| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BOD-5000 |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Dissolved Oxygen (DO) Depletion Method per HJ 505–2009 |
| Measurement Range | 0.00–6000.00 mg/L |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.01 mg/L (at 20 °C, calibrated with traceable DO standards) |
| Sample Capacity | 62 positions |
| Incubation Temperature | 20.0 ± 0.1 °C (PID-controlled water-jacketed chamber) |
| Automatic Dilution | Yes, via stepper-motor-driven 50 mL syringe dispenser |
| Auto Sealing | Yes, proprietary gas-tight cap system eliminating water seal requirement |
| Nutrient & Inhibitor Addition | Automated, programmable dosing |
| DO Electrode Type | Polarographic membrane electrode with integrated magnetic stirrer (adjustable pre-measurement agitation duration) |
| Data Output | Ethernet-enabled LIMS integration, local PC (Windows 10), and mobile app (iOS/Android) |
| Power Supply | 220 V AC, 50 Hz, 1500 W |
| Dimensions | 100 × 80 × 185 cm (with casters) |
| Compliance | HJ 505–2009, GB/T 5750.7–2023, GB 17378.4–2007 |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | FLOWSTAR2020 |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 270–1100 nm |
| Sample Volumes/Cup Capacity | 5 mL / 100 cups, 8 mL / 180 cups, 10 mL / 270 cups |
| Reagent Positions | 100, 180, or 270 |
| Flow Cell Path Lengths | 10 mm, 30 mm, 50 mm |
| Light Source | LED or Krypton Lamp |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | Flowstar 2020NY |
| Price Range | USD 28,000 – 70,000 (FOB Shanghai) |
| Instrument Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 270–1100 nm |
| Sample Carrier Capacity | 100 / 180 / 270 positions (vials: 5 mL, 8 mL, or 10 mL) |
| Reagent Positions | 100 / 180 / 270 |
| Flow Cell Path Lengths | 10 mm, 30 mm, 50 mm |
| Light Source | High-Stability LED and Krypton Lamp |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | Flowstar 2020YC |
| Product Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 270–1100 nm |
| Sample Capacity | 100 / 180 / 270 positions (vials of 5, 8, or 10 mL) |
| Reagent Positions | 100 / 180 / 270 |
| Flow Cell Pathlength | 10 mm, 30 mm, 50 mm |
| Light Source | LED or Krypton Lamp |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | FLOWSTAR 2020HS |
| Product Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 270–1100 nm |
| Sample Volumes | 5 mL / 8 mL / 10 mL |
| Sample Rack Capacity | 100 / 180 / 270 positions |
| Reagent Positions | 100 / 180 / 270 |
| Flow Cell Path Lengths | 10 mm / 30 mm / 50 mm |
| Light Source | LED or Krypton Lamp |
| Detection Principle | Segmented Flow Analysis (SFA) with Air Segment Isolation, Dual-Beam Dual-Wavelength Photometry |
| Compliance | HY/T 147.1, GB 5750, HJ 665/667/670, SL/T 788, CJ/T 141, ISO 6878, ISO 11905-1, EPA 353.2, APHA 4500-N, AOAC Official Methods |
| Brand | Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | COD-1 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Sample Capacity | 100 positions |
| Digestion Temperature | 165 °C ±0.1 °C |
| Digestion Time | 15 min (configurable) |
| Cooling Endpoint | 60 °C (pre-mix) and 20 °C (pre-measurement) |
| Optical Wavelengths | 440 nm, 600 nm, 680 nm |
| Spectral Bandwidth | ≤10 nm |
| Absorbance Range | 0–3 A |
| Digestion Tube Dimensions | 16 mm × 100 mm (standard), optional 16 mm × 120 mm |
| Operating Environment | 10–30 °C |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 1280 W |
| Dimensions (W×D×H) | 940 mm × 680 mm × 885 mm |
| Weight | 80 kg |
| Remote Control | Yes |
| LIMS Integration | Network-enabled output |
| Mobile App Support | Yes |
| Built-in Imaging System | Yes |
| Compliance Standard | HJ/T 399–2007 |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | Flowstar 2020FL |
| Product Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 270–1100 nm |
| Sample Volumes | 5/8/10 mL per cup |
| Capacity | 100/180/270 positions |
| Reagent Positions | 100/180/270 |
| Flow Cell Path Lengths | 10 mm, 30 mm, 50 mm |
| Light Source | LED or Krypton Lamp |
| Brand | Shanghai Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | Flowstar 2020BJ |
| Product Type | Continuous Flow Analyzer (CFA) |
| Wavelength Range | 270–1100 nm |
| Sample Cup Capacity | 100 / 180 / 270 positions (5 mL, 8 mL, or 10 mL per cup) |
| Reagent Positions | 100 / 180 / 270 |
| Flow Cell Pathlength | 10 mm, 30 mm, 50 mm |
| Light Source | LED or Krypton Lamp |