Rheometer
Filter
Showing 61–90 of 91 results
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | JOS06 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Interfacial Rheometer |
| Bearing Type | Mechanical Bearings |
| Minimum Rotational Speed | 10⁻⁴ rpm |
| Frequency Range | 10⁻³–628 rad/s |
| Maximum Rotational Speed | 3000 rpm |
| Maximum Torque | 200 mN·m |
| Torque Resolution | < 100 nN·m |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±1 °C (±0.1 °C within 100 °C) |
| Quartz Plate Spacing | 0.05–2 mm |
| Sample Area | Ø25 mm |
| Optical Resolution | 25 pixels/µm |
| Oscillation Frequency Range | 0.01–10 Hz |
| Steady-State Shear Rate Range | 0.001–500 rpm (controlled to ±0.01 rpm at low end) |
| Observation Port | Wide-field transmission & polarized light path |
| CCD System | Color, 3-axis motorized positioning |
| Objective Working Distance | 7 mm |
| Top & Bottom Quartz Plates | Independently motorized, heated via integrated heating plates, temperature monitored by Pt100 sensors |
| Removable Cover & Optional Quartz Plate Sets | Supported for rapid sample exchange and contamination control |
| Origin | USA |
|---|---|
| Manufacturer | Kaltec (USA) |
| Instrument Type | Rotational Rheometer |
| Max Shear Rate | 1–1.38×10⁵ s⁻¹ (standard), up to 1.85×10⁵ s⁻¹ (upgraded) |
| Torque Range | 1.0×10⁴–1.8×10⁷ dyn·cm |
| Shear Stress Range | 80–6.0×10⁵ dyn/cm² |
| Recommended Viscosity Range | 1–4.5×10³ cP (10⁻² P) |
| Weight | 62 kg |
| Dimensions (H×W×D) | 81×64×46 cm |
| Brand | KSV NIMA |
|---|---|
| Origin | Finland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | KSV NIMA ISR Flip |
| Instrument Type | Interfacial Rheometer |
| Sample Viscosity Range | Low-viscosity liquids |
| Sample State | Liquid |
| Bearing Type | Mechanical bearing |
| Frequency Range | 0.01–10 Hz |
| Torque Resolution | 0.001 mN·m |
| Brand | LS Instruments |
|---|---|
| Origin | Switzerland |
| Model | DWS RheoLab |
| Temperature Range | 5°C–100°C |
| Frequency Range | 0.1 Hz–10 MHz |
| Minimum Measurable Frequency | 0.1 Hz |
| Maximum Measurable Frequency | 10⁷ Hz |
| Sample Volume Requirement | ≥150 µL |
| Sample State | Liquid |
| Measurement Principle | Diffusing Wave Spectroscopy (DWS) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software Platform | LS Instruments RheoSoft v5.x |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MLW-400 |
| Quotation | Available upon Request |
| Temperature Range | Ambient to 400 °C ±1 °C |
| Heating Rate | 1–6 °C/min (adjustable in 0.1 °C/min increments) |
| Temperature Accuracy | <±0.5 °C (displayed by PC), Resolution: 0.1 °C |
| Piston Diameter | φ11.28 mm (tolerance: –0.012 mm to –0.05 mm) |
| Piston Cross-sectional Area | 1 cm² |
| Pressure Range | 1–50 MPa ±1% |
| Die Configurations | Φ1×5, Φ1×10, Φ1×20, Φ1×40 mm (diameter × length) |
| Die Material | Tungsten Carbide |
| Power Supply | 220 V AC, 50 Hz, <400 W |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus DSR |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Angular Velocity | 10 nrad/s |
| Maximum Angular Velocity | 325 rad/s |
| Frequency Range | 1 µHz – 100 Hz |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.001 N – 50 N |
| Normal Force Response Time | <10 ms |
| Vertical Travel Speed | 0.1 µm/s – 35 mm/s |
| Vertical Travel Distance | 230 mm |
| Gap Resolution | 0.1 µm |
| Motor Inertia | 12 µN·m·s² |
