Physical Property Testing Instruments
Filter
Showing 1801–1830 of 12277 results
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DELTA1111 |
| Quotation | Available upon Request |
| Test Standards | ISO 6925, CFR 1630/1631, BS 6307, BS 4790, GB/T 20394–2013, GB/T 11049–2008, GB/T 14768–2015 |
| Sample Size | 230 mm × 230 mm (8 specimens per test) |
| Heating Source | Hot Metal Nut Method & Hexamethylenetetramine (Urotropine) Pellet Method |
| Ignition | Automatic Pulse Ignition |
| Timing Range | Flame Application Time: 0–99 s/min |
| Flame Application & Withdrawal Interval | 1.0–999.9 s (digital preset) |
| Afterflame Time | 1.0–999.9 s (digital readout) |
| Repetition Cycles | 1–9999 (digital preset) |
| Test Chamber Dimensions | 300 mm × 300 mm × 300 mm (W×D×H) |
| Ventilation Hood Volume | 2 m³ with Auto-Exhaust & Explosion-Proof Lighting |
| Exhaust Duct Diameter | Ø110 mm |
| Control System | PLC + 7-inch HMI Touchscreen |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Stainless Steel Hot Plate | 230 mm × 230 mm × 6.5 ±0.5 mm, central aperture Ø205 mm |
| Desiccant | Color-Indicating Silica Gel GPE0038 |
| Safety Features | Interlocked Protective Door, Black Interior Finish, Observation Window with Integrated LED Illumination |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.119-L |
| Standards Compliance | JIS K6260, ASTM D813, BS 903 Part A24, ISO 132 |
| Operating Temperature Range | –70 °C to +50 °C (chamber-controlled) |
| Sample Mounting | Dual parallel clamping discs, planar reciprocating motion |
| Stroke Frequency | Adjustable up to 300 cycles/min |
| Specimen Geometry | Standard dumbbell or rectangular strips per ISO 527-2 and ASTM D412 |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | DenDi |
| Price Range | USD 21,000–28,000 (FOB) |
| Application | Petroleum Product Density Measurement |
| Instrument Type | Buoyancy-Based Densimeter |
| Form Factor | Portable |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ (0–3000 kg/m³) |
| Density Accuracy | ±0.0005 g/cm³ (±0.5 kg/m³) or ±0.001 g/cm³ (±1.0 kg/m³) |
| Temperature Range | +15 to +30 °C (+59 to +86 °F) |
| Temperature Accuracy | ±0.2 °C (±0.4 °F) |
| Minimum Sample Volume | < 2 mL |
| Calibration Medium | Distilled water only |
| Compliance | ASTM D1298, ASTM D1250, ISO 3675, ISO 12185 |
| Brand | Derui Testing |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DR-D201-225E |
| Temperature Range | −60 °C to +150 °C |
| Refrigeration Method | Compressor-Based Cooling |
| Explosion-Proof Design | Yes (Class I, Division 1 compliant per GB/T 3836.1–2021) |
| Temperature Fluctuation | ±0.5 °C (empty chamber) |
| Temperature Deviation | ±2.0 °C (loaded, steady-state) |
| Temperature Uniformity | ±2.0 °C (empty chamber) |
| Heating Rate | ≤60 min (−60 °C to +150 °C) |
| Cooling Rate | ≤45/60/80 min (varies by target temperature span) |
| Interior Dimensions | 500 mm × 750 mm × 600 mm (W × H × D), dual-layer configuration |
| Effective Volume | 225 L (total, split across two independent zones) |
| Brand | Derui Testing |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DR-H202-V25 |
| Quotation | Upon Request |
| Internal Dimensions (W×D×H) | 2500 × 2200 × 2000 mm |
| Temperature Range | −40 °C to +150 °C |
| Temperature Uniformity | ±2 °C |
| Temperature Control Resolution | 0.1 °C |
| Heating Rate | 3 °C/min |
| Brand | Yuelian / PW |
|---|---|
| Model | PCT-30 |
| Temperature Range | +100 °C to +132 °C (saturated steam) |
| Humidity | 100 % RH (saturated steam) |
| Pressure Range | 0.5–3.0 kgf/cm² (internal chamber rated to 4.0 kgf/cm²) |
