| Brand | Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | UPK-T48 |
| Instrument Type | Digital |
| Inspection Method | Pulse-Echo |
| Waveform Type | Pulsed Ultrasonic |
| Scan Envelope | 1200 × 900 × 600 mm |
| Gain Range | 0–110 dB |
| Vertical Linearity | ≤2% |
| Horizontal Linearity | ≤2% |
| Dynamic Range | ≥95 dB |
| Transducer Configuration | Single-Crystal or Through-Transmission |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Manufacturer | Analysis GmbH |
| Origin Category | Imported |
| Model | UX20 |
| Price | Upon Request |
| Detector Type | Flat-Panel Detector |
| Scanning Mode | Translation-Rotation (TR) |
| Accuracy | Micron-Level |
| Sample Load Capacity | 100 kg |
| Dimensions (W×D×H) | 2240 × 1770 × 2350 mm |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Manufacturer | Analysis GmbH |
| Origin Category | Imported |
| Model | UX50 |
| Pricing | Upon Request |
| Detector Type | Flat-Panel Detector (FPD) |
| Scanning Mode | Translation-Rotation (TR) |
| Accuracy | Micron-Level |
| Maximum Sample Weight | 100 kg |
| Dimensions (L×W×H) | 2250 × 1770 × 2350 mm |
| Brand | Analysis |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Price | Upon Request |
| Operating Temperature Range | -200 °C to +350 °C |
| Battery Life | 3–4 years (typical continuous operation) |
| Communication Protocols | WirelessHART (IEC 62591), Zigbee |
| Channels | 4 independent ultrasonic measurement channels |
| Environmental Rating | IP67-rated enclosure |
| Dual-Sensor Capability | Simultaneous thickness + ambient temperature measurement |
| Probe Compatibility | Single-crystal and dual-crystal ultrasonic transducers |
| Data Transmission | Secure, encrypted wireless transmission to local SCADA or cloud-based asset integrity platforms |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Model | Y.cougar |
| Detector Type | Flat-panel Detector |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | Up to 2.5 lp/mm |
| Density Resolution | 0.2–0.5% |
| X-ray Energy | 160 kV |
| Penetration Capability | Up to 350 mm steel-equivalent thickness |
| Accuracy | Nanoscale |
| Application Modes | 2D Radiography, 3D Computed Tomography (CT), Hybrid 2D/3D |
| Brand | Analysis |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Y.MU2000-D |
| Detector Type | Flat-Panel Detector |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | Up to 2.5 lp/mm |
| Density Resolution | 0.2–0.5% |
| X-ray Energy | 225 kV |
| Maximum Penetration | 350 mm (steel equivalent) |
| Inspection Envelope | 800 mm × 1100 mm (diameter × height) |
| Dimensional Measurement Accuracy | ±0.011 mm |
| Density Measurement Accuracy | ±0.2% |
| Maximum Sample Weight | 100 kg |
| System Dimensions | 3700 mm × 2300 mm × 2800 mm (L × W × H) |
| Brand | AnalysisTech |
|---|---|
| Origin | USA |
| Model | Phase12B |
| Heating Current Capacity | 100 A (max) |
| Max Heating Voltage | 20 V |
| Thermocouple Accuracy | ±0.15°C (typ.), ±0.3°C (max.) |
| Tj Measurement Resolution | ±0.007°C (typ.) |
| Tj Absolute Accuracy | ±0.2–±0.5°C (typ.) |
| Sampling Rate | 1 MHz |
| Dimensions | 17" × 17" × 7.5" H, 25 lb |
| PC Requirements | Windows 7/10 Pro (64-bit), 3 GHz CPU, 2 GB RAM, 500 GB HDD, 4+ USB ports |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EK-300iD / GF-300D |
| Instrument Type | Buoyancy-Based Density Balance |
| Measurement Principle | Archimedes’ Principle |
| Weighing Capacity | 300 g (EK-300iD), 310 g (GF-300D) |
| Weighing Readability | 0.01 g (EK-300iD), 0.001 g (GF-300D) |
| Density Resolution | 0.001 g/cm³ |
| Display | Backlit LCD (16 mm character height, EK-iD series) |
| Stabilization Time | ≤1 s (GF-D series) |
| Internal Resolution | 1/10,000,000 |
