Empowering Scientific Discovery

Shanghai Metash Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetash Instruments
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelTOC-1700
Instrument TypeOnline & Offline TOC Analyzer
Detection PrincipleDirect Conductivity Detection
Oxidation MethodUV Photocatalytic Oxidation
Measurement Range0.001–1.5 ppm
Accuracy±3%
Resolution0.001 ppb
Detection Limit0.05 ppb
Repeatability≤3% RSD
Display7-inch Color Touchscreen
Data Storage8 GB Internal Flash Memory
Analysis Time≤3 minutes per sample
ComplianceCP2025 General Chapter <0901>, USP <643>, FDA 21 CFR Part 11 (Audit Trail & User Authentication)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetash Instruments
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory TOC Analyzer
ModelTOC-1500
Detection PrincipleDirect Conductivity Detection
Oxidation MethodUV Photocatalytic Oxidation
Measurement Range0.001–1.5 ppm (as C)
Accuracy±3% of reading
Resolution0.001 ppb
Detection Limit1 ppb (as C)
Repeatability≤3% RSD
Display7-inch color touchscreen
Data Storage8 GB internal flash memory
Analysis Time≤3 minutes per sample
ComplianceUSP <643>, CP 2025 Appendix IX Q, FDA 21 CFR Part 11 (audit trail & user authentication enabled)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetash Instruments
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelTOC-5000 RN
Instrument TypeLaboratory Benchtop TOC Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodHigh-Temperature Catalytic Combustion (680–900 °C)
Measurement Range0–1000 mg/L as C
Accuracy≤5% of reading
Resolution0.01 ppb (as C)
Detection LimitsTC: 50 µg/L
IC20 µg/L
Repeatability≤3% RSD
Sample FormAqueous liquid only
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetash Instruments
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory TOC Analyzer
ModelTOC-5000 RD
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodHigh-Temperature Catalytic Combustion
Measurement Range0–1000 mg/L (expandable to 100,000 mg/L)
Accuracy≤5%
Resolution0.01 ppb
Detection LimitsTC: 50 µg/L
IC20 µg/L
Repeatability≤3%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMetash Instruments
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory TOC Analyzer
ModelTOC-3000
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodUV/Persulfate Oxidation
Measurement Range0–10,000 ppm C
Accuracy≤5%
Resolution0.01 ppb C
Detection Limit5 ppb C
Repeatability≤3%
Sample VolumeUp to 20 mL
Carrier Gas RequirementHigh-Purity Nitrogen
Power Supply220 V ±10%, 50/60 Hz
Software OptionsStandard Control & Database Management / FDA 21 CFR Part 11 Compliant Audit Trail Edition
Optional Accessory20-Position Automated Sampler