| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI981037 |
| Application | Dermatological pH Measurement on Stratum Corneum and Scalp Surface |
| Compliance | CE-marked, ISO 13485–certified manufacturing environment |
| Calibration | Factory-calibrated with traceable NIST-standard buffer certificates |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI98165 Portable pH/mV/Temperature Meter with Integrated Stainless Steel pH Electrode for Cheese Production |
| pH Range | -2.000 to 20.000 |
| mV Range | ±2000.0 |
| Temperature Range | -20.0 to 120.0 °C |
| Calibration | Up to 5-point auto-recognize + 5-point custom calibration |
| Built-in Standards | 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH |
| Resolution | 0.001 pH / 0.1 mV / 0.1 °C |
| Accuracy | ±0.002 pH / ±0.2 mV / ±0.4 °C |
| Electrode | FC2423 conical-tip stainless steel pH electrode with integrated Pt1000 temperature sensor |
| Data Logging | 200 records (100 pH + 100 mV) |
| Interface | USB (HI92000-15 software compatible) |
| Protection | IP67 |
| Power | 4×AAA batteries (BEPS low-battery warning) |
| Auto-off | Configurable (5/10/30/60 min or off) |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI98163 |
| pH Range | −2.000 to 20.000 |
| mV Range | ±2000.0 |
| Temperature Range | −20.0 to 120.0 °C |
| Resolution | 0.001 pH / 0.1 mV / 0.1 °C |
| Accuracy | ±0.002 pH / ±0.2 mV / ±0.4 °C |
| Calibration | Up to 5-point auto-recognizing + 5-point custom calibration with 7 built-in buffer points (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH) |
| Electrode | FC2323 conical-tip PVDF-body pH electrode with integrated amplifier and NTC temperature sensor, stainless-steel blade tip, DIN waterproof connector, 1 m cable |
| Data Logging | 200 records (100 pH + 100 mV) |
| Interface | USB (HI92000-15 software compatible) |
| IP Rating | IP67 |
| Power | 4 × AAA batteries (1.5 V), BEPS low-battery warning |
| Auto-off | Configurable (5/10/30/60 min or disabled) |
| Dimensions | 185 × 93 × 35.2 mm |
| Weight | 400 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI981034 |
| Application | Dedicated pH measurement for raw, pasteurized, and UHT milk and dairy products |
| Calibration | Automatic 1- or 2-point calibration with buffer recognition |
| Electrode Type | Integrated, food-grade, conical-tip pH electrode with built-in temperature sensor (ATC) |
| IP Rating | IP67 dust- and water-resistant housing |
| Power | 4 × AAA batteries (approx. 200 hours continuous use) |
| Display | Large LCD with backlight, dual-level pH and temperature readout |
| Compliance | Designed to meet ISO 5725 (accuracy/repeatability), AOAC Official Method 987.04 (milk pH), and FDA Grade A Pasteurized Milk Ordinance (PMO) Annex G requirements |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI98164 |
| pH Range | –2.000 to 20.000 |
| mV Range | ±2000.0 |
| Temperature Range | –20.0 to 120.0 °C |
| Resolution | 0.001 pH / 0.1 mV / 0.1 °C |
| Accuracy | ±0.002 pH / ±0.2 mV / ±0.4 °C |
| Calibration | Up to 5-point auto-recognizing and 5-point user-defined, with 7 built-in NIST-traceable buffer points |
| Electrode | FC2133 conical-tip pH electrode with integrated amplifier and PT1000 temperature sensor |
| Data Logging | 200 records (100 pH + 100 mV) |
| Interface | USB (HI92000-15 software compatible) |
| Protection Rating | IP67 |
| Power | 4×AAA batteries (BEPS low-battery warning) |
