| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Model | SENSIVATE |
| Temperature Range | 10–150 °C (heating), 0–80 °C (cooling) |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Reaction Volume Accuracy | ±5% |
| Temperature Reproducibility | ±0.5 °C |
| Temperature Accuracy | ±1 °C |
| Safety Cut-off Temperature | 160 °C (heating), 90 °C (cooling) |
| Thermal Stabilization Time | ≤30 min (to 150 °C or to 5 °C) |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | PD3100 |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Temperature Control Range | Ambient to 120 °C (±0.1 °C stability) |
| Reagent Flow Rate | 0.01–2.0 mL/min (dual-channel, independently adjustable) |
| Reaction Coil | Stainless steel or PEEK-lined, 0.25–0.5 mm ID, 1–5 m length (configurable) |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | PD3110 |
| Price Range | USD 2,800 – 7,000 |
| Brand | HMC |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PHRED |
| Price Range | USD 1,400–2,800 (FOB) |
| Operating Temperature | Ambient |
| Derivatization Flow Rate | 0.3 mL/min |
| Reaction Capillary ID | 0.25 mm |
| Dimensions (L×W×H) | 330 × 50 × 70 mm |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 8 W |
| Capillary Material | PTFE |
| Maximum Pressure Rating | 500 psi (35 bar) |
| Weight | ~4 kg |
| Regulatory Compliance | AOAC 2005.08, AOAC 2008.02, AOAC Aa 11-05, Taiwan Food Agency Notice No. 0981800370, Ph. Eur. 2.8.18, GB/T 18979–2003, SN/T 1109–2002 |
| Brand | Huapaikeyi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HS10A |
| Temperature Range | +5–150 °C |
| Derivatization Reagent Flow Rate | 0–5 mL/min |
| Reaction Capillary | Stainless Steel, 10 m × 0.2 mm ID |
| Brand | LABA (Tianjin) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PCR2 |
| Temperature Range | Ambient to 150 °C |
| Derivatization Reagent Flow Rate | 0.01–5.00 mL/min |
| Reaction Coil Material | PEEK |
| Brand | LABA (Tianjin LABA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | PCR 3 |
| Temperature Range | Ambient to 200 °C |
| Derivatization Reagent Flow Rate | 0.001–10.000 mL/min |
| Reaction Coil Material | Stainless Steel |
| Brand | LABA |
|---|---|
| Origin | USA |
| Model | PCR3 |
| Temperature Range | Ambient to 200 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Compliance | Fully compatible with all HPLC platforms (Agilent, Waters, Shimadzu, Thermo Fisher, etc.) |
| Control Interface | Dual-mode (front-panel keypad + PC via USB/RS-232) |
| Safety Features | Overpressure shutdown, leak detection, thermal overheat protection |
| Fluidic Architecture | Chemically inert, self-cleaning pump head, pressurized reagent reservoirs with N₂ blanket control |
| Reactor Options | Interchangeable, customizable volume reaction coils (standard: 0.5–5 mL internal volume) |
| Brand | Laba (Tianjin Laba Co., Ltd.) |
|---|---|
| Origin | USA |
| Model | PCR3 |
| Temperature Range | Ambient to 200 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Pump Type | High-Precision Syringe-Type Piston Pump |
| Control Interface | Front-panel Keypad + PC via USB/RS-232 |
| Safety Features | Overpressure Shutdown, Leak Detection, Thermal Overload Protection |
| Reagent Delivery | Pressurized N₂-driven with Adjustable Flow Regulation and Splitting |
| Reactor Options | Modular, Customizable Volume (Standard: 0.5–5 mL), Multi-directional Mixing Geometry |
| Fluidic Path | Fully Chemically Inert (PEEK, Sapphire, Hastelloy C-276) |
| Cleaning | Integrated On-Line Solvent Flush Routine |
| Compliance | Designed for GLP/GMP environments |
| Brand | LABA (Tianjin LABA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PR-2 |
| Temperature Range | Ambient to 200 °C |
| Derivatization Reagent Flow Rate | 0.001–10.000 mL/min |
