BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
ManufacturerYes
Import StatusImported
ModelDA-100
Instrument TypeOscillating U-Tube Densimeter
Form FactorBenchtop Laboratory Instrument
Sample TypeLiquids Only
Density Range0–3 g/cm³
Density Accuracy±0.001 g/cm³
Temperature Control Range15–40 °C (±0.1 °C stability, ±0.5 °C accuracy)
Repeatability0.001 g/cm³
Resolution0.001 g/cm³
Minimum Sample Volume~1 mL
DisplayLCD
Measurement Time20–90 s
Calibration StandardsDry air and double-distilled water
Data InterfaceRS-232C
Power SupplyAC 100–240 V, 50/60 Hz, 30 W
Dimensions275 × 350 × 165 mm (W×D×H)
Weight~6 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
ManufacturerKyoto Electronics Manufacturing Co., Ltd.
TypeImported Instrument
ModelPCD-500
Instrument CategoryGeneral-Purpose Automatic Potentiometric Titrator
Application ScopeUniversal
Measurement PrincipleStreaming Potential Detection
Electrode Output Range±2 V DC
Power SupplyAC 100–240 V ±10%, 50/60 Hz
Power Consumption~10 W
Dimensions (W×D×H)250 × 210 × 400 mm
Weight~4.5 kg
Sample HandlingStirred beaker-based immersion configuration
Piston ActuationContinuously variable vertical reciprocation
Minimum Detectable Charge Concentration≥1 × 10⁻⁵ mol/L (dilution required for high-concentration samples)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
ModelDA-860
Measurement PrincipleU-Tube Oscillation Method
Standard ComplianceASTM D4052-22, EN ISO 12185:1996, EN ISO 15212-1:1999, GB/T 2013-2010, GB/T 29617-2013, SH/T 0604-2000
Density Range0–3 g/cm³
Accuracy±0.000003 g/cm³
Repeatability±0.000001 g/cm³
Temperature Control0–100 °C (Peltier), Resolution: 0.001 °C
Sample Volume~1 mL (syringe) or ~2 mL (pump)
Measurement Time~10 s (to 4-digit stability)
InterfaceLAN, USB, RS-232C
PowerAC 100–240 V, 50/60 Hz
Dimensions295 × 330 × 255 mm
Weight~19 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoto Electronics Manufacturing (KEM)
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeBenchtop Density Meter & Refractometer
Temperature ControlPeltier-regulated (0–96°C for density, 5–75°C or optional 5–100°C for refractometry)
DisplayFull-color touchscreen LCD
Sample Volume~1 mL per measurement
Measurement PrincipleU-tube oscillation (density), Critical-angle light refraction at Na-D line (589.3 nm)
Density Range0–3 g/cm³ (model-dependent resolution: 1×10⁻⁶ g/cm³ for DA-650, 1×10⁻⁵ g/cm³ for DA-645, 1×10⁻⁴ g/cm³ for DA-640)
Refractive Index RangenD = 1.32000–1.58000 (RA-620) or 1.3200–1.7000 (RA-600)
Refractive Index Accuracy±0.00002 nD (RA-620) / ±0.0001 nD (RA-600)
Brix Range0.00–100.00% (RA-620), 0.0–100.0% (RA-600)
Brix Accuracy±0.014% (RA-620), ±0.1% (RA-600)
Viscosity CompensationBuilt-in dynamic correction algorithm for high-viscosity liquids
Auto-samplingIntegrated peristaltic pump with automated rinse, purge, and dry-cycle detection
Data Storage300 measurement records, 100 user-defined methods
ConnectivityLAN, USB, RS-232C
ComplianceDesigned to support GLP/GMP workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
ManufacturerYes
Instrument TypeLaboratory Benchtop Densitometer
Measurement PrincipleU-Tube Oscillation Method
Sample TypeLiquids Only
Density Range0–3 g/cm³
Density Accuracy±1×10⁻⁴ g/cm³
Density Resolution & Repeatability0.0001 g/cm³ / SD ≤5×10⁻⁵ g/cm³
Temperature Control Range0–96 °C (Peltier-regulated)
Temperature Accuracy±0.05 °C
Temperature Resolution0.01 °C
Minimum Sample Volume1–2 mL
Auto-SamplingIntegrated peristaltic pump with rinse/dry cycle
ComplianceASTM D4052, ISO 12185, BS EN ISO 15212-1, GB/T 2013, GB 5009.2, JJG 1058, GLP-ready data audit trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
ManufacturerYes
Import StatusImported
ModelADP-611
Titration ModeFully Automated
Instrument TypeVolumetric or Coulometric Karl Fischer Moisture Analyzer Compatible
Measurement Resolution0.1 µg
Moisture Content Range1 ppm to 100%
Accuracy≤0.3% RSD
Minimum Dispensing Volume0–16 mL
Titration Control Precision±0.3%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoto Electronics Manufacturing (KEM)
