Spectroscopy Instruments
Filter
Showing 121–150 of 2603 results
| Brand | Andor |
|---|---|
| Origin | Israel |
| Model | SR193i |
| Application Systems | Transmission & Reflection Spectroscopy |
| Grating Configuration | Dual-grating turret |
| Spectral Resolution | 0.21 nm @ 1200 g/mm, 500 nm |
| Dispersion | 2.6 nm/mm |
| Wavelength Range | 200–1100 nm |
| F/# | 3.6 |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | 1.5 × 10⁻⁴ |
| Focal Length | 193 mm |
| Imaging Optics | Aplanatic toroidal mirrors |
| Spectral Reproducibility | ±75 pm |
| Grating Turret | RFID-enabled, quick-release dual-grating turret |
| Detector Compatibility | Dual-output port for simultaneous CCD/EMCCD or sCMOS detector coupling |
| Slit Output Option | Configurable monochromator mode |
| Microscope Integration | C-mount and SM1-threaded interfaces compliant |
| Brand | Andor |
|---|---|
| Origin | United Kingdom |
| Model | SR303i |
| Spectral Range | 303–800 nm |
| F/# | F/4 |
| Wavelength Accuracy | ±0.04 nm |
| Wavelength Repeatability | ±0.004 nm |
| Spectral Resolution | 0.08 nm @ 2400 grooves/mm, 300 nm |
| Dispersion | 2.2 nm/mm |
| Stray Light Suppression | ≤2.2×10⁻⁵ |
| Grating Configuration | Triple-grating turret |
| Input/Output Ports | Configurable (1 or 2 CCD outputs, motorized slit) |
| 焦平面尺寸 | 28 mm × 14 mm |
| Grating Size | 68 mm × 68 mm |
| Slit Width | Dynamic, up to 12 mm |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-3000 Plus |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 nm, 0.2 nm, 0.4 nm, and 1.0 nm (selectable) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | 0.1 nm |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Photomultiplier Tube (PMT) Detector |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 nm / 0.2 nm / 0.4 nm / 1.0 nm (selectable) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Brand | ANJIE |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-3700 |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Noise | ±0.0002 Abs |
| Baseline Drift | ±0.0005 Abs (30 min) |
| Linearity (r) | >0.9995 |
| Detection Limits | NH₃-N: 0.005 mg/L |
| Total N | 0.02 mg/L |
| S²⁻ | 0.005 mg/L |
| NO₂⁻-N | 0.003 mg/L |
| NO₃⁻-N | 0.006 mg/L |
| Kjeldahl N | 0.02 mg/L |
| Quantification Ranges | NH₃-N: 0.02–80 mg/L |
| Total N | 0.1–160 mg/L |
| S²⁻ | 0.02–200 mg/L |
| NO₂⁻-N | 0.012–200 mg/L |
| NO₃⁻-N | 0.03–160 mg/L |
| Kjeldahl N | 0.08–80 mg/L |
| Precision | 0.5–1.0% RSD (at specified concentrations) |
| Measurement Time | 100–280 s (including online digestion for total nitrogen) |
| Brand | ANJIE |
|---|---|
| Origin | Shanghai, China |
| Model | AJ-500 / AJ-900 |
| Sample Tray Configurations | 90-position (86 × 15 mL + 4 × 50 mL) or 51-position (51 × 50 mL) |
| Detector Interface | Photomultiplier Tube (PMT) Compatible |
| Brand | Anjie |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic |
| Model | AJ-510 |
| Quotation | Upon Request |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 2.0 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.1 nm |
| Brand | ANPRO |
|---|---|
| Model | APN-II |
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Wavelength Range | 185–950 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ≤±0.05 nm |
| Detector | CCD Array |
| Optical System | Dual-Wavelength Scanning with Hybrid Diffraction Grating |
| Automation Level | Fully Automatic Wavelength Selection & Sample Handling |
| Sample Throughput | Up to 12 Cuvettes (11 Simultaneous Samples + Reference) |
| Display | 10.1-inch Capacitive Touch LCD with VGA/HDMI Output |
| Computing Platform | Embedded Industrial PC (Quad-Core CPU, 4 GB RAM, Windows OS) |
| Data Storage | 500 GB SSD |
| Connectivity | Dual USB 2.0, RS232, Ethernet, Wi-Fi, VGA, Audio Out |
| Compliance | Designed for GLP-compliant food safety laboratories |
| Brand | Anritsu |
