| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | C 3000 eco |
| Calorimetric Principle | Isoperibol Oxygen Bomb Calorimetry |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Single-Sample Measurement Time | 15 min |
| Heat Capacity Calibration Range | Up to 40,000 J |
| Outer Water Jacket Volume | Approx. 3.5 L |
| Inner Water Bucket Volume | Approx. 2.2 L |
| Operating Ambient Temperature | 20–30 °C |
| Relative Humidity Limit | ≤80 % RH |
| Protection Rating | IP20 (DIN EN 60529) |
| Power Supply | 220–240 V, 50/60 Hz, 1700 W |
| Dimensions (W × D × H) | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Cooling Medium | Tap water or external chiller (e.g., RC 2 basic) |
| Oxygen Pressure | Up to 40 bar |
| Compliance Standards | ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, GB/T 213 |
| Data Interfaces | Ethernet, RS232, USB, SD card slot |
| Optional Accessories | C6010 & C6012 decomposition bombs, RC 2 basic recirculating chiller |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Modes | Adiabatic, Isoperibol (Isothermal), Dynamic |
| Temperature Range | 22–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05% RSD (Adiabatic & Isothermal, 1 g benzoic acid NBS 39i) |
| Single-Sample Test Time | 15 min |
| Heat Capacity Calibration Range | 40,000 J |
| Cooling Circulator | RC 2 Basic |
| External Water Jacket Capacity | Not specified |
| Internal Water Jacket Capacity | Not specified |
| Max Oxygen Pressure | 40 bar |
| Cooling Medium | Tap water |
| Min Flow Rate | 60 L/h |
| Max Flow Rate | 70 L/h |
| Ambient Operating Temp | 20–25 °C |
| Relative Humidity Limit | ≤80% RH |
| Protection Class | IP20 |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Input Power | 2000 W |
| Dimensions (W×D×H) | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | ROTATEMP Package |
| Instrument Type | Rotational Viscometer Accessory System |
| Mounting Style | Benchtop Fixed Installation |
| Operating Environment | Ambient Temperature |
| Viscosity Range (with ROTAVISC) | 1–320,000,000 mPa·s |
| Max. Operating Temperature | 300 °C |
| Minimum Sample Volume | 7 mL |
| Maximum Sample Volume | 13 mL |
| Sample Vessel | Dedicated cylindrical chamber |
| Dimensions (W×D×H) | 265 × 220 × 270 mm |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % RH |
| Ingress Protection | IP40 per DIN EN 60529 |
| Interface | RS232 |
| Voltage | 220–230 V AC |
| Frequency | 50/60 Hz |
| Rated Power Input | 300 W |
| Standby Power Consumption | 1.6 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Product Type | Rotational Viscometer |
| Model | ROTAVISC hi-vi I Complete |
| Viscosity Range | 200 – 80,000,000 mPa·s |
| Temperature Range | −100 °C to 300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Measurement Range | 1.4374 mN·m |
| Full-Scale Accuracy | ±1 % FSR |
| Repeatability | ±0.2 % FSR |
| Display | 4.3″ TFT touchscreen |
| Interfaces | RS232, USB |
| Power Supply | 100–240 V AC, 50/60 Hz |
| IP Rating | IP40 |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Compliance | DIN EN 60529, CE, RoHS |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Type | Benchtop Rotational Viscometer |
| Viscosity Range | 200 – 80,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Accuracy (FSR) | ±1% |
| Repeatability (FSR) | ±0.2% |
| Motor Power | 4.8 W |
| Display | 4.3″ TFT touchscreen |
| Connectivity | RS-232, USB |
