Spectroscopy Instruments
Filter
Showing 871–900 of 2561 results
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 1.5 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | 1.5 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Compliance | ISO/IEC 17025-compatible optical validation protocols, ASTM E275 and E387 spectral performance standards |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Configuration | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1 nm |
| Automation Level | Automatic Wavelength Scanning |
| Standard Sample Changer | Integrated 6-Position Auto-Cuvette Holder |
| Light Source | Long-Life Pulsed Xenon Lamp (7-Year Limited Warranty, Subject to Usage Conditions) |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Corporation |
| Instrument Type | Dual-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–3300 nm |
| Wavelength Accuracy | ±0.05 nm (UV-Vis), ±0.2 nm (NIR) |
| Spectral Bandwidth | UV-Vis: 0.1, 0.2, 0.5, 1, 2, 5, 10 nm |
| NIR | 0.25, 0.5 nm |
| Wavelength Scanning Mode | Automatic |
| Slit Control | Motorized continuous variable slit |
| Optical System | Etched holographic diffraction grating, high-flux monochromator |
| Software | UV Solutions Plus with customizable reporting, data table view, instrument performance verification module |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Corporation |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Dual-Beam |
| Monochromator | Custom High-Resolution Grating (Motor-Driven for ZA4800) |
| Detector | Photomultiplier Tube (Dual-Detector Configuration) |
| Background Correction | Polarized Zeeman Correction (Full-Wavelength, Real-Time) |
| Baseline Stability | ≤ 0.0004 Abs / 30 min |
| Element Simultaneity | Up to 12 Elements in Sequential Mode (ZA4800) |
| Compliance | ASTM E1756, ISO 8289, USP <731>, FDA 21 CFR Part 11 (Audit Trail & Electronic Signature Ready), GLP/GMP-Ready Software Architecture |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame–Graphite Furnace Hybrid AAS |
| Monochromator | Fixed-grating with selectable slits |
| Optical System | Double-beam |
| Detector | Solid-state CCD array |
| Background Correction | Simultaneous D₂-lamp and Self-reversal (SR) correction |
| Spectral Bandwidth | 0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm (auto-switching) |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | 0.1 nm |
| Resolution | 0.2 nm |
| Cu Detection Limit (Flame) | ≤0.004 µg/mL |
| Cu Characteristic Concentration (Flame) | ≤0.025 µg/mL per 1% absorption |
| Precision (RSD, Cu, A > 0.8) | ≤0.5% |
| Baseline Drift | ≤0.002 A / 30 min |
| Graphite Furnace Max Ramp Rate | ≥3000 °C/s |
| Graphite Furnace Temp Range | Ambient to 3000 °C |
| Cd Characteristic Mass | ≤1 pg |
| Cu Characteristic Mass | ≤10 pg |
| Graphite Furnace Precision (RSD) | ≤3% (Cd, Cu) |
| Lamp Turret | 6-position automatic |
| Auto-sampler Options | 45- or 85-position |
| Gas Control | Dual-path (in-tube / out-tube) inert gas regulation |
| Safety Systems | Real-time flame status monitoring, gas pressure sensors (air, acetylene, N₂O), auto-shutdown on flame failure/flashback, power-interruption cutoff, overtemperature/coolant-flow interlock |
| Dimensions | 700 × 550 × 440 mm |
| Weight | 80 kg |
| Power Requirement | 220 V AC, 6000 W nominal, transient peak up to 8 kW |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | LC-R720 |
| Operating Principle | Liquid Crystal on Silicon (LCoS)-Based Optical Phase/Amplitude Modulation |
| Imaging Method | Binary Optical Element |
| Deployment Environment | Benchtop / Laboratory |
| Spectral Range | 420–700 nm |
| Spatial Resolution | 1280 × 768 pixels |
| Pixel Pitch | 20 µm |
| Fill Factor | 92% |
| Addressing Depth | 8-bit |
| Frame Rate | 180 Hz |
| Response Time | <3 ms |
| Phase Modulation Range | >π radians (visible spectrum) |
| Dynamic Range | 1000:1 |
| Field of View (TFOV) | 15.36 × 8.64 mm |
| Instantaneous Field of View (IFOV) | 78 µrad |
