- All
- Favorite
- Popular
- Most rated
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | DA-100 |
| Instrument Type | Oscillating U-Tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids Only |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Temperature Control Range | 15–40 °C (±0.1 °C stability, ±0.5 °C accuracy) |
| Repeatability | 0.001 g/cm³ |
| Resolution | 0.001 g/cm³ |
| Minimum Sample Volume | ~1 mL |
| Display | LCD |
| Measurement Time | 20–90 s |
| Calibration Standards | Dry air and double-distilled water |
| Data Interface | RS-232C |
| Power Supply | AC 100–240 V, 50/60 Hz, 30 W |
| Dimensions | 275 × 350 × 165 mm (W×D×H) |
| Weight | ~6 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Kyoto Electronics Manufacturing Co., Ltd. |
| Type | Imported Instrument |
| Model | PCD-500 |
| Instrument Category | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Principle | Streaming Potential Detection |
| Electrode Output Range | ±2 V DC |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | ~10 W |
| Dimensions (W×D×H) | 250 × 210 × 400 mm |
| Weight | ~4.5 kg |
| Sample Handling | Stirred beaker-based immersion configuration |
| Piston Actuation | Continuously variable vertical reciprocation |
| Minimum Detectable Charge Concentration | ≥1 × 10⁻⁵ mol/L (dilution required for high-concentration samples) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Model | DA-860 |
| Measurement Principle | U-Tube Oscillation Method |
| Standard Compliance | ASTM D4052-22, EN ISO 12185:1996, EN ISO 15212-1:1999, GB/T 2013-2010, GB/T 29617-2013, SH/T 0604-2000 |
| Density Range | 0–3 g/cm³ |
| Accuracy | ±0.000003 g/cm³ |
| Repeatability | ±0.000001 g/cm³ |
| Temperature Control | 0–100 °C (Peltier), Resolution: 0.001 °C |
| Sample Volume | ~1 mL (syringe) or ~2 mL (pump) |
| Measurement Time | ~10 s (to 4-digit stability) |
| Interface | LAN, USB, RS-232C |
| Power | AC 100–240 V, 50/60 Hz |
| Dimensions | 295 × 330 × 255 mm |
| Weight | ~19 kg |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop Density Meter & Refractometer |
| Temperature Control | Peltier-regulated (0–96°C for density, 5–75°C or optional 5–100°C for refractometry) |
| Display | Full-color touchscreen LCD |
| Sample Volume | ~1 mL per measurement |
| Measurement Principle | U-tube oscillation (density), Critical-angle light refraction at Na-D line (589.3 nm) |
| Density Range | 0–3 g/cm³ (model-dependent resolution: 1×10⁻⁶ g/cm³ for DA-650, 1×10⁻⁵ g/cm³ for DA-645, 1×10⁻⁴ g/cm³ for DA-640) |
| Refractive Index Range | nD = 1.32000–1.58000 (RA-620) or 1.3200–1.7000 (RA-600) |
| Refractive Index Accuracy | ±0.00002 nD (RA-620) / ±0.0001 nD (RA-600) |
| Brix Range | 0.00–100.00% (RA-620), 0.0–100.0% (RA-600) |
| Brix Accuracy | ±0.014% (RA-620), ±0.1% (RA-600) |
| Viscosity Compensation | Built-in dynamic correction algorithm for high-viscosity liquids |
| Auto-sampling | Integrated peristaltic pump with automated rinse, purge, and dry-cycle detection |
| Data Storage | 300 measurement records, 100 user-defined methods |
| Connectivity | LAN, USB, RS-232C |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Instrument Type | Laboratory Benchtop Densitometer |
| Measurement Principle | U-Tube Oscillation Method |
| Sample Type | Liquids Only |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±1×10⁻⁴ g/cm³ |
| Density Resolution & Repeatability | 0.0001 g/cm³ / SD ≤5×10⁻⁵ g/cm³ |
| Temperature Control Range | 0–96 °C (Peltier-regulated) |
| Temperature Accuracy | ±0.05 °C |
| Temperature Resolution | 0.01 °C |
| Minimum Sample Volume | 1–2 mL |
| Auto-Sampling | Integrated peristaltic pump with rinse/dry cycle |
| Compliance | ASTM D4052, ISO 12185, BS EN ISO 15212-1, GB/T 2013, GB 5009.2, JJG 1058, GLP-ready data audit trail |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-611 |
| Titration Mode | Fully Automated |
| Instrument Type | Volumetric or Coulometric Karl Fischer Moisture Analyzer Compatible |
| Measurement Resolution | 0.1 µg |
| Moisture Content Range | 1 ppm to 100% |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Volume | 0–16 mL |
| Titration Control Precision | ±0.3% |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HF-48 |
| Pricing | Upon Request |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-512S |