| Protection Rating | IP40 |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ROTAVISC hi-vi II Complete |
| Instrument Type | Rotational Viscometer |
| Mounting Type | Benchtop Fixed |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 800 – 320,000,000 mPa·s |
| Temperature Range | −100 – 300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Range | Up to 5.7496 mN·m |
| Full-Scale Accuracy | ±1 % FSR |
| Repeatability | ±0.2 % FSR |
| Display | 4.3″ TFT touchscreen |
| Interfaces | RS232, USB |
| Protection Rating | IP40 |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W×H×D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Type | Benchtop Rotational Viscometer |
| Viscosity Range | 800 – 320,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Range | up to 5.7496 mN·m |
| Display | 4.3″ TFT touchscreen |
| Interface | RS-232, USB |
| Compliance | DIN EN 60529 (IP40), CE, RoHS |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Weight | 7.1 kg |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Product Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–6,000,000 mPa·s |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01–200 rpm |
| Torque Accuracy (FSR) | ±1% |
| Repeatability (FSR) | ±0.2% |
| Motor Power | 4.8 W |
| Display | TFT touchscreen |
| Interfaces | RS-232, USB |
| Protection Class | IP40 |
| Dimensions (W×H×D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Operating Ambient | 0–40 °C, ≤80% RH |
| Compliance | DIN EN 60529, CE, RoHS |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Rotational Viscometer |
| Mounting Type | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 15–6,000,000 mPa·s |
| Temperature Range | −100 to 300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01–200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Accuracy (FSR) | ±1% |
| Repeatability (FSR) | ±0.2% |
| Motor Power | 4.8 W |
| Display | 4.3″ TFT Touchscreen |
| Interfaces | RS-232, USB |
| Protection Rating | IP40 |
| Dimensions (W×H×D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ROTAVISC me-vi Complete |
| Instrument Type | Benchtop Fixed-Position Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 100 – 40,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Torque Range | 0.7187 mN·m |
| Viscosity Accuracy (FSR) | ±1 % |
| Viscosity Repeatability (FSR) | ±0.2 % |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Interface | RS232, USB |
| IP Rating | IP40 |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Rotational Viscometer |
| Mounting Type | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 100 – 40,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Measurement Range | 0.7187 mN·m |
| Viscosity Accuracy (FSR) | ±1% |
| Viscosity Repeatability (FSR) | ±0.2% |
| Display | 4.3″ TFT Touchscreen |
| Interface | RS-232, USB |
| IP Rating | IP40 |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Range | ROTAVISC lo-vi / me-vi / hi-vi I / hi-vi II Complete |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–6,000,000 mPa·s |
| Temperature Control Range | −100 °C to +300 °C |
| Temperature Resolution | 0.1 K |
| Accuracy | ±1 % of full scale |
| Repeatability | ±0.2 % of full scale |
| Speed Control | Continuously Variable (0.01–1,000 rpm) |
| Brand | IMCE |
|---|---|
| Origin | Belgium |
| Model | HT1600-DS |
| Sample Capacity | 2 simultaneous specimens |
| Operating Temperature Range | Up to 1600 °C |
| Optional Vertical Dilatometer Integration | Yes |
