Spectroscopy Instruments
Filter
Showing 991–1020 of 2562 results
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | PG2000-Pro |
| Price | Upon Request |
| Spectral Range | 200–1100 nm |
| Detector Type | Back-Illuminated CCD |
| Optical Resolution (FWHM) | 0.18–7.05 nm |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | PG4000 |
| Spectral Range | 200–1100 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 0.10–4.88 nm |
| System Sensitivity | 2 × 10⁸ |
| Single-Scan Dynamic Range | 1300:1 |
| Signal-to-Noise Ratio (SNR) | >400:1 (at saturation) |
| Overall Dynamic Range | >3000:1 |
| Stray Light | <0.1% (measured at 600 nm) |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SINO |
| Optical Resolution (FWHM) | Up to 0.3 nm (dependent on grating and slit selection) |
| Detector Options | CMOS or CCD |
| Slit Width Options | 10–200 µm |
| Pixel Count | 4096 pixels |
| Maximum Acquisition Rate | 2000 frames per second (fps) |
| Physical Dimensions | 92 × 66 × 34 mm³ |
| Focal Length | 42 mm |
| Thermal Drift Stability | ~0.15 pixel/°C |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TEMBO-300 |
| Pricing | Available Upon Request |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | ZURO |
| Detector Type | CCD |
| Spectral Range | 200–980 nm |
| Optical Resolution | 0.77 nm (FWHM) |
| Signal-to-Noise Ratio | 1000:1 (typical), up to 3000:1 in nonlinear region |
| Dynamic Range | 25,000:1 |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | ImSpector |
| Spectral Range (Standard Config) | 380–800 nm (V8) / 400–1000 nm (V10) |
| Slit Width | 50 µm (25/80/150 µm optional) |
| Slit Length | 9.6–9.8 mm |
| Relative Aperture | f/2.8 |
| Optical Design | Transmissive Grating-Based Push-Broom Imaging |
| Image Plane Size | 4.3 × 6.6 mm or 6.6 × 8.8 mm |
| Spatial Resolution | <30 µm RMS (V8), <40 µm RMS (V10) |
| Spectral Resolution | 6–11.2 nm |
| Stray Light | <0.5% |
| Throughput Efficiency | >50% |
| Housing Material | Anodized Aluminum |
| Dimensions | Ø35 × 139 mm |
| Weight | 300 g |
| Interface | Standard C-Mount |
| Optical Aberration Control | Optimized for minimal astigmatism, pincushion (<30–45 µm), and trapezoidal distortion (<20–40 µm) |
| Brand | INESA |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Flame and Graphite Furnace Atomic Absorption Spectrophotometer |
| Compliance | Meets ISO 11171, ASTM D5185, USP <731>, and GB/T 21187–2007 for AAS methodology |
| Detection Limits | Sub-pptr range for most elements (e.g., Cd: 0.002 µg/L, Pb: 0.02 µg/L in flame mode |
| Cd | 0.1 pg, Pb: 0.5 pg in GF mode) |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1, 0.2, 0.4, 1.0, 2.0 nm selectable |
| Light Source | Hollow Cathode Lamps (HCLs) and Electrodeless Discharge Lamps (EDLs) |
| Detector | High-sensitivity photomultiplier tube (PMT) |
| Data Output | USB 2.0, RS-232, optional Ethernet interface |
| Software | AAWinLab v3.2 with audit trail, user permission levels, and 21 CFR Part 11 compliance modules |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Pricing | Upon Request |
| Instrument Category | Spectral Software & Reference Database |
| Brand | Innoteg |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | InnoFTIR10 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | Better than 1.0 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 45,000:1 (peak-to-peak, 2100 cm⁻¹, 4 cm⁻¹ resolution, 1-minute acquisition) |
| Beam Diameter | 10 mm |
| Beamsplitter | Imported multi-layer germanium-coated KBr, Ø60 mm with anti-humidity coating |
| Source | Imported high-intensity air-cooled ceramic IR source |