| Test Duration | 0–999 h |
| Chamber Dimensions (ID) | Ø260 mm × 400 mm (cylindrical) |
| External Dimensions | 1000 × 700 × 1000 mm (desktop) or 1000 × 700 × 1400 mm (floor-standing) |
| Inner Chamber Material | SUS-304 stainless steel |
| Control System | Yokogawa UT-150 microprocessor-based PID controller with LED time display, analog pressure gauge, manual water inlet valve, pre-test vacuum function, and post-test vacuum drying |
| Compliance | GB/T 2423.1–1989, GB/T 2423.2–1989, GB/T 2423.3–1993 |
| Key | Temperature Range: –40 °C to +150 °C (standard) |
|---|---|
| Humidity Range | 30–98% RH (standard) |
| Temperature Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 color LCD touchscreen programmable controller |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G (customizable to 220 V) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or A3 steel with electrostatic powder coating |
| Key | Brand: OEM/Third-party Manufacturer |
|---|---|
| Origin | Imported |
| Supplier Type | Distributor |
| Price | USD 5,300–12,800 (FOB) |
| Chamber Volume | 100–1000 L |
| Spectral Range | 300–1200 nm |
| Irradiance Control | 550 W/m² (300–800 nm) ±10% |
| Black Panel Temperature Range | 40–85°C |
| Cabinet Temperature Range | 0–150°C |
| Humidity Range (Light Cycle) | 20–75% RH |
| Humidity Range (Dark Cycle) | 20–98% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Temperature Accuracy | ±0.5°C |
| Humidity Accuracy | ±2.0% RH |
| Spray Duration | 1–999 min (intermittent/continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer mesh tray or 500 mm diameter rotating turntable (0–3 rpm) |
| Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≈1500 h at nominal irradiance |
| Filter System | Daylight- and Window-glass-type optical filters |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,200–14,800 (FOB) |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–98% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) / 1000 W/m² ±10% (300–1200 nm) |
| Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≈1,500 h |
| Spray Cycle | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer mesh tray or 500 mm rotary turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Compliance | ASTM G155, ISO 4892-2, AATCC TM16, SAE J2527, GB/T 16422.2 |
| Brand | OK Instruments |
|---|---|
| Model | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Type | Benchtop Xenon Arc Environmental Test Chamber |
| Light Source | Long-Arc Air-Cooled Xenon Lamp (1.8–6 kW) |
| Spectral Range | 300–800 nm (550 W/m² ±10%) and 300–1200 nm (1000 W/m² ±10%) |
| Black Panel Temperature Range | 40–85°C |
| Chamber Temperature Range | 0–150°C |
| Humidity Control | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Humidity Accuracy | ±2.0% RH |
| Temperature Accuracy | ±0.5°C |
| Uniformity | ±2.0°C (temp), ±3.0% RH (humidity) |
| Spray Duration | 1–999 min (intermittent/continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Lamp Life | ~1500–1600 hours |
| Filter System | Precision broadband optical filters for solar-spectrum simulation |
| Compliance | Designed to support ASTM G155, ISO 4892-2, AATCC TM16, SAE J2527, and GB/T 16422.2 test protocols |
| Brand | SINOTEST |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Equipment Type | Hydraulic Universal Testing Machine |
| Model | DF71 Series |
| Test Force Range | 600 kN – 3000 kN |
| Applicable Standards | GB/T 2611, GB/T 50081, JJG 139 |
| Primary Applications | Compressive strength testing of concrete, cement, and rock |
| Brand | Volstaedt |
|---|---|
| Origin | Germany |
| Model | DiaTest-ASM |
