Temperature & Humidity Detector
Filter
Showing 331–351 of 351 results
| Brand | VNIIOFI |
|---|---|
| Origin | Russia |
| Model | BB80/350 |
| Aperture Diameter | 350 mm |
| Temperature Range | 220–350 K |
| Additional Setpoint | 313 K |
| Spectral Range | 2.5–15 µm |
| Emissivity | 0.96 ± 0.02 |
| Uncertainty (280–300 K) | ±0.1 K |
| Repeatability (300 K) | 0.5 K |
| 10-Minute Stability | 5 K |
| Continuous Operation Time | 8 h |
| Operating Environment | Indoor, Dry Nitrogen Atmosphere, Standard Pressure |
| Ambient Temperature | 0–30 °C |
| Vacuum Chamber Pressure | 10⁻⁵–10⁻⁸ Torr |
| Cryogenic Base Temperature | 77 K |
| Brand | VNIIOFI |
|---|---|
| Origin | Russia |
| Product Type | Eutectic Fixed-Point Cell (for High-Temperature Blackbody Radiance Calibration) |
| Compatible Radiation Sources | BB3500, BB3500MP, BB3200pg, BB3500-M, BB3200pg (Re-C) |
| Eutectic Temperatures | 2474 °C to 3185 °C |
| Crucible Material | Graphite |
| Cavity Material Options | HfC–C, ZrC–C, TiC–C, δ(MoC)–C, Re–C |
| Effective Emissivity | 0.999 to 0.99994 |
| Cavity Dimensions (L×W×D) | 54×24×34 mm to 124×164×43×4 mm (varies by model and source) |
| Brand | VNIIOFI |
|---|---|
| Origin | Russia |
| Model | LABB |
| Temperature Range | −60 °C to +180 °C |
| Temperature Stability | ±0.02 °C (maintained by liquid thermostat) |
| Aperture Diameter | 500 mm |
| Effective Emissivity @ −60 °C | ≥0.99 |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | 61161-283 |
| Price | Upon Request |
| Accuracy | ±1°C (Model 61161-283) |
| Temperature Range | –50 to 300°C (–58 to 572°F) |
| Resolution | 0.1°C from –19.9 to 199.9°C, 1°C elsewhere |
| Probe Diameter × Length | 0.36 cm × 12.7 cm (0.14" × 5") |
| Unit Dimensions | 4.4 cm Ø × 1.3 cm D (1.73" Ø × 0.51" D) |
| Weight | 42.5 g (1.5 oz.) |
| Display | 6.4 mm high LCD digits |
| Update Interval | 1 second |
| Housing | Waterproof and shockproof |
| Probe Material | Stainless steel sensor |
| Calibration | ISO/IEC 17025-accredited certificate traceable to NIST standards |
| Power | 1.5 V silver-oxide battery (1 year continuous operation) |
| Accessories | 3 m probe cable, magnet mount, suction cups, Velcro® fastener |
| Brand | Traceable |
|---|---|
| Origin | USA |
| Model | VWRI620-2006 |
| Dimensions | 83 × 38 × 178 mm |
| Weight | 227 g |
| Temperature Range | –200 to +1370 °C |
| Resolution | 0.1 °C (–50 to 740 °C), 1.0 °C (elsewhere) |
| Accuracy | ±1 °C (–50 to 740 °C), ±2 °C (elsewhere) |
| Probe Type | Integrated K-type bead thermocouple (1200 × 1.5 mm) |
| Display Update Rate | 2 Hz |
| Alarm Increment | 1.0 °C |
| Timer Range | 1 min to 23 h 59 min |
| IP Rating | IP65 (dust-tight and water-resistant) |
| Certifications | NIST-traceable calibration certificate included |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | PR5500 / PR5600 |
| Temperature Range | −200.0 to +850.0 °C |
| Accuracy | Class 0.02 (per IEC 60751 for Pt100, ASTM E230 for thermocouples) |
| Resolution | 0.001 °C |
| Display | 6-digit LCD |
| Operating Environment | 18–28 °C (23 ± 5 °C recommended) |
| Power Supply | 3 × AA alkaline batteries (1.5 V each) |
| Dimensions | 155 × 70 × 30 mm |
| Weight | 0.25 kg |
| Input Types | Pt100, Pt1000, K, S, E, T, J, R, B, N thermocouples |
| Cold Junction Compensation | Internal, External, or Manual |
| Unit Selection | °C, °F, K |
| Statistical Functions | REL, MAX, MIN, AVG, PEAK-TO-PEAK, STD DEV, SAMPLE COUNT |
| Standard Sensors | 1× K-type probe (170 mm × Ø4 mm, 1.5 m SMP connector), 1× Pt100 probe (250 mm × Ø4 mm, 1.5 m USB connector) |
| Compliance | CE, RoHS, ISO/IEC 17025 traceable calibration support |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | TFX410 / TFX410-1 / TFX420 / TFX422 / TFX430 |
| Temperature Range | –100 °C to +500 °C |
| Resolution | ±0.05 °C (–50 °C to +199.99 °C), ±0.2 °C (other ranges) |
| Accuracy | ±0.1 °C |
| Weight | 90 g |
| IP Rating | IP67 |
| Sensor Type | Pt100 or Pt1000 |
| Battery | 3.0 V CR2477 lithium, user-replaceable, 1 Ah, ~5-year life |
| Dimensions (L×W×H) | 109 × 54 × 22 mm (TFX430) |
