Spectroscopy Instruments
Filter
Showing 901–930 of 1315 results
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Domestic |
| Model | SP301 / SP301-EX |
| Pricing | Upon Request |
| Instrument Class | Optical Photothermal Infrared Spectrometer |
| Form Factor | Portable |
| Wavenumber Range | 3333–10000 cm⁻¹ (equivalent to 1.0–3.0 µm for PbS |
| Spectral Resolution | 10–30 nm (dependent on slit width and grating selection) |
| Signal-to-Noise Ratio | ≥20 RMS counts (16-bit digitization) |
| Detector Cooling | Thermoelectric (TE), down to –20 °C |
| Detector Type | Linear PbS or PbSe array (256 pixels, 45 µm × 450 µm active area) |
| Max Readout Rate | 2 MHz |
| Linearity | >90% |
| Pixel-to-Pixel Response Uniformity (peak-to-peak) | ±10% |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SP304 |
| Instrument Class | Optical Photothermal Infrared Spectrometer |
| Form Factor | Portable |
| Wavelength Ranges | 0.9–1.7 µm, 0.9–2.05 µm, 0.9–2.2 µm, 0.9–2.5 µm |
| Spectral Resolution | >3 nm (overall, depending on configuration) |
| Signal-to-Noise Ratio | >15,000:1 @ 100 ms integration time |
| Detector Types | 256- and 512-pixel TE-cooled InGaAs linear arrays |
| Pixel Dimensions | 25 × 250 µm or 25 × 500 µm (model-dependent) |
| Compliance | CE, RoHS, ISO 9001-aligned manufacturing & calibration protocols |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | New SPECTRO ARCOS |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | <1 ppb |
| Precision (RSD) | 0.5% |
| Long-Term Stability | 1% |
| Wavelength Range | 130–770 nm |
| Optical Resolution | <8.5 pm |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SPECTRO ARCOS |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | Sub-ppb to ppm |
| Repeatability | ≤1% RSD |
| Long-Term Stability | ≤0.1% RSD |
| Wavelength Range | 130–770 nm |
| Optical Resolution | ≤0.008 nm |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTRO GENESIS |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Optical Detection | Dual-View Vertical Torch Configuration |
| Cooling | Air-Cooled Only |
| Purge Gas Flow | As Low as 0.5 L/min |
| Linear Dynamic Range | Sub-ppb to Percent Level |
| Sample Throughput | Up to 700 Samples per Day |
| Optical Architecture | DSOI (Dual-Spectrometer Optimized Imaging) |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTRO GENESIS |
| Type | Full-Spectrum Simultaneous ICP-OES |
| Wavelength Range | 175–770 nm |
| RF Generator | 27 MHz Solid-State |
| Optical Purge Flow | ≥0.5 L/min (Argon or Nitrogen) |
| Sample Throughput | Up to 700 samples/day |
| Detector | High-Quantum-Efficiency CCD Array |
| Compliance | ASTM D5185, D6595, ISO 11885, USP <233>, EPA Methods 200.7, 6010D, 6020B, GLP/GMP-ready with 21 CFR Part 11–compliant software options |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTRO M.01 |
| Instrument Type | Benchtop |
| Technology | Spark Optical Emission Spectrometry (OES) |
| Target Matrix | Ferrous Alloys |
| Compliance | ISO/IEC 17025 compatible, ASTM E415, ASTM E1086, EN 10315, DIN 51008 |
| Software | SPECTRO AnalyzeNet v3.x with ICAL 2.0 calibration technology |
| Gas Requirement | High-purity argon (≥99.996%) |
| Cooling | Air-cooled |
| Safety | CE, UL 61010-1 compliant |
| Data Management | Audit trail, user access levels, GLP/GMP-ready reporting |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SpectrOil 100 |
| Pricing | Available Upon Request |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTROLAB S LAS02 |
| Instrument Type | Floor-Standing |
| Excitation Source | Spark |
| Detector Type | CMOS+T Solid-State Array |
| Focal Length | 750 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 120–800 nm |
| Number of Channels | Application-Defined |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTROMAXx (Desktop) |
| Instrument Type | Desktop |
| Excitation Method | Spark |
| Detector Type | CMOS |
| Focal Length | 400 mm |
| Grating Density | 3600 lines/mm |
| Wavelength Range | User-Configurable |