| Power Supply | 100–230 V AC, 24 V DC/1.8 A (external switch) |
| Force Range | 0–2000 N (primary), 0–200 N (auxiliary) |
| Overload Capacity | 2300 N |
| Force Resolution | 3 N (system-wide), 0.3 N (sensor-level) |
| Force Measurement Error | ±20 N (±2 N per subcomponent) |
| Particle Size Range | 150 µm – 2 mm |
| Optical Resolution | 4.2 µm/pixel |
| Image Sensor | 1388 × 1038 pixels |
| Anvil Material | Polycrystalline Diamond (PCD) |
| Conveyor Medium | 12 mm transparent polycarbonate tape |
| Operating Pressure | 4.2–4.6 bar (adjustable), Input Pressure: 6–10 bar |
| Cycle Time | ~50 min per batch (500 particles) |
| PC Requirements | Windows 7 or XP (32-bit), 1× USB 2.0, 1× PCI or PCIe slot |
| Brand | Haytham |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 200X |
| Pricing | Available Upon Request |
| Brand | Digerui |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DKR |
| Price | USD 140 (approx.) |
| Key Standards | GB 15811-2016, YY/T 0167, ISO 7864, ASTM F2182 |
| Nominal Needle Gauge Range | 0.2–3.4 mm |
| Force Measurement Range | 0–20 N (standard), 0–50 N (optional) |
| Force Accuracy | ±0.5% FS |
| Crosshead Speed Range | 0–500 mm/min |
| Speed Accuracy | Class 0.5 |
| Penetration Substrate | Medical-grade polyurethane membrane per GB 15811 |
| Display | 7-inch industrial capacitive touchscreen |
| Data Output | Built-in thermal printer |
| Software | Multi-level user permission management, remote firmware update capability |
| Compliance | Designed for GLP-aligned lab environments |
| Brand | Digerui |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DKR-HCOF- |
| Force Range | 10 N (standard) |
| Accuracy | Better than Class 0.5 |
| Force Resolution | 0.01 N |
| Displacement Accuracy | Class 0.5 |
| Displacement Resolution | 0.1 mm |
| Test Speed | 1–800 mm/min (infinitely variable) |
| Stroke | 1000 mm |
| COF Test Distance | >150 mm |
| Catheter Clamp Gap | 0–50 mm |
| Water Bath Temperature Control Range | Ambient to 40 °C |
| Sample Capacity | 1 catheter per test |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 540 × 450 × 1560 mm |
| Net Weight | 92 kg |
| [Key | Value] |
|---|---|
| Brand | OEM / Custom Brand Available |
| Origin | Imported (Manufactured Outside China) |
| Manufacturer Type | Authorized Distributor |
| Price Range | USD 2,800–3,200 (FOB) |
| Temperature Range | −70 °C to +150 °C (configurable per model) |
| Humidity Range | 20–98% RH |
| Control Accuracy | ±0.5 °C (temp), ±2.5% RH (humidity) |
| Uniformity | ±1.0 °C (temp), ±3.0% RH (humidity) |
| Ramp Rate | 1–3 °C/min (average air temperature, unloaded) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Product Origin | Domestic |
| Model | SGW |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Max Test Load | 10 kN |
| Load Application Rate | 5–700 N/s |
| Platen Spacing | 200 mm |
| Platen Dimensions | 300 × 300 mm |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,200 (FOB) |
| Load Cell Accuracy | ±0.03% F.S. |
| Force Resolution | 1/100,000 full scale |
| Encoder Resolution | 2500 pulses/rev |
| Drive System | Panasonic AC Servo Motor |
| Transmission | Precision Ball Screw & Linear Guide Rails |
| Overload Capacity | 150% of rated load |
| Compliance | GB/T 16491, GB/T 1040, GB/T 8808, GB/T 13022, GB/T 2790–2792, GB/T 16825, GB/T 17200, GB/T 3923.1, GB/T 528, GB/T 2611, GB/T 6344, GB/T 20310, GB/T 3690, GB/T 4944, GB/T 3686, GB/T 529 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,200 (FOB) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | DIL0806 A/B |
| Price Range | USD 7,000–14,000 |
