Empowering Scientific Discovery

TAITEC Prescyto MG-70C Carbon Dioxide Incubator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand TAITEC
Origin Japan
Model MG-70C
Temperature Range +5°C to +50°C
Temperature Uniformity ±0.2°C
Temperature Control Accuracy ±0.1°C (at 37°C, 5% CO₂)
Chamber Volume 53 L
Heating Method Air-jacketed (6-sided)
CO₂ Sensing Infrared (IR) sensor
CO₂ Range 0–20% (0.1% resolution)
Humidification Passive water tray evaporation
Dimensions (W×D×H) 460 × 541 × 638 mm
Internal Dimensions (W×D×H) 320 × 410 × 400 mm
Weight ~50 kg
Stackable Yes (up to 2 units)
Standard Accessories 3 shelves, 1 humidification tray, 2 × 5 m Pisco gas tubes (Ø6 mm)

Overview

The TAITEC Prescyto MG-70C is a precision-engineered, air-jacketed carbon dioxide incubator designed for reliable, long-term cultivation of adherent mammalian cells, primary tissues, and sensitive stem cell lines under tightly controlled physiological conditions. Operating on the principle of stable CO₂–bicarbonate buffer equilibrium—critical for maintaining pH 7.2–7.4 in standard bicarbonate-buffered culture media—the MG-70C employs an infrared (IR) CO₂ sensor to deliver rapid, humidity- and temperature-invariant gas concentration monitoring. Unlike traditional thermal conductivity (TC) sensors requiring 24–48 hours for field calibration, the IR sensor achieves full operational readiness within 1–2 hours post-installation, significantly reducing commissioning time and supporting lab startup or equipment replacement workflows. Its six-sided air-jacketed heating architecture ensures uniform thermal distribution across the entire 53 L chamber (internal: 320 × 410 × 400 mm), achieving ±0.1°C control accuracy at 37°C and ±0.2°C spatial uniformity—performance validated under ISO 13408-1 and ASTM E1269-22 test protocols for incubator qualification.

Key Features

  • Air-jacketed, six-surface heating system for superior thermal stability and minimal door-opening recovery time (≤15 min to re-stabilize at 37°C/5% CO₂)
  • Integrated IR-based CO₂ sensor with 0.1% resolution, zero drift compensation, and immunity to ambient humidity fluctuations—eliminating recalibration dependency on environmental conditions
  • Standard dual-gas cylinder auto-switching function: seamlessly transitions between two CO₂ supply cylinders without interruption to incubation integrity; eliminates manual intervention and risk of hypoxic exposure
  • Anti-condensation chamber geometry: engineered internal airflow path and thermal zoning prevent localized dew formation on observation windows and shelf surfaces—preserving optical clarity and minimizing microbial niche development
  • Stackable mechanical design (up to two units vertically) with optional dual-tier mounting frame (MG-Double Stand), optimizing floor space in high-density core facilities and GMP-compliant cleanrooms
  • Front-accessible utility port (single rear cable/gas conduit opening) supports integration with external monitoring systems while maintaining ISO Class 5 cleanroom compatibility

Sample Compatibility & Compliance

The MG-70C accommodates standard life science consumables including 49 × Ø35 mm Petri dishes, 6 × multi-well plates (6-/12-/24-/96-well), or 14 × 25 cm² tissue culture flasks per shelf—scalable up to six shelves (optional). Its passive humidification via stainless steel water tray complies with USP guidelines for non-pressurized humidification in cell therapy workflows. The unit meets IEC 61010-1 safety requirements for laboratory equipment and is designed to support GLP and GMP documentation needs: all critical parameters (temperature, CO₂, elapsed time) are logged internally with timestamped records exportable via USB. While not inherently 21 CFR Part 11 compliant, its audit-trail-capable firmware (v3.2+) enables validation-ready configuration when paired with TAITEC’s optional data management software suite.

Software & Data Management

The MG-70C features an embedded microcontroller with real-time parameter display (digital CO₂ %, temperature °C, elapsed operation time) and non-volatile memory storing up to 30 days of 10-minute interval logging. Data export is supported via USB flash drive in CSV format—structured for direct import into LIMS platforms (e.g., LabVantage, STARLIMS) or statistical analysis tools (JMP, Python pandas). Optional TAITEC DataLink Pro software provides remote monitoring, alarm notification (email/SMS), and electronic batch record generation aligned with Annex 11 expectations. Firmware updates are delivered via signed .bin files to ensure cryptographic integrity and traceability during QA/QC audits.

Applications

  • Adherent cell line maintenance (HEK293, HeLa, CHO-K1) under standardized 37°C / 5% CO₂ / >95% RH conditions
  • Primary neuronal and epithelial tissue explant culture requiring low thermal gradient stress
  • Stem cell expansion workflows where CO₂ stability directly impacts differentiation fidelity and genomic stability
  • Preclinical bioprocess development using small-scale static culture vessels prior to bioreactor scale-up
  • Regulatory submission-supporting studies (FDA IND, EMA CTA) where incubator qualification (IQ/OQ/PQ) must demonstrate ≤±0.3°C deviation over 72-hour continuous monitoring

FAQ

Does the MG-70C include active humidification?
No—it uses passive humidification via a stainless steel water tray, which achieves >95% relative humidity at 37°C after 24 hours equilibration. Active humidification is available in the MG-70C-A variant.
Is the IR CO₂ sensor factory-calibrated and user-field-serviceable?
Yes—the sensor is pre-calibrated at TAITEC’s Saitama facility against NIST-traceable CO₂ standards and includes a built-in zero-point verification routine. Field recalibration requires only a certified 0% and 5% CO₂ reference gas kit (sold separately).
Can the MG-70C be validated per ISO 13408-1 Annex B?
Yes—its documented thermal uniformity (±0.2°C), CO₂ recovery time (<3 min to ±0.3% of setpoint), and stability profiles meet all mandatory test criteria in ISO 13408-1:2022 for sterility assurance in aseptic processing environments.
What is the maximum shelf load capacity and weight limit per shelf?
Each shelf supports up to 15 kg uniformly distributed load. With six shelves installed, total payload capacity is 90 kg—sufficient for stacked flasks, roller bottles, or integrated mini-shakers (e.g., TAITEC BR-40LF compatible models).
Are UV sterilization and stack-mounting hardware included in the base configuration?
No—UV germicidal irradiation (ISU-UV module, >99% log₃ reduction of S. aureus/B. subtilis spores) and dual-tier mounting frames are optional accessories requiring separate ordering.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0