Spectroscopy Instruments
Filter
Showing 1321–1350 of 2411 results
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | FS1100 |
| Spectral Range | 300–1100 nm |
| Detector | CCD array |
| Optical Resolution (FWHM) | 1.3 nm |
| Signal-to-Noise Ratio | 450:1 |
| Dynamic Range | 8000:1 |
| Stray Light | <0.05% at 600 nm |
| Display | Monochrome e-ink screen |
| Battery | Removable 4200 mAh Li-ion, >6 h continuous operation |
| Interface | Android-based acquisition app + Windows-compatible spectral processing software |
| Data Export Formats | .txt, .csv, .m |
| Mounting | Adjustable tripod-compatible handle (29–88 cm height range) |
| Integrated features | Motorized shutter, auto-exposure, embedded image/audio annotation |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | FS1100 |
| Spectral Range | 300–1100 nm |
| Detector | CCD |
| Optical Resolution (FWHM) | 1.3 nm |
| Signal-to-Noise Ratio | 450:1 |
| Dynamic Range | 8000:1 |
| Stray Light | <0.05% at 600 nm |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | FS1100 |
| Spectral Range | 300–1100 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 1.3 nm |
| Signal-to-Noise Ratio | 450:1 |
| Dynamic Range | 8000:1 |
| Stray Light | <0.05% at 600 nm |
| Operating System Compatibility | Android & Windows |
| Display | Low-Power Monochrome E-Ink Screen |
| Power Efficiency | Optimized for extended field deployment |
| Brand | Ocean Optics |
|---|---|
| Model | FX UV-VIS / FX VIS-NIR / FX XR |
| Wavelength Range | 200–850 nm / 350–1000 nm / 200–1025 nm |
| Optical Resolution (FWHM) | 1.33 nm (typ.) / 1.69 nm (typ.) / Not Specified |
| Integration Time | 10 µs – 10 s |
| Detector | Back-Illuminated CMOS |
| A/D Resolution | 16 bit |
| Signal-to-Noise Ratio | 290:1 |
| Dynamic Range | 5000:1 |
| Onboard Buffer | 50,000 spectra |
| Max Acquisition Rate | 4,500 spectra/s |
| Grating Options | GRATING_#1 / GRATING_#3 / GRATING_#XR1 |
| Slit Width | 25 µm |
| Connectivity | Gigabit Ethernet, USB 3.0, RS-232, Wi-Fi |
| Onboard Processing | Spectral averaging (up to 5,000 spectra), timestamping, SNR enhancement |
| Brand | Ocean Optics |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | HDX |
| Spectral Range | 200–925 nm |
| Detector | Back-Illuminated CCD |
| Resolution | 0.61–0.72 nm FWHM (with 10 µm slit) |
| Signal-to-Noise Ratio | 400:1 |
| Dynamic Range | 12,000:1 |
| Stray Light | < 0.1% (typical, 3 AU at 600 nm) |
| A/D Conversion | 16-bit |
| Integration Time | 6 ms – 10 s |
| Thermal Stability | ±1 pixel over 0–40 °C |
| F-number | f/4 |
| Onboard Memory | Up to 50,000 spectra |
| I/O | 8 user-programmable digital I/O lines |
| Communication Interfaces | USB 2.0, Gigabit Ethernet, Wi-Fi (802.11 b/g/n), SPI, RS-232 |
| Operating Temperature | 0–40 °C |
| Dimensions | 88.9 × 63.5 × 52.4 mm |
| Weight | 400 g |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | HDX |
| Wavelength Range (HDX-UV-VIS) | 200–800 nm |
| Wavelength Range (HDX-VIS-NIR) | 350–925 nm |
| Wavelength Range (HDX-XR) | 200–1100 nm |
| Optical Resolution (FWHM) | ~0.73 nm (UV-VIS), ~0.7 nm (VIS-NIR), ~1.1 nm (XR) |
| Slit Options (HDX-Raman) | 25 µm, 50 µm |
| Raman Shift Range | 150–3400 cm⁻¹ |
| Optical Resolution (Raman) | 9 cm⁻¹ (25 µm), 12 cm⁻¹ (50 µm) |
| Integration Time | 6 ms – 10 s |
| Dynamic Range | 12,000:1 |
| SNR | 400:1 |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −30–70 °C |