| Compliance | ASTM E1876, ISO 12680, DIN 51045 |
| Brand | IMCE |
|---|---|
| Model | HTVP1600/1700C (HT1050/1600/1700) |
| Operating Temperature Range | Ambient to 1600 °C / 1700 °C |
| Temperature Stability | ±1 °C |
| Heating Rate | 0.1–20.0 °C/min |
| Resonance Frequency Range | 10 Hz–150 kHz (±0.5 Hz) |
| Damping/Internal Friction Measurement Range | 1×10⁻⁵–0.1 |
| Elastic Modulus Accuracy | <0.1% at RT, <5% at elevated temperature |
| Elastic Modulus Range | 10 MPa–880 GPa |
| Shear Modulus & Poisson’s Ratio | Calculated from resonance spectra |
| Atmosphere Control | Inert, oxidizing, reducing, vacuum-compatible |
| Detection Method | Non-contact laser Doppler vibrometry |
| Compliance | ASTM E1876, ASTM C1259 |
| Brand | IMCE |
|---|---|
| Model | HTVP1600C |
| Measurement Principle | Resonant Frequency Method |
| Frequency Range | 1–100 kHz |
| Damping Factor (tan δ) | 1×10⁻⁵ to 0.1 |
| Temperature Range | Ambient to 1600 °C |
| Atmosphere Control | Yes |
| Compliance | ASTM E1876-99 |
| Output Parameters | Young’s Modulus, Shear Modulus, Poisson’s Ratio, Internal Friction (Q⁻¹) |
| Brand | IMCE |
|---|---|
| Model | HTVP650C |
| Measurement Principle | Impulse Excitation Technique (IET) / Resonance Frequency Analysis |
| Frequency Range | 1–100 kHz |
| Elastic Modulus Accuracy | < ±0.1% |
| Repeatability | < ±0.2% |
| Damping Resolution | down to 1×10⁻⁵ |
| Sample Dimensions | Length 20–300 mm, Width 2–130 mm |
| Maximum Operating Temperature | 650 °C (upgradable to 1100 °C) |
| Compliance | ASTM C1259, ASTM E1187 |
| Software | Integrated IET data acquisition & analysis suite with temperature correlation module |
| Excitation | Automated electromagnetic impulse system |
| Data Output | Young’s modulus (E), Shear modulus (G), Poisson’s ratio (ν), Resonant frequencies (f₁, f₂, …), Internal friction (Q⁻¹) |
| Brand | IMCE |
|---|---|
| Model | RFDA MF Professional |
| Origin | Belgium |
| Application | Non-destructive dynamic mechanical characterization of ceramics, metals, and advanced materials |
| Temperature Range | Ambient to 1750 °C |
| Atmosphere Control | Yes |
| Damping Measurement Range | 1×10⁻⁵ to 0.1 (dimensionless) |
| Measured Parameters | Resonant frequency, elastic modulus (E), shear modulus (G), Poisson’s ratio (ν), internal damping (Q⁻¹ or tan δ) |
| Compliance | ASTM E1876, ISO 12680, DIN 51045-1, applicable to GLP/GMP environments with audit trail enabled in RFDA MF Software |
| Key | Brand: OEM / Third-Party Industrial Supplier |
|---|---|
| Origin | Imported (Non-US/EU Designated Origin) |
| Manufacturer Type | Authorized Distributor |
| Quoted Price | USD 16,800 (FOB Origin, Excluding VAT, Freight & Installation) |
| Key | Table Surface Dimensions: 200 × 200 mm |
|---|---|
| Maximum Payload | 10 kg |
| Pulse Duration Range | 0.2–100 ms (programmable, auto-controlled) |
| Peak Acceleration Range | 50–9999 m/s² (programmable, auto-controlled) |
| Pulse Waveform | Half-sine (compliant with IEC 60068-2-27, GB/T 2423.5, GJB 150.18A, GJB 360B, JJG 497) |
| Shock Direction | Vertical |
| Dual-Impact Prevention | Hydraulic-friction braking system |
| Height Control | Digital preset + hydraulic lifting |
| Sampling Rate | 200 kHz |
| Signal Conditioning | Analog filtering + 160 dB/oct digital anti-aliasing filter |
| Repetition Rate | 0–100 shocks/min (±1% accuracy) |
| Power Supply | AC 380 V ±10%, 50 Hz, 3 kVA |
