PMM EP-602 Electromagnetic Field Probe for RF Electric Field Measurement

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand PMM
Origin Italy
Model EP-602
Frequency Range 5 kHz to 9.25 GHz
Electric Field Measurement Range 1.5 V/m to 1500 V/m
Measurement Resolution 0.01 V/m
Isotropy (Typical) ±0.2 dB
Frequency Response Flatness (with correction enabled) ±0.4 dB (50 MHz – 7.5 GHz)
Dynamic Range >60 dB
Weight 22 g
Operating Time Up to 100 h (rechargeable Li-Mn battery)
Communication Duplex optical fiber (up to 60 m)
Sensor Type Spherical symmetric monopole array (6-axis isotropic sensing)
Overload Protection >3000 V/m

Overview

The PMM EP-602 is a high-fidelity, isotropic electric field probe engineered for precision electromagnetic field (EMF) characterization across an exceptionally broad frequency spectrum—from 5 kHz up to 9.25 GHz. Designed on the principle of spherical symmetry and calibrated monopole sensor geometry, the EP-602 employs six orthogonal single-pole sensors to deliver true vector-free, frequency-compensated E-field magnitude measurement. Its compact 53 mm diameter spherical housing minimizes field perturbation—critical in near-field EMC/EMI testing environments such as semi-anechoic chambers, TEM/GTEM cells, and radiated immunity test setups per IEC 61000-4-3 and MIL-STD-461. The probe operates without metallic shielding or internal active electronics in the sensing head, ensuring minimal loading effects and high spatial resolution. It is not a broadband meter but a traceable, calibration-grade transducer intended for integration into compliant test systems requiring metrological integrity and long-term stability.

Key Features

  • Isotropic response with typical deviation ≤ ±0.2 dB across full operating band—validated per ISO/IEC 17025-accredited calibration procedures
  • Optical fiber interface eliminates ground loops and RF pickup; supports bidirectional communication up to 60 meters without signal degradation
  • Rechargeable lithium-manganese oxide battery provides ≥100 hours of continuous operation under typical sampling conditions (0.4 samples/s with 28 Hz low-pass filter)
  • Full protocol openness: native support for SCPI-like command structure compatible with Keysight PathWave, Rohde & Schwarz EMCO, and LabVIEW-based custom automation frameworks
  • Integrated temperature and battery voltage monitoring with 0.1 °C and 10 mV resolution respectively—enabling real-time environmental drift compensation
  • Overload resilience exceeding 3000 V/m ensures operational safety during high-field transient exposure, including radar pulse and burst-mode immunity testing

Sample Compatibility & Compliance

The EP-602 is certified for use in accredited electromagnetic compatibility laboratories performing conformance testing to international standards including IEC 61000-4-3 (radiated RF immunity), IEC 61000-4-20 (transverse electromagnetic cell testing), and ANSI C63.4 (EMI emission measurements). Its mechanical design meets IP54 ingress protection requirements when used with standard fiber-optic feedthroughs. Calibration certificates are issued with NIST-traceable uncertainty budgets and include full-frequency isotropy matrix data. The probe complies with EU Directive 2013/35/EU on occupational EMF exposure assessment and supports GLP-compliant data acquisition workflows when paired with validated software platforms.

Software & Data Management

The EP-602 communicates via ASCII-based serial protocol over USB-RS232 adapter or directly through optical fiber using PMM’s OR-03 opto-electronic converter. Raw sensor outputs are delivered at up to 22 samples per second, with configurable digital filtering options: adjustable low-pass cutoff (2.3–28 Hz), 50/60 Hz notch (80 dB rejection), and programmable averaging windows. All firmware and correction coefficients—including frequency-dependent sensitivity tables and isotropy correction matrices—are stored onboard and auto-applied during measurement. Export formats include CSV (time-stamped E-field magnitude + XYZ components), binary .epd files for post-processing, and direct integration with MATLAB and Python via open API documentation.

Applications

  • Radiated immunity test site validation and field uniformity mapping in accordance with IEC 61000-4-3 Annex A
  • Near-field scanning of PCBs, antennas, and wireless modules for EMI source localization
  • Biological exposure assessment in laboratory settings (e.g., in vitro RF dosimetry studies)
  • Material characterization under RF excitation, including dielectric loss tangent estimation
  • Calibration transfer between reference field generators and working standards in national metrology institutes
  • Real-time four-channel synchronized monitoring using optional C4 multi-probe controller for spatial gradient analysis

FAQ

What is the recommended calibration interval for the EP-602?
Annual calibration is advised under routine laboratory use; however, recalibration is required after any mechanical impact, exposure beyond 3000 V/m, or if temperature-corrected drift exceeds ±0.5 dB over baseline.
Can the EP-602 be used in pulsed RF fields?
Yes—the probe’s passive sensor architecture and fast rise time (<1 ns) enable accurate peak and RMS detection of modulated and pulsed signals, provided sampling rate and filter settings match the pulse repetition frequency.
Does the EP-602 require external power at the probe head?
No—only the remote interface unit (OR-03 or compatible host) requires power; the probe itself is entirely passive and powered solely by its internal battery for onboard processing and telemetry.
Is the EP-602 suitable for outdoor environmental monitoring?
It is not rated for unenclosed outdoor deployment; however, it may be used inside weatherproof enclosures with optical feedthroughs for fixed-site RF survey applications, subject to thermal derating above 40 °C.
How is traceability maintained during field use?
Each unit ships with a unique calibration certificate referencing EURAMET cg-19 guidelines, including full-frequency isotropy data, linearity verification points, and uncertainty contributions from temperature, cable flex, and optical coupling loss.