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelHF-48
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
ManufacturerYes
Import StatusImported
ModelADP-512S
Titration ModeFully Automatic
Instrument TypeVolumetric & Coulometric Karl Fischer Moisture Analyzer
Measurement Resolution0.1 µg
Water Content Range10 µg – 300 mg H₂O
Accuracy≤0.3%
Minimum Dispensing Volume0.1 µg
Titration Control Precision±0.3%
Power SupplyAC 100–240 V, 50/60 Hz, ~600 W
Heating Temperature Range50–1000 °C
Evaporation Tube MaterialQuartz
Sample Boat MaterialQuartz
Sample Capacity10 mL
Dimensions835(W) × 340(D) × 345(H) mm
Weight18 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
ManufacturerYes
Import StatusImported
ModelCHD-502N
Instrument TypeOscillating U-tube Densimeter
Form FactorBenchtop Laboratory System
Sample PhaseLiquid Only
Density Range0–3 g/cm³
Density Resolution1 × 10⁻⁶ g/cm³
Density Repeatability±1 × 10⁻⁶ g/cm³
Temperature Control Range0–96 °C
Minimum Sample Volume1–2 mL
Sample Capacity30 vials (20 mL glass bottles)
Integrated Vacuum/Pressure PumpYes, rated for up to 50,000 mPa·s viscosity
Power SupplyAC 100–120 V / 200–240 V, 50/60 Hz, ~40 W
Dimensions (W×D×H)582 × 445 × 392 mm
Weight17 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelDCU-551N
Instrument TypeOscillating U-Tube Densimeter
Form FactorBenchtop Laboratory Instrument
Sample PhaseLiquid Only
Density Range0–3 g/cm³
Temperature Control Range0–96 °C
Repeatability±1 × 10⁻⁶ g/cm³
Resolution0.000001 g/cm³
Minimum Sample Volume1–2 mL
Viscosity CompatibilityUp to 50,000 mPa·s (via integrated vacuum-pressure pump)
Sample Vessel20 mL glass vial
Power SupplyAC 100–120 V / 200–240 V, 50/60 Hz, ~40 W
Dimensions (W×D×H)291 × 310 × 342 mm
Weight10 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoto Electronics Manufacturing (KEM)
OriginJapan
ManufacturerYes
Import StatusImported
ModelD&S AERD
PricingUpon Request
Measurement PrincipleThermopile-based differential temperature method per ASTM C1371
Wavelength Range3–30 µm
Emissivity Range0.01–1.00
Repeatability±0.01 emittance units
Response Time~10 s
Display Accuracy±0.3% of reading
Operating Temperature−10 to +40 °C
Dimensions (H×W×D)51 × 80 × 152 mm
Weight~370 g
Detector Output~2.5 mV
Power SupplyDC 9 V (host), AC 100–240 V (charger)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
ManufacturerYes
Import StatusImported
ModelDCU-600
Instrument TypeOscillating U-tube Density Meter Accessory
Form FactorBenchtop Laboratory Unit
Sample TypeLiquids Only
Density Range0–3 g/cm³
Temperature Control Range0–96 °C
Minimum Sample Volume~5 mL
CompatibilityDesigned exclusively for KEM DA-640, DA-645, and DA-650 digital density meters
Automation FunctionsAutomated sample aspiration, measurement triggering, waste discharge, dual-solvent cleaning (Wash 1 & Wash 2), nitrogen-assisted drying, and cell integrity verification
Sample Vessel20–100 mL beaker or 100 mL disposable cup
Power SupplyDC 24 V, 5 A (AC adapter included)
Dimensions (W×D×H)214 × 295 × 304 mm
WeightApprox. 5.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeVolumetric Karl Fischer Moisture Analyzer
ModelMKV-710B
Measurement Resolution0.005 mL
Water Content Range1 ppm to 100% H₂O
Titration Accuracy (10 mL burette)±0.015 mL
Minimum Dispensing Increment1/20,000
Titration Control Precision0.015 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeVolumetric Karl Fischer Titrator
Titration ModeFully Automatic
Measurement Resolution0.005 mL
Water Content Range1 ppm to 100% H₂O
Accuracy (10 mL Burette)±0.015 mL
Minimum Dispensing Increment1/20,000
Repeatability±0.005 mL
Burette UnitEBU-710-KF
Titration Control Precision0.015 mL
Power SupplyAC 100–240 V, 50/60 Hz
Data Storage Capacity500 Sample Records
GLP ComplianceOperator Logging, Reagent Tracking, Performance Verification, Time-Stamped Audit Trail
ConnectivityRS-232C, USB (Host & Device), SS-BUS (APB)
Optional AccessoriesADP-611 Coulometric/KF Oven, Solvent Exchange Unit, Dual Burette Module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
ManufacturerKyoto Electronics Manufacturing Co., Ltd.
