| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | 6 Maxi-BMP |
| Sensor Type | Electronic Pressure Transducer (Mercury-Free) |
| Pressure Range | 500–2000 hPa |
| Display | 4-digit LED |
| Interface | Dual-button Control |
| Output Units | NmL CH₄/g SV and mbar |
| Test Vessel Capacity | 1000 mL |
| Max. Sensors per Databox™ | 48 |
| Data Acquisition Interval | 2 h to 48 h |
| Test Duration | 10–60 days |
| Enclosure Rating | IP54 (per EN 60529) |
| Safety Compliance | IEC/EN 61010-1 |
| Connectivity | USB (RESPIROSoft™) or Optional Wi-Fi (Ermes™ Cloud Platform) |
| Power | Rechargeable Battery (Long Standby) |
| Optional Module | Ermes™ Remote Monitoring & Alert System |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | Respirometric Sensor System 6 |
| Pressure Range | 500–2000 hPa |
| Sensor Count | 6 |
| Test Vessel Capacity | 1000 mL |
| Data Acquisition Interval | 10 min – 48 h |
| Test Duration | 1–180 days |
| Stirrer Speed Control | 6-digit digital setting with lock function |
| Sensor Power | 2 W |
| Battery Type | CR2430 |
| Sensor Dimensions | 50 × 70 × 70 mm |
| Sensor Weight | 80 g |
| Stirrer Unit Dimensions | 230 × 51.5 × 370 mm |
| Stirrer Unit Weight | 1.75 kg |
| Ingress Protection | IP54 (EN 60529) |
| Safety Compliance | IEC/EN 61010-1 |
| Databox™ Capacity | up to 48 sensors (8 systems × 6 sensors) |
| Connectivity | USB (RESPIROSoft™) or optional Wi-Fi (Ermes™ Cloud Platform) |
| Software | RESPIROSoft™ v5.x with audit trail, method templates, report generation, and battery-level monitoring |
| Brand | Not specified |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YK100100 |
| Pricing | Upon Request |
| Length × Diameter | 36 in (914 mm) × 10 in (254 mm) |
| Mass | 100 oz (3.11 kg) |
| Max Calibrated Equivalent Airspeed | 0.9 Mach |
| Heating | Optional (Static/Total Pressure Ports Unheated by Default) |
| Compliance | RVSM (Reduced Vertical Separation Minimum) Static Source Error Calibration Requirements |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YK100400 |
| Pricing | Upon Request |
| Dimensions (L × Ø) | 30 in (762 mm) × 3 in (76 mm) |
| Mass | 6 oz (170 g) |
| Max Calibrated Equivalent Airspeed | ≥340 kt |
| Output Signals | Total Pressure, Static Pressure, Angle of Attack (AOA), Angle of Sideslip (AOS) |
| Heating Option | Optional Total/Static Pressure Ports |
| Typical Platform Class | UAVs, RC Aircraft, Light-Sport Aircraft (LSA), Research Vehicles, Automotive Aerodynamics Test Rigs, Railway Boundary Layer Studies |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | AccuStar |
| Output Options | Analog (0–5 V, 0–10 V, ±5 V), Ratiometric, Digital (PWM), Serial (RS-232/RS-485) |
| Full Scale Range | ±60° |
| Linear Range | ±45° |
| Resolution | 0.001° |
| Accuracy (0–10°) | ±0.1° |
| Accuracy (10–45°) | ±1% of reading |
| Zero Repeatability | 0.05° |
| Cross-Axis Sensitivity | <1% (within ±45°) |
| Time Constant | 0.3 s |
| Frequency Response (−3 dB) | 0.5 Hz |
| RF Immunity | <±2° |
| Operating Temperature | −30°C to +65°C |
| Storage Temperature | −55°C to +65°C |
| Zero Tempco | 0.008°/°C |
| Scale Factor Tempco | 0.1%/°C |
| EMC Compliance | EN 55022 Class B, IEC 61000-4-2 Level 2 (ESD), IEC 61000-4-3 Level 3 (10 V/m), IEC 61000-4-4 Level 3 (2 kV), MIL-STD-461D CS114 |
| Enclosure | Robust plastic housing, Ø2 in, Weight: 2 oz |
| Certifications | CE |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer | York Instrument |
| Type | DP-45 |
| Measurement Range | ±45° |
| Resolution | ±0.1° |
| Linearity | ±0.1° (0–10°), ±1.5% of reading (10–45°) |
| Repeatability | ±0.1° |
| Sensitivity Axis Error | <1% at tilt angles <45° |
| Power Supply | 9 V alkaline battery |
| Battery Life | ~100 hours |
| Operating Temperature | 0–65°C |
| Storage Temperature | −40–65°C |
| Weight | 349 g (12.3 oz) |
| Housing | Compact molded plastic enclosure |
| Reference Mode | Adjustable zero (floating reference) |
| Hold Function | Yes |
| Low-Battery Indication | LO BAT display at <7 V |
| Over-Range Indication | Flashing “OVER RANGE” beyond ±45° |
| Sign Convention | Minus sign (−) indicates counterclockwise deviation from reference |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DataNet |
| Price | Upon Request |
| ADC Resolution | 16-bit |
| Input Channels | 4 analog/digital inputs per node |
| Wireless Protocol | Zigbee (IEEE 802.15.4) @ 2.4 GHz |
| Max RF Range (LoS) | 80 m (extendable to 800 m with repeaters) |
| Network Capacity | Up to 65,000 devices |
| Data Rate | 250 kbps |
| Security | 128-bit AES encryption |
