Empowering Scientific Discovery

Shanghai Wufeng Scientific Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWufeng
OriginShanghai, China
ModelLC-80
Instrument TypeConventional HPLC System
Flow Rate Range0.001–5.000 mL/min
Maximum Pressure40 MPa
Injection ModeManual
Injection Volume Range1–100 µL
Column Oven Temperature ControlAmbient Only
UV-Vis Wavelength Range190–680 nm
Data Acquisition Frequency10 Hz
Flow Precision (RSD)< 0.1%
Flow Accuracy (Ss)≤ ±1%
Retention Time Repeatability (RSD₆)≤ ±0.2% (naphthalene/methanol)
Peak Area Repeatability (RSD₆)≤ ±0.5% (naphthalene/methanol)
Pressure Pulsation< 0.1 MPa
Spectral Bandwidth8 nm
Wavelength Accuracy±1 nm
Wavelength Precision< 0.1 nm
Baseline Noise≤ 0.25 × 10⁻⁵ AU (static)
Baseline Drift≤ 0.4 × 10⁻⁴ AU/hr (static)
LOD (naphthalene/methanol)≤ 5 × 10⁻⁹ g/mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWufeng
OriginShanghai, China
ModelEX1600
Instrument TypeFast HPLC System
Flow Rate Range0.001–5.0 mL/min
Maximum Pressure42 MPa
Sample Tray Capacity108 positions (2 mL vials)
Injection Volume Range0.1–120 µL
Column Oven Temperature Range10–85 °C
UV-Vis Wavelength Range180–700 nm
Data Acquisition Rate20 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWufeng
OriginShanghai, China
ModelEX1800 UHPLC/HPLC
Instrument TypeTwo-Dimensional Ultra-High-Performance Liquid Chromatograph
Flow Rate Range0.001–10 mL/min
Maximum Operating Pressure120 MPa (UHPLC mode) / 60–70 MPa (HPLC mode)
Flow Precision≤0.06% RSD
Autosampler Capacity330 positions (1 mL vials), 192 positions (2 mL vials), 108 positions (4 mL vials), 48 positions (10 mL vials)
Injection Volume Range0.1–120 µL
Column Oven Temperature Range10 °C below ambient to 80 °C
UV-Vis Detection Wavelength Range190–700 nm (standard) / optional 190–900 nm
Data Acquisition Rateup to 100 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWufeng
OriginShanghai, China
ModelEX1700
Instrument TypeConventional HPLC (UHPLC-capable)
Flow Rate Range0.0001–5 mL/min
Maximum Pressure60 MPa
Autosampler Capacity96 positions (2 mL vials)
Injection Volume Range1–50 µL
Column Oven Temperature Range4–85 °C
UV-Vis Wavelength Range170–700 nm
Data Acquisition Rate100 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWufeng
OriginShanghai, China
ModelLC-100 (Isocratic Configuration)
Pump Flow Range0.001–9.999 mL/min
Max Pressure42 MPa
Sample Injection Volume1–200 µL
Injection Tray Capacity108 × 2 mL vials
Column Oven Temperature Range5 °C above ambient to 80 °C
UV Detector Wavelength Range190–680 nm
Data Acquisition Rate10 Hz
Baseline Noise (UV)≤2×10⁻⁵ AU (peak-to-peak, methanol, 1 mL/min, 254 nm)
Detection Limit≤5×10⁻⁹ g/mL (naphthalene in methanol)
Wavelength Accuracy≤±2 nm
Wavelength Repeatability<0.1 nm
Flow Precision±0.3% RSD
Flow Accuracy±2%
Cell Volume8 µL
Path Length8 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWufeng
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelLC-80 ChroMini
Instrument TypePortable HPLC System
Flow Rate Range0.001–5.000 mL/min
Maximum Operating Pressure40 MPa
Sample Tray Capacity2 mL × 54 positions × 2 racks
Injection Volume Range1–50 µL
Column Oven Temperature Control Range4–80 °C
UV-Vis Detector Wavelength Range190–700 nm
Data Acquisition FrequencyUp to 100 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWufeng
OriginShanghai, China
ModelLC-100 (Gradient Configuration)
Instrument TypeConventional HPLC System
Flow Rate Range0.001–9.999 mL/min
Maximum Pressure42 MPa
Autosampler Capacity108 positions (2 mL vials) / 70 positions (4 mL vials) / 20 positions (10 mL vials)
Injection Volume Range0.1–200 µL (with interchangeable sample loops)
Column Oven Temperature Range(Ambient + 5 °C) to 80 °C
UV-Vis Wavelength Range190–800 nm
Data Acquisition Rate10 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelLC-100 Isocratic Configuration
Instrument TypeConventional High-Performance Liquid Chromatograph
Flow Rate Range0.001–9.999 mL/min
Maximum Pressure42 MPa
Sample Tray Capacity54 positions × 2 mL vials / 35 positions × 4 mL vials
Injection Volume Range0.1–120 µL
Column Oven Temperature Range5 °C above ambient to 80 °C
UV-Vis Wavelength Range190–900 nm
Data Acquisition Frequency50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWufeng
OriginShanghai, China
ModelLC-100
Instrument TypeConventional HPLC System
Flow Rate Range0.001–9.999 mL/min
Maximum Pressure42 MPa
Sample Tray Capacity108 positions (2 mL vials) / 70 positions (4 mL vials) / 30 positions (10 mL vials)
Injection Volume Range0.1–200 µL (with interchangeable loop)
Column Oven Temperature Range(Ambient + 5)°C to 80°C
UV-Vis Wavelength Range190–700 nm (standard) / 190–900 nm (optional DAD)
Data Acquisition Rateup to 100 Hz (DAD)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWufeng
ModelEX1600
Instrument TypeConventional HPLC System
Flow Rate Range0.1–3.0 mL/min
Max Operating Pressure42 MPa
Autosampler Capacity2 × 54 positions
Injection Volume Range0.1–120 µL
Column Oven Temperature RangeAmbient +10°C to 85°C
UV Detector Wavelength Range190–900 nm (D₂ + W lamp)
Data Acquisition RateUp to 100 Hz
Baseline Noise (UV)≤ ±0.2 × 10⁻⁵ AU
Baseline Drift (UV)≤ 0.3 × 10⁻⁴ AU/hr
Retention Time PrecisionRSD < 0.06%
Injection PrecisionRSD < 0.3% (full-loop mode)
Show next