| Torque Range (Rate/Stress Control) | 0.01 µNm – 200 mNm |
| Torque Range (Strain/Stress Control) | 0.05 µNm – 200 mNm |
| Fixture Identification | RFID-enabled Smart Recognition |
| Environmental Control Unit | Plug-and-Play with Auto-Detection |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus DSR-III |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Angular Velocity | 10 nrad/s |
| Maximum Angular Velocity | 200 rad/s |
| Frequency Range | 1 µHz – 100 Hz |
| Maximum Torque | 150 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.01 N – 20 N |
| Normal Force Response Time | <10 ms |
| Vertical Travel Speed | 0.1 µm/s – 20 mm/s |
| Vertical Travel Distance | 230 mm |
| Gap Resolution | 0.1 µm |
| Motor Inertia | 12 µN·m·s² |
| Torque Range (Rate/Stress Control) | 0.1 µNm – 150 mNm |
| Torque Range (Strain/Stress Control) | 0.1 µNm – 150 mNm |
| Fixture Identification | RFID-enabled Smart Recognition |
| Environmental Control Unit | Plug-and-Play with Auto-Detection |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus DSR+ |
| Instrument Type | Rotational Rheometer |
| Sample State | Liquid |
| Bearing Type | Air Bearing |
| Minimum Angular Velocity | 1 nrad/s |
| Maximum Angular Velocity | 500 rad/s |
| Frequency Range | 1 µHz – 150 Hz |
| Maximum Torque | 225 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.001 N – 50 N |
| Normal Force Response Time | <10 ms |
| Vertical Travel Speed | 0.1 µm/s – 35 mm/s |
| Vertical Travel Distance | 230 mm |
| Gap Resolution | 0.1 µm |
| Motor Inertia | 12 µN·m·s² |
| Control Modes | Rate, Stress, Strain |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus lab+ |
| Instrument Type | Rotational Rheometer |
| Sample State | Liquid |
| Bearing Type | Air Bearing |
| Minimum Angular Velocity | 10 nrad/s |
| Maximum Angular Velocity | 325 rad/s |
| Frequency Range | 1 µHz – 150 Hz |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.001 N – 50 N |
| Normal Force Response Time | 10 ms |
| Vertical Travel Speed | 0.1 µm/s – 35 mm/s |
| Vertical Travel Distance | 230 mm |
| Gap Resolution | 0.1 µm |
| Motor Inertia | 12 µN·m·s² |
| Torque Range (Steady-State) | 0.01 µNm – 200 mNm |
| Torque Range (Oscillatory) | 0.005 µNm – 200 mNm |
| Fixture Identification | RFID-enabled Smart Recognition |
| Environmental Control Unit | Plug-and-Play with Auto-Detection |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus Prime Ultra+ |
| Instrument Type | Rotational Rheometer |
| Frequency Range | 1 µHz to 150 Hz |
| Temperature Control | Modular EasySwap™ Environmental Units |
| Normal Force Control | High-Sensitivity Electromagnetic Sensor |
| Vertical Travel & Gap Control | Precision Motorized Actuation |
| Compliance | ASTM D3835, ISO 6721-10, ISO 3219, USP <911>, FDA 21 CFR Part 11 (Software Mode), GLP/GMP Audit Trail Capable |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus pro+ |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Angular Velocity | 1 nrad/s |
| Maximum Angular Velocity | 500 rad/s |
| Frequency Range | 1 µHz – 150 Hz |
| Maximum Torque | 225 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.001 N – 50 N |
| Normal Force Response Time | <10 ms |
| Vertical Travel Speed | 0.1 µm/s – 35 mm/s |
| Vertical Travel Distance | 230 mm |
| Gap Resolution | 0.1 µm |
| Motor Inertia | 12 µN·m·s² |
| Torque Range (Steady-State) | 0.005 µNm – 225 mNm |
