- All
- Favorite
- Popular
- Most rated
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Q-SUN® Xe-8 |
| Price | Upon Request |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | QUV |
| Irradiance Range | 0.48–0.95 W/m² @ 340 nm |
| Test Duration | 1–9999 hours (programmable) |
| UV Wavelength Range | 250–400 nm |
| Chamber Capacity | Up to 48 specimens (75 mm × 150 mm each) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-3 Series |
| Cooling Method | Air-cooled |
| Lamp Configuration | Three independent xenon arc lamps |
| Filter Options | Daylight, Window Glass, Extended UV |
| Irradiance Control | SOLAR EYE® broadband or narrowband (340 nm, 420 nm, TUV) |
| Black Panel Temperature Range | 42–120 °C |
| Chamber Air Temperature Range | 25–45 °C (dark cycle), 35–65 °C (light cycle) |
| Relative Humidity Control | Standard, 10–95% RH |
| Sample Tray Dimensions | 451 mm × 718 mm |
| Spray Options | Front spray, back spray, dual-fluid spray (e.g., acid rain, detergent solution) |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, ISO 11341, IEC 60068-2-9 |
| Calibration Traceability | NIST-traceable, ISO/IEC 17025 accredited (A2LA Cert. #2382-01, #2383-02, #2383-03) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-SUN Xe-1 |
| Xenon Lamp Power | Not specified (air-cooled single-lamp system) |
| Irradiance Control | SOLAR EYE broadband or narrowband (340 nm, 420 nm, or TUV) |
| Light Cycle | Programmable irradiance-on/off cycles with optional water spray and refrigeration |
| Dimensions (W×D×H) | 610 × 584 × 533 mm |
| Sample Tray | 251 × 457 mm (horizontal, flat), accommodates up to seventeen 51 × 102 mm specimens |
| Lamp Life | ~1500 hours (air-cooled xenon arc lamp) |
| Temperature Range | Black Panel: 35–103 °C |
| Air Temperature (with refrigeration option) | 19–103 °C |
| Calibration | NIST-traceable CT202 (temperature) and CR20 (irradiance) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH1100-HSC |
| Spray Mode | Continuous/Cyclic Spray |
| Temperature Range | 20–70 °C |
| Chamber Volume | 1103 L |
| Humidity Control | Full-Variable RH via Air Preconditioning System |
| Spray Function | Adjustable High-Flow Liquid Shower Module |
| Nozzle Maintenance | Automatic Self-Cleaning Mechanism |
| Internal Solution Reservoir | 120 L with Filtration & Low-Level Alarm |
| Compliance | GMW 14872, SAE J2334, ISO 11997, VW PV1210, Ford CETP, Renault D17 2025, JASO M609, GB/T 24135, Prohesion™ Protocol |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | QUV/se, QUV/spray |
| Irradiance Range | 0.48–0.95 W/m² @ 340 nm |
| Exposure Duration | 1–9999 hours (programmable) |
| UV Wavelength Range | 250–400 nm |
| Chamber Capacity | Up to 48 specimens (75 mm × 150 mm each) |
| Compliance | ASTM G154, ISO 4892-3, IEC 61215, SAE J2020, GB/T 14522, FDA 21 CFR Part 11 (software-enabled audit trail optional) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Xe-3HSE |
| Xenon Lamp Power | 1800 W × 3 |
| Irradiance Range | 0.55–1.3 W/m²/nm @ 340 nm |
| Light Exposure Cycle | 1–999 h |
| Humidity Range | 20–95% RH |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Qsun QUV |
| Irradiance Range | 0.48–0.95 W/m² |
| Exposure Duration | 1–9999 hours (adjustable per standard) |
| UV Wavelength Range | 250–400 nm |
| Chamber Capacity | Up to 48 specimens (75 mm × 150 mm each) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q-Sun Xe-3HBSE |
| Xenon Lamp Power | 3 × 1800 W |
| Irradiance Range | 0.55–1.3 W/m²/nm @ 340 nm |
| Light Exposure Cycle | 1–999 h |
| Humidity Range | 20–95% RH |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-SUN Xe-3 |
| Xenon Lamp Power | 1800 W × 3 |
| Irradiance Range | 0.55–1.3 W/m²/nm @ 340 nm |
| Light Exposure Cycle | 1–999 h |
| Humidity Range | 20–95% RH |
| Cooling Method | Air-cooled |
| Sample Tray Dimensions | 451 mm × 718 mm |
