | ±2 °C |
| Ramp-up Time to Operating Temperature | ≤ 60 min |
| Power Consumption | 1.0 kW |
| Supply Voltage | 220 V, 50 Hz |
| Internal Dimensions (W×D×H) | 600 × 400 × 400 mm |
| External Dimensions (W×D×H) | 1100 × 650 × 900 mm |
| Standard Accessories | V- and O-type Sample Racks |
| Compliance | ASTM B117, ISO 9227, JIS Z2243 |
| Brand | DDS |
|---|---|
| Origin | South Africa |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CAL3K-AP |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Isoperibolic (Constant-Temperature Jacket) |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.0001 °C |
| Precision | ±0.1% RSD |
| Single-Sample Test Time | ~15 min (standard), down to 4–6 min with dual-bomb operation |
| Heat Capacity Calibration Range | 99,000 J/K |
| Cooling Medium | Forced Air |
| Water-Free Operation | Yes |
| Max. Energy Measurement | 99 MJ |
| Min. Operating Temp. | 0 °C |
| Max. Operating Temp. | 50 °C |
| Temp. Stability Resolution | 10 ppm |
| Throughput | ≥10 samples/h (with dual bomb + air cooler) |
| Compliance | ASTM D240, D5865, D4809, D5468, E144, E711 |
| BS 4791 | 1985 |
| Brand | Defelsko |
|---|---|
| Origin | USA |
| Model | PosiTector 200 |
| Measurement Range (B/S) | 13–1000 µm |
| Measurement Range (C/A) | 50–3800 µm |
| Accuracy | ±(2 µm + 3% of reading) |
| Total Thickness Measurement | Yes |
| Layered Thickness Measurement | B/A & C/A models only |
| Waveform Display | B/A & C/A models only |
| Compliance | ISO 2808, ASTM D6132 |
| Calibration | NIST-traceable certificate supplied with each unit |
| Data Storage | 10,000 readings across 1,000 groups |
| Environmental Rating | IP5X |
| Display | Backlit LCD with multi-language support (including Chinese) |
| Software Compatibility | PosiSoft for Windows |
| Optional Accessories | Infrared printer |
| Brand | Defelsko |
|---|---|
| Origin | USA |
| Model | PosiTector 6000 |
| Probe Types | F (magnetic substrate), N (non-magnetic substrate), FN (dual-mode auto-recognizing) |
| Compliance | ASTM D7091, ISO 2178, ISO 2360, SSPC-PA 2 |
| Protection Rating | IP5X |
| Interface | USB + infrared |
| Data Storage | up to 10,000 readings (Storage model), 250 readings (Statistics model), real-time clock, statistical reporting (mean, std dev, min/max, count) |
| Software | PosiSoft for Windows (included with Storage model) |
| Calibration | NIST-traceable certificate included, one-point/zero-point/two-point calibration modes |
| Display | backlit LCD, multi-language support (including English, Chinese, Spanish, German, French), metric/imperial unit toggle |
| Operating Environment | -10 °C to 50 °C |
| Probe Cable Options | standard and custom lengths up to 75 m |
| Brand | Defelsko |
|---|---|
| Origin | USA |
| Model | PosiTest AT |
| Compliance | ASTM D4541, ISO 4624 |
| Measurement Principle | Hydraulic Pull-Off |
| Accuracy | ±1% of full scale (NIST-traceable) |
| Load Range | 0–3000 psi (0–20 MPa) |
| Probe Sizes | 10 mm, 14 mm, 20 mm, 50 mm |
| Resolution | ±1 psi (±0.01 MPa) for 20 mm probe |
| Self-Centering Base | Yes |
| Display | Backlit LCD (psi / MPa) |
| Data Storage | Up to 200 tests with date/time/stamp size |
| Interface | USB |
| Software | PosiSoft (Windows), multilingual (EN/DE/FR/IT/ES), supports annotation, CSV/DOC export |
| Environmental Rating | IP65 (dustproof, water-resistant, shock-resistant) |
| Warranty | 1 year |
| Brand | Defelsko |
|---|---|
| Origin | USA |
| Model | PosiTest DFT |
| Measurement Principle | Magnetic Induction (for ferrous substrates) & Eddy Current (for non-ferrous substrates) |
| Range | 0–1000 µm |
| Accuracy | ±(2 µm + 3%) |
