Empowering Scientific Discovery

Beijing Ligtai Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelCMP21
Spectral Range285–2800 nm
Sensitivity7–14 µV/W/m²
Response Time5 s
Zero Offset A< 7 W/m²
Zero Offset B< 2 W/m²
Directional Error (up to 80°, 1000 W/m² beam)< 10 W/m²
Temperature Dependence of Sensitivity (−20 °C to +50 °C)< 1 %
Operating Temperature Range−40 °C to +80 °C
Maximum Solar Irradiance4000 W/m²
Field of View180°
Output Signal0–20 mV (passive, no power required)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLI-COR
OriginUSA
ModelLI-7810
Measurement PrincipleOptical Feedback–Cavity Enhanced Absorption Spectroscopy (OF-CEAS)
Gases MeasuredCH₄, CO₂, H₂O
Detection LimitsSub-ppb CH₄, <0.1 ppm CO₂, <0.01% RH H₂O
Power Requirement12–24 V DC (LI-7810)
Operating Temperature–25 to 45 °C
CommunicationEthernet, Wi-Fi, Bluetooth (8200-01S), USB, RS-232
Data OutputReal-time flux calculations (CH₄ & CO₂), soil temperature & moisture (via optional sensors), diagnostic logs
ComplianceDesigned for GLP-compliant field deployment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLI-COR
OriginUSA
ModelLI-8250
Gas Analyzers SupportedLI-7810 (CH₄/CO₂/H₂O) or LI-870 (CO₂/H₂O)
Max Channels36 (via 8250-01 expansion modules)
Chamber Types8200-104 (opaque) or 8200-104C (transparent)
Data Storage8 GB internal
Operating Temperature–20 to 45 °C
Humidity Range0–95% RH (non-condensing)
Enclosure RatingIEC IP55
Power Input10–30 VDC
Wi-Fi2.4 GHz, 802.11 a/b/g/n/ac
GPS Accuracy2.5 m CEP
Max Chamber Radius15.0 m (single line), 30.0 m (with 8250-01)
Pressure Sensor Range20–110 kPa (±0.4 kPa accuracy)
Flow Rate to Chambers~2–3 L/min
SoftwareSoilFluxPRO™
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETER
OriginUSA
ModelS2-421-SS (upward), S2-422-SS (downward)
PrincipleEffective photosynthetically active radiation (PAR)-weighted reflectance measurement
TypePortable canopy-mounted optical sensor
Spectral peaks532 ± 2 nm and 570 ± 2 nm
FWHM10 nm per channel
Field of view180° (S2-421-SS), 35° (S2-422-SS)
Cosine response error±2% @ 45°, ±5% @ 75° zenith angle
Calibration uncertainty±5%
Measurement repeatability<1%
Long-term drift<2% per year
Response time<0.6 s
Operating temperature−40 to +70 °C
Relative humidity range0–100% RH
IP ratingIP68
Power supply5.5–24 V DC
OutputSDI-12
HousingAnodized aluminum with acrylic diffuser
Cable5 m shielded twisted pair, TPR jacket, stainless steel (316) strain relief
Weight (incl. cable)140 g (S2-421-SS), 110 g (S2-422-SS)
DimensionsØ30.5 × 37 mm (S2-421-SS), Ø23.5 × 43 mm (S2-422-SS)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDynamax
OriginUSA
ModelSapIP-MICRO
Instrument TypeWireless Mesh-Based Environmental Monitoring System
Data TransmissionLoRaWAN / Cellular (SPIP-CELL optional)
Network TopologySelf-Healing Mesh
Max Nodes per Network25
Inter-Node Range300–500 m (line-of-sight, SPIP-24K radio)
Operating Temperature−40 to +70 °C
Relative Humidity Range0–100 % RH
Accuracy±3 % RH (0–90 % RH, 20 °C), ±5 % RH (90–100 % RH)
