Spectroscopy Instruments
Filter
Showing 1–30 of 1315 results
| Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Mode Flame/GF-AAS |
| Monochromator | Plane Grating (1800 lines/mm) |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Reversal Full-Wavelength Correction |
| Resolution | ≤0.2 nm |
| Sensitivity | 0.0044 µg/mL for Cu (Abs = 1) |
| Detection Limit | 0.001 µg/mL for Cu (3σ) |
| Precision (RSD) | ≤0.5% (n=10) |
| Atomization Modes | Flame + Electrothermal Graphite Furnace |
| Auto-Switch Time | <2 s between modes |
| Safety Systems | Integrated gas pressure monitoring, flame failure detection, graphite furnace overtemperature cutoff, hollow cathode lamp current regulation, and argon flow supervision |
| Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace Atomic Absorption Spectrometer |
| Monochromator | Plane Grating (1800 lines/mm) |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Reversal (SR) Method |
| Resolution | <0.2 nm (at 250 nm) |
| Sensitivity | 0.0044 Abs for 1 µg/mL Cu (i.e., ~5 ppm Cu solution yields ~1.0 Abs) |
| Precision (RSD) | ≤0.5% (n=10, typical for flame mode) |
| Detection Limit (Flame) | 0.002 µg/mL Cu |
| Detection Limit (Graphite Furnace) | 0.005 pg for Cd |
| Atomization Options | Integrated Flame & Graphite Furnace with <2 s Switching |
| Optional Accessories | HG-01 Ceramic Hydride Generator, GF Autosampler, N₂O/C₂H₂ High-Temperature System |
| Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | AA-7095 Atomic Absorption Spectrometer |
| Pricing | Upon Request |
| Light Source Configuration | 8-lamp turret with simultaneous preheating |
| Spectral Bandwidth Options | 0.1, 0.2, 0.4, 0.7, 1.0, and 2.0 nm (6-step automated slit selection) |
| Background Correction | Dual-mode — longitudinal AC Zeeman effect + D₂ lamp |
| Auto-Optimization Functions | Automated zeroing, wavelength scanning, hollow cathode lamp positioning, mirror alignment, and energy balancing |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AnalyzeIT Wet Process Analyzer |
| Price Range | USD 140,000 – 280,000 (based on CIF terms) |
| Instrument Principle | Fourier Transform Near-Infrared (FT-NIR) Spectroscopy |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | FTPA2000-260 |
| Type | Online Analyzer |
| Principle | Fourier Transform (FT) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Spectral Resolution | 1–128 cm⁻¹ (in 2× steps) |
| Optical Path Difference (OPD) Scan Speed | 1 cm/s |
| Wavenumber Repeatability | 0.002 cm⁻¹ RMS @ 7300 cm⁻¹ |
| Wavenumber Reproducibility | 0.04 cm⁻¹ RMS @ 7300 cm⁻¹ |
| Absorbance Linearity Error | ≤0.1% of peak response |
| SNR (1 scan, 16 cm⁻¹, room-temp InGaAs) | ≥15,000:1 (29 µabs @ 0 abs) |
| Sampling Modes | Transmission / Diffuse Reflectance / Transflectance |
| Detector Options | Thermoelectrically Cooled InAs or InGaAs |
| Channel Count | 8 independent optical channels (8-in/8-out) |
| Fiber Interface | SMA-905 |
| Fiber Types | Low-OH silica core (300–600 µm), multi-fiber bundle (650 µm, NA 0.22–0.28) |
| Max Fiber Length | 100 m (solids), 300 m (liquids) |
| Software | Horizon MB, FTSW100 |
| Compliance | FDA 21 CFR Part 11, GMP/GLP-ready, OPC, Modbus TCP |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | FTPA2000-PH40 |
| Instrument Type | Online |
| Principle | Fourier Transform (FT) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Spectral Sampling Interval | < 0.7 cm⁻¹ |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | FTSW100, Horizon MB |
