- All
- Favorite
- Popular
- Most rated
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EHP-50C |
| Frequency Range | 5 Hz – 100 kHz |
| Axes | Simultaneous X/Y/Z vector measurement |
| Calibration Data Storage | Built-in EEPROM |
| Interface | Optical fiber (compatible with PMM 8053A field meter) |
| Signal Processing | Integrated DSP with selectable 7-band spectral resolution |
| Operating Temperature | −10 °C to +40 °C |
| Physical Form Factor | Compact cubic probe (dimensions not specified) |
| Power Management | Internal rechargeable battery with charging port |
| Status Indication | LED indicators for power/on/off and operational mode |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model Series | RA-01, RA-01-HV, BC-01, LP-02, LP-03, AS-02, AS-03 |
| Frequency Range Coverage | 9 kHz – 6 GHz (system-dependent) |
| Antenna Types | Rod, Biconical, Log-Periodic, Multi-Antenna Sets |
| HV Rating | Up to 20 kV/m (RA-01-HV, 150 kHz–30 MHz) |
| Compliance | Designed for CISPR 16-1-4, ANSI C63.4, MIL-STD-461, IEC 61000-4-3 |
| Brand | PMM |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | C4 |
| Price | Upon Request |
| Frequency Range | 1 Hz to 40 GHz |
| Measurement Resolution | 0.01 V/m |
| Electric Field Measurement Range | Determined by Connected E-Field Probe Specifications |
| Key | Frequency Range: 9 kHz–3 GHz (6600/6600D: up to 1 GHz) |
|---|---|
| Input Power Range | 100 nW–1 W (−40 dBm to +30 dBm) |
| Linearity | ±0.2 dB (typ.) |
| Measurement Modes | Forward & Reverse Power |
| Detection | True RMS, >70 dB dynamic range |
| Interface | USB 1.0/1.1/2.0 (6600/6600D: proprietary 486-style interface) |
| Units | dBm, W, Vrms |
| Compliance | CE, RoHS |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 9060 |
| Frequency Range | 30 MHz – 6 GHz |
| Frequency Resolution | 0.1 Hz |
| Measurement Accuracy | < 2 ppm |
| Input Impedance | 50 Ω, N-type female |
| VSWR | < 1.2 @ 0 dB attenuation, < 2.0 @ full attenuation |
| Attenuation Range | 0–55 dB (5 dB steps) |
| Pre-amplifier Gain | 10 dB |
| Max. Input Level (non-damaging) | 137 dBµV (1 W sine), 97 dBµV/MHz (pulse spectral density) |
| Preselector | Low-pass + six band-pass filters covering 30 MHz–1000 MHz and >1000 MHz |
| IF Bandwidths (3 dB) | 3, 10, 30, 100, 300 kHz, 1 MHz |
| IF Bandwidths (6 dB) | 120 kHz (CISPR 16-compliant) |
| Noise Floor | < 2 dBµV (QP, 200 Hz BW, 9–150 kHz), < −2 dBµV (AV, same BW) |
| Detectors | Peak, Quasi-Peak, Average, RMS, Smart Detector |
| Parallel Detection | Supported for Peak, QP, RMS, AV |
| Sweep Time | 1 ms – 30 s (CISPR 16 default) |
| Display Units | dBm, dBµV |
| SNR | > 20 dB |
| Amplitude Probability Distribution (APD) Capability | Yes |
| Tracking Generator Output | 10 Hz – 30 MHz, AM demodulation via PMM 9010 |
| Interface | High-speed optical fiber (≥2.5 Gb/s), RS-232 (service only) |
| Power Supply | 10–15 VDC, 2.5 A |
| Operating Temperature | 0 °C – 40 °C |
| Dimensions | 235 × 105 × 105 mm |
| Weight | 2.0 kg |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | 6000A |
| RF Signal Source | PMM 3010 |
| Power Amplifier Options | PMM 5042 or 7034 |
| Power Meter | PMM 6630 |
| Current Injection Clamp | OIP400 |
| Injection Current Capability | 200 mA, 300 mA, and 400 mA (peak) |
| Software | PIMS (Programmable Immunity Measurement System) |
| Hardware Architecture | Decentralized modular design |
| Instrument Interoperability | Compatible with R&S SMB100 series signal sources and third-party amplifiers/clamps per ISO 11452-4 |