| Number of Channels | Application-Dependent |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTROMAXx (Floor-standing) |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector Type | CMOS |
| Focal Length | 400 mm |
| Grating Density | 3600 lines/mm |
| Wavelength Range | User-configurable |
| Number of Channels | Application-dependent |
| Compliance | ASTM E1184, ISO 11577, ISO 6871, EN 10052, USP <233>, FDA 21 CFR Part 11 (software-enabled), GLP/GMP-ready audit trail |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTROMAXx08 |
| Excitation Source | Spark |
| Detector Type | Charge-Coupled Device (CCD) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | User-configurable |
| Number of Channels | Not applicable (Full-spectrum CCD-based system) |
| Instrument Form Factor | Floor-standing |
| Application Domain | Metal & Foundry Quality Control, Incoming/Outgoing Material Inspection, Process Monitoring |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SPECTROPORT |
| Instrument Type | Portable / Field-Deployable |
| Excitation Method | Spark Discharge |
| Detector Type | CCD (Charge-Coupled Device) |
| Focal Length | 300 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 178–530 nm |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Instrument Type | Portable/Mobile |
| Excitation Method | Spark & Arc |
| Detector Type | CCD (Charge-Coupled Device) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 174–670 nm |
| Number of Channels | Unlimited |
| Power Supply | Rechargeable Battery (up to 800 measurements per charge) |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SPECTRO TEST |
| Instrument Type | Portable/Mobile |
| Excitation Method | Spark & Arc |
| Detector Type | CCD (Charge-Coupled Device) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 174–670 nm |
| Spectral Coverage | Full-Spectrum (Echelle + Prism Cross-Dispersion) |
| Price Range | USD 52,000–65,000 (FOB Hamburg) |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTROCHECK LMM02 |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | CMOS |
| Focal Length | 400 mm |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SPECTROGREEN |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | Sub-ppb |
| Precision (RSD) | <1.5% |
| Long-Term Stability (RSD) | <0.5% |
| Wavelength Range | 165–770 nm |
| Optical Resolution | 0.007 nm |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | SPECTRONIC 200 |
| Instrument Architecture | Single-beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 340 nm – 1000 nm |
| Wavelength Scanning | Motorized Auto-wavelength Selection |
| Spectral Bandwidth | < 4 nm |
| Wavelength Accuracy | ±1.0 nm (typical, per ASTM E275) |
| Stray Light | < 0.1% T at 340 nm (as measured per ISO 9050) |
| Brand | SpectrUM / EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Model | EXPEC 6000 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit | Not Specified |
| Precision (RSD) | Not Specified |
| Long-Term Stability | Not Specified |
| Wavelength Range | Not Specified |
| Optical Resolution | Not Specified |
| Brand | SPECTRUMA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GDA 650 / GDA 150 |
| Pricing | Available Upon Request |
| Brand | SPECTRUMA |
|---|---|
| Origin | Germany |
| Model | GDA 750 / GDA 550 |
| Detection Principle | Glow Discharge Optical Emission Spectroscopy (GD-OES) |
| Spectral Range | 190–800 nm (standard PMT system) |
| Spectral Resolution | <20 pm FWHM (PMT) |
| Optical System | Paschen-Runge mount, 750 mm focal length, holographically ruled grating (2400 lines/mm) |
| Max. Analytical Depth | >200 µm |
| Depth Resolution | ≤1 nm |
| Elemental Coverage | H, O, N, Cl, C, and all elements from Li to U |
| Detection Limits | Sub-ppm (matrix-dependent) |
| Sputter Diameter | 1–8 mm (adjustable, same source) |
| DC Source | Up to 1500 V, 250 mA, fully programmable |
| RF Source | Up to 150 W, pulsed mode optional (GDA 750 only) |
| Sample Thickness Range | 50 µm – 45 mm |
| Vacuum System | Dual-stage rotary vane pump (<50 dB), oil-free pump for source chamber |
