- All
- Favorite
- Popular
- Most rated
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (PRC) |
| Model | DSC0901 |
| Pricing | Available Upon Request |
| Differential Heat Range | ±2000 µV |
| DSC Power Range | ±10, ±20, ±50, ±100, ±160, ±200 mW (auto-switching) |
| Temperature Range Options | RT–450°C, RT–1150°C, RT–1400°C, RT–1650°C |
| Heating Rate | 0.1–30 °C/min (programmable) |
| Temperature Control Modes | Ramp, Isothermal, Cooling, PID-regulated |
| Base Resolution | 2 µg |
| Sensitivity | 10 µg |
| TGA Capacity | 1–1000 mg (selectable ranges) |
| DTG Range | 0.1–10 mg/min (selectable) |
| Gas Flow Control | Dual-channel mass flow controllers (N₂, O₂), ≤200 mL/min |
| Max Sample Load | 2 g |
| A/D Resolution | 24-bit |
| Data Output | Printer, chart recorder, PC interface |
| Power Supply | 220 V AC ±1 Hz, 50 Hz |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | PCY-SL-30 |
| Price Range | USD 1,400–7,000 |
| Temperature Range | −30 °C to 30 °C |
| Heating Rate | 5 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Sample Diameter | 6–10 mm |
| Measurement Range | 5 mm |
| Resolution | 1 µm |
| Atmosphere Options | Air, Vacuum, Inert Gas |
| Brand | ZHENHUAFENXI |
|---|---|
| Model | XPY |
| Temperature Range | RT to 1000 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Accuracy | ±1 °C (at 1000 °C) |
| Sample Dimensions | Ø6–8 mm × up to 50 mm L |
| Measurement Range | ±5 mm |
| Resolution | 1 µm |
| Sample Holder Material | Fused Quartz |
| Compliance Standards | GB/T 4100–2015, GB/T 3810.9–2016 |
| Software Platform | Windows 10/7/XP |
| Brand | ZHENHUAFENXI |
|---|---|
| Origin | Hunan, China |
| Model | DRL-III |
| Measurement Principle | Heat Flow Method |
| Thermal Conductivity Range | 0.010–50 W/m·K |
| Accuracy | ±3% |
| Repeatability | ±1% |
| Temperature Range | Ambient to 200 °C (Hot Plate), 0–99.99 °C (Cold Plate) |
| Sample Diameter | Ø10–30 mm |
| Sample Thickness | 0.02–20 mm |
| Thermal Resistance Range | 5×10⁻⁶ – 0.05 m²·K/W |
| Pressure Range | 0–1000 N |
| Displacement Resolution | 0.01 mm |
| Dimensions (L×W×H) | 60 cm × 58 cm × 90 cm |
| Compliance Standards | ASTM E1530, ASTM C518, ISO 8301, DIN EN 12939, DIN EN 13163, DIN EN 12667, JIS A 1412 |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TA-10 |
| Pricing | Upon Request |
| Max Operating Temperature | 1000 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | <1% of reading |
| Heating Rate Control | 5 ± 1 °C/min (PID-regulated, fully automated) |
| Test Method | Fiber Draw Method (ASTM C336, SJT 11039–1996, JC/T 752–1996) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GYH-A |
| Pricing | Available Upon Request |
| Max Operating Temperature | 1650 °C |
| Heating Rate | 0–10 °C/min |
| Temperature Uniformity at Hold | ±2 °C |
| Gas Flow Control Range | 1–10 L/min |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GFT-1600 |
| Price Range | USD 7,000–14,000 |
| Instrument Class | High-Temperature Vacuum Contact Angle Measurement System |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0°–180° |
| Contact Angle Measurement Accuracy | ±0.2° (not % — corrected per metrological convention) |
| Fixed Sample Stage Diameter | 30 mm |
| Optical Magnification | 50–318 pixels/mm |
| Surface/Interfacial Tension Measurement Range | 0.01–2000 mN/m |
| Temperature Range | Ambient to 1700 °C (continuous operation ≤1600 °C) |
| Temperature Accuracy | ±2 °C (full scale) |
| Temperature Resolution | ±1 °C |