| Compliance | Designed for ISO 11452-4, ISO 10605, SAE J1113/4, and CISPR 25 immunity validation |
| Frequency Range | 1–6 GHz |
|---|---|
| Maximum Input Power | 300 W |
| Gain (at 3 m distance) | 12.48 dBi @ 1 GHz |
| Origin | Italy |
| Type | Passive Wideband Horn Antenna |
| Compliance | Designed for EMC Radiated Emission & Immunity Testing per CISPR 16-1-4, ANSI C63.4, IEC 61000-4-3 |
| PMM | Brand |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PMM 9180 |
| Price | Upon Request |
| Brand | Lsi |
|---|---|
| Origin | Italy |
| Model | Bubuc |
| Compliance | ISO 7243, ISO 7933, ISO 7730, ISO 7726 |
| Input Channels | Up to 11 (BabucA) / 6 (BabucM) |
| Memory Capacity | Up to 256 KB (110,000 samples) |
| Power | Rechargeable battery or AC/DC adapter |
| Probe Interfaces | Auto-recognizing universal analog inputs |
| Data Output | RS-232, real-time monitoring, printer-compatible |
| Software Suite | InfoGAP-Base-PC, InfoGAP-Advance-PC, Microclima modules |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PMM 9030 |
| Pricing | Upon Request |
| Brand | Lsi (LSI-LASTEM) |
|---|---|
| Origin | Italy |
| Model | R-Log 7730 |
| Sensor Compliance | ISO 7726, ISO 7730 |
| Wireless Data Logger Memory | 2 MB |
| Channels | 5 |
| Battery | 1.2 A Li-ion |
| Interface | Mini-DIN, RS232 |
| Operating Temperature Range | −30 °C to +70 °C |
| Black Globe Temperature Range | −20 °C to +60 °C |
| Accuracy (Globe Temp) | ±0.5 °C (5–45 °C), ±1 °C (outside range) |
| Response Time (Globe) | 30 s |
| Dry/Wet-Bulb Temp Range | −20 °C to +60 °C |
| RH Range | 0–100% |
| RH Accuracy | ±2% (10–90% RH, 25 °C) |
| RH Response Time | 8 s |
| Hot-Wire Anemometer Range | 0.01–20 m/s |
| Turbulence Intensity (TU) Range | 0–100% |
| TU & Va Accuracy | ±5 cm/s (0–0.5 m/s), ±10 cm/s (0.5–1.5 m/s), ±4% (>1.5 m/s) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EP-602 |
| Frequency Range | 5 kHz to 9.25 GHz |
| Electric Field Measurement Range | 1.5 V/m to 1500 V/m |
| Measurement Resolution | 0.01 V/m |
| Isotropy (Typical) | ±0.2 dB |
| Frequency Response Flatness (with correction enabled) | ±0.4 dB (50 MHz – 7.5 GHz) |
| Dynamic Range | >60 dB |
| Weight | 22 g |
| Operating Time | Up to 100 h (rechargeable Li-Mn battery) |
| Communication | Duplex optical fiber (up to 60 m) |
| Sensor Type | Spherical symmetric monopole array (6-axis isotropic sensing) |
| Overload Protection | >3000 V/m |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | 6000C |
| Compliance Standards | IEC 61000-4-6, GB/T 17626.6 |
| Calibration Levels | 1 V, 3 V, and 10 V (per IEC 61000-4-6 Annex A) |
| Core Components | PMM 3010 RF Signal Generator, PMM 6000N/5048FE Power Amplifier, M3-16 Coupling/Decoupling Network (CDN), ATT-25W Attenuator, SW-06 Control & Calibration Software, Cab-06 Interconnection Cables |
| Optional Accessories | M-, AF-, S-, and T-type CDNs |
| Amplifier Upgrade Range | 15 W to 10,000 W |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Elog-dc |
| Pricing | Available Upon Request |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | SHC-1, SHC-1/1000, SHC-2 |
| Impedance | 1500 Ω |
| Attenuation | 35 dB (SHC-1 & SHC-1/1000), 30 dB (SHC-2) |
| Max Voltage Rating | 1 kV (SHC-1/1000 only) |
| Compliance | CISPR 16-1-2:2023, IEC 61000-4-6 |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | 9010F |
| Frequency Range | 10 Hz to 30 MHz (extendable to 3 GHz / 6 GHz / 18 GHz with optional modules 9030 / 9060 / 9018) |
| Compliance | CISPR 16-1-1, MIL-STD-461, DO-160 |