| Dimensions | 88.9 × 63.5 × 52.4 mm³ |
| Weight | 400 g |
| Interface Options | USB 2.0, Gigabit Ethernet, RS-232, AP Wi-Fi |
| Onboard Memory | Up to 50,000 spectra |
| Detector | Back-illuminated CCD |
| Platform | X-Platform electronics |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model Series | HR2, HR4, HR6 |
| Wavelength Range (configurable) | 185–1100 nm |
| Optical Resolution (FWHM) | 0.06–7.24 nm |
| Integration Time | 1 µs–10 s |
| Dynamic Range | 3400:1 to 12000:1 |
| Signal-to-Noise Ratio | 380:1 to 3000:1 |
| Interface | USB Type-C, SMA, 16-pin Samtec TFM, RS-232 |
| Dimensions | 148.8 × 106.4 × 48.2 mm³ |
| Weight | 930.6 g |
| Operating Temperature | 0–55 °C |
| Storage Temperature | −30–70 °C |
| Software | OceanDirect SDK (cross-platform API) |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Model | HR2000+ |
| Spectral Range | 200–1100 nm |
| Detector | Sony ILX511B linear CCD array (2048 pixels) |
| Optical Resolution (FWHM) | 0.035–6.8 nm |
| Sensitivity | 75 photons/count @ 400 nm |
| Signal-to-Noise Ratio | 250:1 (full signal) |
| Dynamic Range | 2 × 10⁸ (system) |
| 1300 | 1 (single acquisition) |
| Stray Light | <0.05% @ 600 nm |
| A/D Resolution | 14-bit |
| Integration Time | 1 ms – 65 s |
| Slit Options | 5, 10, 25, 50, 100, or 200 µm |
| Grating Options | 14 UV–NIR gratings including HC-1 for enhanced UV throughput |
| Optical Design | f/4 symmetrical crossed Czerny-Turner (101.6 mm focal length) |
| Interface | USB 2.0 (480 Mbps), RS-232 (115.2 kbaud), or Ethernet via Remora adapter |
| Trigger Modes | 4 hardware/software-selectable modes |
| Digital I/O | 10 programmable GPIO pins |
| Analog I/O | 1 × 13-bit input, 1 × 9-bit output |
| Dimensions | 148.6 × 104.8 × 45.1 mm |
| Weight | 570 g |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | HR2000+ |
| Wavelength Range | 200–1100 nm |
| Slit Width | 5 µm |
| Optical Resolution (FWHM) | ~0.035–0.12 nm (configurable) |
| Detector | 2048-pixel CCD array |
| A/D Converter | 2 MHz |
| Interface | USB 2.0 or RS-232 |
| Full Spectra Acquisition Rate | Up to 1000 spectra/s |
| Onboard Programmable Microcontroller | Yes |
| Digital I/O | 10 programmable pins |
| Analog Input/Output | 1 each |
| Trigger Support | External TTL, analog, or software |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | Ocean Optics HR4 |
| Spectral Range | 220–1050 nm (configurable) |
| Optical Resolution | 0.13–1.16 nm FWHM (configurable) |
| Signal-to-Noise Ratio | 3000:1 (high-speed averaging mode) |
| Dynamic Range | 1300:1 (single-scan) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | HR4 Pro |
| Spectral Range | 190 nm – 1100 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 0.42 nm (typical), 0.72 nm (typical) |
| Sensitivity | 6 counts/photon |
| Signal-to-Noise Ratio | 250:1, 290:1, and 300:1 (full signal, configuration-dependent) |
| Dynamic Range | 1500:1, 2000:1, and 2500:1 (integration-time dependent) |
| Stray Light | <0.05% at 600 nm |
| Configuration Options | UV-Vis (200–875 nm), Vis-NIR (350–1025 nm), Full Range (200–1100 nm) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | HR4000 |
| Optical Configuration | Single-beam |
| Detector | 3648-pixel linear CCD array |
| Wavelength Range | 200–1100 nm |
| Optical Resolution | ~1.0 nm FWHM |
| Slit Width | 25 µm |
| Grating | HC-1 holographic concave grating, 300 lines/mm |