| System Mass | 2800 kg |
| Overall Dimensions | 750 × 2600 × 1000 mm |
| Software Platform | Windows XP-based, DAO data engine, automated Word report generation, real-time display of lift height, peak acceleration, pulse width, and Δv |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,000–42,000 (FOB) |
| Load Capacity | 10–100 kg |
| Table Size | 20×20 to 80×65 cm |
| Acceleration Range | 150–15,000 m/s² |
| Pulse Duration | 0.5–30 ms |
| Waveform Options | Half-sine, Trapezoidal, Post-peak Sawtooth |
| Power Supply | AC 380 V ±5%, 50/60 Hz, 3-phase 5-wire |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,000–70,000 (FOB) |
| Compliance Standards | MIL-STD-810H, IEC 60068-2-29, GB/T 2423.5–2022, GB/T 2423.6–2022, GJB 150.18A–2009, GJB 360B–2009 |
| Waveform Options | Half-sine, Trapezoidal, Post-peak Sawtooth |
| Control Mode | Closed-loop Acceleration Control for Collision Mode |
| Drive System | DC Motor + Precision Gear Reducer + Roller-Lift Mechanism |
| Pulse Duration Range | 1.5–25 ms |
| Peak Acceleration Range | 25–1200 m/s² |
| Drop Height Range | 0–200 mm |
| Repetition Rate | 1–120 impacts/min |
| Operating Pressure | 0.7–0.8 MPa (7–8 kgf/cm²) |
| Power Supply | AC 220 V ±5%, 50 Hz ±0.5 Hz, Single-phase Three-wire |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 3,950 (FOB) |
| Temperature Range | 105–132 °C (Control Point) |
| Temperature Uniformity | ±2.0 °C |
| Temperature Stability | ±0.5 °C |
| Humidity Range | 75–100% RH (Control Point) |
| Humidity Stability | ±2.5% RH |
| Humidity Uniformity | ±5.0% RH |
| Pressure Range | 0.05–0.196 MPa (0.5–2.0 kgf/cm²) |
| Ramp Time (Ambient → 132 °C) | ≤35 min |
| Pressure Ramp Time (Atmospheric → 2.0 kgf/cm²) | ≤40 min |
| Cooling System | Dual-Circuit Refrigeration with Eco-Friendly Refrigerant (R-404A or R-507) |
| Condenser Type | Air-Cooled with Forced-Air Heat Dissipation or Optional Water-Cooled Coil |
| Vacuum Preconditioning | Integrated Vacuum Pump with Filtered Air Recharge |
| Control Interface | LED Digital Timer with Start-on-Temp Trigger Logic |
| Safety | Dual-Limit Over-Temp/Over-Pressure Protection, Fault Indicator LEDs, Auto-Shutdown on Anomaly |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 3,500 (approx.) |
| Compliance Standards | MIL-STD-810G Method 512.6 (Rain), IEC 60529 IPX1–IPX6, ISO 20653, GB/T 4208, GB/T 2423.38, GJB 150.8, IEC 60068-2-68, GB/T 4942.1, IEC 60034-5 |
| Chamber Construction | SUS304 Stainless Steel Interior |
| Insulation | Rigid Polyurethane Foam + Glass Fiber |
| Turntable | PVC Hardboard Surface (Corrosion-Resistant) |
| Water-Contact Components | Stainless Steel or Brass |
| Control System Options | Programmable Logic Controller (PLC) or Full-Color Touchscreen HMI (proprietary developed) |
| Oscillation Mechanism | Stepper Motor-Driven Swing Pipe with Adjustable Angle & Sweep Rate |
| Nozzle Layout | Radial Arrangement Centered on Turntable Axis |
| Post-Test Drying | Compressed Air Blow-Off |
| Water Level | Motorized Auto-Adjustment |
| Spray System | High-Pressure Pump + Heated Spray Nozzles |
| External Casing | 1.2 mm Cold-Rolled A3 Steel, CNC Formed, Powder-Coated Finish |
| Noise Level | <65 dB(A) |
| Energy Efficiency | Optimized Thermal Management & Duty-Cycle Control |
| Brand | Innovatest |
|---|---|
| Country of Origin | Netherlands |
| Manufacturer | Innovatest B.V. |
| Type | Rockwell Hardness Tester |
| Measurement Range | 10–100 HR |
