| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH1100-HSC |
| Spray Mode | Continuous/Cyclic Spray |
| Temperature Range | 20–70 °C |
| Chamber Volume | 1103 L |
| Humidity Control | Full-Variable RH via Air Preconditioning System |
| Spray Function | Adjustable High-Flow Liquid Shower Module |
| Nozzle Maintenance | Automatic Self-Cleaning Mechanism |
| Internal Solution Reservoir | 120 L with Filtration & Low-Level Alarm |
| Compliance | GMW 14872, SAE J2334, ISO 11997, VW PV1210, Ford CETP, Renault D17 2025, JASO M609, GB/T 24135, Prohesion™ Protocol |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP-600, Q-FOG SSP-1100, Q-FOG CCT-600, Q-FOG CCT-1100 |
| Temperature Range | 20–70 °C (spray/dry), 20–60 °C (RH/humidity) |
| Chamber Capacity | 640 L (SSP/CCT-600), 1103 L (SSP/CCT-1100) |
| Salt Solution Reservoir | 120 L |
| Sample Capacity | 160 panels (75 × 150 mm) for 600-series |
| Spray Rate | 1–2 mL/80 cm²·hr |
| Air Pressure | 0.7–1.0 kg/cm² (≈70–100 kPa) |
| Humidity Control | 95–100% RH (CCT models only) |
| Power Supply | 208–230 V, 50/60 Hz, 13–38 A |
| Weight (dry) | 224–378 kg |
| Water Purity Requirement | <8 ppm TDS, >50 kΩ·cm resistivity |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH-600 |
| Temperature Range | 20–60 °C (spray/soak), 20–70 °C (dry), 20–60 °C (RH) |
| Internal Chamber Volume | 640 L (incl. lid) |
| Salt Solution Reservoir | 120 L |
| Sample Capacity | 160 × 75 mm × 150 mm panels |
| RH Control Range | Fully adjustable 10–95% RH (CRH model only) |
| Compressed Air Requirement | 4–10 bar, ≤1.7 L/s |
| Deionized Water Specification | <8 ppm TDS, >50 kΩ·cm resistivity |
| Power Supply | 230 V ±10%, 50/60 Hz, 32 A single-phase |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT SSP CRH |
| Temperature Range | 20–60 °C (spray/soak), 20–70 °C (dry), 20–60 °C (RH/humidity) |
| Chamber Capacity | 640 L (CCT-600/SSP-600/CRH-600) or 1103 L (CCT-1100/SSP-1100/CRH-1100) |
| Internal Salt Solution Reservoir | 120 L |
| Sample Rack Capacity | 160 pcs (75 mm × 150 mm) for 600-series |
| Relative Humidity Control | 95–100% RH (CCT), fully adjustable 10–95% RH (CRH) |
| Air Pressure Requirement | 3–10 bar |
| Water Purity | <8 ppm TDS, resistivity >50 kΩ·cm |
| Power Supply | 208–230 V, 50/60 Hz, up to 38 A |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH |
| Temperature Range | 20–60 °C (spray/soak), 20–70 °C (dry), 20–60 °C (RH) |
| Humidity Control | Fully adjustable relative humidity (RH), 10–95% RH (CRH-specific capability) |
| Internal Solution Reservoir | 120 L |
| Chamber Capacity | 640 L (CRH-600) or 1103 L (CRH-1100) |
| Sample Capacity | 160 plates (75 × 150 mm) or 240 plates (75 × 150 mm) |
| Water Purity Requirement | <8 ppm TDS, resistivity >50 kΩ·cm |
| Compressed Air | 4–10 bar (60–150 psi), max. 1.7 L/s (3.5 CFM) |
| Power Supply | 208–230 V, 50/60 Hz, up to 38 A |
| Weight (dry) | 333 kg (CRH-600), 378 kg (CRH-1100) |