| Optical Path Difference (OPD) Scan Speed | 1 cm/s |
| Resolution Options | 1–128 cm⁻¹ (in powers of two) |
| Wavenumber Repeatability | 0.002 cm⁻¹ RMS @ 7300 cm⁻¹ |
| Wavenumber Reproducibility | 0.04 cm⁻¹ RMS @ 7300 cm⁻¹ |
| Absorbance Linearity | ±0.1% of peak response |
| SNR (1 scan, 16 cm⁻¹, room temp) | ≥15,000:1 (extended InGaAs detector) |
| Long-term Spectral Stability | ≤2%/°C drift (4000–10000 cm⁻¹) |
| Beam Splitter Material | BK7 optical glass |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB-Rx |
| Instrument Type | In-situ, Real-time FTIR Spectrometer |
| Spectral Range | 600–8000 cm⁻¹ (configurable by probe/fiber combination) |
| Resolution | Adjustable from 1 cm⁻¹ to 64 cm⁻¹ (in 2 cm⁻¹ increments) |
| Scan Speed | Variable, dependent on resolution and scan count |
| Signal-to-Noise Ratio | 50,000:1 (60 s acquisition, 4 cm⁻¹ resolution) |
| Detector | Uncooled Room-Temperature Pyroelectric (DTGS) |
| ATR Probe Materials | Hastelloy® C-276, ZnSe, Diamond, ZrO₂ |
| Fiber Types | Silver Halide (AgClBr), Sulfide Glass |
| Spectral Digitization | 24-bit ADC |
| Detection Limit | 0.1% w/w acetone in toluene (60 s, 4 cm⁻¹) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB3000 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 490–8500 cm⁻¹ |
| Resolution | Adjustable from 1 to 64 cm⁻¹ (2× step increments) |
| Signal-to-Noise Ratio | 50,000:1 (60 s acquisition, 4 cm⁻¹ resolution) |
| Detector | DTGS |
| Beam Splitter | ZnSe |
| Interferometer | Dual-pivot Michelson with high-throughput optical design |
| Laser Source | Solid-state laser |
| ADC Resolution | 24-bit |
| Wavenumber Accuracy | < 0.01 cm⁻¹ (@1918 cm⁻¹) |
| Wavenumber Repeatability | < 0.001 cm⁻¹ (@1918 cm⁻¹) |
| Short-term Stability | < 0.09 % |
| Temperature Stability | < 1 %/°C |
| Power Consumption | 65 W |
| Dimensions | 435 × 280 × 372 mm |
| Weight | 24 kg |
| Compliance | CSA, RoHS, CE |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB3600-CH10 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Near-Infrared (FT-NIR) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Data Sampling Interval | < 0.7 cm⁻¹ |
| Measurement Mode | Transmission |
| Chemometrics Software | Horizon MB |
| Compliance | AOCS Cd 1e-01 (IV determination) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB3600-CH20 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Near-Infrared (FT-NIR) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Data Sampling Interval | < 0.7 cm⁻¹ |
| Measurement Mode | Transmission |
| Chemometrics Software | Horizon MB |
| Compliance | Designed for GLP/GMP-aligned workflows, supports ASTM E1655 and ISO 12099 data handling conventions |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB3600-CH80 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Near-Infrared (FT-NIR) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Data Sampling Interval | < 0.7 cm⁻¹ |
| Measurement Mode | Transmission |
| Chemometrics Software | Horizon MB |
| Sample Throughput | Non-destructive, sub-10-second analysis per PET container |
| Calibration Basis | Pre-installed quantitative models derived from >150 real-world PET bottle measurements |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MB3600-HP10 |
| Instrument Type | Laboratory |
| Principle | Fourier Transform Near-Infrared (FT-NIR) Spectroscopy |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Data Sampling Interval | < 0.7 cm⁻¹ |
| Measurement Mode | Transmission |