| Environmental Response Modes | FAST / MID / SLOW |
| Calibration | Full-digital span calibration with user-adjustable reference weight input |
| Temperature Compensation | Direct water temperature or reference liquid density entry |
| Density Comparison Mode | Hi / OK / Lo alarm output (optional external relay module) |
| Auto Power-Off | Configurable after ≥10 min inactivity |
| Interface | RS-232C standard port |
| Software | WinCT v3.x (Windows-compatible, supports Excel/Office data export, statistical analysis, time-series logging, and chart-based visualization) |
| Compliance | Built-in GLP/GMP/ISO audit trail functions (date/time stamping, instrument ID, calibration history, operator ID, measurement statistics) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SV-10 / SV-100 |
| Instrument Type | Oscillating Viscometer |
| Viscosity Range | 0.3–10,000 mPa·s (SV-10), 1,000–10,000 mPa·s (SV-100) |
| Repeatability | ±1% of reading (full scale, S.D., 20–30 °C, no condensation) |
| Sample Volume | ≥35 mL |
| Operating Frequency | 30 Hz sinusoidal fork oscillation |
| Display Units | mPa·s, Pa·s, cP, P (user-selectable) |
| Interface | RS-232C |
| Sensor Material | Stainless steel |
| Temperature Equilibration Time | <5 s |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SV-A |
| Quotation | Upon Request |
| Instrument Type | Oscillating Viscometer |
| Viscosity Range | 0.3–100,000 mPa·s |
| Brand | Ankersmid |
|---|---|
| Origin | USA |
| Model | PSA-300LC and PSA-1000 |
| Gas Inlets | 2 (customizable) |
| Heating Temperature Range | 0–350 °C |
| Isothermal Stability | ±0.1 °C |
| Pressure Range | 0–1000 psi (68.9 bar) |
| Test Function | Simulated PSA/TSA/VSA Cycles, Breakthrough Curve Analysis, Multicomponent Gas Adsorption |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 6010T |
| Temperature Range | 26–60 °C (standard), 15–70 °C (extended) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control Range | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive UV absorption |
| Ozone Measurement Range | 0–100 / 1,000 / 10,000 pphm |
| Detection Limit | 1 pphm |
| Response Time | 5 s |
| Accuracy | ±0.2 % of reading (ozone sensor) |
| Airflow Velocity in Chamber | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Recovery Time to 95 % Set Ozone Level | ≤10 min |
| Recovery Rate | 0.4 K/min |
| Temperature Compensation | Automatic, 0–60 °C ±1 °C |
| Pressure Compensation | Automatic, 600–1500 mbar ±2 mbar |
| Zero Drift | Auto-zeroing cycle every 2 s |
| Span Drift | None (single-beam optical design) |
| Power Supply | 230 V / 50 Hz |
| External Dimensions | 950 × 870 × 610 mm |
| Usable Internal Volume | 680 × 650 × 400 mm |
| Generator/Controller/Detector Cabinet | 1600 × 550 × 600 mm |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 6050-T |
| Temperature Range | 15–70 °C (RT = 23 °C) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control Range | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive UV absorption |
| Ozone Detection Limit | 1 pphm |
| Response Time | 5 s |
| Temperature Accuracy | ±5 K |
| Humidity Accuracy | −1 to +4 % RH |
| Airflow Velocity in Test Chamber | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Chamber Internal Dimensions | 425 × 460 × 270 mm |
| External Dimensions | 670 × 620 × 510 mm |
| Power Supply | 230 V / 50 Hz |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 6300 |
| Ozone Measurement Principle | Non-dispersive UV absorption |
| Ozone Range | 0–100 / 1,000 / 10,000 pphm |
| Response Time | 5 s |
| Detection Limit | 1 pphm |
| Accuracy | ±0.2% of reading |
| Repeatability | ±0.2% of full scale |
| Temperature Control Range | 15–70 °C (RT = 23 °C) |
| Temp. Accuracy | ±5 K |