| Certifications | DAkkS-accredited calibration (TFX430), factory 3-point calibration (others), GFA-compliant, compliant with DIN EN ISO/IEC 17025 requirements for accredited calibration labs |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WQ101 |
| Pricing | Available Upon Request |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | T1000S |
| Temperature Measurement Principle | Resistance-based (RTD/SPRT compatible) |
| Measurement Method | Contact |
| Temperature Range | −200 °C to +850 °C |
| Resolution | 0.001 °C |
| Accuracy | ±0.01 °C (full scale) |
| Long-term Stability | <5 mK/year |
| Channels | 10 simultaneous |
| Sampling Interval | 1 s per channel |
| Units | °C / °F / K / Ω |
| Built-in Standard | ITS-90 |
| Display | 7-inch capacitive touchscreen |
| Interface | USB |
| Probe Connector | 5-pin straight plug |
| Power Supply | 110/220 VAC, 50/60 Hz |
| Dimensions (L×W×H) | 365 × 260 × 160 mm |
| Operating Environment | 0–40 °C, ≤65% RH |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | T6000 |
| Temperature Range | -200 °C to +250 °C |
| Accuracy | ±0.02 °C |
| Probe Diameter Options | Φ4 mm, Φ5 mm, Φ6 mm |
| Probe Length Options | 50–400 mm |
| Construction | Hermetically Sealed, Waterproof (IP67 Rated), Stainless Steel Sheath |
| Sensor Element | Pt100 or Pt1000 (IEC 60751 Class A or AA) |
| Output | 2-wire / 3-wire / 4-wire configurable |
| Stability | ≤0.01 °C/year typical drift |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | T6000 |
| Temperature Measurement Principle | Resistance-based (RTD) |
| Measurement Method | Contact |
| Temperature Range | −200 to +1600 °C |
| Resolution | 0.001 °C |
| Accuracy | ±0.01 °C (for RTDs), ±0.3% FS (for thermistors), ±0.2% FS (for thermocouples) |
| Long-term Stability | <0.005 °C/year |
| Display | 7-inch capacitive touchscreen |
| Channel Configuration | Dual-channel, expandable |
| Sensor Compatibility | ITS-90-compliant platinum resistance thermometers (Pt100, Pt1000), NTC/PTC thermistors, and standard thermocouples (J, K, T, E, R, S, B, N) |
| Calibration Standard | Built-in ITS-90 reference implementation |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T6WZP05 Series |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | YWSD50/100(A) |
| Temperature Range | −30 °C to 100 °C |
| Relative Humidity Range | 0–100 %RH |
| Temperature Accuracy | ±0.5 °C (−30 to 0 °C), ±1.0 °C (0 to 100 °C) |
| RH Accuracy | ±2.0 %RH (10–90 %RH), ±3.0 %RH (<10 %RH or >90 %RH) |
| Dew Point Accuracy | ±0.5 °C |
| Wet-Bulb Accuracy | ±0.5 °C |
| Resolution | 0.01 °C / 0.01 %RH |
| Response Time (RH) | ≤10 s (at 90 %RH, 25 °C, still air) |
| Sampling Rate | 400 ms |
| Display | 4½-digit backlit dual LCD |
| Power Supply | 9 V alkaline battery (current draw ≤20 mA) |
| Operating Ambient Temperature | −20 °C to +50 °C |
| Enclosure Rating | IP54 |
| Explosion Protection Mark | Exib I Mb |
| Certified Standards | MA Safety Certification for Coal Mines, CNEX Explosion-Proof Certificate, Third-Party Verification Report |
| Dimensions | 225 × 45 × 34 mm |
| Weight | 200 g |
| Brand | Other Brands |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | General Distributor |
| Product Category | Domestic |
| Model | YK2000 |
| Pricing | Upon Request |
| Instrument Type | Temperature Verification and Calibration System |
| Brand | Other Brands |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | General Distributor |
| Product Category | Domestic |
| Model | YK2000-C |
| Instrument Type | Temperature Verification and Calibration System |
| Calibration Range | −45 °C to 1200 °C |
| Supported Sensors | PT100, Cu50, Types B, C, D, E, J, K, N, R, T thermocouples |
| Switching Units | ISOTECH 954 & 958 low-thermal-EMF scanners |
| Reference Instrument | ISOTECH Dry-Block Calibrator + TTI-7 Precision Thermometer |
| Software Interface | RS232 with handshake protocol |
| Automation Level | Fully automated, unattended operation |
| Data Output | Standardized calibration reports, audit-ready records, database-backed traceability |
