Physical Property Testing Instruments
Filter
Showing 331–360 of 12188 results
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DMA 1002/1102 Petro |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Category | Portable |
| Sample Type | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Temperature Range | 15 °C to 100 °C (59 °F to 212 °F) |
| Temperature Accuracy | ±0.03 °C (from +15 °C to +100 °C) |
| Density Resolution | 5 significant digits |
| Viscosity Range (DMA 1102 only) | –0.3 mm²/s to 1000 mm²/s |
| Viscosity Repeatability | ±0.2% |
| Minimum Sample Volume | 3.5 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP touch screen |
| Dimensions (L×W×H) | 365 mm × 265 mm × 180 mm |
| Weight | 6.6 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 1102 Petro |
| Instrument Type | Oscillating U-tube Densimeter |
| Application | Petroleum Products Density & Kinematic Viscosity Measurement |
| Detection Medium | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Resolution | 5 significant digits |
| Temperature Range | 15 °C to 100 °C (59 °F to 212 °F) |
| Temperature Stability | ±0.03 °C over full range |
| Viscosity Range | −0.3 mm²/s to 1000 mm²/s |
| Viscosity Repeatability | ±0.2% |
| Minimum Sample Volume | 3.5 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Dimensions (L×W×H) | 365 × 265 × 180 mm |
| Weight | 6.6 kg |
| Power Supply | DC 24 V / 3 A |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DMA 35 |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Portable |
| Sample State | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ (for samples with viscosity < 300 mPa·s and density < 2 g/cm³) |
| Temperature Range | 0 °C to 40 °C (32 °F to 104 °F) |
| Repeatability (std. dev.) | ±0.0005 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 2 mL |
| Environmental Rating | IP54 |
| ATEX/IECEx Certification | II 2G Ex ib IIB T4 Gb (DMA 35 Ex & DMA 35 Ex Petrol variants) |
| Compliance | ASTM D7777, IP 559 |
| Connectivity | Bluetooth® 4.2, RFID reader (integrated) |
| Data Storage | Up to 1,200 measurements, 250 sample IDs, 30 user-defined methods |
| Power | 3 × 1.5 V LR06 AA alkaline batteries |
| Weight | 660 g |
| Dimensions (L×W×H) | 245 mm × 103 mm × 126 mm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 4002 / DMA 5002 / DMA 6002 |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Class | Benchtop Laboratory Densimeter |
| Sample Type | Liquid |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±0.00005 g/cm³ (DMA 4002), ±0.00001 g/cm³ (DMA 5002, 0–1.05 g/cm³ at 15–20 °C), ±0.000005 g/cm³ (DMA 6002, full range) |
| Temperature Range | 0 °C to 100 °C |
| Temperature Accuracy | ±0.02 °C (DMA 4002), ±0.01 °C (DMA 5002 & DMA 6002, 15–20 °C) |
| Density Repeatability (Std. Dev.) | 0.00001 g/cm³ (DMA 4002), 0.000003 g/cm³ (DMA 5002), 0.000001 g/cm³ (DMA 6002) |
| Density Resolution | 0.00001 g/cm³ (DMA 4002), 0.000005 g/cm³ (DMA 5002), 0.000001 g/cm³ (DMA 6002) |
| Minimum Sample Volume | 1 mL |
| Display | 10.1″ TFT WXGA (1280 × 800 px) PCAP Touchscreen |
| Compliance | ASTM D4052, D5002, D1250 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA 4100 M |
| Instrument Type | Laboratory Benchtop Oscillating Tube Densitometer |
| Sample Type | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Temperature Range | 0 °C to 100 °C |
| Temperature Accuracy | ±0.03 °C |
| Density Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 1 mL |
| Measurement Time (after thermal equilibration) | 30 s |
| Repeatability (σ) | 0.00001 g/cm³ |
| Reproducibility (σ) | 0.00005 g/cm³ |