Air Temperature Range−40 to +60 °C
Accuracy±0.6 °C
Solar Radiation Range0–2000 W/m²
Spectral Response360–1120 nm
Absolute Accuracy±5 %
Rainfall Resolution0.25 mm
Accuracy±4 % or ±1 tip (0.2–50.0 mm/hr)
Wind Speed Range0–50 m/s
Accuracy±0.5 m/s
Wind Direction Range0–360°
Accuracy±5°
Onboard Memory30,000 records
Power7 Ah rechargeable battery + 10 W solar panel
Input Channels8 differential analog inputs
ETP CalculationFAO-56 Penman-Monteith supported in firmware
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginGermany
ModelCHM15K
Measurement Range5 m to 15,000 m
Laser Wavelength1064 nm
Laser Class1M (per DIN EN 60825-1:2007)
Power Supply230 VAC ±10%, 250 W (standard), 800 W (heating mode)
Operating Temperature−40 °C to +50 °C
Enclosure RatingIP65
Dimensions500 × 500 × 1550 mm
Weight70 kg (130 kg with packaging)
Data Output FormatsNetCDF, ASCII, XML
Communication InterfacesRS485, Ethernet (LAN), optional RS232 / modem
Sampling Frequency100 MHz
Vertical Resolution15 m (full range), 5 m (0–150 m)
Minimum Detection Height5 m
Pulse Repetition Rate5–7 kHz
Measurement CycleAdjustable from 2 s to 600 s
Safety ComplianceEN 61326-1, EN 61010-1, ISO 10109-11
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLI-COR
OriginUSA
ModelLI-7500RS
CO₂ Range0–3000 µmol/mol
H₂O Range0–60 mmol/mol
Accuracy (CO₂/H₂O)<1%
Zero Drift (CO₂)±0.1 µmol/mol/°C (typ.), ±0.3 µmol/mol/°C (max.)
Zero Drift (H₂O)±0.03 mmol/mol/°C (typ.), ±0.05 mmol/mol/°C (max.)
RMS Noise @5 Hz (CO₂)0.08 µmol/mol
RMS Noise @5 Hz (H₂O)0.0034 mmol/mol
Gain Drift (CO₂)±0.02% /°C (typ.)
Gain Drift (H₂O)±0.15% /°C (typ.)
Cross-Sensitivity (CO₂ to H₂O)±2.0×10⁻⁵ mol CO₂/mol H₂O (typ.)
Cross-Sensitivity (H₂O to CO₂)±0.02 mol H₂O/mol CO₂ (typ.)
Sampling Rate150 Hz
Bandwidth Options5, 10, or 20 Hz
DetectorThermoelectrically Cooled PbSe
Optical Path Length12.5 cm
Air Temperature Sensor10 kΩ thermistor (–40 to 70 °C
Pressure Sensor20–110 kPa (±0.4 kPa accuracy)
Operating Temp–25 to 50 °C (extendable to –40 °C)
IP RatingIP65
Power10.5–30 VDC
Power Consumption4 W (typ.), ≤8 W (full range)
Probe DimensionsØ6.5 × 30 cm
Probe Weight0.67 kg (1.3 kg with base)
DSI Box Dimensions13.24 × 14.64 × 6.24 cm (H×W×D)
DSI Box Weight0.93 kg
Data InterfaceEthernet
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETER
OriginUSA
ModelTEROS 31
Measurement Range–150 to +50 kPa (standard range: –85 to +50 kPa)
Temperature Range–30 to 60 °C
Resolution±0.0012 kPa / ±0.01 °C
Accuracy±0.15 kPa / ±0.5 °C
Output ProtocolsSDI-12, Modbus RTU, TensioLink, DDI Serial
Power Supply3.6–28.0 VDC
Dimensions23.5 × 17.5 × 49.0 mm
Ceramic Tip Area0.5 cm²
Rod Diameter5 mm
Cable Length1.5 m
Connector3.5 mm 4-pole stereo plug
Operating Temperature0–50 °C
CertificationsISO 9001:2015, CE (EN ISO/IEC 17050:2010)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelJLT 4 and JLT 6
Instrument TypeElectric Multi-Position Stirrer
Speed Range10–300 rpm (1 rpm increment)
Temperature ControlAmbient only
Power Supply100–240 V, 50–60 Hz
Dimensions (W×H×D)JLT 4 — 645×347×260 mm