| Stray Light | <0.05% at 600 nm |
| Focal Length | f/4, 101 mm |
| Dynamic Range | 2 × 10⁸ (system) |
| 2000 | 1 (single acquisition) |
| Data Transfer | 4 ms (USB 2.0 full spectrum) |
| Input/Output | 10 programmable GPIOs |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | HR4000CG-UV-NIR |
| Optical Architecture | Single-beam |
| Detector Type | Toshiba TCD1304AP CCD |
| Wavelength Range | 190–1100 nm |
| Grating | HC-1, 300 lines/mm |
| Slit Width | 5 µm |
| Optical Resolution (FWHM) | 0.75 nm |
| Stray Light | <0.05% at 600 nm |
| Integration Time | 4 ms–20 s (continuous) |
| Signal-to-Noise Ratio | 300:1 (full signal) |
| Dynamic Range (system) | 2×10⁹ |
| Interface | USB 2.0 (480 Mbps), RS-232 (2-wire), I²C |
| Operating Temperature | –10°C to +50°C |
| Storage Temperature | –30°C to +70°C |
| Humidity | 0–90% RH (non-condensing) |
| Dimensions | 148.6 × 104.8 × 45.1 mm |
| Weight | 0.57 kg |
| Fiber Connector | SMA 905 |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | HR4Pro |
| Spectral Range | 190 nm – 1100 nm |
| Detector | Linear Silicon CCD Array |
| Optical Resolution (FWHM) | 0.42 nm (typical), 0.72 nm (typical) |
| Sensitivity | 6 counts (RMS dark noise) |
| Signal-to-Noise Ratio | 250:1 (full signal), 290:1 (full signal), 300:1 (full signal) |
| Dynamic Range | 2000:1, 2500:1, 1500:1 (single acquisition) |
| Stray Light | <0.05% at 600 nm |
| Slit Options | 5 µm, 10 µm |
| Grating Options | H13, H38, H48, HC1 |
| A/D Resolution | 14-bit |
| Integration Time | 3.8 ms – 10 s |
| Thermal Drift | 0.03–0.06 pixels/°C |
| Dimensions | 148.6 mm × 104.8 mm × 45.1 mm |
| Weight | 570 g |
| Interface | USB 2.0 (480 Mbps), RS-232, I²C |
| Fiber Connector | SMA 905 |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | HR4Pro |
| Spectral Range | 190 nm – 1100 nm |
| Detector | Linear Silicon CCD Array |
| Optical Resolution (FWHM) | 0.42 nm (typ.), 0.72 nm (typ.), 0.47 nm (typ.), 0.62 nm (typ.), ~0.66 nm (typ.), ~0.9 nm (typ.) |
| Sensitivity | 6 counts per photon (RMS dark noise) |
| Signal-to-Noise Ratio | 250:1 (full signal), 290:1 (full signal), 300:1 (full signal) |
| Dynamic Range | 2000:1 (single acquisition), 2500:1 (single acquisition), 1500:1 (single acquisition) |
| Stray Light | <0.05% at 600 nm, <0.10% at 435 nm |
| Integration Time | 3.8 ms – 10 s |
| Linearity | ±0.5% nonlinearity |
| Thermal Drift | 0.03–0.06 pixels/°C |
| Dimensions | 148.6 mm × 104.8 mm × 45.1 mm |
| Weight | 570 g |
| Interface | USB 2.0 (480 Mbps), RS-232 (2-wire), I²C |
| Slit Options | 5 µm, 10 µm |
| Grating Options | H13, H38, H48, HC1 |
| A/D Resolution | 14-bit |
| Fiber Coupling | SMA 905 |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | HR4Pro |
| Spectral Range | 190 nm – 1100 nm |
| Detector | Linear Silicon CCD Array |
| Optical Resolution (FWHM) | 0.47 nm (typical) to 0.66 nm (typical), configurable down to <0.1 nm with optimized grating/slit combinations |
| Sensitivity | 6 counts RMS dark noise |
| Signal-to-Noise Ratio | 250:1 to 300:1 (full signal) |
| Dynamic Range | 2 × 10⁹ (system) |
| 1300 | 1 to 2000:1 (single acquisition) |
| Stray Light | <0.05% at 600 nm |
| Thermal Stability | 0.03–0.06 pixels/°C |
| Slit Options | 5 µm, 10 µm |
| Grating Options | H13, H38, H48, HC1 |
| A/D Resolution | 14-bit |
| Integration Time | 3.8 ms – 10 s |
| Interface | USB 2.0 (480 Mbps), RS-232 (2-wire), I²C |