| Chemometrics Software | Horizon MB |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB3600-PH |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform |
| Spectral Range | 3800–14000 cm⁻¹ |
| Spectral Resolution | Adjustable from 1 to 64 cm⁻¹ (step size: 2 cm⁻¹), nominal resolution < 0.7 cm⁻¹ |
| Signal Sampling | 24-bit ADC |
| SNR (60 s, 16 cm⁻¹, peak response) | >100,000:1 (DTGS), >600,000:1 (Extended InGaAs) |
| Frequency Accuracy (@ 7300 cm⁻¹) | < 0.06 cm⁻¹ |
| Frequency Reproducibility (@ 7300 cm⁻¹) | < 0.006 cm⁻¹ |
| Absorbance Reproducibility (methanol reference) | < 0.002 AU |
| Short-term Stability (@ 8000 cm⁻¹) | < 0.09 % |
| Temperature Stability (@ 8000 cm⁻¹) | < 1 %/°C |
| Sampling Modes | Transmission, Diffuse Reflectance, Fiber-Optic Probe |
| Software | Horizon MB Chemometrics Suite |
| Regulatory Compliance | 21 CFR Part 11, cGMP IQ/OQ Protocols Included |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MR-i |
| Price | USD 2,000,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MR304/170 |
| Instrument Type | Fourier Transform Infrared Spectrometer |
| Spectral Resolution | Adjustable up to 1 cm⁻¹ |
| Data Interface | 100 Mbps Ethernet |
| Scan Speed | ≥83 Hz (12 ms per interferogram) |
| Field of View Options | 5 mrad, 28 mrad, 75 mrad |
| NESR | <1.0 × 10⁻⁹ W·cm⁻²·sr⁻¹·cm |
| Compliance | ASTM E1421, ISO 18356, MIL-STD-461G (EMC), GLP/GMP-ready data audit trail |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | PIR3502, PFO3372, PUV3402 |
| Operating Principle | In-situ, Online & Portable |
| Spectral Ranges | UV (190–400 nm), VIS (400–700 nm), NIR (700–2500 nm), IR (2.5–25 µm) |
| Wavelength Channels | Up to 8 discrete optical bands |
| Integration | Compatible with VN2300 Analyzer Network |
| Sampling Interface | Direct path (PIR3502/PUV3402) and fiber-optic probe (PFO3372) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | TALYS ASP500-OH |
| Instrument Type | Online |
| Principle | Fourier Transform Near-Infrared (FT-NIR) Spectroscopy |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Detector Options | InGaAs 2.1 (4550–10500 cm⁻¹), InGaAs 2.1 TE-cooled (4750–10500 cm⁻¹), InGaAs 2.6 (4000–10000 cm⁻¹) |
| Light Source | Quartz Halogen Lamp with Electronic Stabilization |
| Laser Reference | Solid-State Laser |
| Spectral Resolution (Adjustable) | 1–64 cm⁻¹ |
| Wavenumber Reproducibility (@7300 cm⁻¹) | <0.006 cm⁻¹ |
| Wavenumber Accuracy (@7300 cm⁻¹) | <0.06 cm⁻¹ |
| Sampling Modes | Transmission, Diffuse Reflectance, Transflectance |
| Data Sampling Interval | Better than 0.7 cm⁻¹ |
| Software Suite | Horizon MB, Quantify, PLSPlus, PLS-IQ, Unscrambler |
| Communication Protocols | Modbus TCP (Ethernet), RS232/RS485 (via converter), OPC DA (Ethernet), CANopen (via USB-to-CAN adapter) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | TALYS ASP500-Oleochemicals |
| Instrument Type | Online |
| Principle | Fourier Transform (FT) |
| Wavelength Range | 3800–14000 cm⁻¹ |
| Detector Options | InGaAs 2.1 (4550–10500 cm⁻¹), InGaAs 2.1 TE-cooled (4750–10500 cm⁻¹), InGaAs 2.6 (4000–10000 cm⁻¹) |
| Light Source | Quartz Halogen Lamp with Electronic Stabilization |
| Interferometer | Solid-State Laser Referenced |
| Spectral Resolution (Adjustable) | 1–64 cm⁻¹ |
| Wavenumber Reproducibility (@7300 cm⁻¹) | <0.006 cm⁻¹ |
| Wavenumber Accuracy (@7300 cm⁻¹) | <0.06 cm⁻¹ |
| Sampling Modes | Transmission, Diffuse Reflectance, Transflectance |
| Data Sampling Interval | Better than 0.7 cm⁻¹ |
