Empowering Scientific Discovery

ChemTron Model 63927 / 63801 / 63893 Digital Temperature Indicator for Refrigerated Laboratory Equipment

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand ChemTron
Origin Germany
Model Numbers 63927, 63801, 63893
Channel Count Single-Channel
Measurement Range −50 to +70 °C
Resolution 0.1 °C
Accuracy ±0.5 °C
Calibration Points −20 °C, 0 °C, +4 °C, +37 °C, +21 °C
Sensor Fill Fluid Ethylene Glycol Mixture
Application Class Refrigerated & Controlled Environment Monitoring
Compliance Context Designed for GLP/GMP-aligned temperature validation workflows in clinical and research labs

Overview

The ChemTron Model 63927 / 63801 / 63893 Digital Temperature Indicator is a purpose-engineered, single-channel electronic thermometer designed for continuous, traceable temperature monitoring of critical cold-chain and environmental containment systems in regulated laboratory environments. Built in Germany and distributed under the ChemTron brand, this instrument employs a platinum resistance temperature detector (Pt100 or Pt1000 sensor element, depending on model configuration) immersed in a thermally stable ethylene glycol mixture within a sealed stainless-steel probe sheath. The sensing principle relies on the predictable, linear resistance–temperature relationship of platinum, enabling high reproducibility across its full operating range of −50 °C to +70 °C. It is specifically optimized for installation in blood bank refrigerators, ultra-low temperature (−80 °C) freezers (via external probe routing), incubators, drying ovens, water baths, and controlled-room-temperature storage cabinets—where regulatory adherence to temperature stability, data integrity, and audit readiness are mandatory.

Key Features

  • High-resolution digital display with 0.1 °C readout granularity and verified accuracy of ±0.5 °C across five NIST-traceable calibration points (−20 °C, 0 °C, +4 °C, +21 °C, +37 °C)
  • Robust stainless-steel probe housing filled with ethylene glycol mixture for rapid thermal response and minimized thermal lag in low-temperature applications
  • Single-channel architecture ensures signal integrity and simplifies integration into existing validation protocols without cross-channel interference
  • CE-marked electronics compliant with EN 61326-1 (EMC for laboratory equipment) and EN 61010-1 (safety requirements for electrical equipment)
  • Mounting-ready design with standardized 1/2″ NPT or M12 threaded probe interface for secure installation in refrigerator doors, incubator walls, or bath wells
  • No internal battery dependency—powered via standard 100–240 V AC input with optional 24 V DC variant available for UPS-backed installations

Sample Compatibility & Compliance

This temperature indicator is validated for use with a wide spectrum of enclosed laboratory climate systems, including but not limited to: blood storage refrigerators (maintained at +2 °C to +6 °C per AABB standards), cryogenic freezers (−20 °C, −30 °C, −80 °C), CO2 and hypoxic incubators (+35 °C to +37 °C), humidity-controlled drying chambers, and calibrated water baths. Its ethylene glycol-filled probe ensures mechanical stability and freeze-thaw resilience down to −50 °C—critical for monitoring intermediate cold storage where ethanol-based fluids may crystallize. While the unit itself does not provide data logging, its analog output (0–10 V or 4–20 mA, configurable per model) enables seamless integration with third-party SCADA systems, BMS platforms, or validated electronic loggers compliant with FDA 21 CFR Part 11 and EU Annex 11 requirements. Documentation packages include factory calibration certificates with uncertainty budgets referenced to ISO/IEC 17025-accredited laboratories.

Software & Data Management

The ChemTron 63927/63801/63893 operates as a standalone measurement node and does not include embedded firmware-based data storage or onboard software. Instead, it delivers real-time analog output signals compatible with industry-standard data acquisition hardware (e.g., Omega OM-DAQ, National Instruments CompactDAQ, or Siemens Desigo CC). When integrated into a validated monitoring system, the device supports full audit trail generation, user access control, alarm event logging, and electronic signature functionality—provided the host platform meets ALCOA+ (Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available) data governance criteria. Optional RS-485 Modbus RTU communication modules are available for centralized polling in multi-device deployments, facilitating automated calibration scheduling and deviation reporting aligned with ISO 17025 and CAP/CLIA quality management frameworks.

Applications

  • Continuous verification of temperature setpoints in blood bank refrigerators per AABB Standard 18 and CAP Checklist MICRO.42350
  • Baseline stability assessment during IQ/OQ/PQ qualification of new or relocated ultra-low temperature freezers
  • Real-time monitoring of incubator chamber uniformity during cell culture process validation
  • Thermal mapping support for stability chambers used in pharmaceutical stability testing (ICH Q1A–Q1E)
  • Reference-grade temperature verification during routine calibration of secondary thermometers in GLP-compliant labs
  • Environmental monitoring in cleanrooms and biosafety cabinets requiring documented temperature compliance per ISO 14644-3

FAQ

Is this device suitable for direct immersion in liquid media such as water baths?
Yes—the probe is rated for continuous immersion in aqueous and glycol-based solutions up to +70 °C; however, prolonged exposure above +50 °C may accelerate long-term drift and requires accelerated recalibration intervals.
Does the unit include a certificate of calibration?
Each unit ships with a manufacturer’s calibration certificate listing measured deviations at five defined temperature points, traceable to national standards via DAkkS-accredited subcontractors.
Can the display be mounted remotely from the probe?
Yes—models support cable lengths up to 10 meters between probe and display module without signal degradation, provided shielded twisted-pair cabling is used per IEC 61000-4-5 surge immunity guidelines.
What maintenance is required to sustain accuracy over time?
Annual recalibration is recommended; visual inspection of probe sheath integrity and verification of fill-fluid clarity should occur quarterly in high-cycle environments.
Is the ethylene glycol fill fluid biocompatible for use in pharmaceutical-grade cold rooms?
The USP-grade ethylene glycol mixture used poses no vapor-phase risk and is non-volatile under normal operating conditions—making it appropriate for GMP environments where organic solvent emissions must be controlled.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0