| Reaction Coil Material | PEEK |
| Brand | Laballiance |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Laballiance PCDS |
| Price | Upon Request |
| Pump Flow Rate | 0.01–2.5 mL/min |
| Maximum Pressure | 2500 psi |
| Flow Precision | ±0.5% RSD |
| Flow Accuracy | ±2% |
| Flow Path Material | Full PEEK |
| Temperature Control Range | Ambient +10 °C to 150 °C |
| Temperature Accuracy | ±2 °C |
| Temperature Repeatability | ±1 °C |
| Safety Cutoff Temperature | 160 °C |
| Reactor Volume Accuracy | ±5% |
| Warm-up Time to 150 °C | ≤30 min |
| Communication Interface | RS232 |
| Brand | LABORAT |
|---|---|
| Model | LYM-1061 |
| Derivatization Volume Options | 0.50 / 0.75 / 1.00 / 1.50 mL |
| Reaction Loop Material | Polyetheretherketone (PEEK), Polytetrafluoroethylene (PTFE), 316L Stainless Steel |
| Operating Temperature Range | Ambient + 5.0 °C to 150.0 °C |
| Flow Rate Control Range | 0.001–4.999 mL/min |
| Pump Fluid Path | Full-PEEK chemically inert construction |
| Reaction Coil Layout | 1.2 cm annular configuration |
| Real-time Instrument Status Monitoring | Yes |
| Optional Piston Wash | 1 mL/min |
| Brand | Laborator |
|---|---|
| Model | LYR-1090 |
| Light Source Wavelength | 253.7 nm |
| Derivatization Cell Volume | 1 mL |
| UV Lamp Lifetime | 7,000 h |
| Temperature Monitoring | Yes |
| UV Intensity Monitoring | Yes |
| Compliance | Designed for USP <621>, ISO/IEC 17025, and GLP-aligned workflows |
| Software Audit Trail | Not included (available in LYR-2094 variant) |
| Origin | China |
| Brand | LCTech |
|---|---|
| Origin | Germany |
| Model | UVE |
| Temperature Range | Ambient |
| Derivatization Flow Rate | 1.2 mL/min |
| Reaction Coil Volume | 1 mL |
| Regulatory Certifications | CE, DIN ISO 9001 |
| Method Recognition | AOAC Official Method |
| Brand | Otisens |
|---|---|
| Origin | Tianjin, China |
| Model | PCX-500 |
| Temperature Range | +5 °C above ambient to 150 °C |
| Derivatization Reagent Flow Rate | 5 µL/min to 2500 µL/min (or 5 µL/min to 10 mL/min) |
| Reaction Coil | Stainless Steel, 10 mm × 0.2 mm ID |
| Brand | Pickering Laboratories |
|---|---|
| Origin | USA |
| Model | PINNACLE PCX DELTA |
| Temperature Range | Ambient to 150 °C (programmable, ±1 °C stability) |
| Derivatization Reagent Flow Rate | 0.01–2.0 mL/min (precision ±0.5% RSD) |
| Reaction Coil Options | PEEK, FEP, or stainless steel (0.25–1.0 mm ID, 1–30 m length) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | Pickering |
|---|---|
| Origin | USA |
| Model | Onyx PCX |
| Temperature Range | 5 °C to 130 °C (ambient +5 °C) |
| Derivatization Reagent Flow Rate | 50 µL/min – 1500 µL/min |
| Reaction Coil Volume | 0.1–3 mL |
| Brand | Pickering |
|---|---|
| Origin | USA |
| Model | Vector PCX |
| Temperature Range | 5 °C – 130 °C |
| Derivatization Reagent Flow Rate | 0.05 – 2.0 mL/min |
| Reaction Coil Volume | 0.1 – 3.0 mL |
| Construction | PEEK Fluidic Path |
| Flow Control | Electronic, Pulse-Free |
| Safety | Integrated Leak Detection, Over-Temperature & Over-Pressure Protection |
| Compliance | Designed for GLP/GMP environments |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Model | KRC-200 |
| Derivatization Light Source | Dual-wavelength UV (254 nm / 352 nm) |
| Flow Rate Range | 0.6–2.0 mL/min |
| Optimal Flow Rate | 1.2 mL/min |
| Reaction Cell Volume | 1 mL |
| Maximum Pressure Rating | 10 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±2 nm |
| Bandwidth | 2 nm |
| Light Source Lifetime | ≥8000 h |
| Dimensions (H×W×D) | 88 mm × 90 mm × 420 mm |
| Operating Temperature | 0–45 °C |
| Relative Humidity | 20–85 % RH |
| Power Supply | 220 V ±10 %, 50 Hz ±2 % |