| Temp. Ramp Rate | 0.4 K/min |
| Humidity Range | 30–80% RH |
| Humidity Accuracy | –1 to +4% RH |
| Humidity Stabilization Time to 95% | ≤20 min |
| Ozone Control Range | 20–200 pphm |
| Ozone Control Accuracy | ±1 pphm |
| Ozone Stabilization Time to 95% | 10 min |
| Airflow Velocity in Chamber | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Chamber Internal Dimensions | 680 × 650 × 400 mm |
| External Dimensions | 950 × 870 × 610 mm |
| Power Supply | 230 V / 50 Hz |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM 7500 |
| Temperature Range | 26–60 °C (RT = 23 °C) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control Range | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive ultraviolet (NDUV) absorption |
| Ozone Detection Limit | 1 pphm |
| Response Time | 5 s |
| Temperature Accuracy | ±5 K |
| Humidity Accuracy | −1 to +4 % RH |
| Airflow Velocity | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Chamber Internal Dimensions | 425 × 460 × 270 mm (standard) |
| Power Supply | 230 V / 50 Hz |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SIM 7500 |
| Pricing | Upon Request |
| Brand | ANSEROS |
|---|---|
| Origin | Germany |
| Model | SIM 8000 |
| Chamber Volume | 8000 L |
| Temperature Range | 15–70 °C (RT = 23 °C) |
| Humidity Range | 30–80 % RH |
| Ozone Concentration Control | 20–200 pphm |
| Ozone Measurement Principle | Non-dispersive UV Absorption |
| Ozone Detection Limit | 1 pphm |
| Response Time | 5 s |
| Accuracy | ±1 pphm (ozone), ±5 K (temperature), −1 to +4 % RH (humidity) |
| Airflow Velocity in Test Zone | 600 mm/s |
| Air Exchange Rate | 400 L/h |
| Power Supply | 230 V / 50 Hz |
| Brand | ANSEROS |
|---|---|
| Origin | Germany |
| Model | SIM-6300 |
| Internal Dimensions | 680 × 680 × 500 mm |
| External Dimensions | 1610 × 1500 × 1000 mm |
| Gas Flow Velocity | 8–700 mm/s |
| Air Exchange Rate | 50–500 L/min |
| Air Replacement Rate | 1–2000 dm³/h (33 L/min) |
| Temperature Range | RT to 70 °C ±0.5 °C |
| Humidity Range | 30–90 %RH (±1/+4 %RH) |
| Ozone Measurement Principle | Single-beam NDUV Photometry |
| Ozone Concentration Range | 0–1999 mg O₃/Nm³ or 0–1000 ppmv |
| Sensitivity | 0.001 ppmv |
| Accuracy | <1 % SCE |
| Linearity | 98 % SCE |
| Ozone Generation Method | Corona Discharge (COM-ADM) |
| Ozone Output Capacity | 10–2000 mg/h |
| Ozone Flow Rate | 100–2000 NL/h |
| Power Consumption | 3000 W |
| Voltage | 230 V, 10 A |
| Weight | 250 kg |
| Compliant Standards | ASTM D1149, ASTM D2802, ASTM D4246-02, ASTM D4575, ASTM D470, ASTM D518, BS 903 A43, DIN 53509-2-1, FORD FLTM BP101-01, GB/T 11206-2009, GB/T 13642-1992, GB/T 2951.1–2951.10-1997, GB/T 2951.21-2008, GB/T 7762-2003, HG/T 2716-2008, HG/T 2869-1997, ISO 1431-1 & -3, MIL-STD-1344A, NGF 37112, SAE J1401, SIS 16 12 10 |
| Brand | Anseros |
|---|---|
| Origin | Germany |
| Model | SIM6200-T-CL |
| Chamber Volume | 230 L |
| Internal Dimensions (H×W×L) | 50 × 68 × 68 cm |
| Total Dimensions (H×W×L) | 181 (+43) × 99 × 120 (+10) cm |
| Weight | 400 kg |
| Power Supply | 230/120 VAC, 50/60 Hz |
| Ozone Concentration Range | 0–1000 pphmv |
| Airflow Velocity (in chamber) | 8–16 mm/s (longitudinal, laminar flow) |
| Reynolds Number (Re) | 300–1000 |
| Loading Factor | G = 12 s/m (per ISO 1431-1) |
| Certified Ozone Analyzer | MP60602 |
| Ozone Generator | Maintenance-Free Type |
| Control System | Siemens SIMATIC S7-300 PLC with 15″ Touchscreen HMI |
| Data Interface | RS232, USB |
| Safety Features | Catalytic ozone destruct, activated carbon filter, turbofan recirculation, interlocked safety door, audible/visual alarms |
| Compliance | ASTM D1149, ISO 1431-1, DIN ISO 1431-1 |
| Brand | ANSEROS |
|---|---|
| Origin | Germany |
