| Brand | ASD |
|---|---|
| Origin | USA |
| Model | LabSpec 4 Hi-Res |
| Wavelength Range | 350–2500 nm |
| Spectral Resolution | 6 nm @ 1400/2100 nm (Hi-Res) / 10 nm @ 1400/2100 nm (Standard) |
| Scan Time | 100 ms |
| SNR | VNIR 9000:1 @ 700 nm, SWIR1 9000:1 @ 1400 nm, SWIR2 4000:1 @ 2100 nm |
| Detector Configuration | 512-pixel Si array (350–1000 nm) + dual TE-cooled InGaAs arrays (1000–1800 nm & 1800–2500 nm) |
| Certifications | CE (EN 61010-1:2001), EU Directive 2006/95/EC & 2004/108/EC, NIST-traceable calibration |
| Software Compatibility | Indico® Pro, GRAMS (Thermo Scientific), The Unscrambler® (Camo) |
| Connectivity | 10/100Base-T Ethernet, IEEE 802.11g Wi-Fi (up to 300 m line-of-sight) |
| Power | 12 VDC NiMH battery (6 h typical operation), AC/DC adapter (90–240 VAC, 50/60 Hz) |
| Dimensions | 12.7 × 35.6 × 29.2 cm |
| Weight | 5.2 kg (with battery) |
| Brand | ASD |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QualitySpec Trek |
| Price | Upon Request |
| Wavelength Range | 350–2500 nm |
| Spectral Resolution | 3 nm @ 700 nm, 9.8 nm @ 1400 nm, 8.1 nm @ 2100 nm |
| Dimensions (L×W×H) | 775 mm × 250 mm × 750 mm |
| Weight with Battery | 2.5 kg (5.5 lbs) |
| Weight without Battery | 2.0 kg (4.3 lbs) |
| Operating Languages | English, Spanish, Chinese |
| Integrated GPS | Yes |
| Voice Memo Function | Yes |
| Display | Integrated LCD |
| Connectivity | Wireless (Wi-Fi/Bluetooth) |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | TerraSpec 4 Hi-Res |
| Wavelength Range | 350–2500 nm |
| Spectral Resolution | 3 nm @ 700 nm, 6 nm @ 1400/2100 nm |
| Scan Speed | 100 ms |
| SNR | VNIR 9000:1 @ 700 nm, SWIR1 9000:1 @ 1400 nm, SWIR2 4000:1 @ 2100 nm |
| Stray Light | VNIR 5000:1 (0.02%), NIR 10000:1 (0.01%) |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Accuracy | ±0.5 nm |
| Detector | 512-pixel Si array (350–1000 nm), TE-cooled InGaAs gradient-index arrays (1001–1800 nm & 1801–2500 nm) |
| Interface | 10/100 Base-T Ethernet, 802.11g Wi-Fi |
| Dimensions (H×W×D) | 12.7 × 36.8 × 29.2 cm |
| Weight | 5.44 kg (instrument), +1.2 kg (battery) |
| Battery Life | ~6 h (standalone) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −15–45 °C |
| Power Input | 90–240 VAC / 50–60 Hz or 12 VDC / 60 W |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | TerraSpec 4 Hi-Res |
| Spectral Range | 350–2500 nm |
| Detector | InGaAs |
| Resolution | 3 nm @ 700 nm |
| Sensitivity | 75 photons/count |
| SNR | VNIR 9000:1 @ 700 nm |
| SWIR1 9000 | 1 @ 1400 nm |
| SWIR2 4000 | 1 @ 2100 nm |
| Dynamic Range | 7.5×10⁹ |
| Stray Light | VNIR 5000:1 (0.02%) |
| NIR 10000 | 1 (0.01%) |
| Brand | ASD |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | TerraSpec Halo |
| Pricing | Upon Request |
| Brand | ASD |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Halo |
| Instrument Type | Portable |
| Application Field | General (Universities, Research Institutes) |
| Operating Principle | Grating-Based Array Detector (Non-Scanning) |
| Wavelength Range | 350–2500 nm |
| Scan Speed | 10 spectra/sec |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | ASD Halo Manager |
| Spectral Resolution | 3 nm @ 700 nm, 9.8 nm @ 1400 nm, 8.1 nm @ 2100 nm |
| Dimensions (L×W×H) | 775 × 250 × 750 mm |
| Weight (with battery) | 2.5 kg (5.5 lbs) |
| Weight (without battery) | 2.0 kg (4.3 lbs) |