| Torque Range (Oscillatory) | 0.001 µNm – 225 mNm |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus Rosand RH10 |
| Instrument Type | Capillary Rheometer |
| Sample State | Liquid |
| Minimum Extrusion Speed | 5 µm/min |
| Maximum Extrusion Speed | 1200 mm/min |
| Maximum Load | 100 kN |
| Die Diameter Range | 0.5–3 mm |
| Barrel Diameter (Standard) | 15 mm (Optional: 9.5, 12, 19, 24 mm) |
| Barrel Material | Nitrided Steel (Optional: Stainless Steel or Hastelloy) |
| Die Material | Tungsten Carbide |
| Speed Dynamic Range | 240,000:1 |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus Rosand RH2000 |
| Instrument Type | Capillary Rheometer |
| Sample State | Liquid |
| Minimum Piston Speed | 10 µm/min |
| Maximum Piston Speed | 1200 mm/min |
| Maximum Load | 20 kN |
| Die Diameter Range | 0.5–3 mm |
| Barrel Diameter | 15 mm (standard), optional 9.5 / 12 / 19 / 24 mm |
| Barrel Material | Nitrided Steel (optional stainless steel or Hastelloy) |
| Die Material | Tungsten Carbide |
| Speed Dynamic Range | 240,000:1 |
| Compliance | ASTM D3835, ISO 11443, ISO 6721-6, USP <911> |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | Kinexus Rosand RH7 |
| Instrument Type | Capillary Rheometer |
| Minimum Extrusion Speed | 2.5 µm/min |
| Maximum Extrusion Speed | 600 mm/min |
| Maximum Load Capacity | 50 kN |
| Speed Dynamic Range | 240,000:1 |
| Standard Barrel Diameter | 15 mm (optional: 9.5, 12, 19, 24 mm) |
| Barrel Material | Nitrided Steel (optional: Stainless Steel or Hastelloy) |
| Die Material | Tungsten Carbide |
| Die Diameter Range | 0.5–3 mm |
| Optional Accessories | Nitrogen Purge System, Melt Strength Tester, Melt Draw-Down Fixture, Laser-Based Die Swell Measurement, Slit Dies, PVT Measurement Dies, Melt Cut-Off Knife |
| Brand | RHEO FILAMENT |
|---|---|
| Origin | Denmark |
| Model | VADER 1000 |
| Instrument Type | Filament Stretching Rheometer |
| Bearing Type | Mechanical |
| Minimum Axial Speed | 0.001 mm/s |
| Maximum Axial Speed | 600 mm/s |
| Max Hencky Strain | 9 |
| Min Strain Rate | 0.0001 s⁻¹ |
| Max Strain Rate | 5 s⁻¹ |
| Min Measurable Stress | 15 Pa |
| Max Measurable Stress | 1×10¹⁰ Pa |
| Sample Diameter Range | 0.1–10 mm |
| Temperature Range | Ambient to 250 °C (±0.1 °C) |
| Optional Convection Oven Flow Rate | 5 L/min |
| Recommended Minimum Sample Viscosity | 1000 Pa·s |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CFT-EX Series |
| Instrument Type | Capillary Rheometer |
| Temperature Range | 20–400 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Displacement Range | 15 mm |
| Displacement Resolution | 0.01 mm |
| Sample Volume | Up to 1.5 cm³ |
| Viscosity Measurement Range | 1×10¹–1×10⁶ Pa·s (CFT-500EX) |
| Heating Method | Resistive Wire Heating |
| Loading Method | Dead-Weight Piston Drive |
| Test Modes | Isothermal and Temperature-Ramp (Rheological Softening Point) |
| Brand | SINTERFACE |
|---|---|
| Origin | Germany |
| Model | ISR-1 |
| Interface Shear Viscosity Range | 1 µN·s/m to 100 mN·s/m |
| Interface Shear Elasticity Range | 1 µPa·m to 100 mPa·m |
| Frequency Range | 0.02–0.2 Hz |
| Torsion Angle Resolution | 0.01° |
| Position Sensor Angular Resolution | 0.01° |
| Temperature Control Range | 10–50 °C |
| Dimensions (L×W×H) | 500 × 500 × 700 mm |
| Weight | 50 kg |
| Power Supply | 100–240 V AC, 50–60 Hz, 110 W |
| Data Interface | RS-232 |
| DAQ Hardware | National Instruments high-fidelity I/O board |
