Empowering Scientific Discovery

Nova 970P Portable Synthesis Gas Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Nova
Origin Canada
Model 970P
Detection Principles NDIR (CO, CO₂, CH₄), Electrochemical (O₂), Thermal Conductivity (H₂)
Measurement Range O₂: 0–2.0%, 0–25.0%, 0–50.0%
CO/CO₂/CH₄/H₂ 0–2.0%, 0–50.0%
Resolution 0.1% (full scale)
Accuracy ±1.0–1.5% FS (gas-dependent)
Drift <1% FS over 8 h
T₉₀ Response Time 20–30 s
Operating Temperature 0–50 °C
Linearity ±1% FS per gas
Dimensions 25 × 25 × 35 cm
Weight 9 kg
Outputs 4–20 mA, 0–1 V, RS-232
Power Rechargeable battery (portable mode) or AC adapter (with active temperature stabilization)
Sample Handling Integrated pump, flowmeter, particulate filter, chemically resistant stainless-steel wetted path
Detector Options Replaceable CH₄-specific hydrocarbon detector (substitutes standard HC sensor)

Overview

The Nova 970P Portable Synthesis Gas Analyzer is an engineered solution for real-time, multi-component gas analysis in dynamic industrial and research environments. Designed and manufactured in Canada, the instrument employs a hybrid detection architecture: non-dispersive infrared (NDIR) spectroscopy for quantitative measurement of carbon monoxide (CO), carbon dioxide (CO₂), and methane (CH₄); electrochemical sensing for oxygen (O₂); and thermal conductivity detection (TCD) for hydrogen (H₂). This configuration ensures selective, interference-resistant quantification across complex synthesis gas matrices—such as those generated in biomass gasification, coal-derived syngas production, anaerobic digestion off-gas, and catalytic reforming processes. Unlike single-technology analyzers, the 970P integrates three independent optical and electrochemical sensing paths within a single compact chassis, enabling simultaneous, time-synchronized readings without cross-channel calibration drift. Its field-serviceable NDIR detectors feature replaceable optical filters and user-accessible cleaning ports—eliminating the need for factory recalibration after exposure to dusty or condensing sample streams.

Key Features

  • Triple-channel NDIR detection with individually optimized optical paths for CO, CO₂, and CH₄—each with dedicated spectral bandpass filters and temperature-stabilized detectors (AC-powered variant only)
  • Field-replaceable CH₄-specific hydrocarbon detector option, providing superior selectivity versus total hydrocarbons (THC) in mixed C₁–C₃ gas streams
  • Long-life electrochemical O₂ sensor (rated >24 months in ambient air; extended life under low-O₂, high-CO conditions)
  • Robust thermal conductivity cell for H₂, calibrated against certified reference standards traceable to NIST
  • Fully integrated sampling system: diaphragm pump (max. 1.2 L/min), laminar-flow digital flowmeter (±2% reading), sintered stainless-steel particulate filter (5 µm), and PTFE-coated sample hose
  • Chemically inert wetted path constructed from electropolished 316 stainless steel—validated for continuous exposure to H₂S, NH₃, HCl, and humidified syngas up to 80% RH
  • Rechargeable Li-ion battery pack (12 h typical runtime at 1 L/min flow); optional AC power supply enables active detector temperature control (±0.1 °C stability) for enhanced long-term reproducibility

Sample Compatibility & Compliance

The 970P is validated for direct analysis of raw, unconditioned synthesis gases containing variable concentrations of CO (0–50%), CO₂ (0–50%), CH₄ (0–50%), H₂ (0–50%), and O₂ (0–50%). It accommodates sample dew points up to 40 °C and tolerates particulate loading ≤10 mg/m³. Internal moisture management relies on passive condensate trapping and hydrophobic membrane filtration—no external chillers or dryers required for most biogas and gasifier applications. The analyzer complies with IEC 61000-6-2 (immunity) and IEC 61000-6-4 (emissions), and meets ATEX Zone 2 / UL Class I, Division 2 requirements when operated with optional intrinsically safe barrier kits. Data integrity protocols support GLP/GMP-aligned workflows: all measurements include embedded timestamps, sensor health diagnostics, and configurable audit trails compatible with FDA 21 CFR Part 11-compliant data acquisition systems.

Software & Data Management

The embedded firmware supports dual-mode operation: standalone field use via backlit LCD interface (real-time ppm/% display, min/max/avg logging, alarm thresholds) and PC-connected operation via RS-232 or USB-to-serial bridge. Nova’s free SynGasLink™ desktop software provides live trend visualization, customizable report generation (PDF/CSV), and automated calibration certificate export per ISO/IEC 17025 guidelines. All analog outputs (4–20 mA, 0–1 V) are independently scalable per gas channel and isolated to prevent ground-loop interference. Firmware updates are performed via secure signed binary upload, preserving user calibration coefficients and historical logs.

Applications

  • Real-time monitoring of biomass gasifier exit gas composition for process optimization and tar cracking efficiency assessment
  • In-line verification of syngas stoichiometry (H₂:CO ratio) prior to Fischer–Tropsch or methanol synthesis reactors
  • Biogas upgrading plant feedstock characterization and membrane separation performance validation
  • Landfill gas quality control during flaring or engine fuel conditioning
  • Lab-scale catalytic reaction screening where rapid H₂/CO/CO₂ turnover kinetics must be resolved
  • Environmental compliance reporting for EPA Method 3A (O₂), Method 10 (CO), and ASTM D1946 (CH₄/H₂ in fuel gas)

FAQ

Can the 970P measure gases other than CO, CO₂, CH₄, H₂, and O₂?
No—the instrument’s hardware architecture is fixed to these five components. Additional gases (e.g., NOₓ, SO₂, H₂S) require separate analyzers or OEM integration.
Is zero/span calibration required before each use?
Field zeroing using certified N₂ is recommended before critical measurements; full span calibration is advised every 30 days or after exposure to gas concentrations exceeding 80% of full scale.
Does the unit support automatic moisture compensation?
No—moisture correction is not applied algorithmically. However, the stainless-steel wetted path and hydrophobic filtration minimize condensation-induced signal attenuation in typical syngas applications.
What is the warranty coverage?
Nova provides a 24-month limited warranty covering materials and workmanship, excluding consumables (filters, O₂ sensor, battery) and damage from improper sample conditioning.
Can the CH₄-specific detector be retrofitted to an existing 970P unit?
Yes—field upgrade kits (including detector module, firmware patch, and calibration certificate) are available directly from Nova authorized service centers.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0