Empowering Scientific Discovery

Eutech CyberScan PCD650 Portable Multiparameter Water Quality Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Origin Singapore
Manufacturer Type Authorized Distributor
Origin Category Imported
Model PCD650
Pricing Upon Request
Instrument Type Laboratory-Grade Portable Water Quality Analyzer

Overview

The Eutech CyberScan PCD650 is a laboratory-grade, IP67-rated portable multiparameter water quality analyzer engineered for high-precision field and benchtop deployment in environmental monitoring, wastewater treatment, aquaculture, drinking water validation, and academic research. Built upon the proven CyberScan 600 platform, it employs simultaneous electrochemical and galvanic sensor-based measurement principles to deliver concurrent, non-interfering readings of pH, oxidation-reduction potential (ORP), specific ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen (DO), and temperature. Its architecture integrates dual-sensor compensation logic—automatically applying temperature, atmospheric pressure, and salinity corrections—to ensure metrological traceability across diverse aqueous matrices. The instrument complies with GLP data integrity requirements, including timestamped measurements, full audit trail capability, and electronic calibration logging—making it suitable for regulated environments aligned with ISO/IEC 17025, EPA Method 150.1, and ASTM D1125–22.

Key Features

  • Simultaneous real-time display of up to four parameters on a backlit 5.4 × 7.1 cm LCD, with integrated electrode status and calibration diagnostics
  • pH accuracy of ±0.002 pH with selectable resolution (0.1 / 0.01 / 0.001) and up to six-point auto-buffer recognition
  • Ion-selective measurement with 3-digit resolution and up to eight-point calibration; accuracy ±0.5% for monovalent ions, ±1% for divalent ions
  • Conductivity measurement across five auto-ranging spans (0–500 mS/cm), supporting both two- and four-ring electrodes with cell constant auto-detection (0.010–10.000 cm⁻¹)
  • Dissolved oxygen quantification via polarographic-free galvanic cell technology—no polarization delay required—with extended range (0.00–90.00 mg/L) and dual-unit output (mg/L and % saturation)
  • Integrated barometric pressure sensor (450–825 mmHg) enabling automatic DO and conductivity compensation per USP and ISO 7888
  • GLP-compliant data management: 500-station memory with date/time stamping, calibration history, and electrode ID tracking
  • Wireless IrDA and RS232C interfaces for secure data export; compatible with Eutech’s EcoScan PC software for report generation and trend analysis
  • Robust housing rated IP67 for dust-tight operation and submersion up to 1 m for 30 minutes; operational temperature range: 0–50 °C

Sample Compatibility & Compliance

The PCD650 is validated for use with natural waters (freshwater, seawater, estuarine), treated effluents, potable supplies, process streams, and ultrapure water systems. Its galvanic DO sensor eliminates zero drift associated with polarographic alternatives, while its high-range conductivity mode (up to 500 mS/cm) supports brine and industrial electrolyte analysis. All electrochemical modules conform to IEC 61000-6-2 (EMC immunity) and IEC 61000-6-3 (emission). Calibration protocols align with ISO 17025 Clause 6.4.6 for measurement uncertainty estimation. Data storage meets FDA 21 CFR Part 11 requirements when used with validated software workflows, including user authentication, electronic signatures, and audit trail retention.

Software & Data Management

The included EcoScan PC software enables configuration, firmware updates, batch calibration import/export, and automated report generation in PDF or CSV format. Each stored reading includes metadata: parameter ID, measured value, unit, timestamp, operator ID (if assigned), electrode serial number, calibration date, and environmental compensation values (temperature, pressure, salinity). Audit logs record all configuration changes, calibration events, and data deletions—supporting internal QA reviews and external regulatory inspections. Exported datasets are structured for direct ingestion into LIMS platforms compliant with ASTM E1468–21.

Applications

  • Regulatory compliance monitoring per EPA NPDES permits and EU WFD Annex V protocols
  • In-process verification in pharmaceutical water systems (PW, WFI) per USP and Ph. Eur. 2.2.42
  • Performance validation of membrane filtration, deionization, and reverse osmosis units
  • Ecological field studies requiring rapid, multi-parameter profiling of surface and groundwater
  • Educational laboratories conducting standardized APHA/AWWA/WEF method training (e.g., Standard Methods 4500-B, 2580-B, 4500-OC)
  • Aquaculture facility management—tracking DO minima, pH stability, and salinity gradients across life-cycle stages

FAQ

Does the PCD650 support automatic temperature compensation for all parameters?
Yes—ATC is applied independently to pH, conductivity, TDS, salinity, resistivity, and DO using either built-in NTC thermistor or external probe input.
Can the instrument store calibration data for multiple electrodes?
Yes—each electrode type (pH, ORP, conductivity, DO, ion-selective) retains its own calibration history, including slope, offset, date, and buffer/reference values.
Is the DO sensor replaceable in the field without tools?
Yes—the galvanic DO module features a quick-release bayonet mount and requires no recalibration after replacement.
What is the battery life under continuous logging mode?
With alkaline AAA cells, typical operation exceeds 200 hours; battery level indicator and auto-shutdown (2–30 min configurable) optimize longevity.
Does the PCD650 meet GLP requirements for audit-ready data?
Yes—it provides full traceability: unique ID per measurement, immutable timestamps, electronic calibration records, and password-protected user access levels.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0