| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 72,800 (FOB) |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368 |
| Measurement Range | 0.1–1.0 µm (standard), customizable 1–100 µm or 4–70 µm(c), down to 0.1 µm(c) |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output,超标 alarm relay (customizable) |
| Data Output | iPad-compatible wireless acquisition, touchscreen GUI + optional PC software (V8.3 Integrated Edition) |
| Power Supply | 100–265 VAC, 50–60 Hz |
| Compliance Architecture | Separated analytical testing & metrological calibration modules |
| Regulatory Alignment | Supports FDA 21 CFR Part 11 audit trail configuration (via optional software license), GLP/GMP-compliant reporting templates |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 |
| Sensor Technology | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Detection Range | 0.03–3000 µm (configurable sub-ranges: 1–100 µm, 4–70 µm(c), or 0.1 µm(c)) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501-2, NIST-traceable latex spheres |
| Output | 4–20 mA analog interface with customizable alarm thresholds |
| Data Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Analysis & Calibration Suite (PC + integrated touchscreen UI) |
| Compliance | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Model | TQ-01A |
| Application | Pharmaceutical Dissolution Media Deaeration |
| Display | High-Resolution Touchscreen LCD |
| Heating Range | 35–42 °C (adjustable to non-heating mode) |
| Volume Accuracy | ±1% (for set volumes ≥2 L) |
| Dispensing Resolution | 0.1 L |
| Flow Rate | 1.6 L/min |
| Dimensions (L×H×W) | 500 mm × 340 mm × 295 mm |
| Rated Power | 1700 W |
| Temperature Control Accuracy | ±2 °C |
| Residual Dissolved Oxygen | 3.0–5.0 mg/L (upgradable to <2.8 mg/L) |
| Minimum Inlet Medium Temperature | ≥18 °C |
| Pre-Filter Options | 40 µm / 25 µm / 20 µm Stainless Steel Mesh |
| Compatible Media | Purified water, distilled water (pH 1–14, surfactant-free) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Calibration Standards | ISO 11171, ISO 4402, GB/T 18854 |
| Measurement Range | 1–1000 µm (sensor-dependent) |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171/GB/T 18854) |
| Channel Resolution | Up to 1000 user-configurable size channels |
| Sample Volume Accuracy | ±1% |
| Flow Rate | 5–60 mL/min (sampling), 10–100 mL/min (cleaning) |
| Viscosity Limit | ≤450 mm²/s |
| Operating Temperature | Ambient to 65 °C |
| Pressure Range | –0.08 to 0.8 MPa |
| Power Supply | 220 V, 50 Hz, <80 W |
| Data Storage | 3000 tests onboard |
| Compliance | DL/T 1096, GJB 420B, NAS 1638, ISO 4406, MOOG, ISO 11218, DL/T 432, ISO 11500 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601 |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Laser Source | Dual-narrow-beam laser diode array (8th-generation) |
| Sensor Resolution | 1000 channels, down to 0.01 µm |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Sample Volume Accuracy | < ±1% |
| Counting Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Channel Flexibility | User-definable size bins (e.g., 4–70 µm(c), 1–100 µm, or 0.1 µm(c)) |
| Flow Rate Range | Sample: 5–150 mL/min |
| Rinse | 5–500 mL/min |
| Fluid Temperature Range | 0–80 °C |
| Ambient Operating Range | −15–50 °C |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9–2013, YBB00272004–2015, GB 8368 |
| Software | V8.9 Analytical Suite (PC & embedded touchscreen), FDA 21 CFR Part 11 compliant (audit trail, electronic signature, role-based 5-level access, data backup/restore, power-fail recovery) |
| Calibration Standards | NIST-traceable polystyrene latex (PSL) spheres, JJG 1061–2019, ISO 21501-4 |
| Brand | PULUODY |
|---|---|
| Model | PMT-2PB |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Measurement Range | 0.1–0.5 µm & 0.5–20.0 µm (customizable to 1–100 µm or 4–70 µm(c) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog signal with configurable particle-exceedance alarm |
| Data Interface | iPad-compatible wireless data acquisition system |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen version) |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex sphere reference |
| Compliance | Supports GLP/GMP audit trails, FDA 21 CFR Part 11–ready software architecture (user authentication, electronic signatures, change control logs) |
| Display & Control | 7-inch color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Application Scope | Semiconductor cleaning fluids, ultrapure water (UPW), photomasks, silicon wafers, flat-panel display substrates, PCB etchants & rinsates, nano/microfiltration effluents, polymer solutions, and insoluble particulate analysis in organic solvents |
| Brand | PULL |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Pull-GP4-1000 |
| Capacity | 1 L |
| Material | Stainless Steel (AISI 316 or equivalent) |
| Design Pressure | 4 MPa |
| Compliance | GB 8570–2008 “Sampling of Laboratory Samples of Anhydrous Liquid Ammonia” |
| Pricing | USD 450 (FOB China, subject to quotation) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-0203-3 |
| Price | USD 27,800 (approx.) |
| Compliance | ISO 4406, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Calibration Standards | JJG 1061, ISO 11171, ASTM F658-87 (PSL), GB/T 18854 |
| Detection Principle | Light Obscuration (LO) |