| Auto-off | Configurable (5/10/30/60 min or disabled) |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI98191 |
| pH Range | -2.000 to 20.000 |
| ORP Range | ±2000 mV |
| ISE Range | 1.00 × 10⁻⁷ to 9.99 × 10¹⁰ (unit-dependent) |
| Temperature Range | -20.0 to 120.0 °C |
| Resolution | 0.001 pH / 1 mV / 0.01–10 concentration units |
| Accuracy | ±0.002 pH / ±0.2 mV / ±0.5% (monovalent), ±1% (divalent) ISE |
| Calibration | Up to 5-point auto-recognizing pH |
| Temperature Compensation | Automatic or manual (-20.0 to 120.0 °C) |
| Electrode | HI72911B integrated temperature-sensing titanium-body flat-tip pH electrode (BNC, 1 m cable) |
| Data Storage | 300 records (100 pH/mV/ISE sets) |
| GLP Compliance | Date/time-stamped calibration logs, slope/offset tracking |
| Ingress Protection | IP67 |
| Display | Backlit graphical LCD with on-screen guidance |
| Interface | USB (HI92000-15 software compatible) |
| Power | 4 × AAA batteries (auto-off configurable: 5/10/30/60 min or off) |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI991003 |
| pH Range | -2.00 to 16.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| ORP Range | ±1999 mV |
| ORP Resolution | 1 mV |
| ORP Accuracy | ±0.2 mV |
| Temperature Range | -20.0 to 120.0°C |
| Temp Resolution | 0.1°C |
| Temp Accuracy | ±0.5°C (≤60°C), ±1.0°C (>60°C) |
| Calibration | Auto-recognizing 1–2 point with dual built-in buffer sets (pH 4.01/7.01/10.01 and 4.01/6.86/9.18) |
| Temperature Compensation | Automatic (-5.0 to 105.0°C) |
| Electrode | HI1297D stainless steel body pH/ORP/ATC combination probe |
| Power | 3 × 1.5 V AAA batteries |
| IP Rating | IP67 (dust-tight, immersion up to 1 m for 30 min) |
| Dimensions | 152 × 58 × 30 mm |
| Weight | 205 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI6221 Advanced Benchtop pH/ORP Meter |
| Display | 7.0-inch full-color TFT touchscreen |
| pH Range | –2.000 to 20.000 |
| pH Resolution | 0.001 |
| pH Accuracy | ±0.002 |
| ORP Range | ±2000.0 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.2 mV |
| Temperature Range | –20.0 to 120.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C |
| Calibration | Up to 5-point pH auto-recognition (NIST, DIN, USA buffers), 1-point ORP offset |
| Electrode Input | BNC + mini-DIN (for integrated temperature sensor) |
| Data Storage | 4000 measurement records with timestamp, electrode ID, and calibration history |
| Connectivity | USB-B, optional Bluetooth 5.0 module (HI7698280) |
| Power | AC adapter (100–240 VAC) or rechargeable Li-ion battery (up to 200 h operation) |
| Compliance | CE, RoHS, IP54 enclosure rating |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI98167 |
| Application-Specific Design | Beer & Breweries |
| Temperature Compensation | Automatic (ATC) |
| Calibration | Up to 3-point (pH 2.01, 4.01, 7.01 or custom buffers) |
| Logging Capacity | 200 data sets with timestamp and temperature |
| Compliance | GLP-compliant data logging with calibration history and instrument settings |
| Display | Backlit LCD with dedicated beer-specific icons (e.g., “Beer pH”, “ATC”, “Cal”, “Log”, “RCL”, “MS”) |
| Electrode Interface | Built-in FC202B stainless-steel body pH electrode with conical tip and food-grade PVDF body |
| IP Rating | IP67 waterproof and dustproof |
| Power | 4 × AAA batteries (approx. 200 hours operation) |
| Operating Temperature | 0 to 50 °C |
| Storage Temperature | -20 to 60 °C |
| Dimensions | 160 × 80 × 38 mm |
| Weight | 250 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI981033 |
