Empowering Scientific Discovery

Shanghai Yunding International Trade Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelQ-SUN® Xe-8
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
Manufacturer StatusAuthorized Distributor
Product OriginImported
ModelQUV
Irradiance Range0.48–0.95 W/m² @ 340 nm
Test Duration1–9999 hours (programmable)
UV Wavelength Range250–400 nm
Chamber CapacityUp to 48 specimens (75 mm × 150 mm each)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKurabo
OriginJapan
ModelRX410
Measurement PrincipleMulti-Wavelength Infrared Absorption Spectroscopy
Detection CapabilitySimultaneous Non-Contact Measurement of Base Film Thickness and Heat-Resistant Coating Thickness (or Areal Mass)
Optical ConfigurationRotating Filter Wheel (6-position, 3 active wavelengths standard)
Spot Size20 × 30 mm (elliptical)
Standoff Distance20 mm (sensor-to-sample), 40 mm (inter-sensor gap)
Response Time≤50 ms
Output Options0–10 V analog or 4–20 mA current loop
Operating Temperature5–40 °C (non-condensing, ambient ≤35 °C without forced air cooling)
Power SupplyAC 100 V ±10%, 50/60 Hz, 200 VA per unit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
Distributor StatusAuthorized Distributor
Product TypeSpectrophotometric Colorimeter
Instrument Form FactorBenchtop
Optical Geometryd/8° integrating sphere
Light SourceLED
Spectral Range400–700 nm, 360–780 nm, or 350–1050 nm (model-dependent)
RepeatabilityΔE*₀₀ ≤ 0.03 (average, CIE L*a*b* color space)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelUltraScan PRO
Product TypeSpectrophotometric Colorimeter
Instrument TypeBenchtop
Optical Geometryd/8° Integrating Sphere
Light SourcePulsed Xenon Lamp
Spectral Range350–1050 nm
Wavelength Interval2 nm (acquisition), 5 nm (reporting)
Repeatability≤0.03 ΔE*ab (CIE Lab, 20 measurements on standard white tile)
Reflectance/Absorbance Measurement ModesSpecular Component Included/Excluded (SCI/SCE) Auto-Switchable
Aperture Sizes19 mm (1.00″), 9 mm (0.50″), 4 mm (0.25″)
Transmission Path Length80 mm
Integrating Sphere Diameter152 mm
Sphere CoatingSpectraflect™
Mirror & Port CoatingDuraflect™
ComplianceASTM D2244, ASTM E308, ISO 7724, ISO 11664, CIE No. 15, AATCC Evaluation Procedure 1, USP <1061>, FDA 21 CFR Part 11 (with optional software configuration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelVST
Instrument TypeBenchtop
Light SourceLED
Spectral Range400–700 nm
Repeatability0.02 ΔE* (CIE Lab)
ConnectivityMicro-USB, Ethernet
Sample AccessRemovable front door
Display7-inch capacitive touchscreen
ComplianceSupports ASTM D1003, ISO 14782, ISO 6222, USP <631>, EP 2.2.17, JP 2.05
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelAGR-Agera
Product TypeBenchtop Spectrophotometer
Optical Geometry0°/45° Annular Illumination (15-point fiber-optic averaging)
Light SourceFull-spectrum LED (360–700 nm) with UV control
Spectral Range360–700 nm
RepeatabilityΔE2000 < 0.03 (CIEL*a*b*, max)
ComplianceASTM D1925, ASTM E313, ASTM D6290 (45–52 mm aperture), ASTM D2457, ASTM D523, ISO 2813, HG/T 3862-2006, ASTM E308
Display7″ 1280×800 capacitive industrial touchscreen
Data InterfacesUSB, Ethernet, Wi-Fi, Bluetooth, Email export
SoftwareEmbedded EasyMatch Essentials QC (FDA 21 CFR Part 11 electronic signature optional)
Aperture OptionsXL (51 mm), L (25.4 mm), M (16.9 mm), Custom 30 mm
Calibration StandardsNIST-traceable white tile, certified green tile, ASTM/ISO-traceable black glass gloss standard