| Detector | Imported low-noise deuterated triglycine sulfate (DLATGS) detector |
| Interferometer | Oscillating-mirror interferometer (space-derived optical architecture) |
| Baseline Flatness | ≤0.1% T |
| Dimensions (W×D×H) | ≥590 × 355 × 185 mm |
| Sample Compartment Size (W×D×H) | ≥200 × 255 × 150 mm |
| Weight | 26 kg |
| Interface | USB |
| Power Supply | AC 220 V / DC 12 V, 40 W |
| Operating System | Windows 10 (64-bit or later) |
| Ambient Temperature | 15–28 °C |
| Relative Humidity | <65% RH (non-condensing) |
| Optional Features | N₂ purge port, built-in desiccant chamber with visual indicator, heater-assisted humidity control, adjustable interferometer energy output |
| Brand | Innoteg |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | InnoFTIR15 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | <1.0 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 30,000:1 (peak-to-peak, 2100 cm⁻¹, 4 cm⁻¹ resolution, 60 s acquisition) |
| Beam Diameter | 15 mm |
| Beamsplitter | Multi-layer Ge-coated KBr (imported) |
| Source | High-intensity air-cooled ceramic IR source (imported) |
| Interferometer | Michelson-type, self-compensating, automated alignment |
| Detector | Low-noise deuterated triglycine sulfate (DLATGS) detector (imported) |
| Baseline Flatness | ≤0.1% T |
| Measurement Modes | Transmittance, Absorbance, Radiant Energy |
| Dimensions (W×D×H) | 486 × 406 × 230 mm |
| Sample Compartment Size | 200 × 170 × 145 mm |
| Weight | 23 kg |
| Interface | USB 2.0 |
| Power Supply | AC 220 V / DC 12 V, 40 W |
| OS Compatibility | Windows 10 (64-bit or later) |
| Operating Environment | 15–28 °C, RH <65% (non-condensing) |
| Brand | Innoteg |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | InnoFTIR15C |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 4000–400 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 15,000:1 (at 4 cm⁻¹ resolution, 1 min scan) |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Optical System | Michelson Interferometer with KBr Multilayer Beam Splitter (Ge-coated, anti-humidity) |
| Detector | High-Sensitivity DLATGS |
| Source | High-Intensity Air-Cooled Ceramic IR Source |
| Enclosure | Electromagnetically Shielded Metal Housing |
| Included Accessory | Integrated Desiccant Dry Box |
| Software | Building Glass Compliance Suite (GB/T 2680–2021, JGJ/T 151–2008 compliant) |
| Spectral Range | 190–3200 nm |
|---|---|
| Bandwidth (UV-VIS) | 0.2, 0.5, 1, 2, 3, 5 nm |
| Bandwidth (NIR) | 0.8, 2, 4, 8, 12, 20 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Brand | INNOTEG |
|---|---|
| Origin | China |
| Manufacturer Type | Manufacturer |
| Model | IUS-190 |
| Spectral Range | 190–3200 nm |
| Bandwidth (UV-VIS) | 0.2, 0.5, 1, 2, 3, 5 nm |
| Bandwidth (NIR) | 0.8, 2, 4, 8, 12, 20 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | IUS-200-10 |
| Spectral Range | 280–2500 nm |
| Slit Bandwidth | UV-VIS: 0.2, 0.5, 1, 2, 3, 5 nm |
| NIR | 0.8, 2, 4, 8, 12, 20 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | IUS-200-15 |
| Spectral Range | 280–2500 nm |
| Slit Bandwidth | UV-VIS: 0.2, 0.5, 1, 2, 3, 5 nm |
| NIR | 0.8, 2, 4, 8, 12, 20 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Integrating Sphere Diameter | 150 mm |
| Optical Design | Dual-beam, dual-grating, dual-detector architecture |
| Detector Configuration | Separate optimized detectors for UV/VIS and NIR ranges |
| Software Compatibility | Windows 7/10 |
| Data Export Formats | TXT, CSV, XLSX |