| Detection Modes | Peak, Quasi-Peak, Average, RMS, RMS-Average, CISPR-Average, APD |
| IF Bandwidths | 200 Hz, 9 kHz, 1 kHz–300 kHz (6 dB) |
| Resolution | 0.1 Hz |
| Frequency Accuracy | <1 ppm |
| Input Impedance | 50 Ω (BNC-f) |
| VSWR | <1.20 @ 10 dB attenuation |
| Max. Input Level | 137 dBµV (CW), 97 dBµV/MHz (pulse spectral density) |
| Built-in Preamp | +20 dB |
| Attenuation | 0–35 dB (5 dB steps) |
| Real-time FFT Sweep Speed | <5 s for CISPR Band A, <20 s for Band B (QPK, 1 s dwell) |
| Operating Temperature | –5 °C to +45 °C |
| Weight | 4.1 kg (with integrated Li-ion battery) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EP 601 |
| Frequency Range | 10 kHz – 9.25 GHz |
| Electric Field Measurement Range | 0.5 – 500 V/m |
| Resolution | 0.01 V/m |
| Overload Protection | > 1000 V/m |
| Dynamic Range | > 60 dB |
| Isotropy | ±0.5 dB |
| Amplitude Flatness | ±0.4 dB |
| Sensor Type | Six Monopole Antennas (Triaxial X/Y/Z) |
| Weight | 23 g |
| Dimensions | 21 mm (sphere diameter) × 16 mm (sensor length) × 53 mm (total length) |
| Operating Temperature | –10 °C to +50 °C |
| Power Supply | Rechargeable Li-ion Battery or External DC Input |
| Temperature Compensation | 0.1 °C per °C |
| Brand | PMM |
|---|---|
| Model | XC 9010 |
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | 6000R |
| Pricing | Available Upon Request |
| Brand | Lsi |
|---|---|
| Origin | Italy |
| Model | Babuc |
| Compliance | Pre-loaded ISO/TC 159/SC5 Standards |
| Core Indices | WBGT, PMV-PPD, HIS, TTS, SWreq, Ereq, DLE, TO, CET, Ep, SWp, Wp |
| Data Acquisition | BabucM (4/6-channel) or BabucA (11-channel) Logger |
| Sensors | BSU121 Natural Ventilation Wet-Bulb Probe, BST131 150-mm Black Globe Thermometer (ISO 7726), BSU102 Forced-Ventilation Psychrometer (ISO 7726), BSV101 Hot-Wire Anemometer (ISO 7726) |
| Software | InfoGAP-Base-PC (BSZ300), InfoGAP-Advance-PC (BSZ301), Microclima Module (BSZ303) |
| Power | BSC010 Rechargeable Battery Pack (7.2 Vdc) |
| Enclosure | BWA314 Rugged Transport Case |
| Mounting | BVA304 Tripod, BVA306 Sensor & Logger Bracket, BSD020 BabucM Mount |
| Connectivity | RS-232 (9-pin male), USB-to-RS232 Adapter Optional |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Other Test Accessories |
| Pricing | Upon Request |
| Brand | Lsi |
|---|---|
| Origin | Italy |
| Model | BSP002 |
| Measurement Range | 800–1100 hPa |
| Accuracy (20°C) | ±1 hPa |
| Resolution | 0.1 hPa |
| Thermal Drift | 3.3 hPa/10°C (-10…+60°C) |
| Response Time (T90) | 1 ms |
| Warm-up Time | 300 s |
| Operating Temperature | -40…+85°C |
| Long-term Stability | 1.1 hPa/year |
| Sea-level Compensation Range | -300…+2000 m ASL |
| Power Consumption | 10 mA |
| Output | Analog (1 channel), 2 m PVC cable |
| Sensor Element | Piezoresistive |
| Calibration Interval | 12 months |
| Compliance | ISO 9001-certified calibration (Certificate DZC001, Procedure PCR002) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 3010 / PMM 3030 |
| Frequency Range | 9 kHz – 1 GHz (3010) / 9 kHz – 3 GHz (3030) |
| Output Level | −107 dBm to +10 dBm |
| Modulation | Internal AM & Pulse Modulation |
| Interface | RS232, USB, User I/O Port |
| Power Supply | Internal Rechargeable Li-ion Battery (PMM 3030-2), AC Adapter |
| Compliance | IEC 61000-4-3, IEC 61000-4-6 |
| Sweep Mode | Yes |
| Programmable | Yes |
| Correction Table Support | Yes |
| Brand | LSI-LASTEM |
|---|---|
| Origin | Italy |
| Model | R-Log 7730 |
| Sensor Compliance | ISO 7726 |
| Calculated Indices | PMV/PPD, DR, PD, TO, Tr, Pa, TU, AD (Asymmetry Discomfort) |
Show next