Optical DesignSealed dual-beam spectrophotometer with 256-element diode array and holographic concave grating
UV ModeToggleable UV-included / UV-excluded reporting
MaintenanceFanless, filterless, robust industrial enclosure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelColorFlex EZ Tomato
Product TypeBenchtop Spectrophotometric Colorimeter
Optical Geometry45°/0°
Light SourcePulsed Xenon Lamp
Spectral Range400–700 nm
Repeatability< 0.04 ΔE* (20 measurements, average)
Aperture Size / Measurement Area31.8 mm (1.25″) / 25.4 mm (1.00″)
Lamp Lifetime> 500,000 flashes
Inter-instrument Agreement≤ 0.15 ΔE* (CIE L*a*b*, average)
IlluminantsA, C, D65, TL84, F
Observers2° and 10° standard observer
Color SpacesCIE XYZ, Yxy, L*a*b*, L*C*h°, Hunter Lab
Color IndicesΔE*, ΔE, ΔEcmc, Whiteness, Yellowness, Metamerism Index, Brightness at 457 nm
Tomato-Specific Indicesa/b Ratio, Tomato Chroma Grade, Tomato Juice Grade, Tomato Puree Grade, Tomato Ketchup Grade, Tomato Sauce Grade
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQ-SUN Xe-3 Series
Cooling MethodAir-cooled
Lamp ConfigurationThree independent xenon arc lamps
Filter OptionsDaylight, Window Glass, Extended UV
Irradiance ControlSOLAR EYE® broadband or narrowband (340 nm, 420 nm, TUV)
Black Panel Temperature Range42–120 °C
Chamber Air Temperature Range25–45 °C (dark cycle), 35–65 °C (light cycle)
Relative Humidity ControlStandard, 10–95% RH
Sample Tray Dimensions451 mm × 718 mm
Spray OptionsFront spray, back spray, dual-fluid spray (e.g., acid rain, detergent solution)
ComplianceASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9
Calibration TraceabilityNIST-traceable, ISO/IEC 17025 accredited (A2LA Cert. #2382-01, #2383-02, #2383-03)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelSpectraTrend HT
Product TypeColor Difference Meter
Instrument TypeOnline
Optical Geometry0°/45° Integrating Sphere
Light SourceLED
Spectral Range400–700 nm
RepeatabilityΔE* ≤ 0.03 (mean, measured 20× on standard white tile)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelColorFlex-EZ-Coffee
Optical Geometry45°/0°
Measurement PrincipleReflectance Spectrophotometry (Visible Spectrum, 400–700 nm)
Compliant StandardsASTM D2244, ISO 11664-4, CIE No. 15:2018
Preloaded Color ScalesHCCI (HunterLab Coffee Color Index), SCAA Roast Scale (0–100), SCAA Number Scale (0–100), CIE L*a*b*, Hunter L,a,b
Sample TypesGround roasted coffee, freeze-dried coffee granules, instant coffee powders, and other reflective solids/powders
Data OutputSpectral reflectance (31 data points), tristimulus values, color differences (ΔE*ab, ΔE00), batch consistency metrics
Software CompatibilityEasyMatch QC (Windows), supports FDA 21 CFR Part 11 audit trail (with optional user permissions module)
CalibrationIntegrated white tile + PQ Coffee Calibration Standard
PortabilityOptional IP65-rated custom carry case with integrated accessories
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
Manufacturer StatusAuthorized Distributor
Product CategoryImported Instrument
ModelAgera
Product TypeSpectrophotometer
Instrument TypeBenchtop
Light SourceFull-Spectrum LED
Spectral Range360–700 nm
RepeatabilityΔE₀₀ < 0.03 (CIE L*a*b*, maximum)
Optical Geometry0°/45° annular illumination with 15-point fiber-optic averaging
Gloss MeasurementIntegrated 60° glossmeter compliant with ASTM D2457, ASTM D523, and ISO 2813
Image CaptureBuilt-in 5 MP camera at 45° angle under full-spectrum LED illumination