| Compliance Standards | GB/T 2680-2021, JGJ/T 151-2008, ISO 9050:2003, GB/T 22476-2008, GB/T 36261-2018, GB/T 25261-2010, JG/T 235-2014, JGJ/T 287-2014, GJB 798-90, GJB 2502.2-2006 |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | IUS-200-6 |
| Spectral Range | 280–2500 nm |
| Slit Bandwidth | [UV-VIS] 0.2, 0.5, 1, 2, 3, 5 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Brand | INSA Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 8000–350 cm⁻¹ (extendable to 12800–4000 cm⁻¹ in NIR |
| Spectral Resolution | 0.2 cm⁻¹ |
| Scan Speed | 2.5–60 kHz |
| Signal-to-Noise Ratio (SNR) | 40,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Wavenumber Accuracy | < ±0.1 cm⁻¹ |
| Vacuum Level | ≤ 0.2 mbar |
| Optical Design | All-metal vacuum-sealed cast-aluminum interferometer housing with independent optical chamber |
| Brand | INSION |
|---|---|
| Origin | Germany |
| Model | 2C UV VIS |
| Optical Architecture | Single-beam |
| Detector Type | Photodiode Array |
| Spectral Range | 2 × 350–1050 nm |
| Wavelength Accuracy | < 10 nm FWHM |
| Spectral Resolution | < 10 nm FWHM |
| Sensitivity | > 2.0 × 10¹⁵ counts·nm/W·s at 650 nm |
| Optical Interface | Dual SMA 905 connectors |
| Calibration | Factory-calibrated, no user recalibration required |
| Mechanical Stability | Solid-state design, no moving parts |
| Operating Temperature Range | 5–40 °C |
| Dimensions | ≤ 65 × 45 × 25 mm |
| Weight | < 120 g |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | InverTau |
| Pricing | Upon Request |
| Dispersive Element | Filter-Based |
| Resolution | 4096 × 4096 |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | IQ-Thermo |
| Pricing | Upon Request |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Deployment Mode | Ground-based |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 7 nm |
| Spatial Resolution (IFOV) | 512 pixels |
| Field of View (TFOV) | 31° |
| LWIR Band | 7.5–13.5 µm |
| IR Detector Resolution | 640 × 512 px |
| Thermal Sensitivity | ≤0.03 °C (30 mK) @ 30 °C |
| Temperature Range Options | −25 to +150 °C or +40 to +550 °C (optional up to +1500 °C) |
| Frame Rate Options | 9 / 30 / 60 Hz |
| Optical Aperture | f/1.7 |
| Spectral Bands | 204 (with optional binning: 2× or 3×) |
| GPS Integration | Yes (geotagged data cubes) |
| Enclosure Rating | IP65 |
| Data Interfaces | USB 3.0, GigE, Wi-Fi |
| Output Formats | CSV, radiometric JPEG, non-radiometric JPEG, radiometric video, AVI, MP4 |
| Software Features | SAM algorithm, ROI temperature profiling, isotherm mode, thermal 3D surface mapping, report generation |
| Brand | Spectrolight |
|---|---|
| Origin | Switzerland |
| Model | IRsweep IRis-F1 |
| Instrument Type | Laboratory Benchtop Laser-Based Infrared Spectrometer |
| Light Source Technology | Dual Quantum Cascade Laser (QCL) Frequency Comb |
| Time Resolution | 1 µs |
| Spectral Resolution | 0.25–0.5 cm⁻¹ |
| Spectral Range | Mid-Infrared (Typical 1,200–3,000 cm⁻¹, configurable) |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Software Environment | IRsweep Control Suite v4.x (Windows-based, FDA 21 CFR Part 11-ready audit trail option) |
| Brand | IRsweep |
|---|---|
| Origin | Switzerland |
| Model | IRis-F1 |
| Technology | Dual-Comb Quantum Cascade Laser (QCL) Infrared Spectroscopy |
| Time Resolution | 1 µs |
| Spectral Resolution | 0.25–0.5 cm⁻¹ |
| Spectral Range | Mid-IR (typically 1200–2200 cm⁻¹, configurable) |
| SNR | High (optimized for trace-level detection) |
| Sample Compatibility | Solid, Liquid, Gas |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Model | IsoPlane SCT-320, IsoPlane 160 |
| Focal Length | 320 mm (SCT-320), 203 mm (160) |
| Aperture Ratio | f/4.6 (SCT-320), f/3.88 (160) |