| Compliance | AOAC 2005.08, AOCS Aa11-05, Ph. Eur. 2.8.18, Chinese National Standards & ChP Methods |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MDS-2000 |
| Temperature Range | Ambient to 150 °C |
| Derivatization Reagent Flow Rate | 0.01–4.99 mL/min |
| Reaction Cell Volume | 1 mL |
| Flow Accuracy | ±0.5% |
| Flow Precision | 0.025% RSD |
| Pressure Range | 0–20 MPa |
| Power Supply | 220 V, 10 A |
| Dimensions (H×W×D) | 420 mm × 262 mm × 530 mm |
| Weight | 25 kg |
| Temperature Stability | ±0.02 °C |
| Temperature Setpoint Accuracy | ±0.1 °C |
| Temperature Equilibration Time | <20 min |
| Heating Power | 100 W |
| Standard Reaction Cell Volumes | 0.5 mL and 1 mL (optional range: 0.1–2 mL) |
| Fluidic Path Material | PEEK and optional stainless steel (SUS316) |
| Integrated Pulse Dampener | Yes |
| Backflow Prevention | Integrated check valve |
| Over-Temperature Protection | Active cutoff at 150 °C |
| Optional Online Degasser | Yes |
| Optional Pressurized Reagent Reservoir with SARAN™ tubing | Yes |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MDS-3000-D |
| Temperature Range | Ambient + 5 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.01–9.999 mL/min |
| Reaction Coil Volume | 1 mL |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Model | MDS-3100 |
| Temperature Range | Ambient +5 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.01–9.999 mL/min |
| Reaction Coil Volume | 1 mL |
| Material Construction | PEEK fluidic path |
| Flow Accuracy | ≤0.5% |
| Flow RSD | ≤0.1% |
| Safety Features | Backflow prevention valve, overpressure protection (500 psi), overtemperature cutoff (150 °C), leak detection shutdown, inert gas pressurized reagent reservoir (optional) |
| Compliance | Designed for GLP/GMP-compliant HPLC workflows |
| Brand | Pribolab |
|---|---|
| Model | MDU-200 |
| Origin | Shandong, China |
| Derivatization Fluid Flow Rate | 1–2 mL/min |
| Reaction Coil Volume | 1 mL |
| Operating Temperature | Ambient |
| Compliance | AOAC Official Method 2005.08, AOCS Aa11-05, Ph. Eur. 2.8.18, Chinese Pharmacopoeia (2020 Ed.) & GB Standards |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | Shimadzu PR-1000 |
| Temperature Range | Ambient |
| Reaction Tubing Material | FEP (Fluorinated Ethylene Propylene) |
| UV Source Lifetime | 9,000 hours |
| Derivatization Flow Path | Passive (No Pump-Driven Reagent Delivery) |
| UV Leakage Protection | Integrated Shielding with UV-Blocking View Window |
| Delay Volume | Optimized for Minimal Extra-Column Dispersion |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | PD-1000 |
| Temperature Range | Ambient |
| Derivatization Reagent Flow Rate | 3 mL/min |
| Reaction Tubing Material | Inert (e.g., PFA or FEP) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | PCD-3000 |
| Temperature Range | Ambient to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–9.999 mL/min |
| Reaction Coil Material | Chemically Inert (e.g., PEEK, Hastelloy, or fused silica) |
| Brand | Wufeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LC-100 PC Reactor |
| Temperature Range | Ambient + 5.0 °C to 150.0 °C |
| Derivatization Reagent Flow Rate | 0.001–4.999 mL/min |
| Reaction Coils | High-inertness PEEK, available volumes: 0.50 mL, 0.75 mL, 1.00 mL, 1.50 mL |
| Brand | Wufeng |
|---|---|
| Origin | Shanghai, China |
| Model | LC-100 UV Reactor |
| Reaction Tubing | High-Pressure PTFE Capillary |
| Compliance | Chinese Pharmacopoeia 2020, AOAC 2005.08 / 2008.02 / Aa 11-05, Taiwan FDA Notice No. 0981800370, European Pharmacopoeia 2.8.18 |
| UV Lamp | Long-Life Imported OEM UV Lamp (254 nm), Digitally Displayed Irradiance Intensity |
| Housing Material | Chemically Inert, High-Transparency Polymer Coil Support Frame |
| Regulatory Context | Designed for GLP-compliant laboratories |