Add to compare
BrandShanghai Fumi
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelBOD-5000
Instrument TypeLaboratory BOD Analyzer
Measurement PrincipleDissolved Oxygen (DO) Depletion Method per HJ 505–2009
Measurement Range0.00–6000.00 mg/L
Resolution0.01 mg/L
Accuracy±0.01 mg/L (at 20 °C, calibrated with traceable DO standards)
Sample Capacity62 positions
Incubation Temperature20.0 ± 0.1 °C (PID-controlled water-jacketed chamber)
Automatic DilutionYes, via stepper-motor-driven 50 mL syringe dispenser
Auto SealingYes, proprietary gas-tight cap system eliminating water seal requirement
Nutrient & Inhibitor AdditionAutomated, programmable dosing
DO Electrode TypePolarographic membrane electrode with integrated magnetic stirrer (adjustable pre-measurement agitation duration)
Data OutputEthernet-enabled LIMS integration, local PC (Windows 10), and mobile app (iOS/Android)
Power Supply220 V AC, 50 Hz, 1500 W
Dimensions100 × 80 × 185 cm (with casters)
ComplianceHJ 505–2009, GB/T 5750.7–2023, GB 17378.4–2007
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanghai Fumi
OriginShanghai, China
ModelFLOWSTAR2020
Product TypeContinuous Flow Analyzer
Wavelength Range270–1100 nm
Sample Volumes/Cup Capacity5 mL / 100 cups, 8 mL / 180 cups, 10 mL / 270 cups
Reagent Positions100, 180, or 270
Flow Cell Path Lengths10 mm, 30 mm, 50 mm
Light SourceLED or Krypton Lamp
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanghai Fumi
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional CategoryDomestic (PRC)
ModelFlowstar 2020NY
Price RangeUSD 28,000 – 70,000 (FOB Shanghai)
Instrument TypeContinuous Flow Analyzer (CFA)
Wavelength Range270–1100 nm
Sample Carrier Capacity100 / 180 / 270 positions (vials: 5 mL, 8 mL, or 10 mL)
Reagent Positions100 / 180 / 270
Flow Cell Path Lengths10 mm, 30 mm, 50 mm
Light SourceHigh-Stability LED and Krypton Lamp
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanghai Fumi
OriginShanghai, China
ModelFlowstar 2020YC
Product TypeContinuous Flow Analyzer (CFA)
Wavelength Range270–1100 nm
Sample Capacity100 / 180 / 270 positions (vials of 5, 8, or 10 mL)
Reagent Positions100 / 180 / 270
Flow Cell Pathlength10 mm, 30 mm, 50 mm
Light SourceLED or Krypton Lamp
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanghai Fumi
OriginShanghai, China
ModelFLOWSTAR 2020HS
Product TypeContinuous Flow Analyzer (CFA)
Wavelength Range270–1100 nm
Sample Volumes5 mL / 8 mL / 10 mL
Sample Rack Capacity100 / 180 / 270 positions
Reagent Positions100 / 180 / 270
Flow Cell Path Lengths10 mm / 30 mm / 50 mm
Light SourceLED or Krypton Lamp
Detection PrincipleSegmented Flow Analysis (SFA) with Air Segment Isolation, Dual-Beam Dual-Wavelength Photometry
ComplianceHY/T 147.1, GB 5750, HJ 665/667/670, SL/T 788, CJ/T 141, ISO 6878, ISO 11905-1, EPA 353.2, APHA 4500-N, AOAC Official Methods
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFumi
OriginShanghai, China
ModelCOD-1
Instrument TypeLaboratory Benchtop Analyzer
Sample Capacity100 positions
Digestion Temperature165 °C ±0.1 °C
Digestion Time15 min (configurable)
Cooling Endpoint60 °C (pre-mix) and 20 °C (pre-measurement)
Optical Wavelengths440 nm, 600 nm, 680 nm
Spectral Bandwidth≤10 nm
Absorbance Range0–3 A
Digestion Tube Dimensions16 mm × 100 mm (standard), optional 16 mm × 120 mm
Operating Environment10–30 °C
Power Supply220 V, 50 Hz
Power Consumption1280 W
Dimensions (W×D×H)940 mm × 680 mm × 885 mm
Weight80 kg
Remote ControlYes
LIMS IntegrationNetwork-enabled output
Mobile App SupportYes
Built-in Imaging SystemYes
Compliance StandardHJ/T 399–2007
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanghai Fumi
OriginShanghai, China
ModelFlowstar 2020FL
Product TypeContinuous Flow Analyzer (CFA)
Wavelength Range270–1100 nm
Sample Volumes5/8/10 mL per cup
Capacity100/180/270 positions
Reagent Positions100/180/270
Flow Cell Path Lengths10 mm, 30 mm, 50 mm
Light SourceLED or Krypton Lamp
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShanghai Fumi
OriginShanghai, China
ModelFlowstar 2020BJ
Product TypeContinuous Flow Analyzer (CFA)
Wavelength Range270–1100 nm
Sample Cup Capacity100 / 180 / 270 positions (5 mL, 8 mL, or 10 mL per cup)
Reagent Positions100 / 180 / 270
Flow Cell Pathlength10 mm, 30 mm, 50 mm
Light SourceLED or Krypton Lamp