| Heating Element | Molybdenum-Rhodium (Mo–Rh) resistance furnace (1.5 mm wire diameter) |
| Atmosphere Control | Vacuum or inert gas (N₂, Ar) compatible |
| Imaging Sensor | USB 2.0 digital CCD, ≥5 MP, 25 fps |
| Microscope Zoom | 0.7×–4.5× continuous zoom (total optical magnification: 20×–200×) |
| Image Resolution | 2048 × 1536 pixels |
| Illumination | Adjustable-intensity monochromatic LED cold light source |
| Thermal Protection | Dual overtemperature and overcurrent safety cutoffs |
| Software | Dedicated image-based contact angle & interfacial tension analysis suite with time–temperature–contour synchronized logging |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | HWX-II |
| Price | Upon Request |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | SKE-10KN |
| Quotation | Upon Request |
| Load Capacity | 10,000 N |
| Platen Diameter | 50 mm |
| Stroke | 150 mm |
| Loading Rate Range | 5–700 N/s |
| Force Accuracy | ±0.1 % FS |
| System Accuracy | 0.5 % |
| Power Supply | 220 V, 50 Hz |
| Motor Power | 800 W |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | LM |
| Pricing | Upon Request |
| Sample Capacity | 2 or 8 tiles (selectable) |
| Sample Size | 100 × 100 mm |
| Rotational Speed Range | 300–3000 rpm |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MIL-II |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Measurement Range | 1–200 mN/m |
| Resolution | 0.05 mN/m |
| Accuracy | ±0.1 mN/m |
| Temperature Display Range | 0–100 °C |
| Temperature Display Accuracy | ±0.1 °C |
| Primary Method | Du Noüy Ring / Wilhelmy Plate (Detachment Force Method) |
| Contact Angle Range | 0–180° |
| Contact Angle Resolution | ±0.1° |
| Imaging System | ≥5 MP CCD camera, ≥30 fps |
| Data Acquisition Rate | 50 readings/sec |
| Repeatability | <0.3% RSD |
| Compliance Standards | ISO 8296:2003, ISO 6295:1983, ASTM D971, GB/T 14216–2008 |
| Sample Holder Options | 50 mm / 70 mm / 100 mm diameter cups |
| Power Supply | 85–264 V AC, 40–60 Hz |
| Power Consumption | 40 W (operational), 5 W (standby) |
| Interfaces | 2 × USB 2.0 |
| Lift Travel | 100 mm (manual or motorized option) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DRX-II-300A |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Guarded Hot Plate Method |
| Measurement Range | 0.01–2.2 W/m·K |
| Repeatability | ±1.0% |
| Accuracy | ±2.5% |
| Thickness Capacity | Up to 200 mm |
| Cold Plate Temp Range | −40 °C to +60 °C |
| Hot Plate Temp Range | Ambient to 110 °C (optional up to 300 °C or 600 °C) |
| Temperature Control Precision | ±0.1 °C |
| Temp Resolution | 0.01 °C |
| Sample Size | 200 × 200 × (5–20) mm or 300 × 300 × (5–100) mm |
| Power Supply | AC 220 V ±5%, 3.0 kW |
| Compliance | GB/T 10294–2008, ASTM C518, ISO 8302 |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China-made) |
| Model | PCY-DL-100 |
| Pricing | Upon Request |
| Test Temperature Range | Up to 80 °C (extendable to 200 °C with alternative heat transfer medium) |
| Heating Method | Electromagnetic heating (2 kW) |
| Stirring | Adjustable-speed electromagnetic stirring |
| Sample Capacity | Dual-sample simultaneous testing |
| Standards Compliance | GB 12007.6–1989, ISO 4625:1980, ASTM D36 / E28, IP 58, DIN 52011, NF T 66-008, EN 1427 |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GTM-1 / GTM-2 |
| Load Capacity Options | 0–5 kN, 0–10 kN, 0–20 kN, 0–50 kN |
| Measurement Accuracy (Load) | ±0.15% FS |
| Deflection Range | ±5 mm |
| Deflection Accuracy | ±0.5% FS |
| Crosshead Speed | 0–1 mm/min (adjustable) |