WeightJLT 4 — 13 kg
Power ConsumptionJLT 4 — 11 W
Illuminated DisplayYes
Adjustable Stirring Rod HeightYes, with self-locking chuck
Timer Range0–999 min or 0–99 h (continuous mode available)
ComplianceCE, RoHS, IEC 61010-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGill
OriginUnited Kingdom
Instrument TypeUltrasonic Anemometer
Resolution0.01 m/s
Measurement Sampling Frequencies1, 2, 4, 8, 10, 16, 20 Hz (32 Hz optional)
Accuracy< ±0.5% @ 20°C (Speed of Sound), < ±1° RMS (Wind Direction), < 1% RMS (Wind Speed @ ≤30° incidence)
Operating Temperature-40°C to +70°C
Relative Humidity Range5%–100% RH
Ingress ProtectionIP65
Wind Speed Range0–45 m/s
Wind Direction Range0–359°
Ultrasonic Temperature RangeNot applicable (HS-50 model lacks integrated PRT)
Output InterfacesRS422 full-duplex, 8 data bits, 1 stop bit, no parity
Baud Rate2400–115200 bps
Output FormatUVW vector components + Speed of Sound
Power Supply9–30 V DC (<150 mA @ 24 V DC or 300 mA @ 12 V DC)
Dimensions1305 mm × 344 mm × 120 mm
Weight2.5 kg
Housing MaterialStainless steel
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelROTAX 6.8
Power Supply115 V / 230 V, 50–60 Hz
Rated Power100 W
Speed Range0–30 rpm
DisplayLCD
Sample Capacity6 × 2 L bottles or 8 × 1 L bottles
Bottle Compatibility2 L PE bottles (H: 220–280 mm, Ø ≤ 135 mm)
1 L PE bottles (H200–270 mm, Ø ≤ 110 mm)
Dimensions (W×H×D)665 × 520 × 470 mm
Weight30 kg
ConstructionEpoxy-coated metal frame
Accessories AvailablePolyethylene bottles (1 L / 2 L), 8-position 1 L bottle adapter (2 pcs/box), round glass bottle caps (2 L)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelSMP22
Spectral Range210–3600 nm
Response Time (63%)< 0.5 s
Response Time (95%)< 0.2 s
Zero Offset A< 3 W/m²
Zero Offset B< 1 W/m²
Directional Error (up to 80°, 1000 W/m² beam)< 5 W/m²
Temperature Dependence of Sensitivity (−20 °C to +50 °C)< 0.3 %
Analog Output (-V)0–1 V
Analog Output (-A)4–20 mA
Digital Output2-wire RS-485
Supply Voltage5–30 VDC
Integrated Desiccant Lifetime≥10 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLI-COR
OriginUSA
ModelBiomet
Instrument TypeIntegrated Eddy Covariance-Compatible Biometeorological Sensor System
ComplianceDesigned for ASTM D7289, ISO 16485, and FLUXNET-compatible data acquisition frameworks
Data SynchronizationTime-synchronized with LI-COR gas analyzers (e.g., LI-7200/7810) and ultrasonic anemometers (e.g., LI-7500A/RS) via DAqM module
Software IntegrationFully compatible with SmartFlux® and EddyPro® v8.2+ for flux partitioning, gap-filling, and uncertainty propagation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLI-COR
OriginUSA
ModelLI-250A
Sensor TypeSilicon Photodiode
Accuracy (25 °C)±0.4% of full scale ±3 digits
Accuracy (0–55 °C)±0.6% of full scale ±3 digits
Range SelectionAuto-ranging across 3 scales
Linearity±0.05%
DisplayDigital LCD, 0.5 s update in instantaneous mode
PowerOne 9 V alkaline battery (150 h typical life)
Operating Environment0–55 °C, 0–95% RH (non-condensing)
Storage−55–60 °C, 0–95% RH (non-condensing)