TypeImported Instrument
ModelCHA-740 / CHA-760
Instrument CategoryGeneral-purpose Potentiometric Titrator
Application ScopeUniversal
Potential Range−2000.0 mV to +2000.0 mV
pH Range−20.000 to +20.000 pH
Burette Accuracy±0.01 mL (20 mL burette)
Burette Resolution0.001 mL (20 mL burette)
Titration Precision±0.02 mL (20 mL burette)
Sample Capacity24 (CHA-740) / 47 (CHA-760) positions
Washing ModesRinse & Immersion, up to 3 wash solutions
Wash LiquidsDeionized water, ethanol, acetic acid, etc.
Operating Environment5–35 °C, ≤85 % RH
Power SupplyDC 24 V / 5 A (changer unit), AC 100–240 V / ~120 W
Dimensions (W×D×H)805×660×540 mm (CHA-740), 1005×760×540 mm (CHA-760)
Standard Sample Vessels200 mL plastic beakers, 200/250/300 mL glass beakers, tall-form beakers, Erlenmeyer flasks
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoto Electronics Manufacturing (KEM)
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported Instrument
ModelPD-31N / PD-31
Measurement PrincipleTransient Hot Wire Method
Dimensions (L×W×H)100 × 50 × 20 mm
Thermal Conductivity Range0.058–5.0 W/(m·K)
Accuracy±5%
Repeatability±3%
Operating Temperature Range−100 to +1000 °C
Measurement Duration100–120 s
Sample Dimensions≥100 × 80 × 40 mm (minimum two specimens)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
ManufacturerYes
Import StatusImported
ModelPD-13N / PD-13
Measurement PrincipleHot Wire Method
Dimensions (L×W×H)110 × 50 × 100 mm
Accuracy±5%
Thermal Conductivity Range0.03–12 W/m·K
Repeatability±3%
Operating Temperature Range−10 to 200 °C
Standard Measurement Time60 s
Sample Size Requirement≥100 × 50 × 20 mm (sheet form)
Minimum Thickness for Film Samples0.1 mm (for k = 0.1 W/m·K), 5 mm (for k = 5 W/m·K)
Compatible WithQTM-710/QTM-700 (PD-13N), QTM-500 (PD-13)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoto Electronics Manufacturing (KEM)
OriginJapan
ManufacturerYes
Import StatusImported
ModelWBGT-301
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrumentation
ModelsAT-710M, AT-710S, AT-710B
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
ManufacturerYes
Import StatusImported
ModelMKV-710M
Titration MethodFully Automatic Volumetric Titration
Instrument TypeVolumetric Karl Fischer Moisture Analyzer
Measurement Resolution1/20,000
Moisture Content Range1 ppm to 100% H₂O
Accuracy (10 mL Burette)±0.015 mL
Minimum Dispensing Increment1/20,000 of burette volume
Repeatability±0.005 mL
Burette Capacity10 mL
Titration Control Precision0.005 mL
Power SupplyAC 100–240 V, 50/60 Hz
Data Storage Capacity500 sample records
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelRA-620 / RA-600
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelMKH-710M
Titration ModeFully Automated
Instrument TypeDual-Mode Karl Fischer Moisture Analyzer (Volumetric & Coulometric)
Measurement Resolution0.1 µg
Water Content Range1 µg – 500 mg H₂O
Accuracy±0.3% RSD (n=10)
Minimum Dispensing Increment0.1 µg
Repeatability±0.3% RSD
Burette Control Accuracy±0.3%
Power SupplyAC 100–240 V, 50/60 Hz
Data Storage Capacity500 measurement records
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
ManufacturerYes
Import StatusImported
ModelCHD-502C
Instrument TypeOscillating U-Tube Densimeter
Form FactorBenchtop Laboratory System
Sample PhaseLiquid Only
Density Range0–3 g/cm³
Density Resolution1×10⁻⁶ g/cm³
Density Repeatability±1×10⁻⁶ g/cm³
Temperature ControlExternal Circulating Bath (4 °C to Ambient)
Sample Capacity30 × 20 mL Vials
Minimum Sample Volume1–2 mL
Viscosity HandlingUp to 50,000 mPa·s (via Integrated Vacuum-Pressure Pump)
Power SupplyAC 100–120 / 200–240 V, 50/60 Hz, ~40 W
Dimensions610 × 445 × 392 mm (W×D×H)
Weight24 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
ManufacturerYes
Import StatusImported
ModelDA-8XX + RA-6XX
Product TypeBenchtop Refractometer & Density Meter
Temperature ControlPeltier-controlled, 0–100 °C (density), 5–75 °C (refractometer)
Digital DisplayYes
Refractive Index Range1.32000–1.70000 nD
Brix Range0.00–100.00%
Refractive Index Accuracy±0.0001 nD
Density Measurement PrincipleU-tube oscillation method
Density Range0–3 g/cm³
Density Accuracy (DA-860)±0.000003 g/cm³
Density Repeatability (DA-860)±0.000001 g/cm³
Sample Volume~1 mL
Viscosity CorrectionBuilt-in automatic correction
Auto-samplingIntegrated peristaltic pump with auto-drying judgment
InterfaceLAN, USB, RS-232C
ComplianceASTM D1250, ISO 12185, ISO 2859, USP <841>, GLP/GMP-ready audit trail support