| Communication Protocols | Modbus TCP (Ethernet), RS232/RS485 (via converter), OPC DA (Ethernet), CANopen (via USB-to-CAN adapter) |
| Chemometrics Software | Horizon MB, Quantify, PLSPlus, PLSIQ, Unscrambler |
| Brand | Ability Technology |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | LTP-ICP-OES |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit (As, Sb, Pb, Sn, Se, Hg, Cd) | <1 µg/L |
| Repeatability (RSD) | ≤5.0% |
| Stability (RSD, 4h) | ≤5.0% |
| Wavelength Range | 200–350 nm |
| Optical Resolution | ≤1.35 nm |
| Brand | Abner |
|---|---|
| Origin | Jiangsu, China |
| Model | ABN-HRAM-001 |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 200–3100 cm⁻¹ |
| Resolution | 6 cm⁻¹ (@25 μm grating) |
| Laser Wavelength | 785 ± 0.5 nm |
| Laser Linewidth | ≤0.08 nm |
| Max Laser Power | 500 mW (software-adjustable) |
| Integration Time | 1 ms – 65 s |
| Detector | 16 MP high-sensitivity CMOS |
| Working Distance | 7.5 mm |
| Dimensions | 183 × 89 × 36 mm |
| Weight | ~500 g |
| Display | 5.72″ industrial capacitive touchscreen |
| Protection Rating | IP66 |
| Drop Resistance | 1.2 m |
| Operating Temperature | 0–45 °C |
| Operating Humidity | 5–80 % RH |
| Connectivity | Wi-Fi, Bluetooth, GPS, NFC |
| Interface | USB Type-C |
| Brand | Abner |
|---|---|
| Origin | Jiangsu, China |
| Model | ABN-SPEC-001 |
| Focal Length | 500 mm |
| Relative Aperture | f/8 |
| Spectral Range (with 600 g/mm grating) | 300–1100 nm |
| Extended Range (with grating exchange) | 150 nm–40 µm |
| Grating Size | 68 mm × 68 mm |
| Max. Installed Gratings | 3 |
| Flat-Field Focal Plane | 30 mm × 12 mm |
| Wavelength Accuracy | ±0.30 nm |
| Wavelength Repeatability | ±0.01 nm |
| Spectral Dispersion (@500 nm) | 1.5 nm/mm |
| Magnification | 1.0 |
| Output Port | Single exit slit |
| Scanning Speed | 150 nm/sec |
| Minimum Step Size | 0.01 nm |
| Interface | High-Speed USB |
| Dimensions (L×W×H) | 530 × 327 × 218 mm |
| Stray Light Level | <1×10⁻⁵ |
| Brand | Admesy |
|---|---|
| Origin | Netherlands |
| Model | CS2000 |
| Luminance Range | 0.003–300 cd/m² |
| Contrast Ratio Measurement Capability | Up to 100,000:1 |
| Spectral Bandwidth (FWHM) | 5 nm |
| Polarization Error | ≤2% (at 1° field of view) |
| Measurement Angles | 1°, 0.2°, 0.1° |
| Minimum Measurable Spot Size | Ø0.1 mm (with close-up lens) |
| Measurement Time at 1 cd/m² (Fast Mode) | ~5 s |
| Warm-up Time | 30 s |
| Operating Temperature | 5–35 °C |
| Compliance | JIS Z 8724-1997, CIE 122-1996 |
| Brand | Advanced Fiber Tools |
|---|---|
| Origin | Germany |
| Detector Type | CMOS |
| Spectral Range | 1500–2600 nm |
| Resolution | 2300 |
| Sensitivity | 2000 |
| Core Material | Low-OH Fused Silica |
| Cladding Material | Fluorinated Fused Silica |
| Coating Options | Acrylate (−40°C to +85°C), Silicone (−40°C to +180°C), Polyimide (−190°C to +385°C) |
| Numerical Aperture | 0.22 ± 0.02 |
| Core/Clad Ratio | 1.1, 1.2, or 1.4 |
| Biocompatibility | ISO 10993-compliant |
| Sterilization Compatibility | ETO, Steam, Electron Beam, Gamma |
| Radiation & Laser Damage Resistance | Yes |
| Brand | Advantest |
|---|---|
| Origin | Japan |
| Model | TAS7500 Series |
| Frequency Range | 0.03–7 THz (configurable bands: 0.03–2 THz, 0.1–4 THz, 0.5–7 THz) |
| Spectral Stability | ±0.2% energy repeatability |
| Measurement Modes | Transmission, Reflection, ATR, Polarization-Resolved |
| Environmental Operation | Dry-air purged optics enclosure |
| Form Factor | Benchtop |
| Pump Source | Ultrafast Fiber Laser (1550 nm) |