| Operating System | Windows-compatible software |
| Sample Interfaces | Air/liquid and liquid/liquid interfaces |
| Optional Accessory | Liquid/liquid interface trough |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | RSX-CC |
| Pricing | Available Upon Request |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | ARES-G2 |
| Instrument Type | Rotational Rheometer |
| Sample Type | High-Viscosity & Solid-State Materials |
| Motor Bearing | Sapphire Air Bearing |
| Temperature Range | −40 °C to 180 °C |
| Minimum Rotational Speed | 0 rpm |
| Frequency Range | 1 × 10⁻⁷ to 628 rad/s |
| Maximum Torque | 200 mN·m |
| Torque Resolution | 1 nN·m |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Precision Air Bearing |
| Temperature Range | -10 to 200 °C |
| Frequency Range | 10⁻⁴ to 628 rad/s |
| Minimum Angular Velocity | 10⁻⁴ rad/s |
| Maximum Angular Velocity | 300 rad/s |
| Maximum Torque | 125 mN·m |
| Torque Resolution | 10 nN·m |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Discovery HR 30 |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Magnetic Levitation Thrust Bearing |
| Temperature Range | −40 to 200 °C |
| Frequency Range | 1.0 × 10⁻⁷ to 100 Hz |
| Minimum Angular Velocity | 0 rad/s |
| Maximum Torque | 200 mN·m |
| Maximum Angular Velocity | 300 rad/s |
| Torque Resolution | 0.05 nN·m |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Discovery Hybrid Rheometer HR 10 |
| Instrument Type | Rotational Rheometer |
| Thrust Bearing | Magnetic Levitation Thrust Bearing |
| Temperature Range | −40 to 200 °C |
| Frequency Range | 1.0 × 10⁻⁷ to 100 Hz |
| Minimum Angular Velocity | 0 rad/s |
| Maximum Torque | 200 mN·m |
| Maximum Angular Velocity | 300 rad/s |
| Torque Resolution | 0.1 nN·m |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Discovery Hybrid Rheometer HR 20 |
| Instrument Type | Rotational Rheometer |
| Thrust Bearing | Magnetic Levitation Thrust Bearing |
| Temperature Range | −40 to 200 °C |
| Frequency Range | 1.0 × 10⁻⁷ to 100 Hz |
| Minimum Angular Velocity | 0 rad/s |
| Maximum Torque | 200 mN·m |
| Maximum Angular Velocity | 300 rad/s |
| Torque Resolution | 0.1 nN·m |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 1×10⁻⁸ rpm |
| Frequency Range | 1×10⁻⁶ – 100 Hz |
| Maximum Rotational Speed | 4500 rpm |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Angular Displacement Resolution | 12 nrad |
| Normal Force Range | 0.01 – 50 N |
| Normal Force Resolution | 0.001 N |
| Vertical Travel | 240 mm |
| Gap Resolution | 0.5 µm |
| Minimum Vertical Speed | 0.02 µm/s |
| Maximum Vertical Speed | 20 mm/s |
| Temperature Range (with optional modules) | −150 °C to +600 °C |
| Dimensions (W×D×H) | 600 × 600 × 890 mm |
| Weight | 59 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Torque Rheometer |
| Model | PolyLab OS |
| Motor Bearing | Screw-driven |
| Minimum Speed | 1 rpm |
| Frequency Range | 0.1–115 rad/s |
| Maximum Speed | 250 rpm (up to 1100 rpm optional) |
| Maximum Torque | 120 mNm (dual-range: 120/400 Nm) |
| Torque Resolution | 0.01 / 0.1 Nm |
| Temperature Range | Up to 400 °C (optional 450–500 °C) |
| Heating/Cooling | Electric heating + compressed air cooling |
| Control Zones | 7–10 independent temperature zones |
| Pressure Capability | Up to 700 bar |
| Barrel Design | Modular, horizontally split |