| Temperature Capability | GTM-1 — Ambient only |
| Sample Dimension Tolerance per GB/T 1182 & GB/T 1031 | Parallelism ≤0.02 mm, Perpendicularity ≤0.02 mm, Surface Roughness Rz ≤1.60 µm |
| Compliance Standards | GB 10700–2006, GB/T 6569, GB/T 1182, GB/T 1031 |
| Brand | ZHENHUAFENXI |
|---|---|
| Model | DRX-II-JG |
| Measurement Principle | Laser Flash Method (LFA) |
| Temperature Range | RT to 1000 °C |
| Thermal Diffusivity Range | 0.01–1000 mm²/s |
| Thermal Conductivity Range | 0.1–1000 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ±2% (thermal diffusivity), ±3% (specific heat) |
| Sample Forms | Solid, Powder, Liquid, Film, Composite, Ceramic, Metal, Graphite, Polymer |
| Atmosphere Options | Ambient air, inert gas, oxidizing/reducing gas, vacuum (down to 10⁻³ Pa) |
| Sample Dimensions | Ø12–20 mm or ≥10×10 mm, thickness 0.1–10 mm (recommended 3 mm) |
| Detection | Infrared detector (non-contact) |
| Data Acquisition Rate | 2 MHz |
| Software Platform | Windows 10 (64-bit), GLP-compliant reporting, ASTM E2585 / ISO 22007-4 / GB/T 22588 / GJB 1201.1-91 compliant |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SJY-II-14/17 |
| Price Range | USD 1,400–7,200 (FOB) |
| Max. Temperature | 1400 °C / 1700 °C |
| Heating Rate | 0–10 °C/min |
| Temp. Accuracy | ±1 °C |
| Sample Dimensions | Ø6 mm × 8 mm (cylindrical) |
| Linear Measurement Range | 5 mm |
| Resolution | 0.1 nm |
| Atmosphere Options | Vacuum (≤1.0×10⁻² Pa), Inert Gas (N₂, Ar), or Ambient Air |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | DRX-II-LUX |
| Price | Upon Request |
| Measurement Principle | Steady-State Guarded Hot Plate (Modified ASTM C177 / ISO 8302 compliant architecture) |
| Heat Plate Diameter | Φ65 mm |
| Heat Plate Temp | 60 ± 0.1 °C (Pt100 controlled) |
| Cold Plate Temp | 20 ± 0.1 °C (water-cooled, Pt100 controlled) |
| Preheater Temp | 40 °C (optional) |
| Coolant Temp Control | 20 ± 0.5 °C |
| Coolant Flow Rate | 40 L/h |
| Temperature Differential Resolution | ±0.1 °C (via differential thermopile or dual Pt100) |
| Sample Dimension | Φ50 × 50 mm |
| Thickness Measurement Accuracy | ±0.01 mm (digital caliper) |
| Test Duration | 5–20 min |
| Contact Pressure | Manual or motorized preloading system |
| Max Power Consumption | ≤1.5 kW |
| Brand | ZHENHUAFENXI |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DRH-600 |
| Instrument Type | Guarded Hot Plate Method |
| Sample Capacity | Single specimen |
| Test Environment | Ambient pressure |
| Thermal Conductivity Range | 0.0015–3.0 W/m·K |
| Accuracy | ±3% |
| Repeatability | ±1% |
| Temperature Range (Cold Plate) | 0–99.9 °C |
| Temperature Range (Hot Plate) | Ambient to 99.9 °C |
| Specimen Dimensions (Max) | 600 × 600 × 200 mm |
| Specimen Flatness Tolerance | ≤0.5 mm |
| Thickness Measurement Range | 0–200 mm |
| Thickness Resolution | 0.01 mm |
| Applied Pressure Range | 0–1000 N |
| Pressure Resolution | 0.1 N |
| Temperature Resolution | 0.01 °C (Cold Plate), 0.1 °C (Hot Plate) |
| Power Supply | AC 220 V ±5%, 3.0 kW |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SQ005B |
| Pricing | Available Upon Request |
| Cold Water Pressure Range | 0.05–0.5 MPa (Accuracy Class 1.0) |
| Hot Water Pressure Range | 0.05–0.5 MPa (Accuracy Class 1.0) |
| Flow Rate Measurement Range | 0.05–0.6 L/s (Accuracy Class 1.0) |
| Power Supply | 380 VAC, 36 kW |
| Cold Water Temperature Control | Ambient to 10 ± 1 °C |
| Hot Water Temperature Control | Ambient to 90 ± 1 °C |