Dimensions14 × 7.7 × 3.8 cm
Weight0.26 kg
IP RatingRain- and dust-resistant (O-ring sealed enclosure)
Signal Averaging15 s moving average (~60 samples)
Input InterfaceBNC connector for LI-COR radiation sensors
CalibrationUser-entered sensor-specific calibration coefficient
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelCMP10
Spectral Range285–2800 nm
Sensitivity7–14 µV/W/m²
Response Time< 5 s
Zero Offset A< 7 W/m²
Zero Offset B< 2 W/m²
Directional Error (up to 80°, 1000 W/m² beam)< 10 W/m²
Temperature Dependence of Sensitivity (−10 °C to +40 °C)< 1 %
Operating Temperature Range−40 °C to +80 °C
Maximum Irradiance4000 W/m²
Field of View180°
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Kipp & Zonen
OriginNetherlands
ModelCMP22
Spectral Range200–3600 nm
Sensitivity7–14 µV/W/m²
Response Time5 s
Zero Offset A< 3 W/m²
Zero Offset B< 1 W/m²
Directional Error (up to 80°, 1000 W/m² beam)< 5 W/m²
Temperature Dependence of Sensitivity (−20 °C to +50 °C)< 0.5 %
Operating Temperature Range−40 °C to +80 °C
Maximum Irradiance4000 W/m²
Field of View180°
Output Signal0–20 mV (passive, no power required)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETER
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelKSAT
Instrument TypeSoil Water Potential & Moisture Analyzer
Measurement Range0.01–5,000 cm/d
Porous Plate Hydraulic Conductivity (Ks)14,000 cm/d
Pressure Sensor Accuracy±1 Pa (0.01 cm H₂O)
Temperature Sensor Accuracy±0.2 °C
Sample Ring Volume250 mL (Ø80 mm × H50 mm), with optional 100 mL adapter
Typical Statistical Error under Constant Head/Constant Flow Conditions~2%
Software RequirementsWindows 7 or later, Microsoft .NET Framework 3.5
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLI-COR
OriginUSA
ModelLI-190R
Measurement Range0 to >10,000 μmol·m⁻²·s⁻¹
Spectral Range400–700 nm
Calibration Uncertainty±5%
Sensitivity5–10 μA per 1000 μmol·m⁻²·s⁻¹
Linearity Error≤1% up to 10,000 μmol·m⁻²·s⁻¹
Response Time<1 μs
Temperature Dependence<0.15%/°C
Cosine Response Error<±1% at 82° zenith angle
Operating Environment−40 to +65°C, 0–100% RH (non-condensing)
DetectorBlue-enhanced silicon photovoltaic cell
HousingAnodized aluminum with acrylic diffuser and stainless-steel mounting hardware
Dimensions2.36 cm Ø × 3.63 cm H
WeightSensor head: 24 g
2 m cable with base60 g
Cable Options2 m, 5 m, 15 m, 50 m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDynamax
OriginUSA
ModelDEX
Measurement PrincipleResistive Strain-Bridge Displacement Sensing with Integrated Temperature Compensation
Operating Temperature Range–10 to 50 °C
Accuracy±0.050 mm (for ΔT > 20 °C)
Temperature Stability0.0025 mm/°C
Output SignalAnalog ±5 mV or ±2.5 mV (model-dependent)
Sensitivity0.05–0.5 mV/mm
Linearity Error±0.004 to ±0.01 mV/mm
Electrical Noise±0.01 mV
Compatible Data LoggersSupports up to 8 or 32 sensors per system
IP-Rated EnclosureSealed Electronics for Outdoor & Field Deployment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLI-COR
OriginUSA
ModelLI-3000C
Resolution1 mm²