Display7-inch 1280×800 industrial capacitive touchscreen
SoftwareEmbedded EasyMatch Essentials QC software with optional FDA 21 CFR Part 11 electronic signature capability
Calibration StandardsNIST-traceable white tile, certified green tile, and ASTM/ISO-traceable black glass gloss standard
Measurement AperturesXL (51 mm), L (25.4 mm), M (16.9 mm), and optional 30 mm custom aperture
UV ControlAdjustable UV component with factory calibration and user-defined fluorescent standard alignment
Spectral Resolution256-element diode array with high-resolution concave holographic grating
Optical ArchitectureSealed dual-beam spectrophotometric design
Environmental RobustnessFanless, filterless, sealed optical path for low maintenance and high long-term stability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVeriVide
OriginUnited Kingdom
ModelDigieye
Product TypeSpectrophotometric Imaging Color Measurement System
Instrument Form FactorBenchtop
Optical Geometry0°/45° and d/8° dual-mode compliant
IlluminantStandard D65 (integrated in light booth)
Spectral Range380–730 nm (visible spectrum)
RepeatabilityΔE₀₀ < 0.1 (within-subject, same conditions)
Camera Resolution17 MP DSLR
Light Booth Dimensions700 W × 800 D × 860 H mm
Max Sample Size300 W × 210 D × 80 H mm
Display Characterization AccuracyΔE₀₀ < 1.2 (after calibration)
Camera Characterization AccuracyΔE₀₀ < 1.2 (image-to-CIE conversion)
Booth Imaging AccuracyΔE₀₀ < 1.0 (under controlled illumination)
UV Excitation SourceOptional LED-based UV control module
Calibration Standards>150-tile verification chart + neutral gray sample holder (Munsell N5) + diffuse white tile
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelVista
Instrument TypeBenchtop Spectrophotometer
Optical ArchitectureDual-Beam, Tt/0° or Td/0°
Light SourceFull-Spectrum LED
Spectral Range400–700 nm
Spectral Resolution<3 nm
Effective Bandwidth10 nm
Photometric Range0–150%
Repeatability<0.025 ΔE* (30 measurements)
Measurement Time<2.5 s (color), <5 s (haze)
Path Length100 mm
Illuminant/ObserverD65/10°, C/2°
Display1280×800 Touchscreen
Power Supply100–240 VAC, 47–63 Hz, 60 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelQ-SUN Xe-1
Xenon Lamp PowerNot specified (air-cooled single-lamp system)
Irradiance ControlSOLAR EYE broadband or narrowband (340 nm, 420 nm, or TUV)
Light CycleProgrammable irradiance-on/off cycles with optional water spray and refrigeration
Dimensions (W×D×H)610 × 584 × 533 mm
Sample Tray251 × 457 mm (horizontal, flat), accommodates up to seventeen 51 × 102 mm specimens
Lamp Life~1500 hours (air-cooled xenon arc lamp)
Temperature RangeBlack Panel: 35–103 °C
Air Temperature (with refrigeration option)19–103 °C
CalibrationNIST-traceable CT202 (temperature) and CR20 (irradiance)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelUltraScan VIS
Product TypeSpectrophotometer
Instrument TypeBenchtop
Optical Geometryd/8° integrating sphere
Light SourcePulsed Xenon Lamp
Spectral Range360–780 nm
Repeatability≤ 0.03 ΔE*ab (CIE Lab, mean of 20 measurements on certified white tile)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelCRH1100-HSC
Spray ModeContinuous/Cyclic Spray
Temperature Range20–70 °C
Chamber Volume1103 L
Humidity ControlFull-Variable RH via Air Preconditioning System
Spray FunctionAdjustable High-Flow Liquid Shower Module
Nozzle MaintenanceAutomatic Self-Cleaning Mechanism
Internal Solution Reservoir120 L with Filtration & Low-Level Alarm