| Detection | Photoconductive Antenna Array |
| Imaging Capability | 2D THz mapping (amplitude/phase), layer thickness & density profiling |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments, supports GLP audit trails via software logging |
| Brand | AdvR |
|---|---|
| Origin | USA |
| Type | Fiber-Coupled Electro-Optic Phase Modulator |
| Wavelength Range | 397–1064 nm |
| Max. Optical Input Power | 1 W |
| Modulation Bandwidth | Up to 10 GHz |
| Insertion Loss | ≤ 5 dB |
| Half-Wave Voltage (Vπ) | 3–8 V (wavelength-dependent) |
| Polarization-Maintaining Fiber | PM400, PM480, PM630, PM780, PM850, PM980 |
| Compliance | RoHS, CE, ISO 9001-certified manufacturing |
| Brand | AECC (Aviation Engine Corporation of China) |
|---|---|
| Origin | Beijing, China |
| Model | LPG-2000 |
| Light Source | DC-pulsed hollow cathode discharge (low-pressure) |
| Optical Chamber | Evacuated vacuum chamber |
| Wavelength Range | 170–430 nm |
| Grating | Holographic concave grating, focal length 750 mm, 2400 grooves/mm |
| Spectral Resolution | < 0.024 nm |
| Detector | Hamamatsu high-sensitivity, low-noise photomultiplier tube (PMT) |
| Elemental Coverage | Ag, As, Au, B, Ba, Be, Bi, Ca, Cd, Ce, Cu, Ga, Ge, Hg, In, La, Mg, Mn, P, Pb, Pd, Pt, Rh, Ru, Sb, Se, Si, Sn, Sr, Te, Tl, Y, Zn, Zr (including sub-190 nm lines for B and P) |
| Detection Limits | 1×10⁻⁵% to 1×10⁻⁷% (e.g., Bi ≤ 0.00001%, As ≤ 0.0005%, P ≤ 0.001%, B ≤ 0.001%) |
| Precision | RSD < 20% for 10 replicate excitations on homogeneous samples |
| Temperature Control | Thermostabilized optical chamber, ±0.1 °C stability |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AFX1000-IR |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Deployment Mode | Ground-based & UAV-mounted |
| Spectral Range | 400–1000 nm (HSI) + 8–14 µm (LWIR) |
| Thermal Imaging Resolution | 640 × 512 pixels (full-frame radiometric temperature mapping) |
| Frame Acquisition Rate | ≥300 Hz (full spectral cube acquisition) |
| Total Field of View (TFOV) | 30.5° |
| Instantaneous Field of View (IFOV) | 2.7 mrad |
| RGB Camera | 26 MP synchronized capture |
| System Mass | <2.5 kg |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AFX1700-IR |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based and UAV-mounted |
| Spectral Range | 900–1700 nm (VNIR/SWIR HSI) + 8–14 µm (LWIR thermal) |
| Thermal Spatial Resolution | 640 × 512 pixels (full-frame radiometric temperature mapping) |
| Maximum Data Acquisition Rate | ≥500 Hz across full spectral bands |
| Total Field of View (TFOV) | 35.5° |
| Instantaneous Field of View (IFOV) | 3.5 mrad |
| RGB Camera Resolution | 26 MP |
| System Mass | <2.5 kg |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Hyper-Cam |
| Pricing | Available Upon Request |
| Operating Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Imaging Architecture | Dispersive (Grating-Based) |
| Deployment Mode | Ground-Based & Airborne Compatible |
| Spectral Range | 7.7–12.5 µm (MWIR) |
| Spectral Resolution | Up to 0.25 cm⁻¹ |
| Spatial Resolution (IFOV) | 0.45 mrad (typical, lens-dependent) |
| Detector Format | 320 × 256 HgCdTe FPA |
| Field of View (TFOV) | 6.4° × 5.1° |
| Frame Rate | Up to 60 Hz (full-frame, binning-dependent) |
| Calibration | Onboard Blackbody + Ambient Reference |
| Compliance | ISO/IEC 17025-aligned calibration traceability, GLP-compliant data acquisition workflow |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | RedEdge-P |
| Pricing | Available Upon Request |