| Supported Languages | English, Spanish, Chinese |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aurora |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Benchtop |
| Integration Level | Fully Integrated |
| Laser Pulse Energy | 200 mJ (at 1064 nm, 5 ns FWHM) |
| Repetition Rate | Up to 100 Hz |
| Spectral Range | 190–1000 nm |
| Optical Resolution | ≤ 0.07 nm (FWHM at 300 nm) |
| Detector | Back-illuminated, deep-depletion CCD with thermoelectric cooling to −60 °C |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | J200 |
| Price Range | USD 13,500 – 40,500 (est.) |
| Instrument Type | Benchtop |
| Integration | Modular |
| Laser Pulse Energy | 200 mJ per pulse at 1064 nm |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | J200-1 |
| Instrument Type | Benchtop |
| Integration | Modular |
| Laser Pulse Energy | 200 µJ (at 800 nm, 1 kHz) |
| Motion Stage | X-Y travel range 100 mm × 100 mm, positioning resolution 0.2 µm |
| Spectrometer | Czerny–Turner optical design |
| Detector | Intensified CCD (ICCD) |
| Certification | CE |
| Optional Upgrade | Tandem LA Configuration |
| Power Supply | 110–240 VAC, 50/60 Hz, 5 A (10 A fuse) |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | J200-2 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Pulse Energy | 200 µJ (at 800 nm, 1 kHz) |
| Laser Pulse Duration | <500 fs |
| Repetition Rate | 1–1000 Hz (software-adjustable) |
| Wavelength | 800 nm (fundamental), optionally tunable via OPA |
| Imaging | Wide-field optical view + high-magnification telecentric microscope (up to 100×) |
| Gas Control | Digital mass flow controllers (MFCs) for Ar, He, and auxiliary gases |
| Compatibility | Quadrupole ICP-MS, multi-collector ICP-MS, and time-of-flight ICP-MS |
| Brand | ASI |
|---|---|
| Origin | USA |
| Model | J200-3 |
| Form Factor | Benchtop |
| Integration | Fully Integrated |
| Laser Wavelength | 213 nm (Q-switched Nd:YAG) |
| Pulse Energy | 200 mJ (adjustable) |
| Dual-Spectrometer Capability | LIBS + Optional ICP-MS Interface |
| Depth Profiling Resolution | Sub-micron per pulse (dependent on ablation rate and matrix) |
| Sample Chamber | Flex™ Modular Vacuum-Compatible Chamber with Interchangeable Liners |
| Gas Control | Dual High-Precision Digital Mass Flow Controllers (MFCs) |
| Imaging | Co-registered Dual-Camera System (High-Magnification Microscope + Wide-Field Surface View) |
| Brand | ASI |
|---|---|
| Origin | USA |
| Type | Benchtop |
| Configuration | Modular |
| Laser Wavelength | 193 nm (Excimer) |
| Pulse Energy | 200 mJ (typical, at laser output) |
| Fluence | >20 J/cm² |
| Sample Stage Travel Range | 155 mm × 105 mm |
| Sample Capacity | 20 × 1-inch targets or 6 thin sections |
| Dimensions (W×D×H) | 119 × 89 × 195 cm |
| Weight | 750 kg (1600 lbs.) |
| Flush Time | Optimized for rapid washout (<30 s typical for standard ablation cells) |
| Brand | ATS |
|---|---|
| Origin | Switzerland |
| Model | ATS 200S |
| Detection Elements | Na, K, Li, Ca (standard) |
| Measurement Range | Na/K/Li/Ca: 0–200 ppm |
| Ba | 50–1000 ppm |
| Units | ppm, mmol/L, mEq/L |
| Sensitivity | 0.4 ppm (Na, K) |
| Detection Limit | 0.2 ppm (Na, K) |
| Linearity | Natural logarithmic linearity (R² > 0.999 over full range) |
| Repeatability | ≤1% CV (n=10) |
| Drift | ≤1% over 30 min |
| Calibration | One-touch auto-zero and multi-point calibration |
