| Origin | USA |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model | 3010 |
| Conductivity Range | 0.01 µS/cm to 200.0 mS/cm |
| TDS Range | 0.0–80.0 ppt |
| Resistivity Range | 0.01 µS/cm to 200.0 mS/cm (inverted scale) |
| Salinity Range | 0.0–80.0 ppt |
| Temperature Range | −10.0 to 120.0 °C |
| Accuracy | ±0.5% of full scale (FS) for conductivity |
| Minimum Resolution | 0.01 µS/cm (at low range) |
| Electrode Constants Supported | 0.1, 1.0, and 10.0 cm⁻¹ |
| Temperature Compensation | Automatic (NTC 10 kΩ thermistor), user-adjustable α (0.00–4.00 %/°C) and reference temperature (15.0–25.0 °C) |
| TDS Factor | Adjustable (0.30–1.00) |
| Calibration Memory | Yes |
| Power Supply | 9 V alkaline battery (IEC 6LR61) |
| Operating Environment | 0–50 °C, <90% RH |
| Weight | ~260 g |
| Dimensions | 186 × 70 × 37 mm |
| Certifications | CE compliant |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-BX |
| Portability | Handheld |
| Application Environment | Laboratory & Field |
| Brix Range | 0.0–90.0% |
| Salt (NaCl) Range | 0.00–15.00% |
| Brix Accuracy | ±0.2% |
| Salt Accuracy | 0.00–0.99%: ±0.05% |
| 1.00–9.99% | ±5% (relative) |
| 10.00–15.00% | ±10% (relative) |
| Brix Resolution | 0.1% |
| Salt Resolution | 0.01% |
| Temperature Compensation Range | Brix: 10–100°C |
| Salt | 10–40°C |
| Measurement Principle | Optical Refraction (Brix), Conductivity (Salt) |
| Compliance | ISO 2173, AOAC 932.12, ASTM D1074 |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 3173/3173R |
| Detection Parameter | Conductivity Only (Multi-Parameter Output) |
| Portability | Benchtop |
| Application Environment | Industrial Process Monitoring & Laboratory QC |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Temperature Range | 10–110 °C |
| Accuracy | ±0.5% of Full Scale |
| Minimum Resolution | 0.001 µS/cm |
| Auto Temperature Compensation | Yes |
| Power Supply | AC/DC Dual Mode |
| Data Interface | RS-232C (3173R only) |
| Memory | Calibration Value Retention After Power Loss |
| Display | Large LCD with Multi-Parameter Simultaneous Readout |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Model | 3010M |
| Measurement Parameters | Conductivity, TDS, Salinity, Temperature |
| Portability | Handheld (Field-Portable) |
| Intended Use | Industrial Process Monitoring, Field Sampling, Lab Bench Support |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Temperature Range | 10–110 °C |
| Accuracy | ±0.5% of Full Scale |
| Minimum Resolution | 0.001 µS/cm |
| Electrode Constant Options | 0.1, 1.0, 10.0 cm⁻¹ |
| Temperature Compensation | Automatic (NTC 30 kΩ) |
| Enclosure Rating | IP67 (Waterproof) |
| Data Retention | Non-volatile memory retains calibration and settings after power loss |