| Memory | 59,000 samples per node |
| Sampling Interval | 1 s – 2 h (user-configurable) |
| Power | Rechargeable internal battery + external 12 VDC @ 2 A adapter |
| Operating Temperature | −20 °C to +50 °C |
| Certifications | CE, FCC |
| Compliance | RoHS, FCC Part 15, EN 300 328 |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | NS-10AAL2-UFG |
| Output Type | Analog Voltage (0.15 V/°) & Temperature-Compensated |
| Measurement Principle | Electrolytic Capacitive Sensing |
| Axis Configuration | Dual-Axis (X/Y) |
| Full-Scale Range | ±10° |
| Resolution | 0.001° (typ.), 0.01° (min.) |
| Absolute Accuracy | ±0.08° to ±0.3° (within 0–50°C, temp.-compensated) |
| Nonlinearity | ≤1.5% FS |
| Cross-Axis Sensitivity | ≤0.15% FS |
| Temp. Drift | ≤8 mV/°C |
| Output Voltage Range | 0.3–4.7 V |
| Supply Voltage | 5 VDC ±5% |
| Operating Temp. | −40°C to +85°C |
| Storage Temp. | −40°C to +85°C |
| Weight | 20 g |
| Dimensions (W × D × H) | 45 × 45 × 14 mm (max. 20 mm height with mounting features) |
| Integrated Temperature Sensor | Yes |
| Mounting | PCB-mount (surface-mount compatible) |
| Vibration Resistance | High (designed for industrial mobile platforms) |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | PTS 420 |
| Pricing | Upon Request |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | TO2-1 |
| Measurement Principle | Electrochemical Micro-Fuel-Cell |
| Detection Range (Trace) | 0–10 ppm to 0–10,000 ppm O₂ |
| Detection Range (Percent-Level) | 0–25% O₂ |
| Response Time (T90) | 13 s |
| Accuracy | ±2% of reading |
| Repeatability | ±0.5% |
| Temperature Coefficient | 2.5 %/°C |
| Operating Temperature | 0–50 °C |
| Storage Temperature | 0–45 °C |
| Recommended Flow Rate | 0.5–2 SCFH (0.24–0.94 L/min) |
| Humidity Range | 0–100% RH (non-condensing) |
| Expected Service Life | 15–21 months |
| Shelf Life | 3 months |
| Warranty | 6 months |
| Output Signal | 330–585 µA |
| Electrical Interface | Center Foil (Negative), Outer Foil (Positive) |
| Compliance | Compatible with ASTM D3764, ISO 8573-3, USP <915>, FDA 21 CFR Part 11 (when integrated into validated systems) |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | YK160-162 |
| Price | Upon Request |
| Measurement Range | 0–1079.5 mm (across 60 standard configurations) |
| Dimensions (YK160) | 46.0 mm × 57.9 mm × 41.2 mm |
| Weight | 113 g |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model Range | YK173, YK174, YK175, YK176 |
| Pricing | Available Upon Request |
| Stroke Range | 0–165.1 mm (5 standard models) |
| Diameter × Length | 24.4 mm × 11.4 mm (YK170 reference) |
| Mass | 28 g (YK173) to 113 g (YK176) |
| Electrical Output | Analog voltage divider (0–V<sub>in</sub>) |
| Potentiometer Type | Single-turn, precision conductive plastic |
| Resistance | 5 kΩ ±10% |
| Mechanical/Electrical Travel | 340° |
| Linearity Error | ±0.5% FS max |
| Resolution | Theoretically infinite (analog continuous output) |
| Repeatability | < ±0.1% FS (AccuTrak™ hub design) |
| Operating Temperature | –65 °C to +125 °C (–85 °F to +257 °F) |
| Shock & Vibration | 100 g / 6 ms |
| Housing Material | Precision-machined anodized 2024 aluminum |
| Cable | 0.46 mm (0.018″) 7×7 stainless steel, min. tensile strength 177 N (40 lbf) |
| IP Rating | IP54 |
| Environmental Compliance | DO-160D (ED-14D), Category E1E1ABXHXFDXSAXXXXXXXXXX |
| Insulation Resistance | ≥1000 MΩ @ 500 VDC |
| Dielectric Withstand | 1000 VDC min |
| Tempco | ±400 ppm/°C max |
| Power Rating | 1.0 W @ 70 °C |
| Max Supply Voltage | 35 VDC |
| Max Supply Current | 12 mA |
| Output Smoothness | ≤0.1% FS |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | YK180-0803 Series |
| Range | 0–254.0 mm |
| Dimensions | 37.8 mm × 43.1 mm |
| Weight | 57 g |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | ZLPID-201 |
| Price Range | USD 700 – 1,400 (FOB) |
| Detection Range | 0–100,000 ppm (configurable spans) |
| Detection Limit | 1 ppb (typical, for isobutylene) |
| Response Time (T90) | ≤5 s |
| Operating Voltage | 3–5 V DC |
| Output Signal | 0.02–2.0 V (max 3.3 V) |
| Humidity Range | 0–99% RH (non-condensing) |
| Operating Temperature | −40 to +60 °C |
| Storage Temperature | 0 to +25 °C |
| Pressure Range | 800–1200 mbar |
| Zero Voltage (U₀) | >20 mV |
| Sensitivity | ≥40 mV/ppm (at low range, e.g., 0–100 ppm) down to ≥0.1 mV/ppm (at high range, e.g., 10,000–100,000 ppm) |
| Lifetime | >24 months (typical continuous operation) |
| Calibration Gas Recommendation | Isobutylene at ~50% of full scale |
| Compliance | RoHS-compliant construction |