| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TMA 402 F1 Hyperion |
| Temperature Range | −150 °C to 1550 °C (with interchangeable furnaces) |
| Temperature Accuracy | ±0.1 °C |
| Force Range | ±3 N |
| Displacement Range | ±2.5 mm |
| Displacement Resolution | 1.25 nm |
| Force Resolution | 0.01 mN |
| Heating Rate | 0–50 °C/min |
| Vacuum Level | 10⁻⁴ mbar |
| Measurement Atmospheres | Oxidizing, Reducing, Inert, Vacuum |
| Dual-Furnace Capability | Yes |
| Compatible with DSC/STA Furnaces | Yes |
| Dynamic Force Mode | Optional |
| Rate-Controlled Sintering (RCS) | Optional |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TMA 402 F3 Hyperion |
| Temperature Range | -150°C to 1550°C |
| Temperature Accuracy | ±0.1°C |
| Force Range | ±3 N |
| Displacement Range | ±2.5 mm |
| Displacement Resolution | 0.125 nm |
| Force Resolution | 0.01 mN |
| Heating Rate | 0–50°C/min |
| Measurement Atmosphere | Oxidizing, Reducing, Inert, Vacuum (down to 10⁻⁴ mbar) |
| Dual-Furnace Capability | Yes |
| Compatible Furnaces | Interchangeable with DSC and STA systems |
| Optional Modes | Dynamic Force, Rate-Controlled Sintering (RCS), Compression/Indentation/Bending/Tension |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VTMR-niumag |
| Pricing | Available Upon Request |
| Magnet Type | Permanent Magnet |
| Magnetic Field Strength | 0.5 ± 0.05 T |
| Standard Temperature Range | Room Temperature to 130 °C |
| Optional Cryo/High-Temp Module | −100 °C to 200 °C |
| Imaging Capability | Optional |
| Measurement Modes | T₁ & T₂ Relaxometry, NMR Imaging (MRI), Quantitative Analysis |
| Typical Acquisition Time | ≤2 min per sample |
| Sample Forms | Solutions, Gels, Solids, Powders, Particulates |
| Core Technology | FLAT (Fast Low-Amplitude Transient) Pulse Sequence for Short-T₂/Weak-Signal Detection |
| Brand | Stanford |
|---|---|
| Origin | USA |
| Model | MPA100 |
| Temperature Range | +10 °C to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.3 °C (@ ~100 °C), ±0.5 °C (@ ~250 °C), ±0.8 °C (@ ~400 °C) |
| Capillary Outer Diameter | 1.4–2.0 mm |
| Temperature Resolution | 0.1 °C |
| Power Supply | AC 90–264 V |
| Weight | 4.1 kg |
| Operating Ambient | 0–40 °C |
| Interface | USB, RS-232 |
| Software | MeltView (Windows-compatible) |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | DIL2010C |
| Temperature Range | –170 °C to 500 °C (or RT to 1000 °C with standard configuration) |
| Max Sample Size | 50 mm length × 10 mm diameter |
| Furnace Type | Split-tube (clamshell) quartz tube furnace |
| Sample Holder & Pushrod | Fused silica |
| Thermocouple | Type N (sample & control) |
| Heating Rate | 1–30 °C/min |
| LVDT Linear Range | ±2.54 mm |
| LVDT Resolution | 0.02 µm |
| Contact Force | Adjustable |
| Cryogenic Assembly | Stainless-steel cold stage with vertical transfer tube, Dewar reservoir mounted above furnace |
| Ambient Protection | Acrylic enclosure with dry inert gas purge |
| Compliance | ASTM E228, ISO 11359-1/-2, USP <631>, GLP-ready data logging |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 6200 |
| Measurement Mode | Isoperibol |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.0001 °C |
| Precision | ±0.1% RSD |
| Single-Sample Test Time | 6–7 min |
| Heat Capacity | 33,000 J |
| Outer Water Jacket Volume | 2 L |
| Inner Water Bucket Volume | 342 mL |
| Oxygen Bomb Pressure Rating | 200 atm |
| Bomb Volume | 342 mL |
| Data Storage Capacity | 1000 tests |
| Interface Options | RS-232, USB, Ethernet, Balance Integration, Printer Port |
| Operating System | Linux-based embedded controller |
| Calibration & Reporting | Automatic correction for fuse wire, nitric acid formation, sulfur oxidation, and hydrogen combustion enthalpy |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 6400 |
| Temperature Range | 0–40 °C |
| Temperature Resolution | 0.0001 °C |
| Precision | ±0.1% RSD |
| Single-Sample Test Time | 6–7 min |
| Heat Capacity | 33,000 J/K |
| Outer Water Jacket Volume | 2 L |
| Inner Water Bucket Volume | 342 mL |
| Oxygen Filling | Fully Automated |
| Jacket Water Filling | Fully Automated |
| Pressure Release | Automated |
| Bomb Rinsing | Automated |
| Data Storage Capacity | 1,000 tests |
| Connectivity | Ethernet |
| Display | Touchscreen LCD |
| Measurement Principle | Isoperibol (Constant-Temperature Jacket) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Model | DMA 8000 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –196 °C to 600 °C (with LN₂ cryogenic cooling) |
| Frequency Range | 0.01–300 Hz |
| Cooling Rate | ≤15 min from ambient to –190 °C |
| Liquid Nitrogen Consumption | ~1 L per typical low-temperature DMA run |
| Sample Modes | Dual/Triple Cantilever, 3-Point Bending, Tension, Compression, Shear, and TMA Mode |
| Humidity Control Range | 10–90 % RH (optional humidity generator) |