|---|---|
| Origin | Japan |
| Model | MS9740B |
| Wavelength Range | 600–1750 nm |
| Wavelength Accuracy | ±20 pm (1520–1620 nm, RBW 0.03–0.2 nm) / ±100 pm (1520–1620 nm, RBW 0.5/1.0 nm) |
| Wavelength Resolution (RBW) | 0.03 / 0.05 / 0.07 / 0.1 / 0.2 / 0.5 / 1.0 nm (3 dB bandwidth) |
| Dynamic Range | ≥60 dB at 0.4 nm offset from peak |
| Minimum RBW | 30 pm |
| Scan Speed | ≤0.2 s for 5 nm span (RBW 0.1 nm, VBW 10 kHz) |
| Max Input Power | +23 dBm (with optical attenuator enabled) |
| Fiber Compatibility | SMF-28 (9/125 µm, ITU-T G.652), 50/125 µm GI fiber |
| Connector Options | Interchangeable FC, SC, ST, DIN, LC |
| Storage Capacity | Up to 1,000 files or 10,000 spectra |
| Interfaces | Ethernet (standard), GPIB (optional) |
| Dimensions | 426 × 177 × 350 mm (W×H×D, excluding protrusions) |
| Weight | ≤15.0 kg (excluding options) |
| Power Consumption | ≤75 VA |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Cora 100 |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | ≤10 cm⁻¹ |
| Spatial Resolution | <1 mm |
| Minimum Wavenumber | 400 cm⁻¹ |
| Spectral Reproducibility | High repeatability across repeated measurements on identical samples |
| Laser Wavelength | 785 nm |
| Laser Power at Sample | >215 mW (output: 300 mW) |
| Detector | Linear CCD Array |
| Display | 3.5″ Transmissive TFT with LED Backlight |
| Operating System | Embedded Linux |
| Data Format | Text (.txt, .csv, .spc) |
| Interface | USB 2.0 |
| Battery | Rechargeable Li-ion (≈60 scans per charge, non-user-replaceable) |
| Dimensions | 15.8 × 10.1 × 2.9 cm |
| Weight | 650 g |
| IP Rating | IP67 |
| Operating Temperature | −20 °C to +40 °C |
| Storage Temperature | −30 °C to +50 °C |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | Cora 100 |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | <10 cm⁻¹ |
| Spatial Resolution | <1 mm |
| Laser Wavelength | 785 nm |
| Laser Power at Sample | >215 mW |
| Detector | Linear CCD Array |
| Display | Transflective TFT with LED Backlight |
| Operating Temperature | −20 °C to +40 °C |
| IP Rating | IP67 |
| Dimensions | 15.8 cm × 10.1 cm × 2.9 cm |
| Weight | 650 g |
| Battery Life | Up to 60 scans per charge |
| Data Format | Text (.txt) |
| Connectivity | USB 2.0 |
| OS | Embedded Linux |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Portable/Desktop Raman Spectrometer |
| Model | Cora 5001 |
| Spectral Range | 100–3500 cm⁻¹ |
| Spectral Resolution | 6–9 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | < 0.5 cm⁻¹ |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Cora 5001 |
| Detector Type | CMOS |
| Laser Class | Class 1 |
| Safety Interlock | Integrated shutter-based activation (laser only active when sample chamber is fully closed) |
| Optical Architecture | Monolithic aluminum optical bench, no moving parts |
| Focus Mechanism | Motorized auto-focus with real-time signal optimization |
| Excitation Options | Dual-wavelength “Dual-Core Raman” configuration available (e.g., 785 nm and 1064 nm) |
| Sample Compatibility | Solids (tablets, films, crystals), liquids (in vials of circular/square/rectangular cross-section), powders, pastes |
| Accessories | Magnetic sample holders, universal vial adapters, solid-sample stage with quick-lock positioning |
| Compliance | IEC 60825-1:2014 (Class 1 laser product), CE marked, RoHS compliant |
| Software | Cora Suite v3.x with spectral library matching (≥10,000 reference spectra), GLP-compliant audit trail, FDA 21 CFR Part 11 optional module |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Cora 5001 Direct |
| Instrument Type | In-line Raman Spectrometer |
| Spectral Range | 100–3500 cm⁻¹ (wavelength-dependent) |
| Laser Classes | Class 1 (Direct model) |
| Excitation Wavelengths | 532 nm, 785 nm, 1064 nm (single- or dual-wavelength configurations) |