| Cold Water Tank Capacity | 300 L |
| Hot Water Tank Capacity | 350 L |
| Compliant Standards | AS 3588:1996, EN 14688:2015, EN 14516:2006, EN 13310:2015 |
| Brand | ZHENHUAFENXI |
|---|---|
| Origin | Hunan, China |
| Model | HDRX-RL03 |
| Measurement Principle | Heat Flow Meter (HFM) Method |
| Thermal Conductivity Range | 0.001–5 W/(m·K) |
| Accuracy | ±3% |
| Repeatability | ≤3% |
| Temperature Range | RT to 1000 °C |
| Sample Thickness Range | 0.5–60 mm |
| Thickness Resolution | 1 µm |
| Thickness Accuracy | ±0.01 mm |
| Applied Pressure Range | 0–3.0 MPa |
| Pressure Accuracy | <0.5% FS |
| Cold-Side Cooling | 10 L Precision Circulating Bath (−5 to 80 °C, 0.01 °C resolution) |
| Hot-Side Control | PID-regulated heating with multi-point real-time temperature monitoring |
| Compliance Standards | ASTM C518, ASTM E1530, ISO 22007-2 |
| Data Acquisition | 32-bit high-resolution ADC, modular architecture supporting specific heat and thermal diffusivity expansion modules |
| Brand | ZHENHUAFENXI |
|---|---|
| Origin | Hunan, China |
| Model | SQ006 |
| Maximum Furnace Temperature | 500 °C |
| Temperature Control Accuracy | ±2 °C at 500 °C |
| Effective Chamber Dimensions | 350 × 350 × 350 mm |
| Cold-to-500 °C Ramp Time | 120 min |
| Heating Power | 5 kW |
| Timer Range | 0–180 min |
| Air Compressor Capacity | 30 L |
| Air Compressor Power | 1 kW |
| Control Interface | 10-inch Industrial Touchscreen HMI with SCADA-based Configuration Software |
| Compliance | GB/T 25994–2010, GB/T 3810.9–2016 |
| Brand | ZHENHUAFENXI |
|---|---|
| Origin | Hunan, China |
| Model | GDT |
| Temperature Range | Ambient to 900 °C / 1400 °C / 1600 °C (selectable furnace configuration) |
| Constant Current Source | 0–40 A, 0–24 V, stability ±0.01 A |
| Sample Diameter | 20–50 mm |
| Sample Length | 100 mm (customizable) |
| Voltage Tap Spacing | Adjustable |
| Dimensional Measurement | Digital Caliper, 0–150 mm, resolution 0.01 mm |
| Voltage Measurement | Digital Voltmeter, 0–199.99 mV, resolution 0.01 mV |
| Temperature Controller | Japanese imported microcomputer-based programmable controller with SSR solid-state relay drive and universal thermocouple input (K, S, R types supported) |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GKZ-II- |
| Price Range | USD 7,000 – 14,000 |
| Maximum Test Load | 10 kN / 20 kN |
| Loading Speed Range | 0.01–700 mm/min (adjustable via servo motor) |
| Relative Indication Error | ±1% |
| Operating Temperature | Up to 1600 °C |
| Support Span | 100 mm or 125 mm (customizable) |
| Sample Capacity | 4 specimens (40 × 40 × 160 mm) |
| Atmosphere Control | Oxidizing, reducing, and programmable inert/reactive gas environments (N₂, H₂, Ar, He, CO, NH₃, H₂O vapor) |
| Loading Mechanism | Precision ball-screw actuator with closed-loop servo control |
| Data Acquisition | Industrial PC with Windows OS, proprietary software compliant with ASTM C1161, ISO 5013/5014, GB/T 3002, and GB/T 13243 |
| Brand | ZHENHUAFENXI |
|---|---|
| Origin | Hunan, China |
| Model | PM |
| Instrument Type | Portable Green Density Penetrometer |
| Application | Green density evaluation of non-metallic powder compacts (e.g., ceramic, graphite, refractory preforms) |
| Penetrator Tip Diameters | Ø0.5 mm, Ø0.75 mm, Ø1.0 mm (stainless steel) |
| Maximum Penetrator Travel Distance from Worktable | ~100 mm |
| Horizontal Distance from Penetrator Axis to Machine Frame | 210 mm |
| Test Load Options | Selectable dead-weight masses (kg) |