| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | V-1800 |
| Detector Type | Silicon Photodiode |
| Wavelength Range | 320–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Display | 128×64 Dot-Matrix LCD |
| Optical Path | Single-Beam with Dual-Lamp Auto-Switching (Tungsten Lamp Only for Visible Range) |
| Data Interface | USB Port |
| Print Interface | Parallel Port |
| Power Supply | AC 220 V / 50 Hz or AC 110 V / 60 Hz |
| Dimensions (W×D×H) | 470 × 370 × 180 mm |
| Net Weight | 14 kg |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | V-1800PC |
| Price Range | USD 1,400–2,800 |
| Optical Design | Pseudo-Double-Beam |
| Detector | Silicon Photodiode |
| Wavelength Range | 320–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.5% T at 220 nm and 360 nm |
| Display | 128×64 Dot-Matrix LCD |
| Measurement Modes | Transmittance (T), Absorbance (A), Concentration (C), Energy (E) |
| Data Output | USB Interface |
| Print Output | Parallel Port |
| Power Supply | AC 220 V/50 Hz or AC 110 V/60 Hz |
| Dimensions (W×D×H) | 470 × 370 × 180 mm |
| Net Weight | 12 kg |
| Brand | MapIR |
|---|---|
| Origin | USA |
| Model | K2 Six-Channel |
| Imaging Principle | Filter-wheel-free filter-array-based multispectral imaging |
| Mounting | Airborne (UAV-integrated) |
| Field of View (TFOV) | 87° or 41° HFOV |
| Instantaneous Field of View (IFOV) | 2.0 cm/pixel at 120 m AGL (14.4 MP resolution) |
| Frame Rate | 2 fps (3.2 MP RAW), 1 fps (14.4 MP RAW) |
| Sensor | 14.4 MP Bayer CMOS, 1.4 × 1.4 µm pixel pitch |
| Spectral Configurations | Config 1 — 475 nm, 550 nm, 850 nm / 490 nm, 615 nm, 808 nm |
| Optional 5-band | 395 nm + 870 nm + three others |
| Trigger Interface | PWM, relay pulse (voltage-level), UAVCAN, UART |
| Output Format | 12-bit RAW per channel, 16-bit TIFF per channel |
| Onboard Storage | Removable microSDXC (up to 128 GB) |
| Processor | Freescale i.MX6 Dual Core ARM Cortex-A9 @ 1.2 GHz |
| Power | 5.0 VDC, 4.0 W per module |
| Connectivity | USB 2.0, UART, UAVCAN, PWM I/O, I²C, Ethernet, GPIO, HDMI, SD video, 40-pin side port, 60-pin bottom expansion port |
| Brand | MapIR |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | K4 Octo-Channel |
| Operating Principle | Filter-Wheel-Free Filter-Based Imaging |
| Imaging Method | Discrete Bandpass Filter Array |
| Deployment Platform | Airborne (UAV-Mounted) |
| Instantaneous Field of View (IFOV) | 2.0 cm/pixel at 120 m AGL (400 ft AGL), 14.4 MP resolution |
| Frame Rate | 2 fps (3.2 MP RAW), 1 fps (14.4 MP RAW) |
| Processor | Freescale i.MX6 Dual-Core ARM Cortex-A9 @ 1.2 GHz |
| Detectors | Two Sensor Types — Global Shutter Monochrome (13.2 MP, 3.45 µm pixel pitch) and Bayer RGB (14.4 MP, 1.4 µm pixel pitch) |
| Trigger Interface | PWM, Relay Pulse (High/Low), UAVCAN, UART |
| Image Format | 12-bit RAW per channel, 16-bit TIFF export |
| Lens Options | 87° or 41° Horizontal Field of View |
| Storage | Removable microSDXC (up to 128 GB) |
| Power | 5.0 VDC, 4.0 W per module |
| Connectivity | USB 2.0, UART, UAVCAN, I²C, Ethernet, GPIO, HDMI, SD Video, 40-pin Side Port, 60-pin Bottom Expansion Port |
| Brand | MapIR |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | K6 |
| Operating Principle | Filter-Wheel–Free Filter Array (Filter-Based) |
| Imaging Method | Simultaneous Multi-Channel Filter Array |
| Platform Integration | UAV-Mounted (Fixed-Wing & Multirotor Compatible) |
| Total Field of View (TFOV) | 87° or 41° HFOV |