| Dimensions | 148.6 × 104.8 × 45.1 mm |
| Weight | 0.57 kg |
| Fiber Coupling | SMA 905 |
| Linearity | ±0.5% NL |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | Ocean Optics HR6 |
| Spectral Range | ~185–1100 nm |
| Optical Resolution (FWHM) | <1.0 nm (with 25 µm slit, configuration-dependent) |
| Signal-to-Noise Ratio | 3500:1 (on-board averaging mode) |
| Dynamic Range | 12,000:1 (single scan) |
| Integration Time | 7.2 ms – 5 s |
| Thermal Stability | 0.02 nm/°C |
| Pixel Count | 2048 |
| Interface | USB Type-C, SMA 905, 16-pin Samtec TM, RS-232 |
| Operating Temperature | 0–55 °C |
| Storage Temperature | −30–70 °C |
| Dimensions | 149 × 106 × 48 mm |
| Weight | 931 g |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | HRS-5A |
| Type | Handheld Raman Spectrometer |
| Spectral Range | 200–3200 cm⁻¹ |
| Spectral Resolution | 15 cm⁻¹ (typical) |
| Excitation Wavelength | 785 ± 0.5 nm (linewidth < 0.1 nm) |
| Laser Power | 0–500 mW (continuously adjustable) |
| Spectral Repeatability | ±0.5 nm |
| Dimensions (L×W×H) | 180 × 85 × 30 mm (excl. probe extension) |
| Weight | 550 g |
| Operating Temperature | −10 to 50 °C |
| Storage Temperature | −20 to 60 °C |
| Relative Humidity | ≤90% (non-condensing) |
| Battery Life | ≥3.5 h (standard), ≥12 h (optional extended-life battery) |
| Local Storage Capacity | >1,000,000 spectra |
| Display | 1920 × 1080 capacitive touchscreen |
| Onboard Camera | 13 MP |
| Positioning | GPS/BeiDou/GLONASS + Wi-Fi/4G triangulation |
| Connectivity | Wi-Fi, 4G (SIM-card enabled), Micro-USB |
| Operating System | Android-based embedded platform |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | JAZ |
| Spectral Range | Configurable via interchangeable gratings (standard options: 200–1025 nm) |
| Detector Type | CMOS linear array (custom-optimized) |
| Optical Resolution | ~0.3–10.0 nm FWHM (grating- and slit-dependent) |
| Sensitivity | 75 photons/count @ 400 nm |
| Signal-to-Noise Ratio | 250:1 (full signal, 1 s integration) |
| Dynamic Range | 8.5 × 10⁷ (system) |
| 1300 | 1 (single acquisition) |
| Stray Light | < 0.05% @ 600 nm |
| Power Consumption | ~2.5 W |
| Compliance | RoHS-compliant |
| Communication | 100 Mbps Ethernet (TCP/IP), USB 2.0, SD card interface |
| Onboard Processing | ARM-based microprocessor with real-time data logging and post-processing capability |
| Modular Architecture | Supports up to 8 stacked instrument modules (spectrometer, OLED display, Ethernet/SD, battery, LED source, etc.) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop |
| Integration | Modular |
| Laser Wavelength | 1064 nm (Nd:YAG, optional 532 nm) |
| Laser Pulse Energy | 50–200 mJ |
| Spectral Range | 180–1037 nm |
| Channels | 1–8 configurable |
| Optical Resolution | 0.1 nm (FWHM) |
| Detector | Linear or Area CCD |
| Trigger Delay Accuracy | ±450 ns |
| Trigger Jitter | ±10 ns |
| Spot Size | ≤50 µm |
| Sample Max Dimensions | 30 × 30 × 20 mm |
| Sample Max Mass | 2 kg |
| XYZ Translation Stage Range | 60 × 60 × 60 mm |
| Plasma Emission Detection Sensitivity | ≥10 ppm (element-dependent) |
| Fiber Optic Coupling | UV-Enhanced Silica Fiber |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Maya 2000 |
| Spectral Range | 200–1100 nm |
| Detector Type | Back-illuminated 2D FFT-CCD (Hamamatsu S9840) |
| Quantum Efficiency | up to 90% @ 250 nm |