| Synchronization | Hardware Trigger Support |
| Video Interface | Digital Visual Interface (DVI) |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | LETO-3 |
| Spectral Range | 400–1100 nm |
| Resolution | 1920 × 1080 pixels |
| Pixel Pitch | 6.4 µm |
| Fill Factor | 93% |
| Field of View (TFOV) | 15.36 × 8.64 mm |
| Instantaneous Field of View (IFOV) | 7.8 µrad |
| Frame Rate | 60 Hz |
| Interface | HDMI (video input), USB 2.0 (control) |
| Operating Mode | Pure-phase modulation only |
| Optical Configuration | Transmissive, binary-optical element |
| Mounting | Benchtop / Ground-based optical setup |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | PLUTO-2.1 NIR-015 |
| Spectral Range | 650–1100 nm |
| Resolution | 1920 × 1080 pixels |
| Pixel Pitch | 8 µm |
| Field of View (TFOV) | 15.36 × 8.64 mm |
| Instantaneous Field of View (IFOV) | 7.8 µrad |
| Frame Rate | 60 Hz |
| Addressing | 8-bit grayscale via VGA/HDMI/DisplayPort (green channel), USB-controlled gamma and voltage range tuning |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PLUTO-2.1 NIR-145 |
| Spectral Range | 420–1064 nm |
| Resolution (Spatial & Spectral) | 1920 × 1080 pixels |
| Pixel Pitch | 8 µm |
| Total Field of View (TFOV) | 15.36 × 8.64 mm |
| Instantaneous Field of View (IFOV) | 7.8 µm |
| Frame Rate | 60 Hz |
| Interface | USB-controlled driver + HDMI/DisplayPort video input |
| Operating Mode | Pure-phase modulation |
| Compatibility | Standard GPU-based phase pattern streaming via green-channel 8-bit grayscale addressing |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PLUTO-2.1-NIR-118 |
| Operating Wavelength Range | 730–950 nm |
| Spatial Resolution | 1920 × 1080 pixels |
| Pixel Pitch | 8 µm |
| Field of View (TFOV) | 15.36 × 8.64 mm |
| Instantaneous Field of View (IFOV) | 62.5 lp/mm |
| Frame Rate | 60 Hz |
| Modulation Type | Pure-Phase, Liquid Crystal on Silicon (LCoS) |
| Interface | USB-controlled gamma calibration + HDMI/DisplayPort video input |
| Bit Depth | 8-bit grayscale (green channel addressing) |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | PLUTO-2.1-TELCO-013 |
| Spectral Range | 1400–1700 nm |
| Resolution | 1920 × 1080 pixels |
| Pixel Pitch | 8 µm |
| Field of View (TFOV) | 15.36 × 8.64 mm |
| Instantaneous Field of View (IFOV) | 7.8 µrad |
| Frame Rate | 60 Hz |
| Modulation Type | Pure-Phase, Liquid-Crystal-on-Silicon (LCoS) |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | PLUTO-2.1-VIS-016 |
| Spectral Range | 420–650 nm |
| Resolution | 1920 × 1080 pixels |
| Pixel Pitch | 8 µm |
| Field of View (TFOV) | 15.36 × 8.64 mm |
| Instantaneous Field of View (IFOV) | 62.5 lp/mm |
| Frame Rate | 60 Hz |
| Interface | USB-controlled gamma calibration + HDMI/DisplayPort video input |
| Operating Mode | Pure-phase modulation via liquid crystal on silicon (LCoS) |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Flame AAS |
| Model | HD-AAS4H |
| Wavelength Range | 185–900 nm |
| Monochromator | Czerny-Turner enhanced optical system |
| Grating Density | 1800 lines/mm |
| Spectral Bandwidth | 0.2 / 0.4 / 1.0 / 2.0 nm (auto-switchable) |
| Wavelength Accuracy | ≤ ±0.1 nm |
| Wavelength Repeatability | ≤ ±0.025 nm |
| Resolution | 0.2 nm (Cu 324.7 nm, 0.2 nm bandwidth) |
| Baseline Drift | 0.003 ABS/30 min (static), 0.005 ABS/15 min (dynamic) |
| Detector | Hamamatsu photomultiplier tube |
| Background Correction | Deuterium lamp |
| Characteristic Concentration (Cu) | 0.025 µg/mL/1% |
| Detection Limit (Cu) | 0.006 µg/mL |
| Precision (RSD) | ≤ 0.5% |
| Atomizer | Titanium 0.5 mm × 100 mm burner head |
| Nebulizer | High-efficiency glass nebulizer with metal cap |
| Spray Chamber | Corrosion-resistant all-plastic chamber |
| Safety System | Real-time acetylene leak detection, flame-out monitoring, gas pressure interlock, automatic shutdown |
| Lamp System | Motorized turret for 4/6/8 lamp positions |
| Data Interface | RS232, USB |
