Empowering Scientific Discovery

HUIFEN AGS-30(60) Automated Gas Sampler

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HUIFEN Instrument
Origin Shandong, China
Manufacturer Type Authorized Distributor
Product Category Domestic
Model AGS-30(60)
Instrument Type Gas Chromatography Autosampler
Sampling Modes Bag, Syringe, and Loop Injection (Optional)
Calibration Fully Automated Multi-Point Dilution Calibration
Cleaning Integrated Pre- and Post-Injection Tubing & Loop Purge
Control Interface 7-inch Capacitive Touchscreen + Optional PC Remote Control (Synchronized GUI)
Gas Dilution Programmable Proportional Mixing of Standard or Sample Gases
Compliance Designed for ISO/IEC 17025-aligned QC labs and GLP-compliant environmental & industrial gas analysis workflows

Overview

The HUIFEN AGS-30(60) Automated Gas Sampler is an engineered solution for high-throughput, reproducible gas introduction into gas chromatography (GC) systems. Built on a modular pneumatic architecture with solenoid-valve-driven flow control and pressure-regulated carrier gas management, the AGS-30(60) supports quantitative loop injection, syringe-based sampling, and flexible gas bag interfacing—enabling seamless integration into routine environmental monitoring, industrial emissions testing, and laboratory-based calibration workflows. Its core operational principle relies on precise timed actuation of calibrated sample loops (optional), programmable dilution ratios via mass-flow-controlled mixing, and closed-loop pressure stabilization to ensure volumetric accuracy across variable ambient conditions. Unlike manual or semi-automated alternatives, the AGS-30(60) eliminates operator-dependent variability in injection timing, volume consistency, and carryover mitigation—critical for meeting regulatory data integrity requirements in ISO 10156, EPA Method TO-15, and ASTM D6420 applications.

Key Features

  • Automated multi-point calibration: A single certified standard gas cylinder can be used to generate up to six concentration levels through sequential dilution—each step validated by real-time pressure decay monitoring and flow-rate confirmation.
  • Integrated loop cleaning protocol: Before and after each injection cycle, the system purges both the sample transfer line and the quantitative loop using inert carrier gas at controlled flow and dwell time, reducing cross-contamination to <0.1% RSD (measured via consecutive blank injections).
  • Dual-control interface: Local operation via a responsive 7-inch capacitive touchscreen with intuitive workflow navigation; optional Ethernet-enabled PC software allows remote scheduling, method upload, and synchronized live display of valve positions, loop fill status, pressure traces, and run progress.
  • Flexible sample handling: Compatible with Tedlar® gas sampling bags (1–10 L), glass/gas-tight syringes (1–10 mL), and stainless-steel quantitative loops (0.5–5 mL, optional); all interfaces include leak-tested Swagelok® fittings and pressure-rated seals.
  • Programmable gas dilution engine: Supports binary or ternary gas mixing using up to three independently regulated inlet streams; dilution ratios range from 1:1 to 1:1000 with ±1.5% volumetric repeatability (verified per ISO 6145-2 gravimetric reference standards).

Sample Compatibility & Compliance

The AGS-30(60) accommodates non-reactive and moderately reactive gases including CO, CO₂, CH₄, NOₓ, SO₂, VOCs (e.g., benzene, toluene), and permanent gases (O₂, N₂, H₂, He). All wetted materials—316L stainless steel tubing, PTFE diaphragms, and Kalrez® O-rings—are selected for chemical inertness and low outgassing. The system meets mechanical safety requirements per EN 8230-1 for gas-handling equipment and supports audit-ready data logging compliant with FDA 21 CFR Part 11 when paired with validated PC software (electronic signatures, user access tiers, and immutable audit trails enabled). It is routinely deployed in laboratories accredited to ISO/IEC 17025 for air quality testing and aligns with QA/QC protocols outlined in US EPA Compendium Method TO-14A and ISO 16017-1 for indoor air VOC analysis.

Software & Data Management

The optional HUIFEN GC-Sampler Control Suite (v3.2+) provides method-based automation, including sequence definition, event-triggered dilution, and dynamic loop volume adjustment. All acquisition parameters—including valve timing, purge durations, pressure setpoints, and dilution factors—are stored as encrypted XML method files. Raw operational logs (timestamped valve actuations, pressure transients, error codes) are written to local SSD storage and exportable in CSV/ASCII format for LIMS integration. Software validation documentation (IQ/OQ/PQ templates) and electronic record retention policies are available upon request for GxP-regulated environments.

Applications

  • Environmental air monitoring: Continuous calibration verification for ambient VOC analyzers and fixed-site emission monitors.
  • Industrial hygiene: Batch analysis of workplace breathing-zone samples collected in gas bags per NIOSH Method 1501.
  • Method development labs: Rapid screening of GC column performance under varied gas matrix conditions.
  • Reference material producers: Certified gas mixture preparation traceable to NIST SRMs via gravimetric-dilution correlation.
  • Academic research: Controlled delivery of reactive gas blends for catalytic reaction studies coupled with online GC-MS detection.

FAQ

Is the AGS-30(60) compatible with all major GC brands?
Yes—it outputs standardized TTL-level trigger signals and accepts external start commands via dry-contact closure or RS-232, enabling synchronization with Agilent, Thermo Fisher, Shimadzu, and PerkinElmer GC platforms.
Can the system be validated for GLP or ISO 17025 compliance?
Yes—full validation support packages (including installation qualification templates, operational test protocols, and performance verification checklists) are provided for IQ/OQ execution.
What maintenance intervals are recommended?
Valve manifold inspection every 6 months; loop and tubing replacement annually or after 5,000 cycles—whichever occurs first—based on typical use in EPA-compliant labs.
Does the AGS-30(60) support unattended overnight operation?
Yes—integrated watchdog circuitry monitors pressure stability, communication latency, and thermal drift; automatic fault recovery or safe shutdown is initiated if predefined thresholds are exceeded.
Is helium-free operation possible?
Yes—the system operates with nitrogen, argon, or synthetic air as carrier gas; helium conservation mode reduces consumption by up to 70% during standby and purge phases without compromising loop fill fidelity.