| Power Source | CR2032 3V lithium battery |
| Certification | CE marked |
| Intended Use | pH measurement in food, beverages, and dietary supplements |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI5222 |
| Measurement Modes | pH, ORP, ISE (single-ion concentration), Temperature (°C) |
| Display | 7-inch full-color touchscreen |
| Input Channels | Dual BNC + dual reference input |
| Calibration | Up to 5-point pH, 3-point ORP, 5-point ISE (non-linear) |
| Data Storage | 4000 measurement records with timestamp, user ID, and electrode ID |
| Connectivity | USB-A, USB-B, RS232, optional Ethernet |
| Compliance | CE, RoHS, ISO/IEC 17025 compatible operation environment |
| Power | 100–240 VAC, 50/60 Hz |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI98161 Portable pH/mV/°C Meter (Food Industry Optimized) |
| pH Range | -2.000 to 20.000 |
| mV Range | ±2000.0 |
| Temperature Range | -20.0 to 120.0 °C |
| Calibration | Up to 5-point auto-recognizing + 5-point custom calibration |
| Built-in Standards | 7 buffer points (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH) |
| Resolution | 0.001 pH / 0.1 mV / 0.1 °C |
| Accuracy | ±0.002 pH / ±0.2 mV / ±0.4 °C |
| Electrode | FC2023 PVDF-body pH electrode with integrated amplifier and NTC temperature sensor |
| Connectivity | USB interface (HI92000-15 software compatible) |
| Data Storage | 200 records (100 pH + 100 mV) |
| IP Rating | IP67 |
| Power | 4×AAA batteries (BEPS low-battery warning) |
| Auto-off | Configurable (5/10/30/60 min or disabled) |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI2002 |
| pH Range | -2.000 to 16.000 |
| pH Resolution | 0.001 / 0.01 |
| pH Accuracy | ±0.002 / ±0.01 |
| mV Range (pH-mV) | ±1000 mV |
| ORP Range | ±2000 mV |
| mV Resolution/Accuracy | 0.1 mV / ±0.2 mV (±999.9 mV), ±1 mV (±2000 mV) |
| Temperature Range | -20.0 to 120.0 °C |
| Temp Resolution/Accuracy | 0.1 °C / ±0.5 °C |
| Calibration | Up to 5-point auto-recognizing pH, single-point ORP |
| Data Storage | 1000 auto, 200 interval, 600 manual |
| Interface | micro-USB + USB-A |
| Power | Rechargeable Li-ion battery with 5 V adapter |
| Dimensions | 202 × 140 × 12 mm |
| Weight | 250 g |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI98120 |
| Measurement Parameters | ORP (mV) and Temperature (°C) |
| Accuracy | ±2 mV (ORP), ±0.5 °C (Temperature) |
| Resolution | 1 mV / 0.1 °C |
| Electrode Type | Integrated ORP/Temperature Combination Sensor |
| Calibration | Single-point offset calibration (using standard ORP buffer) |
| IP Rating | IP67 |
| Power | 4 × 1.5 V AAA batteries (approx. 200 hours continuous use) |
| Operating Environment | 0 to 50 °C, max. 95% RH non-condensing |
| Compliance | CE, RoHS |
| Brand | Hanna Instruments |
|---|---|
| Origin | Italy |
| Model | HI98162 Portable pH/mV/°C Meter (Dairy-Specific) |
| pH Range | -2.000 to 20.000 pH |
| mV Range | ±2000.0 mV |
| Temperature Range | -20.0 to 120.0 °C |
| Resolution | 0.001 pH / 0.1 mV / 0.1 °C |
| Accuracy | ±0.002 pH / ±0.2 mV / ±0.4 °C |
| Calibration | Up to 5-point auto-recognize + 5-point custom calibration |
| Electrode | FC1013 refillable spherical PVDF pH electrode with integrated amplifier and NTC temperature sensor |
| IP Rating | IP67 |
| Data Logging | 200 records (100 pH + 100 mV) |
| Interface | USB (HI92000-15 software compatible) |
| Power | 4×AAA batteries with BEPS low-battery warning and programmable auto-off (5/10/30/60 min or off) |