| Laser Source | 7th-generation dual-laser narrow-beam sensor |
| Measurement Range | 0.03 µm – 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 resolution channels |
| Sensitivity | 1 µm (ISO 4402) / 4 µm(c) (ISO 11171, GB/T 18854) |
| Accuracy | < ±3% |
| Sample Volume Precision | ±1% |
| Max. Online Pressure | 31.5 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Flow Rate | Sampling 5–60 mL/min |
| Operating Temp. | Sample 20–65°C |
| Power | 220 VAC, 50 Hz, <80 W |
| Data Storage | Up to 6000 test records |
| Output Interfaces | RS232, RS485, USB, 4–20 mA, 0–5 V, MODBUS |
| Regulatory Certification | CALIBRATED by NW National Metrology Center (civil) or CMC Level-1 Particle Metrology Station (defense) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PLD-269C |
| Pricing | Available Upon Request |
| Maximum Penetration Range | 75 mm |
| Penetration Resolution | ±0.1 mm |
| Timing Accuracy | 0.1 s |
| Standard Cone | Compliant with GB/T 269 |
| Brand | PULUODY |
|---|---|
| Model | PMT-2CCS |
| Detection Threshold | 100 nm |
| Sensor Technology | 8th-Generation Dual-Laser Narrow-Beam Optical Sensor |
| Measurement Range | 0.1–0.5 µm (with customizable ranges: 1–100 µm or 4–70 µm(c), down to 0.1 µm(c)) |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Calibration Standards | JJG 1061, ISO 21501, Polystyrene Latex (PSL) Spheres |
| Output Interface | 4–20 mA Analog Signal |
| Alarm Function | Configurable Particle Exceedance Alert |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for ISO 14644-1/2, SEMI F57, ASTM D6978, USP <788> & <789>, and GLP/GMP-aligned data integrity workflows |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | PLD-508A |
| Heating Power | 4000 W |
| Rated Voltage | AC 220 V / 50 Hz |
| Furnace Chamber Dimensions | 300 × 200 × 120 mm |
| Filter Paper Diameter | 9 cm |
| Porcelain Crucible Capacity | 50 mL |
| Temperature Range | Ambient to 1000 °C |
| Control System | Analog Pointer-Based Temperature Controller with Integrated Ammeter |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601J |
| Instrument Type | Optical Light-Blockage Particle Counter |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Particle Sensor |
| Flow Control | Precision Metering Plunger Pump + Ultra-Precise Electromagnetic Flow Control System |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail, Electronic Signature, Role-Based 5-Tier User Access |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-Traceable Latex Spheres |
| Channel Resolution | 1000 Adjustable Channels (Down to 0.01 µm), Configurable Size Ranges (e.g., 1–100 µm, 4–70 µm(c), 0.1 µm(c)) |
| Measurement Range | 1–450 µm (Extended Options: 0.03–3000 µm) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Ambient Operating Range | −15–50 °C |
| Accuracy | ±5% typical (per ChP 2020 & USP <788>) |
| Repeatability | <2.5% coincidence error at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), >90% (ISO 21501-4 calibrated) |
| Regulatory Alignment | ChP 0903 (2015/2020), USP <788>, <789>, <797>, EP 10.0, BP 2019, JP 17, WHO IntPh IV, YBB00272004-2015, GB 8368, ISO 21510, ISO 11171, NAS 1638, ISO 4406 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | PQ-2A |
| Price | USD 64,500 (FOB China) |
| Brand | PULUODY |
|---|---|
| Model | PLD-601Q |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) / Dual-Laser Narrow-Beam Sensor |
| Measurement Range | 1–450 µm (optional extension to 0.03–3000 µm) |
| Channel Resolution | 1000 adjustable channels (down to 0.01 µm bin width) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Accuracy | ±5% typical (per USP <788>, ISO 21501-4, ChP 2020) |
| Coincidence Limit | ≤5% at 1000 particles/mL |
| Temperature Range (Fluid) | 0–80 °C |
| Compliance | FDA 21 CFR Part 11, GMP/GLP audit trail, USP <788>/<789>, EP 10.0, ChP 0903, GB/T 11446.9–2013, GB 8368, ISO 21501-4, ISO 11171, NAS 1638 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601* |
| Sensor | 8th-generation dual-laser narrow-beam particle sensor |
| Detection Principle | Light Blockage (Optical Obstruction) |
| Measurement Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 adjustable channels (down to 0.01 µm resolution) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), <10% (USP/ISO 21501-calibrated) |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9-2013, GB 8368, YBB 00272004-2015 |
| Software | V8.9 Regulatory Edition with 5-level user permissions, audit trail, electronic signature, 21 CFR Part 11 compliance, data backup/recovery, and power-fail protection |
| Interface | Touchscreen + optional wireless keyboard/mouse |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, or ISO 21501-4 reference materials |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-3535D |
| Temperature Range | 60 °C to −38 °C |
| Temperature Resolution | 0.1 °C |
| Sample Channels | 2 |
| Cooling Method | Air-Cooled Compressor System |
| Detection Method | Top-Mounted Photoelectric Liquid-Level Sensor with Micro-Tilt Mechanism |
| Temperature Interval Setting | 1–10 °C (user-defined) |
| Power Supply | AC 220 V ±10%, 50 Hz ±2 Hz |
| Display | 128×64 Dot-Matrix LCD (Chinese Characters) |
| Printer | 20-Column Dot-Matrix Thermal Printer (Chinese Characters) |
| Compliance Standard | GB/T 510 |
Show next