Empowering Scientific Discovery

Shanghai Yunding International Trade Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelQ-SUN® Xe-8
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
Manufacturer StatusAuthorized Distributor
Product OriginImported
ModelQUV
Irradiance Range0.48–0.95 W/m² @ 340 nm
Test Duration1–9999 hours (programmable)
UV Wavelength Range250–400 nm
Chamber CapacityUp to 48 specimens (75 mm × 150 mm each)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQ-SUN Xe-3 Series
Cooling MethodAir-cooled
Lamp ConfigurationThree independent xenon arc lamps
Filter OptionsDaylight, Window Glass, Extended UV
Irradiance ControlSOLAR EYE® broadband or narrowband (340 nm, 420 nm, TUV)
Black Panel Temperature Range42–120 °C
Chamber Air Temperature Range25–45 °C (dark cycle), 35–65 °C (light cycle)
Relative Humidity ControlStandard, 10–95% RH
Sample Tray Dimensions451 mm × 718 mm
Spray OptionsFront spray, back spray, dual-fluid spray (e.g., acid rain, detergent solution)
ComplianceASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9
Calibration TraceabilityNIST-traceable, ISO/IEC 17025 accredited (A2LA Cert. #2382-01, #2383-02, #2383-03)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelQ-SUN Xe-1
Xenon Lamp PowerNot specified (air-cooled single-lamp system)
Irradiance ControlSOLAR EYE broadband or narrowband (340 nm, 420 nm, or TUV)
Light CycleProgrammable irradiance-on/off cycles with optional water spray and refrigeration
Dimensions (W×D×H)610 × 584 × 533 mm
Sample Tray251 × 457 mm (horizontal, flat), accommodates up to seventeen 51 × 102 mm specimens
Lamp Life~1500 hours (air-cooled xenon arc lamp)
Temperature RangeBlack Panel: 35–103 °C
Air Temperature (with refrigeration option)19–103 °C
CalibrationNIST-traceable CT202 (temperature) and CR20 (irradiance)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelCRH1100-HSC
Spray ModeContinuous/Cyclic Spray
Temperature Range20–70 °C
Chamber Volume1103 L
Humidity ControlFull-Variable RH via Air Preconditioning System
Spray FunctionAdjustable High-Flow Liquid Shower Module
Nozzle MaintenanceAutomatic Self-Cleaning Mechanism
Internal Solution Reservoir120 L with Filtration & Low-Level Alarm
ComplianceGMW 14872, SAE J2334, ISO 11997, VW PV1210, Ford CETP, Renault D17 2025, JASO M609, GB/T 24135, Prohesion™ Protocol
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQUV/se, QUV/spray
Irradiance Range0.48–0.95 W/m² @ 340 nm
Exposure Duration1–9999 hours (programmable)
UV Wavelength Range250–400 nm
Chamber CapacityUp to 48 specimens (75 mm × 150 mm each)
ComplianceASTM G154, ISO 4892-3, IEC 61215, SAE J2020, GB/T 14522, FDA 21 CFR Part 11 (software-enabled audit trail optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
Manufacturer StatusAuthorized Distributor
Product OriginImported
ModelXe-3HSE
Xenon Lamp Power1800 W × 3
Irradiance Range0.55–1.3 W/m²/nm @ 340 nm
Light Exposure Cycle1–999 h
Humidity Range20–95% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelQsun QUV
Irradiance Range0.48–0.95 W/m²
Exposure Duration1–9999 hours (adjustable per standard)
UV Wavelength Range250–400 nm
Chamber CapacityUp to 48 specimens (75 mm × 150 mm each)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelQ-Sun Xe-3HBSE
Xenon Lamp Power3 × 1800 W
Irradiance Range0.55–1.3 W/m²/nm @ 340 nm
Light Exposure Cycle1–999 h
Humidity Range20–95% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQ-SUN Xe-3
Xenon Lamp Power1800 W × 3
Irradiance Range0.55–1.3 W/m²/nm @ 340 nm
Light Exposure Cycle1–999 h
Humidity Range20–95% RH
Cooling MethodAir-cooled
Sample Tray Dimensions451 mm × 718 mm