| Operating Temperature | 15–36 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Dimensions (Analyzer) | 320 × 400 × 400 mm (L×W×H) |
| Net Weight (Analyzer) | 9 kg |
| Air Compressor Dimensions | 340 × 250 × 350 mm |
| Net Weight (Compressor) | 6 kg |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible operation |
| Software Interface | USB 2.0, RS-232, optional Ethernet module |
| Brand | ATS |
|---|---|
| Origin | Switzerland |
| Model | 300GM |
| Spectral Dispersion | Grating and Interference Filters |
| Slit Width (Spectral Bandpass) | 1.5 nm |
| Resolution | 1 nm |
| Sensitivity | 200:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±2 nm |
| Detection Range | 1–800 ppm U |
| Precision | ≤1% CV at 100 ppb U |
| Measurement Cycle Time | 5 s |
| Display | Backlit LCD/LED |
| Interface | RS-232, USB 2.0 |
| Power Supply | ATS/37009: 230 VAC, 50/60 Hz |
| ATS/37010 | 110 VAC, 60 Hz |
| Dimensions | 420 × 280 × 380 mm (L×W×H) |
| Net Weight | 9 kg |
| Brand | ATS |
|---|---|
| Origin | Switzerland |
| Model | ATS 200S/40998 |
| Measurement Principle | Atomic Emission Spectrometry (Flame Photometry) |
| Elements Measured (Standard) | Na, K, Ca, Mg |
| Optional Channels | Ba or custom single-element channel |
| Measurement Units | ppm, mmol/L, mEq/L |
| Linear Range | Na/K/Ca 0–200 ppm |
| Detection Limit | 0.2 ppm (Na, K) |
| Sensitivity | 0.4 ppm (Na, K) |
| Precision | ≤1% CV (n=10) |
| Drift | ≤1% over 30 min |
| Fuel Gases | Butane, Propane, LPG |
| Air Supply | Oil-free, water-free, particle-free compressed air with buffer tank |
| Optical Design | Fixed interference filters (non-movable) |
| Calibration | Automatic zeroing + single-point memory calibration |
| Software | ATS MiniSoftWin™ (GLP-compliant reporting, multi-point calibration curve generation, method/data archiving, ISO/IEC 17025 report templates) |
| Brand | Attocube Systems AG |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Confocal Raman Microscope |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | <1 cm⁻¹/pixel (with 1800 lines/mm grating) |
| Spatial Resolution | <400 nm (at 532 nm excitation) |
| Minimum Detectable Raman Shift | 10 cm⁻¹ |
| Spectral Reproducibility | ±0.1 cm⁻¹ (typical, after spectral calibration) |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Ci4200 / Ci4200UV |
| Pricing | Available Upon Request |
| Optical Geometry | d/8° with DRS (Diffuse/8°) |
| Illumination/Measurement Aperture | 14 mm / 8 mm |
| Light Source | Tungsten-Halogen Lamp + UV LEDs (Ci4200UV only) |
| Detector | Blue-Enhanced Silicon Photodiode |
| Spectral Range | 400–700 nm |
| Spectral Interval | 10 nm (acquisition & output) |
| Reflectance Range | 0–200% |
| Inter-instrument Agreement | Avg. ΔE*ab ≤ 0.20 (BCRA Series II, SCI mode), Max. ΔE*ab ≤ 0.40 per tile |
| Short-Term Repeatability | ≤ 0.05 ΔE*ab (white tile) |
| Measurement Time | ~2 s (simultaneous SCI/SCE) |
| Gloss Measurement | 60° |
| UV Calibration Function | Yes |
| Transform Support | Yes |
| LED Status Panel & Remote Trigger via Measuring Button | Yes |
| Sample Fixture | Positionable & Preview-Capable |
| Mounting Flexibility | Horizontal & Vertical Orientation |
| Data Compatibility | Cross-platform with portable integrating sphere instruments |
| Lamp Lifetime | ~500,000 measurements |
| Power Supply | 90–130 VAC or 100–240 VAC, 50–60 Hz, ≤15 W |
| Interface | USB |
| Operating Temp. | 10–40 °C (50–104 °F), ≤85% RH (non-condensing) |