| Operating Pressure | up to 10 bar |
| Display | 10.4" TFT PCAP Touchscreen (640 × 480 px) |
| Interfaces | 4× USB, RS-232, CAN, VGA, Ethernet |
| Data Storage | 1000 measurements (circular buffer optional) |
| Wetted Materials | PTFE, borosilicate glass |
| Dimensions (L×W×H) | 495 × 330 × 230 mm |
| Weight | 22.5 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Instrument Type | Laboratory Benchtop Oscillating Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | 0.0001 g/cm³ (DMA 4100M) / 0.00005 g/cm³ (DMA 4500M) / 0.000005 g/cm³ (DMA 5000M) |
| Temperature Range | 0 °C to 95 °C |
| Temperature Accuracy | ±0.05 °C (4100M) / ±0.03 °C (4500M) / ±0.01 °C (5000M) |
| Minimum Sample Volume | 1 mL |
| Repeatability (Std. Dev.) | 0.00005 g/cm³ (4100M) / 0.00001 g/cm³ (4500M) / 0.000001 g/cm³ (5000M) |
| Display | 10.4" PCAP TFT Touchscreen (640 × 480 px) |
| Compliance | FDA 21 CFR Part 11, GLP/GMP, ISO 12084, ASTM D4052, USP <841> |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA 4200 M |
| Instrument Type | Laboratory Benchtop Oscillating Tube Densitometer |
| Sample Type | Liquids |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0002 g/cm³ (at ambient pressure, ideal conditions) |
| Density Repeatability | ±0.00005 g/cm³ (std. dev., ISO 5725) |
| Density Reproducibility | ±0.0001 g/cm³ (std. dev., ISO 5725) |
| Density Resolution | 0.00001 g/cm³ |
| Temperature Range | –10 °C to +200 °C (14 °F to 392 °F) |
| Pressure Range | 0–500 bar (0–7250 psi) |
| Minimum Sample Volume | 2 mL |
| Temperature Accuracy | ±0.03 °C |
| Temperature Repeatability | ±0.01 °C |
| Viscosity Correction | Automatic, real-time, pressure- and temperature-compensated |
| Filling Verification | FillingCheck™ (ASTM D4052 / GB/T 29617 / ASTM D5002 compliant) |
| Thermal Equilibration Technology | Temperfect™ (enables immediate density measurement at any temperature from 0 °C to 150 °C under ambient pressure) |
| Excitation Method | Patented Pulsed Excitation Method (AT 516420 B1) |
| Cell Material | Hastelloy® C-276 |
| Dimensions | 510 mm × 330 mm × 380 mm (W × D × H) |
| Power Supply | AC 100–240 V, 50–60 Hz, 250 VA |
| Interfaces | 4× USB 2.0, 1× Ethernet (100 Mbit), 1× CAN Bus, 1× RS-232, 1× VGA |
| Wetted Parts | Hastelloy C-276 only |
| Compliance | ASTM D4052, ASTM D5002, GB/T 29617, ISO 12185, ISO 16554 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA 4200 M |
| Instrument Type | Laboratory Benchtop Oscillating Tube Densitometer |
| Sample Type | Liquid (including high-viscosity, solid-at-room-temperature, and pressurized samples) |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Repeatability | ≤0.00005 g/cm³ (standard deviation) |
| Temperature Range | −10 °C to +200 °C (14 °F to 392 °F) |
| Temperature Accuracy | ±0.03 °C |
| Pressure Range | 0–500 bar (0–7,250 psi) |
| Minimum Sample Volume | 2 mL |
| Measuring Cell Material | Hastelloy C-276 |
| Cell Volume | ~2 mL |
| Dimensions | 510 × 330 × 230 mm (20 × 13 × 8.7 in) |
| Weight | 27.1 kg (59.7 lb) |
| Power Supply | AC 100–240 V, 50–60 Hz, 250 VA |
| Interfaces | 4 × USB 2.0, 2 × S-Bus, 1 × Ethernet (100 Mbit), 1 × CAN Bus, 1 × RS-232, 1 × VGA |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 4200M |
| Instrument Type | Oscillating U-Tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0002 g/cm³ |
| Density Repeatability (s.d.) | ±0.00005 g/cm³ |
| Digital Resolution | 0.00001 g/cm³ |
| Temperature Range | −10 °C to 200 °C (14 °F to 392 °F) |
| Pressure Range | 0–500 bar (7250 psi) |
| Minimum Sample Volume | 2 mL |
| Viscosity Correction | Fully Automated, Real-Time |