Accuracy< ±2% for leaf area > 50 cm²
Display2-line × 16-character LCD
Memory2.1 MB flash storage (65,000–125,000 measurements)
Data InterfaceRS-232 and USB 1.1
Power6 V rechargeable lead-acid battery (12–15 h operation) or 115/230 V AC, 50/60 Hz, 20 W
Operating Environment0–55 °C, 0–95% RH (non-condensing)
Scan Head Dimensions30.5 cm length, 6.4 mm LED source width, 680 g
Controller Dimensions19.8 × 15.5 × 10.1 cm, 2.0 kg
Max Sample Width127 mm
Max Sample Thickness8 mm
Max Sample Length1 m
Max Scan Speed1 m/s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETER
OriginUSA
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelZL6
Instrument TypeCompact Wireless Weather Station
PowerIntegrated Solar Panel + Rechargeable NiMH Battery
Data ConnectivityGSM (2G/3G) to Zentra Cloud
Local Storage Capacity40,000–80,000+ records
Sensor Interfaces6 universal analog/digital ports
IP RatingIP67 enclosure
Operating Temperature Range–25°C to 60°C
ComplianceFCC Part 15, CE, RoHS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelSER 148
Extraction Chamber Volume150 mL
Receiver Flask Volume100 mL
Temperature Range100–260 °C
Temperature Control Accuracy±1 °C
Channel Capacity3 or 6 positions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelRespirometric Sensor System 6
Pressure Range500–2000 hPa
Sensor Count6
Test Vessel Capacity1000 mL
Data Acquisition Interval10 min – 48 h
Test Duration1–180 days
Stirrer Speed Control6-digit digital setting with lock function
Sensor Power2 W
Battery TypeCR2430
Sensor Dimensions50 × 70 × 70 mm
Sensor Weight80 g
Stirrer Unit Dimensions230 × 51.5 × 370 mm
Stirrer Unit Weight1.75 kg
Ingress ProtectionIP54 (EN 60529)
Safety ComplianceIEC/EN 61010-1
Databox™ Capacityup to 48 sensors (8 systems × 6 sensors)
ConnectivityUSB (RESPIROSoft™) or optional Wi-Fi (Ermes™ Cloud Platform)
SoftwareRESPIROSoft™ v5.x with audit trail, method templates, report generation, and battery-level monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETER
OriginUSA (Designed & Engineered in Germany)
ManufacturerMETER Group GmbH & Co. KG (formerly UMS)
ModelTEROS 32
TypePressure-Based Tensiometer
ComplianceISO 9001:2015, CE (2014/30/EU & 2011/65/EU), ISO/IEC 17050:2010
Measurement Range-85 to +50 kPa (soil water potential), -30 to +60 °C (temperature)
Resolution0.0012 kPa, ±0.01 °C
Accuracy±0.15 kPa, ±0.1 °C (-20–40 °C), ±1 °C (outside range)
Output ProtocolsSDI-12, DDI serial, TensioLINK™, Modbus RTU
Power Supply4.0–28.0 VDC
Enclosure RatingIP68
Ceramic Cup MaterialAl₂O₃ (AI203), Bubble Point: 1500 kPa
Rod MaterialPMMA
Corpus MaterialPOM-GF (glass-fiber-reinforced polyoxymethylene)
Probe Length Options40 cm / 80 cm / 120 cm
Diameter2.5 cm
Cable OptionsStandard 5 m, up to 75 m custom
Connector Types3.5 mm stereo jack (4-pin), M12 (4-pin), or tinned bare wire
Installation Angle-80° to -10° (upward), +10° to +80° (downward)
Operating Temperature-30 °C (dry), 0 °C (hydrated), max 50 °C
Ceramic Cup Warranty10 years
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0