| Storage Temp. | −20–50 °C (−4–122 °F) |
| Weight | 5.2 kg (11.5 lbs) |
| Dimensions | 221 mm (H) × 190 mm (W) × 264 mm (D) |
| Standard Accessories | Black trap, white & green calibration tiles, UV calibration standard (Ci4200UV), user manual, AC adapter, USB cable |
| Brand | Auniontech (distributor of GGB Industries) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | GGB Industries, USA |
| Type | Coaxial Millimeter-Wave On-Wafer Probe |
| Frequency Range | 750–1100 GHz (D-Band) |
| Impedance | 50 Ω |
| Tip Configuration | Coplanar Spring-Loaded Beryllium-Copper |
| DC Bias Capability | Up to 100 mA |
| Optical Alignment | Integrated Tip Viewing Port |
| Compliance | Designed for ASTM F2683, IEEE Std 145-2013, and ISO/IEC 17025-compliant on-wafer RF characterization workflows |
| Optional Accessories | Bias-T modules, probe positioning stages, calibration substrates (Si/SiO₂, quartz), and WR-0.8 waveguide interfaces |
| Brand | Auniontech |
|---|---|
| Model | TeraCube Scientific |
| Type | THz Near-Field Scanning Microscope |
| Core Technology | Electro-optic Sampling-Based Terahertz Time-Domain Near-Field Imaging |
| Probe Type | TeraSpike THz Microprobe |
| Automation Level | Fully Motorized XYZ + Tip-Sample Distance Control |
| Laser Source Compatibility | Ti:sapphire Oscillator-Amplifier System (800 nm, <100 fs) |
| Detection Method | Lock-in Amplified Electro-optic Sampling |
| Spatial Resolution | Sub-wavelength (≤ λ/10, ~3–5 µm at 0.3–1 THz) |
| Dynamic Range | >60 dB (typical, system-limited) |
| Scan Range | Up to 100 × 100 µm² (high-res mode), 1 × 1 mm² (wide-field mode) |
| Sample Environment | Ambient air or purged N₂ (optional) |
| Compliance | CE Marked |
| Safety Class | Integrated Class 3B Laser Enclosure with Interlock System |
| Data Export | ASCII (.txt), MATLAB (.mat), HDF5 |
| Brand | Aurora |
|---|---|
| Origin | USA |
| Model | 1200 Plus |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman and D₂ Lamp (1 kHz, Smith-Hieftje mode) |
| Wavelength Range | 185–900 nm |
| Atomizer Temperature Range (GFAAS) | Room Temperature to 3000 °C (programmable) |
| Heating Rate (GFAAS) | Up to 3800 K/s |
| Auto-sampler | Optional XYZ Robotic Sampler with On-line Pre-concentration (up to 100×) |
| Lamp Mount | 6-position Rotating Lamp Tower (4 standard + 2 high-intensity lamp power supplies) |
| Software Compliance | FDA 21 CFR Part 11–ready audit trail, electronic signature support, GLP/GMP data integrity features |
| Key | Origin: USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aurora LIBS |
| Price Range | USD 14,000 – 42,000 (FOB) |
| Instrument Type | Benchtop |
| Integration Architecture | Modular |
| Laser Pulse Energy | 200 mJ @ 1064 nm |
| Spectral Range | 190–1050 nm (UV-VIS-NIR) |
| Spectral Resolution | ≤ 0.07 nm (FWHM) |
| Gating Delay Precision | ≥ 50 ns resolution, < 1 ns jitter |
| Z-Axis Travel | 35 mm, Positioning Resolution: 0.5 µm |
| Optical Illumination | Coaxial Reflectance LED, Transmitted Light Source, Orthogonal Crosshair Targeting |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaRaman Bundles |
| Instrument Type | Portable Raman Spectrometer |
| Spectral Range | 100–3600 cm⁻¹ |
| Spectral Resolution | 6 cm⁻¹ |
| Laser Excitation | 785 nm integrated |
| Detector Platform | AvaSpec-ULS2048x64TEC-EVO-RS or AvaSpec-ULS2048CL-EVO-RS (TE-cooled CCD) |
| Slit Options | 25 µm |