| Filling Verification | FillingCheck™ |
| Thermal Equilibration Technology | Temperfect™ |
| Oscillation Excitation Method | Pulsed Excitation Method (Patent AT 516420 B1) |
| Wetted Materials | Hastelloy C-276 |
| Compliance Standards | ASTM D4052, ASTM D5002, GB/T 29617 |
| Power Supply | AC 100–240 V, 50–60 Hz, 250 VA |
| Interface Ports | 4× USB 2.0, 1× Ethernet (100 Mbit), 1× CAN Bus, 1× RS-232, 1× VGA, 1× 1/8″ OD metal pressure fitting |
| Brand | Anton Paar |
|---|---|
| Origin | Japan (manufactured in Austria) |
| Model | DMA 5001 |
| Instrument Type | Laboratory Benchtop Densitometer |
| Sample Type | Solid & Liquid Compatible |
| Measurement Principle | Oscillating U-tube (ASTM D4052, ISO 12185, USP <841>) |
| Density Range | 0 to 3 g/cm³ |
| Temperature Range | 0 °C to 100 °C |
| Accuracy (Density) | ±0.000005 g/cm³ |
| Repeatability (Density) | ±0.000001 g/cm³ |
| Minimum Sample Volume | ~1 mL |
| Display | 10.1″ TFT WXGA Touchscreen (1280 × 800 px) |
| Data Storage | >10,000 measurements with embedded camera images |
| Measurement Time | ≤40 s per sample |
| Operating System | Real-time embedded OS (8× faster than previous generation) |
| CPU | Dual-core processor (2× speed increase) |
| Compliant | FDA 21 CFR Part 11, GLP/GMP audit trail, ISO/IEC 17025 traceability support |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA 501 |
| Instrument Type | Benchtop Oscillating Tube Densitometer |
| Sample Type | Liquids, Suspensions, Emulsions, Pastes, Aerosols |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | 15–40 °C |
| Temperature Accuracy | ±0.3 °C |
| Repeatability (Std. Dev.) | ±0.0002 g/cm³ |
| Reproducibility (Std. Dev.) | ±0.0004 g/cm³ |
| Minimum Sample Volume | 1 mL |
| Viscosity Correction | Full-range automatic |
| Compliance | ISO 5725, ASTM D4052, ISO 12185, USP <841>, GLP/GMP-ready |
| Dimensions (L×W×H) | 375 × 265 × 180 mm |
| Weight | 13.5 kg |
| Display | 7″ TFT WVGA Touchscreen (800 × 480 px) |
| Connectivity | Ethernet, 3× USB, RS232 |
| Data Storage | 5,000 measurements |
| Environmental Monitoring | Integrated temperature/humidity/pressure sensors |
| Optional Accessories | Aerosol adapter, peristaltic pump, paste sampling kit, ISO calibration certificate |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 502 |
| Instrument Type | Oscillating U-tube Density Meter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids and Low-Viscosity Suspensions |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability | ±0.0002 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | 15–40 °C |
| Temperature Stability | ±0.1 °C |
| Minimum Sample Volume | 1 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Environmental Compensation | Automatic pressure, altitude, and ambient humidity correction |
| Data Storage | 5000 measurements |
| Method Library | 400 pre-validated methods |
| Conversion Tables | 140 built-in (alcohol, sugar, acids, API gravity, etc.) |
| Compliance | ASTM D4052, ASTM D5002, USP <841>, EP/JP pharmacopoeial density requirements, FDA 21 CFR Part 11 (when used with AP Connect) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids and Semi-solids (with optional kits) |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | 0.001 g/cm³ (DMA 502), 0.0001 g/cm³ (DMA 1002) |
| Density Repeatability | 0.0002 g/cm³ (DMA 502), 0.00005 g/cm³ (DMA 1002) |
| Temperature Range | 5–35 °C (ambient), 15–40 °C (measurement, DMA 502), 15–60 °C (measurement, DMA 1002) |
| Temperature Resolution | 0.01 °C |
| Minimum Sample Volume | ~1 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP capacitive touchscreen |