| Brand | YORK |
|---|---|
| Origin | United Kingdom |
| Model | ETBB |
| Instrument Category | Temperature Verification and Calibration System |
| Blackbody Cavity Diameter | 10 mm |
| Effective Emissivity | ≥0.999 |
| Spectral Band | (8–14) µm |
| Expanded Uncertainty (k=2) for Brightness Temperature Reproduction | ≤0.07 °C |
| Compatible Standard Bath | 796MA |
| Reference Sensor | YKS500 Platinum Resistance Thermometer |
| Readout | milliK Precision Thermometry System |
| Traceability | NPL-traceable via periodic calibration of reference standards |
| Brand | YORK |
|---|---|
| Origin | United Kingdom |
| Model | FTBB |
| Type | Portable |
| Cavity Aperture | 30 mm |
| Effective Emissivity | ≥0.999 |
| Spectral Range | (8–14) µm |
| Brightness Temperature Uncertainty | ≤0.07 °C (k=2) |
| Compliance | JJG856-2015, JJF1552-2015, JJF1187-2008, JJF1107-2003 |
| Brand | York Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | DM9600P |
| Measurement Principle | Chilled-mirror hygrometry |
| Display | 7-inch capacitive touchscreen LCD with bilingual (EN/CN) UI |
| Control System | Digital fuzzy logic control with auto-balance dew point stabilization algorithm |
| Communication Interfaces | RS-485, USB 2.0 |
| Data Storage | SD card slot (up to 32 GB, FAT32 formatted) |
| Compliance | Designed per ISO 8503-1 (surface profile), ASTM E104 (controlled humidity environments), and aligned with calibration traceability requirements of ISO/IEC 17025 |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | YWSD70/100 |
| Price Range | USD 0.15–720 |
| Instrument Type | Specialized Environmental Monitoring Device for Hazardous Locations |
| Temperature Range | −30 °C to +70 °C |
| Temperature Accuracy | ±1.0 °C (−30 °C to 0 °C) |
| Relative Humidity Range | 0–100 %RH |
| RH Accuracy | ±2.5 %RH (10–90 %RH) |
| Resolution | 0.01 °C / 0.01 %RH |
| Operating Ambient Temperature | −20 °C to +50 °C |
| Display | Backlit 4½-digit dual-parameter LCD |
| Power Supply | 9 V alkaline battery (typical operating current ≤20 mA |
| Dimensions | 225 × 45 × 34 mm |
| Weight | 200 g |
| Ingress Protection | IP54 |
| Explosion Protection Mark | Exib I Mb |
| Data Logging Endurance | ≥10,000 write/erase cycles |
| Humidity Response Time | ≤10 s (at 90 %RH, 25 °C, still air) |
| Sampling Interval | <500 ms |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | YWSD |
| Price Range | USD 0.15–750 |
| Channel Count | Single-Channel |
| Temperature Range | −30 °C to +70 °C |
| Humidity Range | 0 %–100 % RH |
| Dew Point Range | −30 °C to +100 °C |
| Temp. Resolution | 0.1 °C |
| RH Resolution | 0.1 % |
| Temp. Accuracy | ±0.5 °C (−30–0 °C), ±2 °C (0–70 °C) |
| RH Accuracy | ±2.5 % RH (10–90 % RH), ±3.5 % RH (<10 % or >90 % RH) |
| Dew Point Accuracy | ±1 °C |
| Response Time (RH) | 10 s (at 90 % RH, 25 °C, still air) |
| Sampling Interval | 2 s – 24 h |
| Memory Capacity | 32,700 data points |
| Display | Backlit LCD |
| Alarm Function | Configurable temp/RH thresholds |
| LED Indicators | Red/Yellow (status/fault), Green (operational) |
| Data Interface | USB 2.0 |
| Software Platform | Windows 2000/XP/Vista/7 |
| Explosion Protection | Exib I Mb (coal mine), Exib IIC T5 Gb (industrial gas), Exib D 21 T100 (dust) |
| Ingress Protection | IP65 |
| Battery Life | Up to 12 months (typical logging interval ≥1 min) |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYKX-20 |
| Price Range | USD 1,400–7,000 (FOB) |
| Instrument Type | Online Continuous Monitoring System |
| Measurement Resolution | 0.1 °C |
| Accuracy | ≤ ±0.3 °C |
| Temperature Range | 33 °C to 43 °C (configurable alarm threshold) |
| Measurement Site | Forehead or wrist |
| Response Time | ≤ 1 s |
| Operating Ambient Temperature | 10 °C to 40 °C |
| Relative Humidity Limit | ≤ 85 % RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| External Frame Dimensions (H×W×D) | 2200 mm × 830 mm × 300 mm |
| Passage Opening (H×W×D) | 1920 mm × 700 mm × 300 mm |
| Installation Method | Tool-free quick-connect modular assembly |