| Processor | Freescale i.MX6 Dual-Core ARM Cortex-A9 @ 1.2 GHz |
| Sensor 1 (Mono) | 3.2 MP Global Shutter, 3.45 × 3.45 µm pixel size |
| Sensor 2 (RGB) | 14.4 MP Bayer, 1.4 × 1.4 µm pixel size |
| Spectral Options | 26 discrete monochrome filters (250–1000 nm) |
| Trigger Modes | PWM, Relay (voltage pulse), UAVCAN-synced autonomous capture |
| Output Format | 12-bit RAW per channel, 16-bit TIFF (per channel) |
| Frame Rate | 2 fps @ 3.2 MP RAW |
| Storage | Removable microSDXC (up to 128 GB) |
| Power | 5.0 VDC, 4.0 W per module |
| Lens FOV Options | 87° HFOV (wide) or 41° HFOV (narrow) |
| GSD | 4.3 cm/px (3.2 MP, 120 m AGL) |
| Interfaces | USB 2.0, UART, UAVCAN, PWM I/O, I²C, Ethernet, GPIO, HDMI, SD Video |
| Brand | MapIR |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | K6 |
| Spectral Configuration | 6-, 8-, 10-, or 11-channel modular multispectral imaging |
| Spectral Acquisition Method | Filter-wheel–free filter array (discrete bandpass filter modules) |
| Platform Integration | UAV-mounted (multirotor & fixed-wing compatible) |
| Spectral Band Options | 26 selectable narrowband filters (250–1000 nm), including monochrome (Mono) and RGB+SWIR hybrid configurations |
| Sensor 1 Resolution | 3.2 MP global shutter (mono channel), pixel size 3.45 × 3.45 µm |
| Sensor 2 Resolution | 14.4 MP Bayer color sensor (trichromatic output), pixel size 1.4 × 1.4 µm |
| Horizontal Field of View (HFOV) | 87° or 41° (lens-dependent) |
| Instantaneous Field of View (IFOV) | 4.3 cm/px (3.2 MP) or 2.0 cm/px (14.4 MP) at 120 m AGL (400 ft AGL) |
| Frame Rate | 2 fps (3.2 MP RAW), 1 fps (14.4 MP RAW) |
| Onboard Processing | Dual-core ARM Cortex-A9 @ 1.2 GHz (i.MX6 SoC) |
| Trigger Interface | PWM, relay pulse (voltage-level), UAVCAN, UART, GPIO |
| Image Format | 12-bit RAW per channel |
| Storage | Removable microSDXC card (up to 128 GB) |
| Power | 5.0 VDC, 4.0 W per module |
| Connectivity | USB 2.0, UART, UAVCAN, Ethernet, I²C, HDMI, SD video output, GPIO headers |
| Brand | MapIR |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | K6 |
| Operating Principle | Filter-Based Multispectral Imaging |
| Imaging Method | Discrete Bandpass Filter Wheel (Fixed-Filter Array) |
| Platform Integration | UAV-Mounted (Fixed-Wing & Multirotor Compatible) |
| Total Field of View (TFOV) | 87° or 41° Horizontal FOV |
| Instantaneous Field of View (IFOV) | 4.3 cm/pixel @ 120 m AGL (3.2 MP mode), 2.0 cm/pixel @ 120 m AGL (14.4 MP mode) |
| Frame Rate | 2 fps (3.2 MP RAW), 1 fps (14.4 MP RAW) |
| Onboard Processing | Dual-Core ARM Cortex-A9 i.MX6 SoC (1.2 GHz) |
| Sensor Configurations | Two Detector Options — Global Shutter Monochrome (13.2 MP, 3.45 µm pixel pitch) or Bayer Color (14.4 MP, 1.4 µm pixel pitch) |
| Trigger Interface | PWM, Relay (Voltage Pulse), UAVCAN (via GNSS/Flight Controller) |
| Image Format | 12-bit RAW per channel, 16-bit TIFF export |
| Storage | Removable microSD card (up to 128 GB) |
| Power | 5.0 VDC, 4.0 W per module |
| Spectral Flexibility | Interchangeable 10-channel filter sets (user-selectable center wavelengths & bandwidths) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MaxiDirect |
| Pricing | Upon Request |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Ir100-AC |
| Type | Online NIR Analyzer |
| Wavelength Range | 4-channel NIR |
| Scan Speed | 30 ms |
| Moisture Range | 0.1–70% w/w |
| Resolution | 0.01% |
| Accuracy | ±0.2% (matrix-dependent) |
| Housing Material | SS316L |
| IP Rating | IP65 |