| Dimensions (L×W×H) | 375 × 280 × 180 mm |
| Weight | 13.5 kg |
| Connectivity | 1× Ethernet, 3× USB, 1× RS232 |
| Data Storage | 5000 measurements, 400 user-defined methods, 140 built-in conversion tables |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DMA 6002 Sound Velocity |
| Instrument Type | Oscillating U-tube Densimeter & Sound Velocity Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Sound Velocity Range | 1000 m/s to 2000 m/s |
| Temperature Range | 0 °C to 100 °C (32 °F to 212 °F) |
| Pressure Range | 0 bar to 8 bar (0 psi to 116 psi) |
| Density Accuracy | ±0.000005 g/cm³ |
| Density Repeatability (Std. Dev.) | ±0.000001 g/cm³ |
| Sound Velocity Repeatability (Std. Dev.) | ±0.1 m/s |
| Density Reproducibility (Std. Dev.) | ±0.000005 g/cm³ |
| Sound Velocity Reproducibility (Std. Dev.) | ±0.5 m/s |
| Density Resolution | 0.000001 g/cm³ |
| Sound Velocity Resolution | 0.01 m/s |
| Minimum Sample Volume | 3.5 mL |
| Measurement Throughput | Up to 30 samples/hour |
| Compliance | ISO 5725, ASTM D4052, ASTM D1250, ISO 12185, ISO 17025 (when operated with certified calibration standards) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | HPM |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Phase | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Repeatability | ≤0.00001 g/cm³ (standard deviation) |
| Temperature Range | −10 to +200 °C |
| Pressure Range | 0–1400 bar (0–20,300 psi) |
| Minimum Sample Volume | ~2 mL |
| Cell Material | Hastelloy C-276 |
| Digital Resolution | 0.00001 g/cm³ |
| Interface | 1/4″ metal tubing compression fittings |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA35 |
| Instrument Type | Portable Digital Density Meter |
| Measurement Principle | Oscillating U-tube (OUM) |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability (std. dev.) | ±0.0005 g/cm³ |
| Temperature Range (Sample) | 0–40 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Repeatability | ±0.1 °C |
| Sample Volume | 1–2 mL |
| Resolution | 0.0001 g/cm³ (density), 0.1 °C (temperature) |
| Environmental Operating Range | −10 to +50 °C (standard) |
| Protection Rating | IP54 |
| ATEX/IECEx Certification | II 2G Ex ib IIB T4 Gb (DMA35 Ex & DMA35 Ex Petrol) |
| Data Storage | 1024 measurements, 30 methods, 250 sample IDs |
| Interface | Bluetooth®, RFID, IrDA |
| Power Supply | 3 × AA alkaline batteries (LR06) |
| Weight | 660 g |
| Dimensions (L×W×H) | 245 × 103 × 126 mm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA35 |
| Instrument Type | Portable Oscillating Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | 0–40 °C (operational range: −10 to +50 °C) |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Density Repeatability | ±0.0005 g/cm³ |
| Minimum Sample Volume | 1–2 mL |
| Viscosity Limit | ≤100 mPa·s (for samples <2 g/cm³) |
| Data Storage Capacity | 1024 measurements |
| Communication Interfaces | IrDA infrared, RFID (Tag&Log version only) |
| Ingress Protection Rating | IP54 |
| Power Supply | 2 × AA alkaline batteries (1.5 V) |
| Dimensions | 140 × 138 × 27 mm |
| Weight | 368 g |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Portable Oscillating U-Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability | ±0.0005 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range (Measurement) | 0–40 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Repeatability | ±0.1 °C |
| Minimum Sample Volume | 1–2 mL |
| Operating Ambient Temperature | −10 to +50 °C |
| IP Rating | IP54 |
| Intrinsic Safety Certification | Ex II 2 G Ex ib IIC T4 (Ex and Ex Petrol versions) |