ComplianceGMW 14872, SAE J2334, ISO 11997, VW PV1210, Ford CETP, Renault D17 2025, JASO M609, GB/T 24135, Prohesion™ Protocol
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCalpas
ModelCALPAS
OriginSouth Korea
Instrument TypeAutomated Optical Impurity Detection System for Polymer Powders & Pellets
Measurement PrincipleHigh-Resolution Digital Imaging + Multispectral Color Discrimination + Geometric Morphology Analysis
Detection Range50–30,000 µm
Throughput500 g powder / 3 min
RepeatabilitySTD < 1% (powder), STD < 5% (pellets)
ComplianceISO 14484, ASTM D7618 (referenced), GLP-aligned data audit trail capability
Illumination OptionsAdjustable multi-source LED (central, square, coaxial, backlight)
CameraHigh-speed monochrome/RGB CCD (user-specifiable resolution & frame rate)
Feed System3-axis vibratory feeder with amplitude & height control
SoftwareCALPAS Vision v4.x with customizable impurity classification, batch reporting, and calibration traceability per ISO/IEC 17025 guidelines
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
Model SeriesHunterLab Spectrophotometric Colorimeters
Product TypeSpectrophotometric Colorimeter
Instrument TypeBenchtop
Optical Geometryd/8° Integrating Sphere (UltraScan Pro, UltraScan VIS), 0°/45° (Agera), 45°/0° (ColorFlex EZ, MiniScan EZ), 0°/30° (Aeros, STHT), d/0° (Vista)
Light SourceXenon Arc Lamp
Spectral Range360–780 nm (UltraScan VIS), 350–1050 nm (UltraScan Pro), 400–700 nm (select models)
RepeatabilityΔE*ab ≤ 0.03 (average, CIE Lab scale)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHunterLab
OriginUSA
ModelColorFlex EZ-Citrus
Product TypeSpectrophotometric Colorimeter
Instrument TypeBenchtop
Optical Geometry45°/0°
Light SourcePulsed Xenon Lamp
Spectral Range400–700 nm
Repeatability≤ 0.04 ΔE* (CIE L*a*b*, 20 measurements on standard white tile)
Inter-instrument Agreement≤ 0.15 ΔE* (CIE L*a*b*, average across units)
Aperture Size / Measurement Area31.8 mm (1.25″) / 25.4 mm (1.00″)
IlluminantsA, C, D65, TL84, F
Standard Observers2° and 10°
Color SpacesCIE XYZ, Yxy, L*a*b*, L*C*h°, Hunter Lab
Color IndicesΔE*, ΔE, ΔEcmc, Whiteness, Yellowness, Metamerism Index, Brightness at 457 nm, Citrus Number, Citrus Redness, Citrus Yellowness
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQUV/se, QUV/spray
Irradiance Range0.48–0.95 W/m² @ 340 nm
Exposure Duration1–9999 hours (programmable)
UV Wavelength Range250–400 nm
Chamber CapacityUp to 48 specimens (75 mm × 150 mm each)
ComplianceASTM G154, ISO 4892-3, IEC 61215, SAE J2020, GB/T 14522, FDA 21 CFR Part 11 (software-enabled audit trail optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
Manufacturer StatusAuthorized Distributor
Product OriginImported
ModelXe-3HSE
Xenon Lamp Power1800 W × 3
Irradiance Range0.55–1.3 W/m²/nm @ 340 nm
Light Exposure Cycle1–999 h
Humidity Range20–95% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKurabo
OriginJapan
ModelNR-2100IB
Measurement PrincipleInfrared Reflectance Absorption (Rotating Filter Method)
Thickness Range0.1–10 µm
Repeatability< 0.01 µm
Measurement Area518 × 36 mm (elliptical)
Dimensions (W×D×H)100 × 210 × 145 mm
Weight~1.5 kg
Light Source ConfigurationP-polarized Incident Beam
Integrated Thermal PrinterYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelQsun QUV
Irradiance Range0.48–0.95 W/m²
Exposure Duration1–9999 hours (adjustable per standard)
UV Wavelength Range250–400 nm
Chamber CapacityUp to 48 specimens (75 mm × 150 mm each)