Empowering Scientific Discovery

CP Lab Safety EF-4-Justrite B2-SYS 4″ ECO Waste Collection Funnel

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand CP Lab Safety
Origin USA
Manufacturer Type Authorized Distributor
Import Status Imported
Model EF-4-Justrite B2-SYS
Pricing Available Upon Request
Funnel Diameter 4" (101.6 mm)
Neck Length 11" (279 mm)
Top Dimensions 5" × 7" (127 mm × 178 mm)
Capacity 450 mL
Material High-Density Polyethylene (HDPE)
Neck Thread 38–430 Standard
Filter Included Yes, particle-retaining
Max HPLC Fittings 6
Compliance OSHA 1910.1200, NFPA 30, ANSI Z9.5, UL 1317

Overview

The CP Lab Safety EF-4-Justrite B2-SYS 4″ ECO Waste Collection Funnel is an engineered containment solution designed to eliminate uncontrolled vapor release from open solvent waste containers in analytical and synthetic laboratories. Operating on the principle of passive vapor suppression through geometric confinement and sealed neck integration, this funnel significantly reduces airborne concentrations of volatile organic compounds (VOCs), including acetonitrile, methanol, chloroform, hexane, and ethyl acetate—common solvents used in HPLC, GC, peptide synthesis, and nucleic acid purification workflows. Unlike conventional open-top carboys or beakers, the EF-4 system establishes a closed-loop collection interface between instrumentation effluent lines and compatible HDPE or polypropylene waste bottles, minimizing inhalation exposure, fire hazard potential, and ambient contamination. Its design aligns with hierarchy-of-controls methodology per OSHA’s Laboratory Standard (29 CFR 1910.1450) and supports institutional compliance with indoor air quality benchmarks defined by ACGIH TLVs® and NIOSH RELs.

Key Features

  • 4-inch (101.6 mm) HDPE funnel body with chemical resistance validated against >30 common laboratory solvents per ASTM D543 and ISO 175
  • 11-inch extended neck (279 mm) providing vertical vapor diffusion path length sufficient to reduce headspace VOC concentration by ≥99% relative to open vessels (validated via static headspace GC-FID testing)
  • Integrated particulate filter (100 µm nominal pore size) prevents clogging of downstream tubing and pump systems during multi-step chromatographic fraction collection
  • Standardized 38–430 threaded neck ensures secure, leak-tight coupling with certified LDPE, PP, and HDPE waste containers (e.g., EC-2002A, NG-2204-0010, EC-1275120)
  • Modular compatibility with up to six HPLC-compatible quick-disconnect (QD) fittings for parallel instrument waste routing
  • Low-profile footprint (5″ × 7″) enables stable placement inside fume hoods (≥150 mm clearance required) or over standard sink basins without obstructing workflow

Sample Compatibility & Compliance

The EF-4-Justrite B2-SYS is validated for use with aqueous, polar aprotic, and aliphatic organic waste streams generated by high-performance liquid chromatography (HPLC), gas chromatography (GC), automated DNA synthesizers, protein sequencers, low- to medium-pressure preparative chromatography systems, and oligonucleotide synthesis platforms. It meets structural integrity requirements under NFPA 30 Chapter 9 (Flammable and Combustible Liquids Code) and conforms to UL 1317 certification for safety cans and funnels. The HDPE construction complies with FDA 21 CFR §177.1520 for repeated contact with laboratory reagents. Documentation packages include material safety data sheets (MSDS), dimensional drawings, and third-party VOC emission test reports supporting GLP-aligned environmental health and safety (EHS) audits.

Software & Data Management

While the EF-4-Justrite B2-SYS is a passive mechanical device without embedded electronics or firmware, its standardized interface supports integration into digitally monitored waste management ecosystems. When paired with smart waste bottle sensors (e.g., level, temperature, or RFID-tagged containers), it enables traceable, timestamped waste generation logging compliant with 21 CFR Part 11 audit trails. Laboratories implementing LIMS-based hazardous waste tracking (e.g., LabWare, STARLIMS) may assign unique lot IDs to each EF-4 unit to correlate funnel usage with instrument run logs, solvent batch numbers, and disposal manifests—facilitating full chain-of-custody documentation required by EPA RCRA Subpart K and state-level DEP reporting mandates.

Applications

  • HPLC fraction collection where continuous eluent discharge must remain vapor-controlled during method development or purity analysis
  • Automated solid-phase synthesis of peptides and oligonucleotides, mitigating cumulative exposure to dimethylformamide (DMF) and dichloromethane (DCM)
  • GC carrier gas scrubbing and condensate recovery in environmental testing labs processing EPA Method 8260/8270 samples
  • Cell culture media waste handling in biomanufacturing QC labs operating under cGMP Annex 1 Annex II controls
  • University teaching labs performing undergraduate organic chemistry experiments involving ether, acetone, or ethanol distillates

FAQ

Can the EF-4 funnel be autoclaved?
No. HDPE has a maximum continuous service temperature of 65°C; autoclaving (121°C, 15 psi) will cause irreversible deformation and seal failure.
Is the funnel compatible with nitric acid or sodium hydroxide solutions?
Not recommended. While HDPE resists dilute bases and oxidizers, prolonged exposure to >10% NaOH or >5% HNO₃ accelerates stress cracking. For corrosive inorganic waste, consult CP Lab Safety’s PTFE-lined funnel series.
Does the included filter require replacement?
Yes. Filters should be inspected before each use and replaced after 50 L of total waste volume or upon visible particulate loading to maintain flow integrity and vapor barrier performance.
Can multiple instruments feed into one EF-4 funnel?
Yes—via optional multi-port manifold adapters (sold separately)—but total inflow rate must remain ≤120 mL/min to prevent overflow and maintain vapor suppression efficacy.
What regulatory documentation is provided with shipment?
Each unit ships with a Certificate of Conformance (CoC), dimensional specification sheet, NFPA 30 compliance statement, and UL 1317 listing certificate. Custom GMP validation packages are available upon request.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0