| Data Storage | 1024 measurements, 30 methods, 250 sample IDs |
| Connectivity | Bluetooth® v4.2, RFID reader (integrated) |
| Power Supply | 3 × AA LR06 alkaline batteries (1.5 V) |
| Weight | 660 g |
| Dimensions (L×W×H) | 245 × 103 × 126 mm |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA35 Standard |
| Instrument Type | Oscillating U-tube Density Meter |
| Portability | Portable |
| Sample Type | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Temperature Range | 0 °C to 40 °C |
| Minimum Sample Volume | 2 mL |
| Compliance | ASTM D7777, IP 559 |
| Explosion Protection | Ex II 2 G Ex ib IIB T4 (DMA35 Ex & DMA35 Ex Petrol variants) |
| Data Storage | Up to 1024 measurements with timestamp and sample ID |
| Connectivity | Bluetooth® v4.2, RFID interface, USB-C for charging/data backup |
| Display | Capacitive touchscreen with auto-rotation and backlighted viewing window |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DMA35N |
| Accuracy | ±0.001 g/cm³ |
| Measurement Range | 0 to 1.999 g/cm³ |
| Temperature Range | 0 to 40 °C (operational), sample temperature up to 100 °C |
| Minimum Sample Volume | 2 mL |
| Weight | 275 g |
| Power Supply | Rechargeable battery |
| Interface Options | RS232 or infrared |
| Data Storage Capacity | 1024 measurements |
| Built-in Concentration Tables | H₂SO₄, Brix, % alcohol (v/v and w/w), API gravity, others |
| Automatic Temperature Compensation | Yes |
| Pump Type | Integrated high-performance micro-pump |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Instrument Type | Rotational Rheometer |
| Model | FRS 1600 |
| Sample State | Liquid (molten) |
| Bearing Type | Air-bearing |
| Minimum Rotational Speed | 10⁻⁹ rpm |
| Frequency Range | 10⁻⁷ – 628 rad/s |
| Maximum Rotational Speed | 300 rpm |
| Maximum Torque | 230 mNm |
| Torque Resolution | 1 nNm |
| Temperature Range | 300–1600 °C |
| Compliance | ASTM C965, ISO 7884-2 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Instrument Type | Rotational Rheometer |
| Bearing Type | Air Bearing |
| Temperature Range | 300–1530 °C |
| Minimum Rotational Speed | 10⁻⁹ rpm |
| Maximum Rotational Speed | 300 rpm |
| Frequency Range | 10⁻⁷–628 rad/s |
| Maximum Torque | 230 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.005–50 N |
| Normal Force Resolution | 0.5 mN |
| Sample Cup Max Height | 100 mm |
| Measuring System Materials | Al₂O₃, Graphite, Pt, Custom Options |
| Compliance | ASTM C965, ISO 7884-2 |
| Dimensions (W×H×D) | 680 × 1950 × 920 mm |
| Weight | 120 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | FRS 1800 |
| Instrument Type | Rotational Rheometer |
| Sample Type | Solids, Melts, Slags, Glasses, Ceramics |
| Motor Bearing | Air Bearing |
| Temperature Range | 20 °C to 1730 °C (up to 1800 °C with optional furnace configuration) |
| Frequency Range | 10⁻⁷ to 628 rad/s |
| Minimum Angular Velocity | 10⁻⁹ rad/s |
| Maximum Angular Velocity | 314 rad/s (300 rpm) |
| Maximum Torque | 230 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.005–50 N |
| Normal Force Resolution | 0.5 mN |
| Viscosity Range | 10⁻³ to 10⁷ Pa·s |
| Angular Displacement Setpoint | 0.1 µrad to ∞ |
| Angular Displacement Resolution | 10 nrad |
| Measurement Head Max Speed | 3000 rpm |
| Furnace Cooling | Dual-mode (gas + water) |
| Atmosphere Options | Air, N₂, Ar, He |
| Compliance | ASTM C965, ISO 7884-2 |
| Measuring System Materials | Al₂O₃, Graphite, Pt, Custom Alloys |
| Rotor Diameter | 11–27.6 mm |
| Sample Cup Height (max) | 100 mm |
| Dimensions (W × H × D) | 680 × 1950 × 920 mm |