| Spectral Resolution (per ASTM E2529) | 6–17 cm⁻¹ (wavelength-dependent) |
| Detector | 2048-pixel CCD (532/785 nm), 256-pixel InGaAs (1064 nm) |
| Auto-focus | Yes |
| Software | Anton Paar Spectroscopy Suite (with audit trail, electronic signatures, SQL database, GLP/GMP support) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Cora 5001 Fiber |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 100–3500 cm⁻¹ |
| Spectral Resolution | 6–9 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | < 0.5 cm⁻¹ |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Lyza 3000 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 350–7500 cm⁻¹ |
| Spectral Resolution | <1.4 cm⁻¹ (0.7 cm⁻¹ optional) |
| Scan Speed | <30 seconds per spectrum |
| Signal-to-Noise Ratio (S/N) | 55,000:1 (at 4 cm⁻¹, 16 scans, DTGS detector) |
| Wavenumber Accuracy | <0.05 cm⁻¹ |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 550–6000 cm⁻¹ |
| Resolution | 8 cm⁻¹ |
| Scan Speed | 48 scans per 35 seconds |
| Signal-to-Noise Ratio | 46,980:1 |
| ATR Prism | 12-reflection diamond crystal |
| Temperature Control Accuracy | ±0.03 °C |
| Interface | 10.1-inch capacitive touchscreen |
| Automation Compatibility | Xsample 520 (24-position autosampler optional) |
| Data Export | LIMS-compatible, PDF/CSV report generation |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Lyza 7000 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 350–7500 cm⁻¹ |
| Spectral Resolution | <1.4 cm⁻¹ |
| Scan Speed | <30 s per spectrum |
| Signal-to-Noise Ratio | 55,000:1 (at 4 cm⁻¹, 32 scans) |
| Wavenumber Accuracy | <0.05 cm⁻¹ |
| Brand | Anyty |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | 3R-PPSC410 |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 5 nm |
| Spatial Resolution | 1920 × 1920 pixels |
| Total Field of View (TFOV) | 25° |
| Platform Compatibility | Ground-based and UAV-mounted operation |
| Working Principle | Push-broom hyperspectral imaging with integrated CMOS sensor and transmission grating spectrometer |
| Brand | Anyty |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | 3R-PPSC417 |
| Pricing | Upon Request |
| Operating Principle | Reflectance-Based Hyperspectral Imaging |
| Deployment Modes | Ground-Based & Airborne (UAV-Compatible) |
| Spectral Range | 390–1710 nm |
| Spectral Resolution | 18 nm |
| Spatial Resolution | 640 × 640 pixels |
| Total Field of View (TFOV) | 25° |
| Brand | Anyty |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 3R-TST100 |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 150–3500 cm⁻¹ |
| Spectral Resolution | ≤6 cm⁻¹ |
| Spectral Repeatability | ±0.3 cm⁻¹ |
| Brand | Anyty |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | 3R-TSTD1045 |
| Price | Upon Request |
| Spectral Range | 150–3500 cm⁻¹ |
| Spectral Resolution | ≤6 cm⁻¹ |
| Brand | Anyty |
|---|---|
| Model | 3R-TXL |
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Excitation Source | 4 W micro-integrated X-ray tube (50 kV, 200 µA, Ag anode |
| Detector | Fast Silicon Drift Detector (SDD), energy resolution ≤125 eV |
| Filter System | 5-position automatic filter wheel |
| CPU | Quad-core low-power industrial processor (1.44 GHz) |
| Data Storage | 64 GB internal flash memory (≥200,000 spectra + reports) |
| Display | 5-inch high-brightness auto-adaptive LCD touchscreen |
| Operating Temperature | −20 °C to +55 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Battery | 6800 mAh Li-ion, ≥8 h continuous operation |
| Weight | 1.8 kg |
| Dimensions | 250 × 320 × 80 mm |
| GPS | Integrated dual-frequency GNSS module with altitude and coordinate logging |
| Connectivity | USB 2.0, Wi-Fi 802.11 b/g/n, Bluetooth 4.2 |
| Safety | Interlocked beam shutter, air-gap safety design, certified exempt from radiation licensing per Chinese MEE regulatory framework |