| Software | Windows-compatible AAS control suite with dual-language UI (EN/CN), remote calibration support, GLP-compliant audit trail, multi-format export (CSV, PDF, Excel) |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | CCD-based Multi-Channel Array |
| Focal Length | 400 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 120–800 nm |
| Analog-to-Digital Resolution | 16-bit per pixel |
| Optical Architecture | Paschen-Runge Mount with Rowland Circle Design |
| Vacuum System | Intermittent Vacuum Maintenance |
| Compliance | ASTM E415, ISO 11573, GB/T 4336 (Chinese National Standard for Spark OES) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Instrument Type | Imported |
| Model | AquaLog |
| Wavelength Range (Excitation) | 200–800 nm |
| Wavelength Range (Emission) | 250–800 nm |
| Wavelength Range (Absorption) | 230–800 nm |
| Excitation Monochromator | Dual-grating with automatic order-sorting filter wheel |
| Emission Monochromator | CCD-based spectrometer with 405 g/mm grating (blazed at 250 nm) |
| Spectral Bandwidth (Slit) | 5 nm |
| Spectral Resolution | 0.41 nm/pixel (configurable to 0.82, 1.64, 3.28 nm/pixel) |
| Wavelength Accuracy | ±1 nm |
| Signal-to-Noise Ratio | >20,000:1 (RMS, 350 nm excitation, water Raman peak) |
| Full EEM Acquisition Time | 30 s |
| Full Emission Spectrum Readout Time | 5 ms |
| Detector | TE-cooled back-illuminated CCD |
| Built-in Corrections | Dark current, excitation source drift, excitation/emission spectral response, inner-filter effect, 1st/2nd-order Rayleigh scatter zeroing, Raman peak subtraction |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Aqualog® |
| Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | 5 nm |
| Optical Resolution | 0.58 nm |
| Sensitivity | 20,000:1 (SNR, RMS, water Raman at 350 nm excitation, 30 s integration) |
| Wavelength Accuracy | ±1.0 nm |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DeltaFlex |
| Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | Adjustable from 1 to 64 nm |
| Optical Resolution | 1 nm |
| Detection Sensitivity | Single-Photon Counting |
| Wavelength Accuracy | ±1 nm |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DeltaFlex |
| Dispersion Element | Grating |
| Slit Width (Spectral Bandpass) | 1–64 nm Adjustable |
| Spectral Resolution | 1 nm |
| Sensitivity | Single-Photon Counting |
| Wavelength Accuracy | ±1 nm |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | DeltaFlex |
| Dispersion Element | Grating |
| Instrument Type | Transient Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 1–64 nm |
| Resolution | 1 nm |
| Sensitivity | >3000:1 |
| Wavelength Accuracy | ±0.05 nm |
| Excitation Source | Pulsed Laser Diode / LED System |
| Lifetime Range | <5 ps – 1 s |
| Minimum Acquisition Interval | 1 ms |
| Dead Time | 10 ns |
| Standard Detector | Picosecond PPD Module |
| Optional NIR Detection | up to ~1700 nm |
| Spectral Coverage | 200–1600 nm (with aberration-corrected gratings) |
| Sample Volume | as low as 1 µL |
| Software | Lifetime analysis suite with ≥5-exponential fitting, FRET, anisotropy, and decay-associated spectra (DAS) modules |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | DeltaHUB |
| Core Technology | Time-Correlated Single-Photon Counting (TCSPC) |
| Lifetime Range | 25 ps – 11 s (source-dependent) |
| Excitation Sources | 100 MHz Deltadiode ps-Laser, NanoLED, or SpectraLED |
| Detector | Picosecond Photon-Counting Detector |
| Integrated Platform | TCSPC-HUB Workstation |
| Optional Accessories | Monochromator for Time-Resolved Emission Spectra (TRES), Liquid Nitrogen Cryostat, 400 MPa High-Pressure Liquid Cell |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | DeltaPro |
| Dispersion Element | Grating |
| Slit Width / Spectral Bandpass | Not Specified |
| Resolution | Not Specified |
| Sensitivity | Not Specified |
| Wavelength Accuracy | Not Specified |
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Model | Duetta |