| Spectral Resolution (PMT) | 0.05 nm (SCT-320), 0.10 nm (160) |
| Spectral Resolution (CCD, 1200 gr/mm, 435 nm, 20 µm pixels, 10 µm slit) | 0.08 nm (SCT-320), 0.15 nm (160) |
| Grating Mount | Motorized triple-grating turret with auto-recognition |
| Wavelength Range | UV to mid-IR (193 nm–>5 µm, depending on grating & detector) |
| Optical Coating Options | Acton #1900 enhanced Al (193 nm–mid-IR), protected Ag (>98% avg. reflectance), Au (NIR/SWIR) |
| Detector Compatibility | PIXIS, ProEM, PI-MAX4, NIRvana series |
| Software Platform | LightField v8+ (64-bit), supports LabVIEW, MATLAB, EPICS, and FDA 21 CFR Part 11-compliant audit trail modules |
| Brand | ISPEC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | Analytical System |
| Quotation | Upon Request |
| Instrument Category | Spectral Software & Database Suite |
| Instrument Type | Laboratory-Based |
| Wavenumber Range | 4000–400 cm⁻¹ |
| Resolution | 1 cm⁻¹ |
| Brand | Bunkoukeiki (Japan) |
|---|---|
| Origin | Japan |
| Model | IUV-25CP-1 |
| Wavelength Range | ~240 nm (continuous irradiation band) |
| Irradiation Area (Vertical) | 89 mm (5–13 adjustable steps) |
| Irradiation Area (Wavelength Direction) | 80 mm (~240 nm spectral span) |
| Exposure Time | 0.01–1200 s |
| Exposure Steps | 1–13 |
| Light Sources | Deep UV Mercury Lamp (line spectrum) + Xenon Arc Lamp (broadband continuum) |
| Brand | IVEA |
|---|---|
| Origin | France |
| Model | easyLIBS |
| Instrument Type | Handheld |
| Integration | Modular |
| Laser Source | Dual-Pulse Nd:YAG, 1064 nm |
| Spot Size | ~300 µm |
| Detection Limit | 1–500 ppm (element-dependent) |
| Weight (system with case) | <7 kg |
| Power Supply | Integrated portable battery pack |
| Software | AnaLIBS (included on dedicated laptop) |
| Optical Collection | Co-aligned laser focusing & plasma signal collection optics |
| Imaging | Built-in CMOS camera for real-time sample surface visualization |
| Fiber Spectrometer Options | User-selectable, multiple wavelength ranges available |
| Brand | IVEA |
|---|---|
| Origin | France |
| Model | MEEPLIBS |
| Instrument Type | Online LIBS System |
| Integration | Fully Integrated |
| Spatial Resolution | Down to 4 µm (Standard Apertures: 15 µm and 18 µm) |
| Operating Environment | Ambient Air at Room Temperature (Configurable for Controlled Atmospheres) |
| Laser Source | Q-Switched Nd:YAG, 266 nm UV, Software-Tunable Pulse Energy with Beam Shaping & Attenuation |
| Sample Handling | Motorized XYZ Translation Stage with Real-Time CCD Imaging Feedback |
| Elemental Coverage | H to U (All Elements, Including Light Elements) |
| Sample Preparation | None Required |
| Brand | IVEA |
|---|---|
| Origin | France |
| Model | YAG 266 nm, 20 Hz |
| Form Factor | Benchtop |
| Integration | Fully Integrated |
| Laser Type | Q-switched Nd:YAG (4th harmonic) |
| Wavelength | 266 nm |
| Repetition Rate | 20 Hz |
| System Architecture | Modular (4 units, ~30 kg each) |
| Sample Compatibility | Solids, Liquids, Gases, Opaque & Transparent Materials |
| Optical Path | Motorized Focus Adjustment |
| Detection Range | Typically 190–850 nm (configurable per spectrometer module) |
| Compliance | CE-marked, RoHS-compliant |
| Brand | J&M |
|---|---|
| Origin | Germany |
| Model | MSP-400 |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 400–800 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | 0.001% T |
| Automation Level | Automatic Wavelength Scanning |
| Compatibility | Integrates with microscope camera tubes via TIDA interface |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CPL-300 |
| Pricing | Upon Request |