| Software Platform | Custom industrial Windows IoT OS (Android optional) |
| Detection Range | Mg (12) to U (92) |
| Quantification Accuracy | 0.01–99.99 wt% (matrix-dependent, calibrated per ISO 18505-2 and ASTM E2811) |
| Cloud Integration | OTA firmware updates, remote diagnostics, secure data sync via encrypted TLS 1.2 channel |
| Brand | AOE |
|---|---|
| Model | 6400A |
| Origin | Shanghai, China |
| Type | Benchtop Flame Emission Spectrometer |
| Detection Elements | K, Na, Li, Ca, Ba |
| Optical System | Interference Filter-Based Monochromator |
| Detector | Silicon Photocell |
| Display | LCD |
| Sample Uptake Rate | <6 mL/min |
| Response Time | <8 s |
| Stability (15 s) | ≤3% RSD |
| Stability (6 min, 6 readings) | ≤15% RSD |
| Repeatability | ≤3% RSD |
| Linearity Error | K: ≤0.005 mmol/L (0.0100–0.0800 mmol/L) |
| Na | ≤0.03 mmol/L (0.0500–0.400 mmol/L) |
| Detection Limit | K: ≤0.004 mmol/L |
| Na | ≤0.008 mmol/L |
| Potassium Filter | Peak Wavelength Tolerance ≤±7 nm, FWHM ≤15 nm, Background Transmittance ≤0.5% |
| Sodium Filter | Peak Wavelength Tolerance ≤±5 nm, FWHM ≤15 nm, Background Transmittance ≤0.5% |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–160 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–100 µg/mL |
| Ba | 0–3000 µg/mL |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | A360 |
| Price Range | USD 4,200 – 7,000 |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | ≤0.03% T @ 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | A380 |
| Price Range | USD 4,200–7,000 (FOB Shanghai) |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | ≤0.03% T @ 220 nm & 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | A390 |
| Price Range | USD 4,200–7,000 (FOB Shanghai) |
| Optical Design | Single-Beam with Dual-Beam Ratio Monitoring |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5, 1.0, 2.0, 4.0, 5.0 nm |
| Stray Light | ≤0.03% T at 360 nm |
| Display | 6.5K-color TFT LCD (800 × 480) |
| Data Storage | 240 calibration curves (240 data points each) onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.1 host port for firmware update |
| Software | AOE Basic Spectroscopy Suite (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001:2015, CE (2014/30/EU & 2011/65/EU), CMC License (PRC Metrology Certification), RoHS Directive 2011/65/EU |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | A560 |
| Optical System | Dual-beam ratio-monitoring |
| Detector Type | Silicon photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.02% T at 360 nm |
| Wavelength Scanning | Automatic |
| Display | 800 × 480 pixel, 65K-color TFT LCD |
| Data Storage | 240 curves (240 data points each) onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.0 for PC connectivity |
| Software | AOE Basic Spectroscopy Software (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | A580 |
| Optical System | Dual-beam ratio-monitoring |
| Detector Type | Silicon photodiode |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.0 nm |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | ≤0.02% T @ 360 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Display | 800 × 480 pixel, 65K-color TFT LCD |
| Data Storage | 240 curves (240 data points each) onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.0 for PC connectivity |
| Software | AOE Basic Spectroscopy Software (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | A590 |
| Optical System | Dual-Beam Ratio-Monitoring |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm |
| Stray Light | ≤0.02% T @ 360 nm |
| Display | 800 × 480 TFT color LCD (65K colors) |
| Data Storage | 240 curves × 240 data points onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.0 for PC connectivity |
| Software | AOE Basic Spectroscopy Suite (certified under PRC Software Copyright Registration) |
| Compliance | ISO 9001, CE, CMC, RoHS |