| Operating Temperature | −10 to 50 °C |
| Humidity Range | 10–90% RH |
| Power Supply | DC 24 V, 2 A |
| Output Interfaces | TCP/IP, RS485/RS232, Digital Alarm Outputs (2 channels) |
| Probe Cable Length | Standard 5 m (extendable to 100 m) |
| Installation Distance | 250 ± 100 mm (non-contact transmission mode) |
| Weight | ≈9.8 kg |
| Dimensions | 130 × 360 × 160 mm |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | MAZ-Ra300-Acr |
| Instrument Type | Online Raman Spectrometer |
| Spectral Resolution | 6 cm⁻¹ |
| Concentration Range | 0.1–99.9% |
| Resolution | 0.01% |
| Probe Length | 150 mm / 1 m (customizable) |
| Cable Length | Standard 5 m (extendable to 100 m) |
| Operating Temperature | −10 to 130 °C |
| Wetted Materials | Hastelloy C / PTFE / M400 / Non-contact optical path |
| Process Connection Options | Non-contact direct irradiation, immersion flange, sanitary clamp, NPT thread, flow cell |
| Power Supply | 220 V AC, <0.2 A |
| Output Interfaces | TCP/IP, RS-485/232 (digital), dual-channel relay (alarm & limit control) |
| IP Rating (wetted parts) | IP67 |
| Max Pressure Rating | ≤1 MPa |
| Net Weight | ≈5 kg |
| Dimensions | 280 × 485 × 590 mm (L×W×H) |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MAZ-Ra300-BSJZ |
| Instrument Type | Online Raman Spectrometer |
| Spectral Resolution | 6 cm⁻¹ |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC016-6400A |
| Pricing | Available Upon Request |
| Sensitivity | K: 1 µg/mL for full-scale deflection |
| Na | 1 µg/mL for full-scale deflection |
| Repeatability | ≤2 scale divisions across 7 consecutive measurements of identical sample |
| Stability | ≤1 scale division drift over 15 s continuous aspiration |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC016-721 |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC016-722 |
| Pricing | Available Upon Request |
| Wavelength Range | 330–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 1 nm |
| Spectral Bandwidth | 4 nm |
| Transmittance Accuracy | ±0.5%T |
| Transmittance Repeatability | 0.2%T |
| Transmittance Range | 0.0–125%T |
| Absorbance Range | −0.301 to 1.999 A |
| Concentration Display Range | 0–1999 units |
| Stray Light | ≤0.5%T at 360 nm |
| Photometric Stability | ±0.003 A/h |
| Interface | RS-232 bidirectional serial port |
| Software Compatibility | SPD application software (Windows OS) |
| Data Functions | Photometric (T/A), Quantitative (C/F), Time Scan |
| Printer Support | Yes |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC016-723PC |
| Pricing | Upon Request |
| Wavelength Range | 320–1000 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.5 nm |
| Spectral Bandwidth | 2 nm |
| Transmittance Accuracy | ±0.5%T |
| Transmittance Repeatability | 0.2%T |
| Transmittance Range | 0.0–125%T |
| Absorbance Range | −0.097–2.5 A |
| Concentration Display Range | 0–99999 |
| Stray Light | ≤0.5%T @ 360 nm |
| Photometric Stability | ±0.002 A/h |
| Interface | RS-232 bidirectional serial port |
| Software | SPD application software for Windows |
| Printer Support | Integrated thermal printer |
| Measurement Modes | T (%T), A (Abs), C (Concentration), F (Factor) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC016-752 |
| Pricing | Available Upon Request |
| Wavelength Drive | Manual |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 1 nm |
| Spectral Bandwidth | 4 nm |
| Transmittance Accuracy | ±0.5%T |
| Transmittance Repeatability | 0.2%T |
| Transmittance Range | 0.0–125%T |