Filter OptionsDaylight, Window Glass, Extended UV
Optional FeaturesFront/Back Dual Spray, Refrigerated Chamber (Xe-3-HSCE), SOLAR EYE Irradiance Control, NIST-Traceable Calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQ-FOG SSP-600, Q-FOG SSP-1100, Q-FOG CCT-600, Q-FOG CCT-1100
Temperature Range20–70 °C (spray/dry), 20–60 °C (RH/humidity)
Chamber Capacity640 L (SSP/CCT-600), 1103 L (SSP/CCT-1100)
Salt Solution Reservoir120 L
Sample Capacity160 panels (75 × 150 mm) for 600-series
Spray Rate1–2 mL/80 cm²·hr
Air Pressure0.7–1.0 kg/cm² (≈70–100 kPa)
Humidity Control95–100% RH (CCT models only)
Power Supply208–230 V, 50/60 Hz, 13–38 A
Weight (dry)224–378 kg
Water Purity Requirement<8 ppm TDS, >50 kΩ·cm resistivity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelQUV/se
Irradiance Range0.48–0.95 W/m² @ 340 nm
Exposure TimeAdjustable from 1 to 9999 hours
UV Wavelength Range250–400 nm
Chamber CapacityUp to 48 specimens (75 mm × 150 mm each)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelCRH-600
Temperature Range20–60 °C (spray/soak), 20–70 °C (dry), 20–60 °C (RH)
Internal Chamber Volume640 L (incl. lid)
Salt Solution Reservoir120 L
Sample Capacity160 × 75 mm × 150 mm panels
RH Control RangeFully adjustable 10–95% RH (CRH model only)
Compressed Air Requirement4–10 bar, ≤1.7 L/s
Deionized Water Specification<8 ppm TDS, >50 kΩ·cm resistivity
Power Supply230 V ±10%, 50/60 Hz, 32 A single-phase
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
Distributor TypeAuthorized Distributor
Import StatusImported
ModelQUV/Spray
Irradiance Range0.48–0.95 W/m² @ 340 nm
Test DurationAdjustable from 1 to 9999 hours
UV Wavelength Range250–400 nm
Chamber CapacityUp to 48 specimens (75 mm × 150 mm each)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQ-FOG CCT SSP CRH
Temperature Range20–60 °C (spray/soak), 20–70 °C (dry), 20–60 °C (RH/humidity)
Chamber Capacity640 L (CCT-600/SSP-600/CRH-600) or 1103 L (CCT-1100/SSP-1100/CRH-1100)
Internal Salt Solution Reservoir120 L
Sample Rack Capacity160 pcs (75 mm × 150 mm) for 600-series
Relative Humidity Control95–100% RH (CCT), fully adjustable 10–95% RH (CRH)
Air Pressure Requirement3–10 bar
Water Purity<8 ppm TDS, resistivity >50 kΩ·cm
Power Supply208–230 V, 50/60 Hz, up to 38 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
Manufacturer TypeAuthorized Distributor
CategoryImported Instrument
ModelQ-Sun Xe-3HSE
Xenon Lamp Power1800 W × 3
Irradiance Range0.55–1.3 W/m²/nm @ 340 nm
Light Exposure Cycle1–999 h
Humidity Range20–95% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQ-FOG CRH
Temperature Range20–60 °C (spray/soak), 20–70 °C (dry), 20–60 °C (RH)
Humidity ControlFully adjustable relative humidity (RH), 10–95% RH (CRH-specific capability)
Internal Solution Reservoir120 L
Chamber Capacity640 L (CRH-600) or 1103 L (CRH-1100)
Sample Capacity160 plates (75 × 150 mm) or 240 plates (75 × 150 mm)
Water Purity Requirement<8 ppm TDS, resistivity >50 kΩ·cm
Compressed Air4–10 bar (60–150 psi), max. 1.7 L/s (3.5 CFM)
Power Supply208–230 V, 50/60 Hz, up to 38 A
Weight (dry)333 kg (CRH-600), 378 kg (CRH-1100)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQ-Lab
OriginUSA
ModelQ-Sun Xe-3
Xenon Lamp Power3 × 1800 W
Irradiance Range0.55–1.3 W/m²/nm @ 340 nm
Light Exposure Cycle1–999 h
Humidity Range20–95% RH
Cooling MethodAir-cooled
Sample Tray Dimensions451 mm × 718 mm
Filter OptionsDaylight, Window Glass, Extended UV
Optional FeaturesFront/Rear Spray, Dual Spray (Secondary Liquid), Refrigerated Cooling (Xe-3-HSCE), SOLAR EYE Irradiance Control, NIST-Traceable Calibration