| Titration Mode | Fully Automatic |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg – 300 mg H₂O |
| Accuracy | ≤0.3% |
| Minimum Dispensing Volume | 0.1 µg |
| Titration Control Precision | ±0.3% |
| Power Supply | AC 100–240 V, 50/60 Hz, ~600 W |
| Heating Temperature Range | 50–1000 °C |
| Evaporation Tube Material | Quartz |
| Sample Boat Material | Quartz |
| Sample Capacity | 10 mL |
| Dimensions | 835(W) × 340(D) × 345(H) mm |
| Weight | 18 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CHD-502N |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop Laboratory System |
| Sample Phase | Liquid Only |
| Density Range | 0–3 g/cm³ |
| Density Resolution | 1 × 10⁻⁶ g/cm³ |
| Density Repeatability | ±1 × 10⁻⁶ g/cm³ |
| Temperature Control Range | 0–96 °C |
| Minimum Sample Volume | 1–2 mL |
| Sample Capacity | 30 vials (20 mL glass bottles) |
| Integrated Vacuum/Pressure Pump | Yes, rated for up to 50,000 mPa·s viscosity |
| Power Supply | AC 100–120 V / 200–240 V, 50/60 Hz, ~40 W |
| Dimensions (W×D×H) | 582 × 445 × 392 mm |
| Weight | 17 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DCU-551N |
| Instrument Type | Oscillating U-Tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Phase | Liquid Only |
| Density Range | 0–3 g/cm³ |
| Temperature Control Range | 0–96 °C |
| Repeatability | ±1 × 10⁻⁶ g/cm³ |
| Resolution | 0.000001 g/cm³ |
| Minimum Sample Volume | 1–2 mL |
| Viscosity Compatibility | Up to 50,000 mPa·s (via integrated vacuum-pressure pump) |
| Sample Vessel | 20 mL glass vial |
| Power Supply | AC 100–120 V / 200–240 V, 50/60 Hz, ~40 W |
| Dimensions (W×D×H) | 291 × 310 × 342 mm |
| Weight | 10 kg |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | D&S AERD |
| Pricing | Upon Request |
| Measurement Principle | Thermopile-based differential temperature method per ASTM C1371 |
| Wavelength Range | 3–30 µm |
| Emissivity Range | 0.01–1.00 |
| Repeatability | ±0.01 emittance units |
| Response Time | ~10 s |
| Display Accuracy | ±0.3% of reading |
| Operating Temperature | −10 to +40 °C |
| Dimensions (H×W×D) | 51 × 80 × 152 mm |
| Weight | ~370 g |
| Detector Output | ~2.5 mV |
| Power Supply | DC 9 V (host), AC 100–240 V (charger) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | DCU-600 |
| Instrument Type | Oscillating U-tube Density Meter Accessory |
| Form Factor | Benchtop Laboratory Unit |
| Sample Type | Liquids Only |
| Density Range | 0–3 g/cm³ |
| Temperature Control Range | 0–96 °C |
| Minimum Sample Volume | ~5 mL |
| Compatibility | Designed exclusively for KEM DA-640, DA-645, and DA-650 digital density meters |
| Automation Functions | Automated sample aspiration, measurement triggering, waste discharge, dual-solvent cleaning (Wash 1 & Wash 2), nitrogen-assisted drying, and cell integrity verification |
| Sample Vessel | 20–100 mL beaker or 100 mL disposable cup |
| Power Supply | DC 24 V, 5 A (AC adapter included) |
| Dimensions (W×D×H) | 214 × 295 × 304 mm |
| Weight | Approx. 5.5 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Model | MKV-710B |
| Measurement Resolution | 0.005 mL |
| Water Content Range | 1 ppm to 100% H₂O |
| Titration Accuracy (10 mL burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 |
| Titration Control Precision | 0.015 mL |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.005 mL |
| Water Content Range | 1 ppm to 100% H₂O |
| Accuracy (10 mL Burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 |
| Repeatability | ±0.005 mL |
| Burette Unit | EBU-710-KF |
| Titration Control Precision | 0.015 mL |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 Sample Records |
| GLP Compliance | Operator Logging, Reagent Tracking, Performance Verification, Time-Stamped Audit Trail |
| Connectivity | RS-232C, USB (Host & Device), SS-BUS (APB) |
| Optional Accessories | ADP-611 Coulometric/KF Oven, Solvent Exchange Unit, Dual Burette Module |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Kyoto Electronics Manufacturing Co., Ltd. |
| Type | Imported Instrument |
| Model | CHA-740 / CHA-760 |
| Instrument Category | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Potential Range | −2000.0 mV to +2000.0 mV |
| pH Range | −20.000 to +20.000 pH |
| Burette Accuracy | ±0.01 mL (20 mL burette) |
| Burette Resolution | 0.001 mL (20 mL burette) |