| Dimensions | 100 × 38 × 23 mm |
| Weight | 70 g |
| Probe Type | Wear-resistant ruby-tipped sensor |
| Display | Backlit LCD |
| Power Management | Auto-on / auto-off |
| Calibration | Zero-point calibration |
| Geometry Support | V-groove for curved surfaces |
| Units | Metric/imperial toggle |
| Compliance | ASTM D7091, ISO 2178, ISO 2360, SSPC-PA 2, AS 3894.3 |
| Brand | Defelsko |
|---|---|
| Origin | USA |
| Model | PosiTest F/G |
| Measurement Principle | Electromagnetic Induction (F-type) / Eddy Current (G-type) |
| F-Type Range | 0–2000 µm (0–80 mils) |
| G-Type Range | 0–200 µm (0–8 mils) |
| F-Type Accuracy | ±5 µm (≤100 µm), ±5% of reading (>100 µm) |
| G-Type Accuracy | ±1 µm (≤20 µm), ±5% of reading (>20 µm) |
| Probe Type | Permanent Magnet (F) / High-Frequency Eddy Current (G) |
| Compliance | ASTM D7091, ISO 2178, ISO 2360, SSPC-PA 2, GB/T 4956, GB/T 4957 |
| Power Source | None (magnet-driven) |
| Environmental Rating | IP65-equivalent robust housing |
| Calibration | NIST-traceable certificate supplied with each unit |
| Brand | Delta Instruments (delta17) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DELTA-gs001 |
| Price Range | USD 2,800 – 7,200 |
| Platform Dimensions | 700 mm × 800 mm |
| Max Load Capacity | 100 kg (customizable) |
| Peak Acceleration | Half-Sine: 30–600 g |
| Post-Peak Sawtooth | 30–100 g |
| Square Wave (optional) | 30–120 g |
| Pulse Duration | Half-Sine: 1–30 ms |
| Post-Peak Sawtooth | 6–18 ms |
| Square Wave (optional) | 6–18 ms |
| Acceleration Tolerance | ≤ ±10% |
| Velocity Change Tolerance | ≤ ±10% |
| Lateral Motion Ratio | ≤ 10% |
| Overall Dimensions | 1300 mm × 1200 mm × 2650 mm |
| Mass | 1800 kg |
| Data Acquisition Channels | 2 |
| Sampling Rate | 500 kHz |
| Max Measurable Acceleration | 5000 g |
| Input Voltage Range | ±10 V<sub>PEAK</sub> |
| Sensor Type | Piezoelectric Charge Output |
| Sensor Model | B&W 22100 |
| Sensitivity | 3.93 pC/g |
| Frequency Range | 0.5–12 kHz |
| Acceleration Range | ±2500 g |
| Operating Environment | −40 °C to +160 °C |
| Power Supply | 3-phase AC 380 V ±10%, 5 kVA |
| Compressed Air | 0.5–0.8 MPa |
| Ambient Temp | RT–40 °C |
| Relative Humidity | <85% RH at 25 °C |
| MTBF | ≥5000 h |
| Half-Sine Generator Duty Cycle | ≥8000 consecutive impacts |
| Storage Life (clean, ambient conditions) | ≥5 years |
| Compliance | GB/T 2423.5–1995, GJB 150.18A–2009, GJB 360B–2009, IEC 60068-2-27, MIL-STD-810H, MIL-STD-202G, GB/T 18287, GB 31241, JG 541–2005 |
| Software Functions | Shock Response Spectrum (SRS), Pulse Analysis, Damage Boundary Analysis, Time-Domain Impact Response Calculation, FFT, Force–Deformation Correlation (auxiliary) |
| Brand | DELTA Instruments |
|---|---|
| Model | DELTA-SBT50 |
| Type | Electro-Mechanical Shock Test Table |
| Max Load Capacity | 50–500 kg |
| Standard Waveform | Half-Sine Pulse |
| Compliance | GB/T 2423.5, GB/T 2423.6, IEC 60068-2-29, GB/T 31467.3, JJG 497 |
| Control System | PC-Based Closed-Loop Digital Control with Real-Time Acceleration Feedback |
| Pulse Duration Adjustment | Via Interchangeable Anvil Pads |
| Peak Acceleration Adjustment | Via Adjustable Drop Height |
| Automated Stop | After Predefined Impact Count or Time Duration |
| Data Acquisition | Integrated Accelerometer, Velocity Change (Δv), Pulse Width, and G-Value Normalization |
| Safety | Mechanical Locking Mechanism for Anvil Pad Replacement |
| Dual-Mode Operation | Shock (Single-Impact) and Bump/Collision (Repetitive Impact) Modes |
| Software Features | Real-Time Waveform Display, Tolerance Band Overlay, Exportable CSV/PDF Reports, Audit-Trail-Ready Logging (GLP-Compatible) |