| Model | SIM6300-T-CL |
| Compliance | ASTM D1149, ISO 1431-1, DIN ISO 1431-1 |
| Ozone Generation | Maintenance-free corona discharge generator |
| Ozone Monitoring | Certified ozone analyzer (MP series) with closed-loop feedback control |
| Control System | Programmable logic controller (PLC) with interrupt-resume functionality for long-term durability testing |
| Air Circulation | Recirculating turbojet system integrated with catalytic ozone destruct unit and activated carbon filter |
| Sample Mounting | Dual-mode fixture—static test racks and dynamic rotating sample disc (4-position V-groove clamping) |
| Data Interface | RS232 serial port for real-time logging to ANSEROS on-board monitoring software |
| Chamber Configuration | Climate-controlled enclosure with temperature stabilization (ambient to +70 °C, ±0.5 °C uniformity) |
| Brand | Ansys |
|---|---|
| Origin | USA |
| Manufacturer | Ansys, Inc. |
| Product Type | Imported |
| Model | Custom |
| Instrument Type | Digital Ultrasonic Flaw Detector |
| Inspection Method | Pulse-Echo & Through-Transmission |
| Waveform Type | Pulsed Ultrasonic |
| Scan Envelope | 1800 mm × 1800 mm × 1200 mm |
| Transducer Configuration | Single-Crystal Probes (Pulse-Echo and Through-Transmission Modes) |
| Compliance | GE Aviation Approved Design |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Models | VBC-1, VBC-2, VBC-3, VBC-4, VBC-1T, VBC-2T, VBC-3T, VBC-4T |
| Temperature Range | −50 °C to 0 °C (VBC-2/3/4/T variants) or −60 °F to 30 °F (VBC-1/VBC-1T) |
| Specific Gravity Range | 1.15–1.30 sg (standard) |
| Resolution | 0.01 sg or 0.01 kg/L |
| Temperature Resolution | 5 °C or 10 °C (model-dependent) |
| Dimensions | 27 × 40 × 160 mm |
| Weight | 176 g (standard), 215 g (T-series with enhanced thermal stability) |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Autosorb 6100 |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Measurement Principle | Static Volumetric Method |
| Number of Analysis Stations | 3 |
| Specific Surface Area Range | 0.01 m²/g to unlimited |
| Pressure Range | 2×10⁻⁵ to 1100 Torr (2.6×10⁻⁸ to 0.997 p/p₀ for N₂ at 77 K) |
| Theoretical Basis | Vacuum Volumetric Method |
| Reproducibility | <1% RSD (per BAM Reference Material P115) |
| Ambient Operating Temperature | 15–35 °C |
| Temperature Control Accuracy | ±0.05 °C |
| Vacuum System | Dual-stage — Diaphragm Pump + Turbo-Molecular Pump |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Autosorb 6200 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Volumetric Vacuum Method (Physical & Chemical Adsorption), Dynamic Flow Method (Optional for Chemisorption) |
| Gas Inlet Ports | 6 |
| Maximum Heating Temperature | 1100 °C |
| Isothermal Stability | ±1 °C |
| Heating Ramp Rate | 1–50 °C/min |
| Pressure Range | 2×10⁻⁵ to 1100 Torr (2.6×10⁻⁸ to 0.997 p/p₀ for N₂ at 77 K) |
| Analytical Capabilities | Temperature-Programmed Reduction (TPR), Temperature-Programmed Oxidation (TPO), Temperature-Programmed Desorption (TPD), Pulse Titration |
| Detection Options | Integrated TCD, Optional Mass Spectrometer (MS), Optional Vapor Generator |
| Sample Stations | 1–3 Independent Physical Adsorption Stations + 1 Dedicated Chemisorption Station + 1 Dedicated p₀ Station |
| TruZone Active Liquid-Level Control | Yes |
| PowderProtect Anti-Dust System | Yes |
| Dewar Duration | >90 h (LN₂) |
| Integrated Degassing Stations | 6 (2 independently heated to 450 °C) |
| Cryosync Compatibility | Optional |
| Vapor Source | Optional |
| Cold Trap | Integrated |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Chemisorption Analyzer |
| Model | Autosorb 6300 |
| Gas Inlet Ports | 6 |
| Maximum Heating Temperature | 1100 °C |