| Optional Accessories | High-resolution CCD optical system, RF pulse generator, load-lock transfer chamber, 100-position autosampler, monochromator with triple-grating turret |
| Brand | SPECTRUMA |
|---|---|
| Country of Origin | Germany |
| Model | GDA 750 / GDA 550 |
| Optical Resolution | <20 pm (FWHM) |
| Spectral Range | 190–800 nm (PMT), 200–800 nm (CCD option) |
| Maximum Analysis Depth | >200 µm |
| Depth Resolution | ≤1 nm |
| Detection Limits | Sub-ppm |
| Excitation Source | DC (0–1500 V, 0–250 mA), RF (up to 150 W, pulsed mode optional for GDA 750) |
| Sample Diameter Range | 1–8 mm |
| Vacuum System | Dual-stage rotary vane pump (oil-free for source), optional turbomolecular pump |
| Software Platform | WinGDOES (Windows XP or later) |
| Weight | ~580 kg |
| Dimensions | 1380 × 1440 × 890 mm |
| Brand | SPECTRUMA |
|---|---|
| Origin | Germany |
| Model | GDA 750 HR |
| Detection Range | H–U (76 elements) |
| Detection Limit | sub-ppm level |
| Depth Resolution | nanometer-scale to several hundred micrometers |
| Quantitative Precision | RSD < 2% (content), RSD < 5% (depth) |
| Sample Types | conductive & non-conductive solids (flat, curved, thin-film, air-sensitive layers) |
| Compliance | ISO/IEC 17025-ready architecture, GLP-compatible data handling |
| Brand | SPECTRUMA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GDA Alpha |
| Pricing | Upon Request |
| Brand | SPECTRUMA |
|---|---|
| Origin | Germany |
| Model | GDA150 HR |
| Detector Type | Thermally Stabilized CCD |
| Light Element Capability | C, N, H (O optional) |
| Sample Type | Conductive solids only |
| Application Scope | Depth profiling, surface diffusion analysis, coating & plating evaluation, hard coating characterization |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | SpectrumTEQ-EL |
| Spectral Range | 350–1100 nm |
| Detector | CCD |
| Optical Resolution | 2.5 nm (FWHM) |
| Sensitivity | 0.14–7.7 nm (wavelength-dependent responsivity) |
| Signal-to-Noise Ratio | 1000:1 |
| Dynamic Range | 85,000:1 (typical, single acquisition, QEPro) |
| Stray Light | <0.08% at 600 nm |
| Integrating Sphere Diameter | 3.3" or 1.5" |
| Sphere Coating | Spectralon® |
| Source Meter | Keithley 2400 |
| Fiber Core Diameter | 1000 µm (interchangeable) |
| Calibration Standard | HL-3-INT-CAL 2π geometry, 50 lm, 5 W |
| AD Resolution | 18-bit (QEPro), 16-bit (QE65Pro) |
| Software | SpectrumTEQ-EL dedicated application |
| Brand | StellarNet |
|---|---|
| Origin | USA |
| Model | Blue-Wave |
| Spectral Range | 280–900 nm |
| Detector Type | CCD |
| Optical Resolution | 0.75–6 nm (FWHM) |
| Sensitivity | 100 photons/count at 400 nm |
| Signal-to-Noise Ratio | 1000:1 (full well) |
| Dynamic Range | 2000:1 (6 decades) |
| Stray Light | 0.02% at 435 nm |
| Brand | Supernova / EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | EXPEC 6500 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | Not Specified |
| Precision (RSD) | <1% @ 8 h |
| Wavelength Range | 160–900 nm |
| Optical Resolution | Not Specified |
| RF Power Range | 500–1600 W (Digital Self-Excited Solid-State Generator) |
| Observation Mode | Dual-View Vertical Torch (Axial & Radial) |
| Detector | Custom Large-Area E-CCD |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | GMA3500 |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1 / 0.2 / 0.4 / 0.7 / 1.0 / 2.0 nm (6-step auto-switching) |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Brand | Synpec |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | GMA3860 |
| Price Range | USD 42,000 – 56,000 |
| Compliance | GB/T 42027-2022, HJ 195-2023, HJ 200-2023, HJ/T 198-2005, HJ/T 197-2005, HJ 199-2023 |
| Light Source | Deuterium Lamp (with optional element lamps for Hg analysis) |
| Detector | CCD Diode Array |
| Key Features | Integrated UV digestion-dilution module for total nitrogen, on-line oxidation for ammonia-N, cold trap + auto-dehydration system, auto-rinsing during NO₃⁻/TN analysis, programmable dilution, optional autosampler (7- or 60-position) |