| Absorbance Range | −0.301 to 1.999 A |
| Concentration Display Range | 0–1999 units |
| Stray Light | ≤0.5%T at 220 nm and 360 nm |
| Photometric Stability | ±0.003 A/h |
| Interface | RS-232 bidirectional serial port |
| Printer Support | Yes |
| Software Compatibility | SPD application software for Windows (T/A/C/F modes, kinetic scanning, data logging) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC016-754PC(UV-2100 Export Model) |
| Pricing | Available Upon Request |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 1 nm |
| Spectral Bandwidth | 4 nm |
| Photometric Accuracy (Transmittance) | ±0.5%T |
| Photometric Repeatability (Transmittance) | 0.2%T |
| Transmittance Range | 0.0–125%T |
| Absorbance Range | –0.097 to 2.5 A |
| Concentration Display Range | 0–99999 |
| Stray Light | ≤0.5%T at 220 nm and 360 nm |
| Baseline Stability | ±0.002 A/h |
| Interface | RS-232 Bidirectional Serial Port |
| Software | SPD Application Suite for Windows |
| Printer Support | Integrated Thermal or Dot-Matrix via RS-232 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MC016-AA320CRT |
| Pricing | Available Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MC016-YRWFX-210 |
| Pricing | Available Upon Request |
| [Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Domestic |
| Detector Type | Charge-Coupled Device (CCD) |
| Channel Capacity | Up to 64 optical channels |
| Wavelength Range | 160–650 nm |
| Excitation Frequency | 200–600 Hz |
| Analytical Reproducibility | RSD ≤ 0.2% |
| Grating Radius | 1000 mm |
| Groove Density | 1667 lines/mm |
| Entrance Angle | 35° |
| Sample Gap | 4 mm |
| PMT Voltage Range | –550 V to –1000 V (8-step digital adjustment) |
| Thermal Stability | 35 °C ± 0.5 °C (localized spectrometer chamber)] |
| Brand | McPherson |
|---|---|
| Origin | USA |
| Model | 234/302 |
| Optical Configuration | Seya-Namioka (S-N) |
| Wavelength Range | 30–2200 nm |
| Resolution | 0.1 nm |
| Focal Length | 2000 mm |
| Brand | McPherson |
|---|---|
| Origin | USA |
| Model | Model 218 |
| Focal Length | 300 mm |
| Optical Design | Crossed Czerny-Turner |
| Beam Angle (Input/Output) | 44° |
| f/# | f/5.3 |
| Grating Size | 50 × 50 mm |
| Wavelength Accuracy | ±0.10 nm (mechanical counter, 1200 grooves/mm grating) |
| Wavelength Repeatability | ±0.005 nm (1200 grooves/mm grating) |
| Focal Plane Width | up to 17 mm |
| Wavelength Range | configurable per grating selection (VUV to LWIR) |
| Brand | McPherson |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 234/302 |
| Pricing | Upon Request |
| Focal Length | 200 mm |
| Optical Design | Modified Seya-Namioka |
| f/# | 4.5 |
| Grating Size | 40 × 45 mm |
| Wavelength Accuracy | ±0.10 nm (with 1200 g/mm grating) |
| Wavelength Repeatability | ±0.05 nm (with 1200 g/mm grating) |
| Slit-to-Slit Working Distance | 229 mm |
| Input/Output Beam Angle | 64° or 180° selectable |
| Focal Plane Width | 25 mm |
| Focal Plane Tilt | ~30° |
| Grating Options | 300–2400 g/mm |
| Resolution @ 313.1 nm | 0.06–0.3 nm (dependent on grating) |
| Reciprocal Linear Dispersion | 2–816 nm/mm |
| Detector Interface | CCD or MCP imaging array |
| Vacuum Compatibility | Standard UHV option (10⁻¹⁰ Torr with all-metal seals) |
| Residual Gas Analysis | Performed pre-shipment |
| Brand | McPherson |
|---|---|
| Origin | USA |
| Model | 248/310G |
| Wavelength Range | <1 nm to 310 nm |
| Spectral Resolution | 0.018 nm |
| Focal Length | 1000 mm |
| Optical Design | Grazing Incidence |
