Empowering Scientific Discovery

HUANKONG GHD-1000 Summa Canister Flow Calibrator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HUANKONG
Origin Shandong, China
Manufacturer Type Direct Manufacturer
Model GHD-1000
Pricing Available Upon Request

Overview

The HUANKONG GHD-1000 Summa Canister Flow Calibrator is a precision-engineered instrument designed specifically for the traceable calibration of flow controllers used in pressurized and evacuated air sampling systems—particularly those employing electropolished stainless-steel Summa canisters. It operates on the principle of controlled vacuum generation and dynamic flow measurement under defined negative pressure conditions, replicating the thermodynamic and fluidic behavior encountered during real-world canister-based volatile organic compound (VOC) sampling per EPA Method TO-14A, TO-15, and ASTM D6196. The system maintains a stable, programmable vacuum level (typically adjustable within the range of –5 to –30 psi absolute, consistent with standard Summa canister evacuation protocols), enabling accurate volumetric flow verification across variable backpressures typical of adsorbent tube and canister inlet configurations.

Key Features

  • Real-time vacuum simulation: Reproducibly generates and sustains calibrated negative pressure environments matching Summa canister operational specifications (e.g., 10–25 psi vacuum, ±0.2 psi stability over 30 min).
  • Multi-point flow calibration capability: Supports sequential automated calibration at up to six user-defined flow rates (e.g., 0.1–2.0 L/min), each validated against NIST-traceable primary standards.
  • Integrated high-accuracy thermal mass flow sensor: Certified accuracy of ±1.0% of reading (full scale), with temperature and pressure compensation compliant with ISO 17025 calibration requirements.
  • Programmable vacuum control loop: Digital PID regulation ensures vacuum setpoint adherence within ±0.15 psi, minimizing drift during extended calibration cycles.
  • Intuitive touchscreen interface with onboard data logging: Stores calibration events—including date/time stamp, setpoints, measured values, operator ID, and pass/fail status—for audit-ready GLP/GMP documentation.
  • Robust architecture: Stainless-steel gas path components (316L SS), chemically inert seals (Kalrez®), and leak-tight construction (<1×10⁻⁹ atm·cm³/s He) suitable for VOC, SVOC, and halogenated compound applications.

Sample Compatibility & Compliance

The GHD-1000 is fully compatible with standard 6-L and 1-L Summa canisters (SilcoNert®-treated), as well as alternative evacuated containers meeting EPA Compendium Method TO-14/TO-15 dimensional and valve interface specifications. Its calibration methodology aligns with regulatory expectations for field instrument verification outlined in EPA Guidance Document QA/G-5S (2021), ISO/IEC 17025:2017 Clause 6.5.2 (Verification of Equipment), and USP Analytical Instrument Qualification. All factory calibrations are performed using NIST-traceable reference standards; certificate of calibration includes uncertainty budget per GUM (JCGM 100:2008). The device supports 21 CFR Part 11-compliant electronic records when paired with optional secure software modules.

Software & Data Management

The embedded firmware supports USB export of CSV-formatted calibration reports containing raw sensor outputs, environmental parameters (T, P), and statistical summaries (mean, SD, %RSD). Optional PC-based Calibration Manager Software provides advanced features including automated report generation (PDF/Excel), instrument fleet management, scheduled calibration reminders, and integration with LIMS via HL7 or ASTM E1384 interfaces. Audit trails record all configuration changes, calibration actions, and user logins with immutable timestamps—fully compliant with GLP and GMP data integrity principles (ALCOA+).

Applications

  • Calibration and verification of flow controllers in ambient air monitoring networks (e.g., EPA SLAMS, state PM/VOC sites)
  • Field validation of portable sampling pumps prior to fence-line or source emission perimeter sampling (e.g., Refinery fenceline monitoring per 40 CFR Part 63, Subpart CC)
  • Quality assurance for mobile laboratory deployments in emergency response (e.g., chemical release incidents, hazmat events)
  • Supporting method validation studies for new canister-based sampling protocols under ISO 16000-6 or EN 13670-1
  • Periodic performance checks of fixed-site air quality stations operating in grid-based atmospheric observation systems

FAQ

What vacuum levels does the GHD-1000 support, and how is stability verified?
The unit delivers adjustable vacuum from –5 to –30 psi absolute, with stability maintained at ±0.15 psi over 30-minute intervals, verified by internal pressure transducer traceable to NIST SRM 2087.
Can it calibrate both mass flow controllers (MFCs) and volumetric flow meters?
Yes—it accommodates both analog and digital MFCs (0–5 V, 4–20 mA, RS-485 Modbus) and mechanical rotameters, applying real-time T&P correction per ISO 6145-4.
Is the GHD-1000 suitable for use in explosive atmospheres?
No—this model is rated for general laboratory and field use only (IP54 enclosure); intrinsic safety certification (ATEX/IECEx) is not included but may be available upon special order.
Does it comply with EPA Method TO-15 calibration requirements?
Yes—the multi-point flow verification protocol, documented uncertainty reporting, and traceability framework satisfy Section 8.3.2 and Appendix A of EPA TO-15 Rev. 2 (2022).
How often should the internal flow sensor be recalibrated?
Annual recalibration is recommended; however, users must perform daily zero checks and weekly span verification using certified reference gases or gravimetric standards per QA/QC Plan requirements.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0