| Filter Options | Daylight, Window Glass, Extended UV |
| Optional Features | Front/Back Dual Spray, Refrigerated Chamber (Xe-3-HSCE), SOLAR EYE Irradiance Control, NIST-Traceable Calibration |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG SSP-600, Q-FOG SSP-1100, Q-FOG CCT-600, Q-FOG CCT-1100 |
| Temperature Range | 20–70 °C (spray/dry), 20–60 °C (RH/humidity) |
| Chamber Capacity | 640 L (SSP/CCT-600), 1103 L (SSP/CCT-1100) |
| Salt Solution Reservoir | 120 L |
| Sample Capacity | 160 panels (75 × 150 mm) for 600-series |
| Spray Rate | 1–2 mL/80 cm²·hr |
| Air Pressure | 0.7–1.0 kg/cm² (≈70–100 kPa) |
| Humidity Control | 95–100% RH (CCT models only) |
| Power Supply | 208–230 V, 50/60 Hz, 13–38 A |
| Weight (dry) | 224–378 kg |
| Water Purity Requirement | <8 ppm TDS, >50 kΩ·cm resistivity |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUV/se |
| Irradiance Range | 0.48–0.95 W/m² @ 340 nm |
| Exposure Time | Adjustable from 1 to 9999 hours |
| UV Wavelength Range | 250–400 nm |
| Chamber Capacity | Up to 48 specimens (75 mm × 150 mm each) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH-600 |
| Temperature Range | 20–60 °C (spray/soak), 20–70 °C (dry), 20–60 °C (RH) |
| Internal Chamber Volume | 640 L (incl. lid) |
| Salt Solution Reservoir | 120 L |
| Sample Capacity | 160 × 75 mm × 150 mm panels |
| RH Control Range | Fully adjustable 10–95% RH (CRH model only) |
| Compressed Air Requirement | 4–10 bar, ≤1.7 L/s |
| Deionized Water Specification | <8 ppm TDS, >50 kΩ·cm resistivity |
| Power Supply | 230 V ±10%, 50/60 Hz, 32 A single-phase |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | QUV/Spray |
| Irradiance Range | 0.48–0.95 W/m² @ 340 nm |
| Test Duration | Adjustable from 1 to 9999 hours |
| UV Wavelength Range | 250–400 nm |
| Chamber Capacity | Up to 48 specimens (75 mm × 150 mm each) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT SSP CRH |
| Temperature Range | 20–60 °C (spray/soak), 20–70 °C (dry), 20–60 °C (RH/humidity) |
| Chamber Capacity | 640 L (CCT-600/SSP-600/CRH-600) or 1103 L (CCT-1100/SSP-1100/CRH-1100) |
| Internal Salt Solution Reservoir | 120 L |
| Sample Rack Capacity | 160 pcs (75 mm × 150 mm) for 600-series |
| Relative Humidity Control | 95–100% RH (CCT), fully adjustable 10–95% RH (CRH) |
| Air Pressure Requirement | 3–10 bar |
| Water Purity | <8 ppm TDS, resistivity >50 kΩ·cm |
| Power Supply | 208–230 V, 50/60 Hz, up to 38 A |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | Q-Sun Xe-3HSE |
| Xenon Lamp Power | 1800 W × 3 |
| Irradiance Range | 0.55–1.3 W/m²/nm @ 340 nm |
| Light Exposure Cycle | 1–999 h |
| Humidity Range | 20–95% RH |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CRH |
| Temperature Range | 20–60 °C (spray/soak), 20–70 °C (dry), 20–60 °C (RH) |
| Humidity Control | Fully adjustable relative humidity (RH), 10–95% RH (CRH-specific capability) |
| Internal Solution Reservoir | 120 L |
| Chamber Capacity | 640 L (CRH-600) or 1103 L (CRH-1100) |
| Sample Capacity | 160 plates (75 × 150 mm) or 240 plates (75 × 150 mm) |
| Water Purity Requirement | <8 ppm TDS, resistivity >50 kΩ·cm |
| Compressed Air | 4–10 bar (60–150 psi), max. 1.7 L/s (3.5 CFM) |
| Power Supply | 208–230 V, 50/60 Hz, up to 38 A |
| Weight (dry) | 333 kg (CRH-600), 378 kg (CRH-1100) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-Sun Xe-3 |
| Xenon Lamp Power | 3 × 1800 W |
| Irradiance Range | 0.55–1.3 W/m²/nm @ 340 nm |
| Light Exposure Cycle | 1–999 h |
| Humidity Range | 20–95% RH |
| Cooling Method | Air-cooled |
| Sample Tray Dimensions | 451 mm × 718 mm |
| Filter Options | Daylight, Window Glass, Extended UV |
| Optional Features | Front/Rear Spray, Dual Spray (Secondary Liquid), Refrigerated Cooling (Xe-3-HSCE), SOLAR EYE Irradiance Control, NIST-Traceable Calibration |
Show next