| Titration Precision | ±0.02 mL (20 mL burette) |
| Sample Capacity | 24 (CHA-740) / 47 (CHA-760) positions |
| Washing Modes | Rinse & Immersion, up to 3 wash solutions |
| Wash Liquids | Deionized water, ethanol, acetic acid, etc. |
| Operating Environment | 5–35 °C, ≤85 % RH |
| Power Supply | DC 24 V / 5 A (changer unit), AC 100–240 V / ~120 W |
| Dimensions (W×D×H) | 805×660×540 mm (CHA-740), 1005×760×540 mm (CHA-760) |
| Standard Sample Vessels | 200 mL plastic beakers, 200/250/300 mL glass beakers, tall-form beakers, Erlenmeyer flasks |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | PD-31N / PD-31 |
| Measurement Principle | Transient Hot Wire Method |
| Dimensions (L×W×H) | 100 × 50 × 20 mm |
| Thermal Conductivity Range | 0.058–5.0 W/(m·K) |
| Accuracy | ±5% |
| Repeatability | ±3% |
| Operating Temperature Range | −100 to +1000 °C |
| Measurement Duration | 100–120 s |
| Sample Dimensions | ≥100 × 80 × 40 mm (minimum two specimens) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | PD-13N / PD-13 |
| Measurement Principle | Hot Wire Method |
| Dimensions (L×W×H) | 110 × 50 × 100 mm |
| Accuracy | ±5% |
| Thermal Conductivity Range | 0.03–12 W/m·K |
| Repeatability | ±3% |
| Operating Temperature Range | −10 to 200 °C |
| Standard Measurement Time | 60 s |
| Sample Size Requirement | ≥100 × 50 × 20 mm (sheet form) |
| Minimum Thickness for Film Samples | 0.1 mm (for k = 0.1 W/m·K), 5 mm (for k = 5 W/m·K) |
| Compatible With | QTM-710/QTM-700 (PD-13N), QTM-500 (PD-13) |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | WBGT-301 |
| Price | Upon Request |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrumentation |
| Models | AT-710M, AT-710S, AT-710B |
| Pricing | Available Upon Request |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MKV-710M |
| Titration Method | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 1/20,000 |
| Moisture Content Range | 1 ppm to 100% H₂O |
| Accuracy (10 mL Burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 of burette volume |
| Repeatability | ±0.005 mL |
| Burette Capacity | 10 mL |
| Titration Control Precision | 0.005 mL |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 sample records |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | RA-620 / RA-600 |
| Price | Upon Request |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MKH-710M |
| Titration Mode | Fully Automated |
| Instrument Type | Dual-Mode Karl Fischer Moisture Analyzer (Volumetric & Coulometric) |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 500 mg H₂O |
| Accuracy | ±0.3% RSD (n=10) |
| Minimum Dispensing Increment | 0.1 µg |
| Repeatability | ±0.3% RSD |
| Burette Control Accuracy | ±0.3% |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 measurement records |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CHD-502C |
| Instrument Type | Oscillating U-Tube Densimeter |
| Form Factor | Benchtop Laboratory System |
| Sample Phase | Liquid Only |
| Density Range | 0–3 g/cm³ |
| Density Resolution | 1×10⁻⁶ g/cm³ |
| Density Repeatability | ±1×10⁻⁶ g/cm³ |
| Temperature Control | External Circulating Bath (4 °C to Ambient) |
| Sample Capacity | 30 × 20 mL Vials |
| Minimum Sample Volume | 1–2 mL |
| Viscosity Handling | Up to 50,000 mPa·s (via Integrated Vacuum-Pressure Pump) |
| Power Supply | AC 100–120 / 200–240 V, 50/60 Hz, ~40 W |
| Dimensions | 610 × 445 × 392 mm (W×D×H) |
| Weight | 24 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | DA-8XX + RA-6XX |
| Product Type | Benchtop Refractometer & Density Meter |
| Temperature Control | Peltier-controlled, 0–100 °C (density), 5–75 °C (refractometer) |
| Digital Display | Yes |
| Refractive Index Range | 1.32000–1.70000 nD |
| Brix Range | 0.00–100.00% |
| Refractive Index Accuracy | ±0.0001 nD |
| Density Measurement Principle | U-tube oscillation method |
| Density Range | 0–3 g/cm³ |
| Density Accuracy (DA-860) | ±0.000003 g/cm³ |
| Density Repeatability (DA-860) | ±0.000001 g/cm³ |
| Sample Volume | ~1 mL |
| Viscosity Correction | Built-in automatic correction |
| Auto-sampling | Integrated peristaltic pump with auto-drying judgment |
| Interface | LAN, USB, RS-232C |
| Compliance | ASTM D1250, ISO 12185, ISO 2859, USP <841>, GLP/GMP-ready audit trail support |
Show next