BrandPeiou
OriginShanghai, China
ModelSKD-3104 / SKD-3106
Configuration4-channel or 6-channel modular distillation system
Detection Range1–600 g SO₂ (as per sample matrix and digestion protocol)
Control Interface7-inch high-resolution capacitive touchscreen
Heating MethodFar-infrared ceramic radiant heating (flame-free, uniform, corrosion-resistant)
Temperature RangeAmbient to 450 °C
Distillation Time Control1–600 min (per channel, independently programmable)
Cooling SystemExternal compact compressor-based chiller with closed-loop water circulation
Anti-siphon ProtectionIntegrated one-way valve in condensate path
Automation FeaturesIndependent channel control, built-in method library, programmable magnetic stirring (per receiver), automated nitrogen flow regulation, one-touch start/stop, timer-based endpoint detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPeiou
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSKD-800
Price RangeUSD 1,400 – 7,200 (FOB)
Instrument TypeProtein Nitrogen Determinator
Measurement PrincipleClassical Kjeldahl Method
Nitrogen Recovery Rate>99.5%
Repeatability (RSD)<0.5%
Detection Range0.08–240 mg N
Sample Capacity≤6 g solid or ≤16 mL liquid
Distillation Time1–99 min
Adjustable Distillation Power1500 W
Distillation Flow Rate15–30 mL/min
Data Storage100 pre-programmed methods + >1,000 sample records
Cooling Water Requirement≥1.5 L/min at ≤20 °C
Operating Pressure≥0.15 MPa
Dimensions (W×D×H)370 × 300 × 680 mm
Enclosure MaterialMolded ABS engineering plastic
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPeiou
OriginShanghai, China
ModelSKD-2000
PrincipleKjeldahl digestion and distillation followed by colorimetric titration
Nitrogen Range0.1–240 mg N
RepeatabilityRSD ≤ 0.5%
Detection Limit0.1–240 mg N
Recovery Rate>99.5%
Distillation Time3–8 min/sample
Distillation Rate15–30 mL/min (adjustable)
Titration Resolution0.002 µL/step
Minimum Titration Volume0.8 µL/step
Sample Capacity≤6 g solid or ≤16 mL liquid
Alkali Addition1–10 segments, 0–15 s interval
Delay Time0–1800 s
Dimensions500 × 350 × 720 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPeiou
OriginShanghai, China
ModelSKD-200
Measurement PrincipleKjeldahl Method
Nitrogen Range0.1–240 mg N
Repeatability±0.5% RSD
Detection Limit0.1–240 mg N
Recovery Rate>99.5%
Sample Capacity≤6 g (solid) or ≤16 mL (liquid)
Distillation Time3–8 min/sample
Distillation Flow Rate15–30 mL/min
Power Adjustment0–1500 W
Alkali Addition Time0–99 s (stepwise)
Acid Addition Time0–99 s
Distillation Duration Setting0–99 min
Data Storage10 programmable methods
Safety FeaturesOverpressure protection, dry-run prevention via real-time liquid level monitoring, emergency stop
Housing MaterialMolded ABS engineering plastic (acid/alkali resistant)
TubingCustom corrosion-resistant polymer tubing (≥3-year service life)
Dimensions370 × 300 × 680 mm
Net Weight15 kg
Power SupplyAC 220 V ±10%, 50 Hz
Cooling Water Requirement≥0.15 MPa pressure, ≤20 °C inlet temperature
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPeiou
OriginShanghai, China
ModelSKD-3106
TypeIntelligent Automated Distillation System
Heating MethodFar-infrared Ceramic Radiant Heating
Temperature RangeAmbient to 450 °C
Time Control1–600 min
Distillation Channels4 or 6 independent channels
Cooling SystemExternal Compact Compressor-based Closed-loop Chiller
Display7-inch HD Touchscreen LCD
Control CoreMicrocontroller-based Embedded System
Anti-siphon ProtectionIntegrated One-way Flow Valve
Nitrogen Flow ControlBuilt-in Regulated Pneumatic Module
Method StoragePreloaded & User-Editable SOPs
Automation LevelFully Unattended Operation (Heating, Cooling, Stirring, Distillation, N₂ Triggering, Endpoint Termination)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPeiou
OriginShanghai, China
ModelSKD-100
PrincipleKjeldahl Method
Nitrogen Range0.1–240 mg N
RepeatabilityRSD ≤ 0.5%
Detection Limit0.1–240 mg N
Recovery Rate>99.5%
Sample Capacity≤6 g (solid) or ≤16 mL (liquid)
Distillation Time3–8 min/sample
Distillation Flow Rate15–30 mL/min
Alkali Addition Time0–99 s
Distillation Duration Setting0–99 min
Power Adjustment0–1500 W
Data Storage10 programmable distillation/alkalization protocols
Safety FeaturesReal-time liquid-level monitoring, overpressure protection, dry-run prevention, emergency stop
Housing MaterialIntegrated ABS engineering plastic enclosure
TubingAcid- and alkali-resistant custom polymer tubing (≥3-year service life)
Dimensions370 × 300 × 680 mm
Net Weight15 kg
Power SupplyAC 220 V ±10%, 50 Hz
Water Supply≥0.15 MPa pressure, ≤20 °C inlet temperature