| Fiber Connector | FC/PC |
| Software | Panorama-Light with AvaRaman module |
| Compliance | CE, RoHS, FDA 21 CFR Part 11-ready (audit trail & user access control enabled) |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSolar |
| Spectral Range | 300–2500 nm |
| Detector Type | Back-illuminated CCD & InGaAs array |
| Spectral Resolution | 0.5–20 nm (model-dependent) |
| Optical Dynamic Range | 3800:1 |
| Signal-to-Noise Ratio | 450:1 to 5000:1 (wavelength-dependent) |
| Stray Light | <0.3% to <0.5% |
| Wavelength Accuracy | ±0.3 nm (UV-VIS), ±1.5–3.0 nm (NIR-SWIR) |
| Pixel Resolution | 2048-pixel CCD (14 × 500 µm) / 256-pixel TE-cooled InGaAs |
| Integration Time | 2 µs – 20 s |
| Linearity | >99% (nonlinear calibration applied) |
| Calibration Traceability | NIM (National Institute of Metrology, China), U = 8.0% (k=2) |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-HS2048XL-EVO |
| Spectral Range | 200–1160 nm |
| Detector | Back-Illuminated CCD (2048 pixels) |
| Resolution (FWHM) | 1–20 nm (configuration-dependent) |
| Sensitivity | 1,250,000 counts/µW·ms |
| Signal-to-Noise Ratio | 525:1 |
| Stray Light | < 1% |
| Dynamic Range | 200–1160 nm |
| Numerical Aperture | 0.22 |
| Focal Length | 37.5 mm |
| Integration Time | 2 µs – 600 s |
| A/D Conversion | 16-bit, 1 MHz |
| Interface | USB 3.0 (5 Gbps) / Gigabit Ethernet (1 Gbps) |
| Data Acquisition Rate | 2.44 ms per scan (with on-board averaging) |
| Digital I/O | HD-26 connector with 2 analog inputs, 2 analog outputs, 3 digital inputs, 12 digital outputs, trigger & sync support |
| Power Supply | USB-powered (700 mA) or external 12 VDC (360 mA) |
| Dimensions & Weight | 175 × 165 × 85 mm, 1.95 kg |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-HSC1024x58TEC-EVO |
| Spectral Range | 200–1160 nm |
| Detector | Back-Illuminated CCD |
| Resolution (FWHM) | 0.2–7 nm (configurable) |
| Sensitivity | 445,000 counts/µW per ms integration time |
| Signal-to-Noise Ratio | 1200:1 |
| Dynamic Range | 40,000 |
| Stray Light | 0.5% |
| Optical Platform | Symmetrical Czerny-Turner, f = 100 mm, NA = 0.13 |
| Cooling | Single-stage thermoelectric (TEC) |
| ADC | 16-bit, 250 kHz |
| Integration Time | 5.2 ms – 60 min |
| Interfaces | USB 3.0 (5 Gbps), Gigabit Ethernet (1 Gbps), HD-26 I/O connector |
| Dimensions | 185 × 161 × 185 mm |
| Weight | 3500 g |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-NIR-Mini |
| Spectral Range | 900–1750 nm |
| Detector | InGaAs (256-pixel array) |
| Optical Resolution | 6 nm (typical, slit- and grating-dependent) |
| Sensitivity (HS mode) | 665,000 counts/µW/ms (integrated over 1000–1750 nm) |
| Signal-to-Noise Ratio (HS) | 1900:1 |
| Dynamic Range (HS) | 4750:1 |
| Stray Light | <1% |
| A/D Converter | 16-bit, 500 kHz |
| Integration Time (HS) | 10 µs – 300 ms |
| Interface | USB 2.0 (480 Mbps), fiber-coupled input, 50 cm integrated cable |
| Dimensions | 95 × 68 × 20 mm |
| Weight | 185 g |
| Operating Temperature | 0–55 °C |
| Software Compatibility | AvaSoft v8+, Windows/Linux DLL support |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-NIR256-1.7-EVO |
| Wavelength Range | 900–1750 nm |
| Scan Speed | 0.53 ms/scan (USB 3.0) |
| Integration Time | 10 µs – 500 ms |
| Detector | 256-pixel InGaAs linear array (50 µm × 500 µm) |
| Optical Platform | Symmetrical Czerny-Turner, 50 mm focal length |
| Resolution (FWHM) | 2–50 nm (configurable via slit and grating) |