| Wavelength Range (Excitation/Absorption) | 250–1000 nm |
| Wavelength Range (Emission) | 250–1100 nm |
| Slit Width (Spectral Bandpass) | 1–20 nm |
| Optical Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Fluorescence Sensitivity (Water Raman SNR) | ≥6000:1 (350 nm excitation, 5 nm bandwidth) |
| Absorbance Accuracy | ≤±0.02 A |
| Absorbance Range | 0–2 A |
| Spectral Acquisition Rate | ≥510,000 nm/min |
| A-TEEM Mode Acquisition Time | ≤30 s |
| EEM 3D Scan Time | ≤1 s (configurable) |
| Light Source | 75 W Xenon Arc Lamp |
| Detector (Fluorescence) | CCD Array |
| Detector (Absorption) | Silicon Photodiode |
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Duetta |
| Wavelength Range (Fluorescence) | 250–1100 nm |
| Detection Technology | Back-Illuminated CCD |
| Sensitivity (Water Raman S/N) | >6000:1 |
| Dispersion Element | Holographic Grating |
| Slit Width / Spectral Bandpass | Variable, software-controlled |
| Wavelength Accuracy | ±0.5 nm |
| Internal Correction | Automated primary and secondary inner-filter effect compensation |
| Core Technology | A-TEEM™ (Absorbance-Transmitted Excitation-Emission Matrix) |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Duetta |
| Wavelength Range (Fluorescence) | 250–1100 nm |
| Spectral Bandwidth (Slit) | 1–20 nm |
| Optical Resolution | 1 nm |
| Sensitivity (Water Raman RMS) | 6000:1 |
| Wavelength Accuracy | ±1 nm |
| Dispersion Element | Grating |
| Detector | CCD |
| Measurement Modes | Simultaneous Fluorescence & Absorbance |
| A-TEEM™ Capability | Yes |
| Auto Inner-Filter Correction | Yes |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | EasyRatioPro |
| Spectral Dispersion Element | Grating |
| Excitation Wavelength Control | Motorized Dual-Filter Wheel with Precision Filter Positioning |
| Maximum Wavelength Scanning Speed | 500 nm/s |
| Illumination Technology | DeltaRAM™ High-Speed Monochromatic Illumination System |
| Data Acquisition Engine | PAE (Precision Acquisition Engine) |
| Human Interface | WarpDrive™ Ergonomic Control Console |
| Primary Applications | Intracellular Ca²⁺, Na⁺, and pH Ratiometric Imaging |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | EV 2.0 |
| Detector Type | CCD |
| Spectral Range | 200–1050 nm |
| Dynamic Range | >3000:1 |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FHR1000 |
| Application System | Universal |
| Grating Mount | Dual-Grating Turret |
| Spectral Resolution | 0.010 nm |
| Dispersion | 0.8 nm/mm |
| F-number | f/9.0 |
| Focal Length | 1000 mm |
| Wavelength Accuracy | ±0.05 nm |
| Wavelength Repeatability | ±0.015 nm |
| Maximum Scanning Speed | >300 nm/s |
| Grating Dimensions | Single grating: 110 mm × 110 mm |
| Dual-grating configuration | 80 mm × 110 mm each |
| Stray Light | <1×10⁻⁶ (typical, per ISO 14785) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | FHR640 / FHR1000 |
| Focal Length | 640 mm (FHR640) / 1000 mm (FHR1000) |
| f-number | f/5.4 (FHR640) / f/9.0 (FHR1000) |
| Spectral Resolution | 0.016 nm (FHR640) / 0.010 nm (FHR1000) |
| Spectral Dispersion | 1.2 nm/mm (FHR640) / 0.8 nm/mm (FHR1000) |
| Grating Size | 110 × 110 mm (single) / 80 × 110 mm (dual) |
| Wavelength Accuracy | ±0.05 nm |
| Wavelength Repeatability | ±0.015 nm |
| Scan Speed | >300 nm/s |
| Optical Design | Monolithic cast aluminum body with in-axis grating scanning mechanism |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | FHR640/FHR1000 |
| Focal Length | 640 mm (FHR640) / 1000 mm (FHR1000) |
| f-number | f/5.4 (FHR640) / f/9.0 (FHR1000) |
| Spectral Resolution | 0.016 nm (FHR640) / 0.010 nm (FHR1000) |
| Linear Dispersion | 1.2 nm/mm (FHR640) / 0.8 nm/mm (FHR1000) |
| Wavelength Accuracy | ±0.05 nm |
| Wavelength Repeatability | ±0.015 nm |
| Scanning Speed | >300 nm/s |
| Grating Mount | Dual-grating turret (up to two 110×110 mm or 80×110 mm gratings) |
| Output Ports | Dual simultaneous exit ports |
| Structural Design | Monolithic aluminum cast housing |