| Temperature Range | RT to 1000 °C |
| Heating Rate | 0–20 °C/min |
| Temperature Accuracy | ±1 °C |
| Max. Sample Length | 50 mm |
| Stroke Range | 5 mm |
| Measurement Resolution | 0.1 µm |
| Atmosphere Options | Air, Reducing, Inert |
| Brand | Dillon |
|---|---|
| Origin | United Kingdom |
| Model | AWT05-506447 |
| Construction | Industrial-grade RF module with IP65-rated housing |
| Operating Range | Up to 300 ft (91 m) line-of-sight |
| Battery Life | ≥12 months (CR2032 lithium coin cell) |
| Compatibility | All Dillon EDXTREME series digital force gauges (EDx–1T through EDx–250T) |
| Protocol | Proprietary 2.4 GHz FHSS (Frequency-Hopping Spread Spectrum) |
| Certifications | CE, UKCA, FCC Part 15 Subpart C |
| Brand | HENGYU |
|---|---|
| Origin | Tianjin, China |
| Model | HY-766-1 |
| Roller Diameter | 150 mm |
| Test Modes | Rotating & Non-Rotating Specimen Mounting |
| Dimensions (L×W×H) | 95 × 66 × 31 cm |
| Weight | 55 kg |
| Power Supply | AC 220 V, 50 Hz, 500 W |
| Operating Environment | 23 ± 2 °C, 50 ± 5 % RH |
| Compliance | GB/T 9867–2008, ISO 4649:2002, GB/T 26703–2011, DIN 53516 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery DMA 850 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –160 to 600 °C |
| Force Range | 0.0001–18 N |
| Resolution (Displacement) | 0.1 nm over 25 mm travel |
| Bearing Type | Frictionless air bearing |
| Actuation | Non-contact lightweight motor |
| Control Technology | DirectStrain™, Auto-Ranging |
| Cooling | Integrated mechanical refrigeration (down to –100 °C without LN₂) |
| Software | TRIOS™ |
| Warranty | 5-year furnace warranty |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | Discovery TGA 55 |
| Temperature Range | Ambient to 1000 °C |
| Balance Sensitivity | 0.1 μg |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Baseline Drift | <25 μg |
| Brand | DITECT |
|---|---|
| Origin | Japan |
| Model | DIPP-Macro II |
| Instrument Type | Static Image Analysis System |
| Compliance | ASTM E2457, ISO 13322-1, USP <429> (Image Analysis) |
| Data Output Formats | CSV, TIFF, AVI, PNG, PDF |
| Software Architecture | Windows 64-bit (Windows 10/11), GPU-accelerated processing |
| License Type | Perpetual node-locked or floating license |
| Regulatory Support | Audit trail, user access control, electronic signature readiness (FDA 21 CFR Part 11 compliant configuration available) |
| Brand | DITECT |
|---|---|
| Origin | Japan |
| Model | DIPP-Strain |
| Type | Standalone DIC Software (2D & 3D) |
| Supported Configurations | Single-camera 2D DIC, Dual-/Multi-camera Stereo DIC |
| Input Formats | AVI, WMV, MPEG, CINE, JPEG, BMP, GIF, TIFF, PNG |
| Output Formats | AVI, WMV, MP4, JPEG, BMP, PNG |
| Key Results | 2D — εₓ, εᵧ, γₓᵧ, ε₁ |
| OS | Windows 10/11 Home or Pro (64-bit) |
| CPU | Intel Core i5 or higher (multi-core) |
| RAM | ≥8 GB |
| HDD | ≥10 GB free space |
| Display | ≥1920×1080 resolution |
| [Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DJF-50KN |
| Pricing | Available Upon Request] |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DJH |
| Pricing | Available Upon Request |
| Brand | DJH Designs |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DJH Crater Film Thickness System |
| Price | Upon Request |
| Drilling Accuracy | ±0.17 µm |
| Sample Thickness Range | 0–2 mil (0–50.8 µm) and 0–8 mil (0–203.2 µm) with interchangeable carbide drill bits |
| Drill Unit Minimum Substrate Thickness | >50 µm |
| Net Weight | 65 lbs (29.5 kg) |
| Gross Weight | 80 lbs (36.3 kg) |
| Packaging Dimensions | 610 mm × 610 mm × 610 mm |
| Power Supply | 220 V / 50 Hz |