| Scanning Capability | Yes |
| Multichannel Detection Support | Yes |
| Compliance | Designed for UHV and synchrotron beamline integration |
| Detector Interface | Standard NIM & TTL-compatible output |
| Brand | McPherson |
|---|---|
| Origin | USA |
| Model | VUV Grating Spectrometer Series |
| Wavelength Range | 30 nm – 1200 nm (model-dependent) |
| Spectral Resolution | down to <0.0025 nm |
| Focal Length | 200 mm – 5000 mm |
| Optical Configuration | Czerny-Turner, Seya-Namioka, Normal Incidence (Autofocus & Off-Plane Eagle), Corrected Concave Holographic |
| Grating Mount | Motorized Multi-Grating Tower |
| Detector Compatibility | PMT, MCP, CCD, and Back-Illuminated Deep-UV/Soft-X-ray Arrays |
| Stray Light Suppression | <10⁻⁶ (typical, model- and grating-dependent) |
| Wavelength Accuracy | ±0.005 nm (with He-Ne reference laser calibration) |
| Dispersion | 1.2–8.5 nm/mm (depending on grating groove density and focal length) |
| Scan Functionality | Fully automated wavelength scanning with closed-loop encoder feedback |
| Multichannel Detection | Supported via fiber-coupled or direct-mount array detectors |
| Compliance | Designed for UHV-compatible operation (<1×10⁻⁷ Torr) |
| Brand | McScience |
|---|---|
| Origin | South Korea |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | M20 |
| Pricing | Upon Request |
| Spectral Range | 380–780 nm |
| Spectral Resolution | 1 nm |
| Luminance Measurement Range (Illuminant A) | 0.1–100,000 cd/m² |
| Imaging Capability | Integrated CCD Camera |
| Optional Accessories | Close-up Lens, Neutral Density Filters |
| Interface Compatibility | Windows PC & Android Tablet |
| Compliance | Designed for display metrology per CIE S 026/E:2015, ISO 13406-2, and VESA DisplayHDR™ test protocols |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MD100 |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Pharo 300 |
| Optical Design | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Light Source | Xenon Flash Lamp |
| Spectral Bandwidth | 4 nm |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (for A < 0.600 A) |
| Cuvette Types | 16 mm round, 10/20/50 mm square (auto-recognized) |
| Scan Increment | 1 nm |
| Data Storage | 1000 measurement results + 4 MB for spectral/dynamic data (e.g., 100 scans or 400 kinetics curves) |
| Compliance | DIN, US EPA certified methods |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating (1800 lines/mm) |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Spectral Resolution | <0.03 nm |
| Sensitivity | Cu 1 ppm → Absorbance >0.01 A |
| Precision (RSD) | ≤0.05% (Flame mode, optimized conditions) |
| Detection Limits | Cu ≤ 0.006 µg/mL (Flame), Cd ≤ 1.0 × 10⁻¹² g (Graphite Furnace) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame AAS |
| Model | AA-3600F |
| Monochromator | Plane Grating (1800 grooves/mm) |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-Reversal Method |
| Spectral Bandwidth | 0.2 / 0.4 / 1.0 / 2.0 nm (auto-switchable) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | 0.1 nm |
| Resolution | 0.1 nm |
| Characteristic Concentration (Cu) | 0.02 µg/mL per 1% absorption |
| Detection Limit (Cu) | 0.002 µg/mL |
| Baseline Drift | ≤0.004 A/30 min |
| Background Correction Capability | >30× at 1 A |
| RSD (Precision) | ≤1.0% |
| Atomizer | Air-Acetylene Flame |
| Lamp Turret | 6-position Auto-rotating Holder |
| Beam Splitting | Semi-reflective/Semi-transmissive Device for D₂ Background Balance |