| Signal-to-Noise Ratio | 450:1 (full well, with 5 s integration) |
| Dynamic Range | 15,000:1 (typical, A/D-limited) |
| Stray Light | <0.05% @ 600 nm |
| Optical Resolution (FWHM) | ~0.035 nm (configurable via grating and slit selection) |
| Integration Time | 5 ms – 20 s |
| A/D Conversion | 16-bit, 500 kHz sampling |
| Pixel Array | 2048 × 14 active pixels (14 µm × 14 µm) |
| Readout Speed | Optimized for high-throughput acquisition |
| Slit Options | 5, 10, 25, 50, 100, 200 µm |
| Grating Options | 14 standard gratings, including HC-1 broadband grating (175–1100 nm) |
| Onboard Features | 10 user-programmable GPIOs, programmable trigger modes (single/continuous), integrated order-sorting filters, focusing lens assembly for enhanced throughput |
| Brand | Ocean Optics |
|---|---|
| Model | Maya 2000 |
| Spectral Range | 200–1100 nm |
| Detector Type | Back-illuminated FFT-CCD (Hamamatsu S9840) |
| Quantum Efficiency | Up to 90% @ 250 nm |
| Signal-to-Noise Ratio | 450:1 (full well, 1 s integration) |
| Dynamic Range | 15,000:1 (typical, with 16-bit A/D) |
| Stray Light | <0.05% @ 600 nm |
| Optical Resolution (FWHM) | ~0.035 nm (dependent on grating and slit selection) |
| Integration Time | 5 ms – 20 s |
| A/D Conversion | 16-bit, 500 kHz |
| Pixel Array | 2048 × 14 active pixels |
| Pixel Size | 14 µm × 14 µm |
| Slit Options | 5, 10, 25, 50, 100, 200 µm |
| Grating Options | 14 standard gratings, including HC-1 broadband grating (175–1100 nm) |
| Onboard GPIOs | 10 user-programmable digital I/O lines |
| Interface | USB 2.0 |
| Software | SpectraSuite (Windows/macOS/Linux) |
| Brand | Ocean Optics |
|---|---|
| Model | Maya2000 Pro |
| Spectral Range | 200–1100 nm |
| Detector Type | Back-Illuminated CCD |
| Optical Resolution | 0.07–6.7 nm (slit- and grating-dependent) |
| Signal-to-Noise Ratio | 450:1 |
| Dynamic Range | ~8000:1 |
| Stray Light | <0.05% at 600 nm, <0.10% at 435 nm |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | MAYA2000PRO |
| Detector | Hamamatsu S10420 back-illuminated CCD (2048 × 64 pixels) |
| Spectral Range | 153–1100 nm |
| Wavelength Resolution | 0.035–8.4 nm (dependent on grating and slit selection) |
| Slit Options | 5, 10, 25, 50, 100, 200 µm |
| Integration Time | 17 ms – 10 s |
| Signal-to-Noise Ratio | 450:1 |
| Dimensions | 148.6 × 104.8 × 45.1 mm |
| Weight | 570 g |
| Interface | USB 2.0 (bus-powered) |
| Onboard Programmable Microcontroller | Yes |
| Calibration | User-performable wavelength calibration |
| Brand | Ocean Optics |
|---|---|
| Model | Maya2000Pro |
| Detector Options | Hamamatsu S10420 (UV-Vis), S11510 (Vis-NIR) |
| Spectral Range | 165–1100 nm (S10420), 400–1180 nm (S11510), or 780–1180 nm (Maya2000Pro-NIR preset) |
| Optical Resolution (FWHM) | Configurable via grating and slit selection |
| Peak Quantum Efficiency | 75% @ 600 nm (S10420), 85% @ 700 nm (S11510) |
| SNR (full signal) | ~450:1 |
| Dynamic Range | 15,000:1 (typical) |
| Integration Time | 7.2 ms – 5 s |
| Interface | USB 2.0 & RS-232 |
| Operating Temperature | 0–50 °C |
| Dimensions | 182 × 110 × 47 mm |
| Weight | 1.18 kg |
| Fiber Connector | SMA 905 (NA 0.22) |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MicroTEQ-S1 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 400–1100 nm |
| Spectral Resolution | ~10 cm⁻¹ @ 5 µm slit |
| Spatial Resolution | 0.14–7.7 nm (dependent on objective magnification and laser wavelength) |
