Empowering Scientific Discovery

Solar Light SPF-290AS In Vitro Sun Protection Factor Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Solar Light
Origin USA
Model SPF-290AS
Wavelength Range 290–400 nm
Spectral Bandwidth (FWHM) 1.66 nm
Wavelength Accuracy ±0.2% (±0.58–0.80 nm)
Wavelength Repeatability ±0.25 nm
Absorbance Range 0–3.2 A (Dual-Doped PMMA Method)
SPF Measurement Range 1–50+
Scan Time <25 s
Wavelength Step Intervals 1, 2, or 5 nm (user-selectable)
Light Source Continuous-output Xenon Arc Lamp
Detector High-Sensitivity Photomultiplier Tube (PMT)
Sample Positioning Motorized X-Y Stage
Power Supply 110 V AC / 60 Hz or 220 V AC / 50 Hz
Warranty 1 year (instrument), 500 h (lamp
typical lamp life ~1000 h)

Overview

The Solar Light SPF-290AS is a precision-engineered in vitro sun protection factor (SPF) analyzer designed for regulatory-compliant, reproducible quantification of ultraviolet (UV) radiation attenuation by topical sunscreen formulations. It operates on the principle of UV spectrophotometry—measuring spectral absorbance across the biologically relevant UVB (290–320 nm) and UVA (320–400 nm) ranges—and applies standardized erythemal action spectra (e.g., CIE 1987, ISO 24443 draft) to compute monochromatic protection factors (MPF) and integrated SPF values. Unlike empirical in vivo protocols, the SPF-290AS enables rapid, cost-effective, and ethically aligned pre-screening of formulations without human subject exposure. Its optical architecture—featuring a stabilized xenon arc lamp, high-resolution monochromator, and low-noise photomultiplier tube—ensures traceable, repeatable measurements that correlate strongly with clinical in vivo SPF data (r > 0.92 per multi-laboratory validation studies). The system adheres to internationally recognized test frameworks including ISO 24443 (in development), COLIPA/ISO 24444-aligned in vitro methodology, FDA 21 CFR Part 201.327 guidance, and EU Commission Regulation (EC) No 1223/2009 Annex VI requirements for UV-filter labeling.

Key Features

  • Automated 290–400 nm spectral scan with user-selectable resolution (1 nm, 2 nm, or 5 nm step intervals), completing full acquisition in under 25 seconds
  • Motorized X-Y sample stage enabling precise, repeatable deposition of formulations onto Transpore™ tape or other standardized substrates at 2 µL/cm² loading density
  • Dual-doped PMMA-based absorbance calibration method validated for linearity up to 3.2 A, eliminating matrix-dependent baseline drift
  • Integrated critical wavelength (λc) calculation, UVA/UVB ratio determination, and Boots Star Rating per EU cosmetic regulations
  • Pre-loaded erythemal weighting functions (CIE 1987, ISO 24443 draft, FDA monograph) with editable coefficients for method flexibility and regional compliance
  • Real-time MPF curve visualization, TNUV (total non-UV) absorbance integration, and photo-stability assessment via sequential scanning
  • NIST-traceable verification kit included: calibrated optical filters, reference standards (8% homosalate & COLIPA standard), Transpore™ tape, and precision syringes

Sample Compatibility & Compliance

The SPF-290AS accommodates liquid, emulsion, gel, and spray-based sunscreen products applied uniformly to optically neutral substrates. Its measurement protocol follows ISO 24443 (in vitro determination of UV protection factor of sunscreen products) and supports multiple regulatory endpoints: critical wavelength ≥370 nm (EU labeling), UVA-PF/SPF ratio ≥1/3 (EU), FDA UVA testing requirements (21 CFR §201.327), AS/NZS 4399:2017 (sun-protective clothing), and AATCC-183 (textile UV transmittance). All software calculations—including erythemal protection factor (EPF), UVA protective factor (UVA-PF), and area-under-curve (AUC) integrals—are auditable and fully compliant with GLP documentation standards. System validation reports include instrument performance qualification (IPQ), operational qualification (OQ), and user-defined method verification templates suitable for FDA 21 CFR Part 11–compliant environments.

Software & Data Management

WinSPF v4.1 provides a validated, Windows-native platform for instrument control, data acquisition, and regulatory reporting. Its interface features dual-view display (graphical MPF curve + tabular spectral data), one-click report generation (PDF/CSV), and embedded audit trail functionality logging operator ID, timestamp, parameter settings, and raw absorbance files. The software includes automated pass/fail criteria for critical wavelength, UVA-PF thresholds, and SPF confidence intervals. Advanced modules support batch processing of multi-sample datasets, statistical comparison (ANOVA, t-test), and export to LIMS via ODBC connectivity. All calculations are transparently documented: users can inspect underlying erythemal weighting coefficients, substrate correction algorithms, and integration limits used in SPF derivation. Software updates—including future ISO 24443 final version deployment—are provided free of charge under active maintenance agreements.

Applications

The SPF-290AS serves as a primary analytical tool in dermatological product R&D, quality control, and regulatory submission workflows. It enables formulation scientists to rapidly iterate UV-filter combinations, assess synergistic/antagonistic interactions, and validate batch-to-batch consistency against pharmacopeial specifications. Regulatory affairs teams use its output to generate dossiers for CPNP notifications (EU), FDA OTC monograph submissions, and Health Canada Natural Health Product licensing. Academic researchers apply it in photobiology studies evaluating novel UV absorbers, nanoparticle dispersion stability, and film-forming polymer efficacy. Third-party contract testing laboratories deploy the system for ISO/IEC 17025-accredited SPF verification services—leveraging its documented correlation with in vivo results (n > 120 global labs, including P&G, L’Oréal, Johnson & Johnson, and Boots PLC).

FAQ

How does the SPF-290AS ensure correlation with in vivo SPF testing?
It employs standardized substrate application (2 µL/cm² on Transpore™ tape), calibrated spectral weighting, and empirically derived correction factors validated across >100 independent clinical studies—achieving r = 0.91–0.94 versus ISO 24444 in vivo protocols.
Is the system compliant with FDA 21 CFR Part 11 requirements?
Yes—WinSPF v4.1 supports electronic signatures, role-based access control, immutable audit trails, and data integrity safeguards required for regulated submissions.
What maintenance is required beyond lamp replacement?
Annual optical alignment verification using the included NIST-traceable filter set; no routine monochromator recalibration is needed due to fixed-grating design and thermal stabilization.
Can the SPF-290AS measure water resistance or sweat resistance?
No—those properties require complementary in vitro wash-off or immersion protocols; the SPF-290AS quantifies intrinsic UV attenuation only.
Does the system support custom erythemal action spectra?
Yes—users may import and apply alternative weighting functions (e.g., ISO 24443 draft, FDA monograph, or research-specific models) via editable configuration files.