| Weight | 150 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Piezo Sample Stage 100 μm × 100 μm |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Rotational Rheometer |
| Sample Viscosity Range | High-Viscosity Liquids |
| Temperature Range | –160 °C to +1000 °C |
| Frequency Range | 0.001–628 rad/s |
| Maximum Rotational Speed | 2100 rpm |
| Bearing System | Precision Multi-Pore Carbon Air Bearing |
| Sample Capacity | Up to 54 Samples |
| Automation Level | Fully Automated, Barcode-Enabled, Integrated Cleaning & Temperature Control |
| Compliance | Designed for GLP/GMP environments |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | HTR 7000 |
| Instrument Type | Rotational Rheometer |
| Sample Viscosity Range | Low-viscosity, paste-like, and dispersible solid samples |
| Drive Motor | Brushless DC Permanent Magnet Synchronous EC Motor |
| Maximum Torque | 230 mNm |
| Minimum Torque (Rotational Mode) | 1 nNm |
| Minimum Torque (Oscillatory Mode) | 0.05 nNm |
| Maximum Angular Velocity | 314 rad/s |
| Maximum Angular Frequency | 628 rad/s |
| Normal Force Range | 0.005 N to 50 N |
| Dimensions (W × D × H) | Approx. 1650 mm × 1500 mm × 1980 mm |
| Weight (Net) | ~1000 kg |
| Power Supply | 400 V, 16 A, 50/60 Hz |
| Interface | Ethernet |
| Pneumatic Interface | Compressed air |
| Fluid Interface | Solvent supply & waste drainage |
| Safety | Integrated safety door, ventilation monitoring, optional explosion-proof configuration |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | HTR |
| Instrument Type | Rotational Rheometer |
| Sample State | Liquid, Paste, Polymer Melt |
| Bearing Type | Air Bearing |
| Maximum Torque | 230 mNm |
| Minimum Torque (Rotational) | 1 nNm |
| Minimum Torque (Oscillatory) | 0.05 nNm |
| Max Angular Velocity | 314 rad/s |
| Max Angular Frequency | 628 rad/s |
| Normal Force Range | 0.005–50 N |
| Dimensions (W×D×H) | 1800 × 1200 × 2000 mm |
| Net Weight | 900 kg |
| Power Supply | 400 V, 16 A, 50/60 Hz |
| Interface | Ethernet |
| Pneumatic Interface | Compressed Air |
| Fluid Interface | Cleaning Solvent Inlet & Waste Drain |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Julia DSC 300/500 |
| Instrument Type | Heat-Flux DSC |
| Special Function | Modulated DSC (MDSC®-compatible operation) |
| Simultaneous Sample Capacity | Up to 70 samples (with auto-sampler) |
| Temperature Range | –170 °C to 700 °C |
| Programmable Temperature Control | Dynamic and Isothermal modes |
| Temperature Accuracy | <0.1 K |
| Temperature Precision | 0.01 °C |
| Heating Rate | 0–300 K/min |
| Cooling Rate | 0–200 K/min |
| DSC Signal Range | ±2500 mW |
| Temperature Stability | ±0.1 °C (peak-to-peak, over 30 min) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Julia DSC |
| Instrument Type | Heat-Flux DSC |
| Special Function | Modulated DSC (MDSC®-compatible) |
| Simultaneous Sample Capacity | Up to 70 samples (with auto-sampler) |
| Temperature Range | −170 °C to 700 °C |
| Temperature Accuracy | < 0.1 K |
| Temperature Precision | 0.01 °C |
| Heating Rate | 0–300 K/min |
| Cooling Rate | 0–200 K/min |
| DSC Signal Range | ±2500 mW |
| Temperature Stability | ±0.1 °C |
| Control Modes | Dynamic & Isothermal |
| Measurement Principle | Heat-Flux Differential Scanning Calorimetry |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Litesizer |
| Particle Size Range | 0.3 nm – 10 µm |
| Size Measurement Repeatability | ±2% |
| Temperature Control Accuracy | ±0.2 °C |
| Sample Concentration Range | 0.1 mg/L – 100 mg/L |
| Sample Volume Range | 12 µL – 1000 µL |
| Zeta Potential Range | −500 mV to +500 mV |