| Stray Light | <1% |
| Dynamic Range | 6000:1 (HS mode), 9000:1 (LN mode) |
| SNR | 1900:1 (HS), 5000:1 (LN) |
| Sensitivity | 8.2 × 10⁶ counts/µW·ms (HS, 1000–1750 nm) |
| ADC | 16-bit, 500 kHz |
| Interfaces | USB 3.0 (5 Gbps), Gigabit Ethernet (1 Gbps), HD-26 digital I/O |
| Power | USB-powered (600 mA) or external 12 VDC (320 mA) |
| Dimensions & Weight | 185 × 100 × 184 mm, 2.7 kg |
| Software | AvaSoft v8+ with chemometrics support |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | NIR256-1.7-HSC-EVO |
| Wavelength Range | 900–1750 nm |
| Scan Speed | 0.13 ms/scan |
| Data Sampling Interval | 0.4 ms/scan |
| Measurement Mode | Transmission/Reflection |
| Optical Design | Symmetrical Czerny-Turner, 100 mm focal length, 1-stage TE-cooled |
| Detector | TE-cooled InGaAs linear array (256 × 50 µm × 500 µm) |
| Interface | USB 3.0 (5 Gbps) and Gigabit Ethernet (1 Gbps) |
| AD Converter | 16-bit, 1.2 MHz |
| Integration Time (HS mode) | 20 µs – 500 ms |
| Integration Time (LN mode) | 20 µs – 20 s |
| Dynamic Range (HS/LN) | 4900:1 / 7600:1 |
| SNR (HS/LN) | 1900:1 / 5000:1 |
| Gain Modes | High Sensitivity (HS) and Low Noise (LN) |
| Grating Options | Four selectable, exchangeable gratings |
| Slit Options | Interchangeable slits (25–500 µm) |
| Digital I/O | HD-26 connector with 13 bidirectional digital I/O lines, 2 analog inputs/outputs, trigger/sync/gate/laser control |
| Operating Temperature | 0–40 °C |
| Cooling | ΔT = 24 °C below ambient |
| Dimensions & Weight | 185 × 160 × 184 mm, 3.6 kg |
| Software | AvaSoft suite with chemometrics support |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-NIR512-1.7-EVO |
| Wavelength Range | 900–1750 nm |
| Scan Speed | 0.53 ms/scan |
| Data Sampling Interval | 0.53 ms/scan |
| Detector | 512-pixel InGaAs linear array (25 µm × 500 µm) |
| Optical Platform | Symmetrical Czerny-Turner, 50 mm focal length |
| Resolution (FWHM) | 2–50 nm (configurable via slit and grating) |
| Stray Light | <1% |
| AD Converter | 16-bit, 500 kHz |
| Interface | USB 3.0 (5 Gbps) and Gigabit Ethernet (1 Gbps) |
| Integration Time | 10 µs – 10 s |
| Dynamic Range | up to 9000:1 (LN mode) |
| SNR | up to 5000:1 (LN mode) |
| Trigger & I/O | HD-26 connector with 13 digital I/O lines, 2 analog in/out, TTL trigger, sync, strobe, laser control |
| Power | USB-powered (600 mA) or external 12 VDC (320 mA) |
| Dimensions & Weight | 185 × 100 × 184 mm, 2.7 kg |
| Software | AvaSoft suite with chemometrics support |
| Compliance | CE, RoHS, FDA 21 CFR Part 11-ready (audit trail & user access control enabled) |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-ULS2048CL-EVO |
| Spectral Range | 200–1100 nm |
| Detector | CMOS linear array (2048 pixels) |
| Optical Resolution (FWHM) | 0.06–20 nm (configuration-dependent) |
| Sensitivity | 375,000 counts/µW per ms integration time |
| Signal-to-Noise Ratio | 300:1 |
| Dynamic Range | 4000:1 |
| Stray Light | 0.19–1.0% (grating-dependent) |
| AD Converter | 16-bit, 6 MHz |
| Integration Time | 9 µs – 59 s |
| Interface | USB 3.0 (5 Gbps) / Gigabit Ethernet (1 Gbps) |
| Sampling Speed | 0.38 ms/spectrum (USB3), 1.0 ms/spectrum (Ethernet) |
| I/O | HD-26 connector with 2 analog in/out, 13 digital I/O, trigger/sync/laser control |
| Power | USB 3.0 (500 mA) or 12 VDC (300 mA) |
| Dimensions & Weight | 177 × 127 × 44.5 mm, 1135 g |