| Isothermal Stability | ±1 °C |
| Ramp Rate | 1–50 °C/min |
| Pressure Range | 2×10⁻⁵ to 1100 Torr (2.6×10⁻⁸ to 0.997 p/p₀ for N₂ at 77 K) |
| Analytical Modes | TPR, TPO, TPD, Pulse Titration |
| Detection | Integrated TCD, Optional Mass Spectrometer |
| Vapor Source | Built-in |
| Dewar Duration | >90 h (LN₂) |
| Degassing Stations | 6 PID-controlled, up to 450 °C |
| TruZone Active Liquid-Level Control | Yes |
| PowderProtect Anti-Dust System | Yes |
| Stainless Steel Manifold with Pneumatic Valves | Yes |
| Vacuum Integrity Improvement | 38% vs. legacy designs |
| BET Surface Area Detection Limit | 0.01 m²/g (N₂, 77 K) |
| Pore Size Range | 0.35 nm – 500 nm |
| Metal Dispersion Detection Limit | 0.003 m² (H₂ on Pt, 313 K) |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | ElaTest |
| Density Measurement Range | 0.8–2.6 g/cm³ |
| Temperature Range | 0–40.0 °C |
| Repeatability | ±0.00001 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 40–120 cm³ |
| Application | Density of uncured rubber and rubber compounds |
| Instrument Type | Benchtop Laboratory Densitometer |
| Detection Principle | Pneumatic (gas displacement) density measurement |
| Compliance | Designed for GLP/GMP environments with audit-ready data handling |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MetaStation |
| Instrument Type | Torque Rheometer |
| Sample Type | High-Viscosity Materials |
| Sample State | Molten or Paste-Like |
| Bearing Type | Mechanical Bearings |
| Frequency Range | 10⁻³–628 rad/s |
| Minimum Rotational Speed | 0.2 min⁻¹ |
| Maximum Torque | 500 N·m |
| Maximum Rotational Speed | 3000 rpm |
| Torque Resolution | <100 nN·m |
| Brand | Anton Paar |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Calotest Series |
| Instrument Type | Ball Cratering Tribological Coating Thickness Tester |
| Maximum Operating Temperature | Ambient (23 °C ± 2 °C) |
| Rotational Speed Range | 10–3000 rpm |
| Wear Time Range | 1–10000 s |
| Standard Ball Diameters | 10, 15, 20, 25.4, 30 mm |
| Measurable Coating Thickness Range | 0.1–50 µm |
| Applicable Standards | ISO 1071-2, VDI 3198 |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ChemBET Pulsar |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Fully Automated Flow Method |
| Gas Inlet Ports | 5 (expandable to 6 with optional gas mixer) |
| Temperature Range | Ambient to 1100 °C |
| Heating Rate | 1–50 °C/min (programmable in multiple segments) |
| Analytical Functions | TPR, TPD, TPO, Pulse Titration |
| Sample Stations | 2 (1 analysis + 1 preparation) |
| Quantitative Loop Volumes | 50, 100, 250 µL (custom volumes available) |
| Detector | High-Stability TCD with oxidation- and NH₃-resistant filament |
| Sample Tube Options | U-shaped quartz, Pyrex®, or borosilicate |
| Steam Trap | Integrated between sample tube and detector |
| GC/MS Interface Ports | 3 configurable locations (post-sample, post-trap/pre-detector, post-detector) |
| Surface Area Range | 0.01–280 m²/g |
| Total Pore Volume | 1×10⁻⁴–1.5×10⁻¹ cm³ |
| Volume Accuracy | ±1% |
| Repeatability | ±0.5% |
| Compatible Gases | H₂, O₂, CO, NO, SO₂, NH₃ (chemisorption) |
| Cooling Time (1100 °C → 100 °C) | < 30 min |
| Dimensions (W×H×D) | 45 × 63 × 42 cm |
| Weight | 24 kg |
| Operating Environment | 15–35 °C, 20–80% RH (non-condensing) |
| Power Supply | 100/120 V or 220/240 V AC, 50/60 Hz |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DMA 1002 |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Repeatability | ±0.00005 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Temperature Range | 15–60 °C |
| Temperature Stability | ±0.02 °C |
| Minimum Sample Volume | 1 mL |
| Display | 7″ TFT WVGA Touchscreen (800 × 480 px, PCAP) |