| Screw Configurations | Single-screw (Ø19.05 mm), Conical counter-rotating twin-screw (Ø31.8/20 mm), Parallel co-rotating twin-screw (Ø16/24 mm), Banbury-type mixer (120/625 cm³ chamber volume) |
| Power Supply | 7 kW / 16 kW |
| L/D Ratios | 10:1, 25:1, 33:1 (single-screw) |
| 25 | 1 to 40:1 (twin-screw) |
| Extrusion Capacity | ~5 kg/h (polymer-dependent) |
| Compliance | DIN 1.4301 stainless steel (mixer), DIN 1.8550 nitrided steel (screws/barrels) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | PolyLab QC |
| Instrument Category | Torque Rheometer |
| Drive Bearing | Single-screw configuration |
| Minimum Speed | 1 rpm |
| Frequency Range | 1–21 rad/s |
| Maximum Speed | 200 rpm |
| Maximum Torque | 300 N·m |
| Torque Resolution | 0.1 N·m |
| Torque Accuracy | ±0.15% of full scale |
| Temperature Range | Up to 450 °C (heating via electric cartridge heaters |
| Screw Material | Nitrided stainless steel (DIN 1.8550) |
| Chamber Material | Stainless steel (DIN 1.4301) |
| Mixer Chamber Volume | 120 cm³ or 625 cm³ |
| Screw Diameter | 19.05 mm (single-screw unit) / 31.8 mm & 20 mm (conical counter-rotating twin-screw unit) |
| Screw L/D Ratio | 25 |
| Screw Length | 300 mm |
| Gear Ratio | 3:2 |
| Maximum System Pressure | 700 bar |
| Power Rating | 4 kW |
| Control Interface | USB or optional Ethernet (LAN) |
| Software Platform | HAAKE PolySoft v7.x (Windows-based) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Rotational Rheometer |
| Motor Bearing | Air-bearing-free (direct-drive torque sensor) |
| Minimum Angular Velocity | 0.001 rad/s |
| Maximum Angular Velocity | 157 rad/s (≈1500 rpm) |
| Torque Range | 0.2–100 mN·m |
| Torque Resolution | 0.002 mN·m (0.2% of full scale) |
| Oscillation Frequency Range | 0.01–100 Hz (with optional oscillatory module) |
| Temperature Control | Peltier-based, -10 to +130 °C (with coaxial cylinder or cone/plate geometry) |
| Geometry Auto-Recognition | Yes |
| Interface | 7″ capacitive touchscreen + USB host/device + Ethernet |
| Software | HAAKE RheoApp (standalone on USB drive) and HAAKE RheoWin (PC-based, GLP-compliant) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | MARS iQ |
| Instrument Category | Rotational Rheometer |
| Bearing Type | Mechanical Ball Bearing |
| Minimum Rotational Speed | 0.01 rpm |
| Maximum Rotational Speed | 2000 rpm |
| Frequency Range | 0.01–20 Hz |
| Maximum Torque | 125 mN·m |
| Torque Resolution | 2.0 µN·m |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Rotational Rheometer Coupling Module |
| Model | Rheonaut |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 1 × 10⁻⁸ rpm |
| Frequency Range | 10⁻⁶ – 100 Hz |
| Maximum Rotational Speed | 4500 rpm |
| Maximum Torque | 200 mN·m |
| Torque Resolution | 0.1 nN·m |
| ATR Crystal Material | Diamond (Single-Reflection) |
| Temperature Control Options | Peltier (0–120 °C) or Electric Heating (RT–400 °C) |
| Detector | DTGS |
| Polarization Options | Manual/Automatic Dual-Axis Polarizers |
| Compliance | ASTM D3835, ISO 6721-10, USP <1043>, GLP/GMP-ready data audit trail support |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | Thermo Scientific Materials Characterization |
| Instrument Type | Torque Rheometer |
| Motor Bearing | Not Applicable |
| Minimum Rotational Speed | Not Specified |
| Maximum Rotational Speed | Not Specified |
| Frequency Range | Not Specified |
| Maximum Torque | Not Specified |
| Torque Resolution | Not Specified |