| Minimum Wavenumber Shift | 200 cm⁻¹ |
| Spectral Reproducibility | Not specified |
| Brand | Ocean Optics |
|---|---|
| Model | MicroTEQ-S1 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 400–1100 nm |
| Spectral Resolution | ~10 cm⁻¹ @ 5 µm slit |
| Spatial Resolution | 0.14–7.7 nm (dependent on objective magnification and laser wavelength) |
| Minimum Wavenumber Shift | 200 cm⁻¹ |
| Detector | Back-Illuminated, Deep-Depletion CCD |
| A/D Resolution | 18-bit |
| Dynamic Range | 85,000:1 |
| SNR | 1000:1 |
| Integration Time | 8 ms – 60 min |
| Laser Options | 405 nm, 450 nm, 532 nm, 633 nm, 785 nm (power-adjustable, up to 500 mW) |
| Microscope Objectives | 5×, 10×, 20×, 50×, optional 100× (NA 0.15–0.8) |
| Imaging Sensor | 1/2″ CMOS, 2048 × 1536 pixels |
| Motorized XY Stage (optional) | 50 mm × 50 mm travel, 1 µm resolution, 2 µm repeatability |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible workflow support |
| Brand | Ocean Optics |
|---|---|
| Model | MX Pro |
| Instrument Type | Benchtop |
| Integration | Fully Integrated Multi-Channel Spectrometer |
| Spectral Range | 180–1100 nm |
| Max Channels | 8 |
| Optical Resolution (FWHM) | 0.1 nm (configurable) |
| SNR (single-scan) | 380:1 |
| A/D Resolution | 16-bit |
| Detector Options | Linear CCD or Area CCD |
| Scan Rate | 500 Hz |
| Integration Time | 1 µs – 2 s |
| Trigger Delay Range | –450 ns to +450 ns |
| Trigger Jitter | 20–30 ns |
| Timing Step Resolution | 13.8 ns |
| Trigger Interface | TTL-compatible, <5.5 V |
| Data Interface | USB 3.0 |
| Power Supply | 5 V DC, 5 A |
| Operating Systems | Windows 7/8/10/11 (32-/64-bit) |
| Dimensions (8-ch) | 585 × 165 × 210 mm |
| Weight (8-ch) | 12 kg |
| Dimensions (4-ch) | 345 × 165 × 210 mm |
| Weight (4-ch) | 6.5 kg |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Origin | Domestic (China) |
| Model | NIRQuest |
| Instrument Type | Laboratory |
| Application Field | Grain Analysis |
| Operating Principle | Portable & Online Deployment |
| Wavelength Range | 900–1700 nm (extendable to 2500 nm) |
| Scan Speed | 1 ms |
| Measurement Mode | Diffuse Reflectance / Transmission |
| Detector | InGaAs Linear Array with Integrated Thermoelectric Cooling |
| Optical Platform | Crossed Czerny-Turner |
| A/D Resolution | 16-bit USB |
| Interface | SMA905 Fiber Optic Connector |
| Compliance | Compatible with ASTM E1655, ISO 12099, USP <856>, and GLP/GMP-aligned data workflows |
| Brand | Ocean Optics |
|---|---|
| Model | NIRQuest |
| Type | Laboratory Benchtop / Portable Fiber-Optic NIR Spectrometer |
| Wavelength Range | 900–1700 nm (standard), up to 2500 nm (optional configurations) |
| Detector | Hamamatsu InGaAs linear array (512 or 256 pixels) |
| Cooling | Thermoelectric (TEC), stabilized to ~30 °C below ambient |
| Optical Platform | Crossed Czerny-Turner |
| A/D Resolution | 16-bit USB interface |
| Integration Time | As low as 1 ms |
| Sampling Modes | Diffuse reflectance, transmission |
| Grating Options | Multiple groove densities for resolution/sensitivity trade-offs |
| Slit Options | 10, 25, 50, 100, or 200 µm width or fiber-coupled (no slit) |
| Interface | SMA 905 fiber port |
| Software Compatibility | SpectraSuite (with spectral acquisition, basic preprocessing, and export functions) |
| Compliance | Designed for GLP-aligned workflows |