| Total Test Force | 187.5 kgf |
| Test Space | 650 mm (H) × 175 mm (D) |
| Nose Extension Length | 170 mm |
| Test Table Dimensions | 425 mm × 370 mm (with hardened zone & T-slots) |
| Preload Forces | 3 kgf, 10 kgf |
| Main Load Range | 15–150 kgf |
| Loading System | Fully Automatic, Load Cell-Based Closed-Loop Control |
| Guidance System | Full-Height Linear Rails + Precision Ball-Screw Drive |
| Display | 6.5″ Industrial Touchscreen |
| Software | I-TOUCH™ Hardness Control Suite |
| Data Storage | Internal Memory (up to 150 readings) |
| Interface | USB |
| Illumination | Integrated LED Surface Lighting |
| Base Enclosure | Interchangeable ABS Protective Housing |
| Brand | INNOVATEST |
|---|---|
| Origin | Netherlands |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | NEXUS 3001XLM-IMP |
| Test Force Range | 30 kgf to 3000 kgf |
| Z-Axis Travel | 345 mm |
| Specimen Height Clearance | 335 mm |
| Depth Clearance | 220 mm |
| Turret | 2-position (indenter + Brinell objective with annular LED illumination) |
| Imaging System | 5 MP full-HD camera with motorized zoom and auto-focus |
| Control Interface | IMPRESSIONS™ software on 15″ industrial touchscreen |
| Measurement Method | Automated video-based indent diameter analysis per ISO 6506-1 and ASTM E10 |
| Brand | INNUO |
|---|---|
| Origin | Shanghai, China |
| Model | YND-OM4 |
| Temperature Range | RT to 500 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating/Cooling Rate | 0.1–80 K/min |
| Sample Capacity | Up to 8 samples per run (configurable for 4/6/8) |
| DSC Range | 0 to ±500 mW |
| DSC Resolution | 0.01 mW |
| DSC Sensitivity | 0.01 mW |
| Gas Control | Dual-channel mass flow control (N₂/O₂), 0–200 mL/min, accuracy ±0.2 mL/min |
| Power Supply | AC 220 V, 50 Hz |
| Interface | Integrated USB 2.0 |
| Display | 7-inch color capacitive touchscreen |
| Compliance | GB/T 19466.3–2009 / ISO 11357-3:1999 (OIT determination) |
| Brand | INPROCESS-LSP |
|---|---|
| Origin | Netherlands |
| Model | NanoFlowsizer |
| Particle Size Range | 10–1000 nm |
| Size Reproducibility | ±2 nm |
| Temperature Range | −10 to 125 °C |
| Temperature Control Accuracy | ±0.5 °C (−10 to 85 °C), ±2.0 °C (85 to 125 °C) |
| Optical Signal Frequency | 76 Hz |
| Measurement Principle | Spatially Resolved Dynamic Light Scattering (SR-DLS) |
| Sample Concentration Range | Unrestricted |
| Minimum Sample Volume | ≥100 µL |
| Zeta Potential Range | Not applicable (dedicated particle sizing only) |
| Measurement Time | <10 s per acquisition |
| Brand | Insment |
|---|---|
| Model | KS-118D |
| Origin | Shanghai, China |
| Radiation Source Power | 500 W |
| Radiation Surface Diameter | Φ100 mm ± 5 mm |
| Sample Holder Inner Diameter | 118 mm (stainless steel ring) |
| Stainless Steel Mesh | Wire diameter 0.70 mm, aperture 2.10 mm |
| Sample Dimensions | 70 mm × 70 mm, max thickness 13 mm |
| Drip Catcher Diameter | Φ118 mm, depth 12 mm |
| Distance from Sample Upper Surface to Radiant Source | 30 mm |
| Distance from Sample Holder to Drip Catcher (cotton pad) | 300 mm |
| Heat Flux Meter Range | 10 W/cm² |
| Overall Dimensions | 1120 mm (W) × 580 mm (D) × 1350 mm (H) |
| Exhaust Port Diameter | Φ100 mm |
| Power Supply | AC 220 V, 50 Hz, ≤1000 W |
| Compliance | UN ECE Regulation No. 118, Annex 7 |
| Brand | Instron |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 9400 Series |
| Pricing | Available Upon Request |