| Optical Access | Quartz furnace viewport for in-situ visual monitoring and UV-curable sample testing |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DSC 4000 / DSC 6000 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –100 °C to 600 °C (with optional cryogenic and high-temp accessories) |
| Temperature Accuracy | ±0.1 °C (traceable to NIST standards) |
| Heating/Cooling Rate | 0.1–100 K/min (programmable in 0.1 K/min increments) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DSC 8000 |
| Simultaneous Sample Capacity | Multiple |
| Instrument Type | Power-Compensated DSC |
| Temperature Range | –180 °C to 750 °C |
| Heating/Cooling Rate | 0.01 °C/min to 300 °C/min |
| Dynamic Heat Flow Range | ±800 mW |
| Furnace Material | Platinum-Iridium Alloy |
| Modulated DSC (MDSC®) | Standard |
| Cooling Options | Two-stage mechanical cooler, three-stage mechanical cooler, automated liquid nitrogen cooling |
| Dual Digital Mass Flow Controllers | Standard |
| Optional Accessories | 96-position autosampler, high-pressure cell (up to 600 psi), UV photo-DSC module, isolated sample chamber for hazardous materials |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Model | DSC 8500 |
| Temperature Range | –180 °C to 750 °C |
| Heating/Cooling Rate | up to 750 K/min (controlled), >1000 K/min (free cooling) |
| Heat Flow Dynamic Range | ±800 mW |
| Calorimetric Accuracy | < ±0.2% |
| Sensitivity | 0.18 µW |
| Data Acquisition Rate | up to 100 Hz |
| Standard Features | Dual-channel digital mass flow controllers, automated lid, integrated cooling accessory |
| Optional Accessories | 96-position autosampler, high-pressure DSC cell, isolated DSC module, photo-DSC unit, DSC–Raman hyphenated system |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TG-MS |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Pyris™ |
| Pricing | Available upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | STA 8000 |
| Pricing | Upon Request |
| Temperature Range | −150 °C to 1600 °C |
| Heating Rate | 0.01–100 °C/min |
| Temperature Stability | ±0.01 °C (at isothermal hold) |
| Maximum Sample Mass | 2 g (standard), up to 5 g (optional crucible) |
| Atmosphere Control | Dual-gas MFC with programmable switching (N₂, O₂, Ar, He, air, forming gas) |
| Balance Resolution | 0.1 µg |
| DSC Sensitivity | < 0.1 µW |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | STA6000 |
| Pricing | Upon Request |
| Heating Rate (°C/min) | Up to 100 |
| Temperature Range (°C) | −150 to 1500 |
| Temperature Stability | ±0.01 °C |
| Maximum Sample Weight (g) | 2000 |
| Atmosphere Control | Dual-gas MFC with Auto-Switching (Inert, Oxidizing, Reducing) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TG-GC/MS |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Manufacturer Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | TG-hiden MS |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TG-IR |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PerkinElmer TG-IR-GC/MS |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TGA 4000 |
| Temperature Range | Ambient to 1000 °C |
| Balance Capacity | 1500 mg |
| Balance Resolution | 0.2 µg |
| Balance Accuracy/Precision | ±0.02% / ±0.01% |
| Heating Rate | 0.1–200 °C/min |
| Temperature Accuracy/Precision | ±1 °C / ±0.8 °C |
| Sample Pan Volume | 180 µL |
| Atmosphere Options | Static or dynamic, including N₂, Ar, He, CO₂, air, O₂, and other inert or reactive gases |
| Integrated Mass Flow Controller | Standard |
| Optional Autosampler | 45-position |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TGA 8000 |
| Instrument Type | General-Purpose |
| Temperature Range | –20 °C to 1200 °C |
| Heating Rate | 0.1–500 °C/min |
| Gas Control | Dual-path mass flow control (balance purge + sample purge), optional 3-gas mixing module |
| Automation | 48-position autosampler with AccuPik™ compatibility |
| 联用接口 | Integrated heated divert valve and sniffer for FTIR/MS/GC-MS coupling |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TMA 4000 |
| Pricing | Available Upon Request |
| Brand | QKTester |
|---|---|
| Origin | Shandong, China |
| Manufacturer | QKTester |
| Model | XRPZ-02 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 10 °C/min |
| Temperature Accuracy | ±1 °C |
| Sample Length | 150–200 mm |
| Displacement Range | 0–5 mm (±2.5 mm) |
| Resolution | 0.0001 mm |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 3 kW |
| Dimensions | 800 × 690 × 1700 mm |
| Weight | 29 kg |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | DMC-196 |
| Measurement Mode | Isothermal Microcalorimetry |
| Instrument Type | Calvet-type Heat Flow Calorimeter |
| Key Features | Ultra-low temperature capability, high-sensitivity 3D thermopile sensor, dual-mode (DSC & IMC), high-pressure compatibility up to 350 bar |
| Temperature Range | −196 °C to 200 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Resolution | 0.1 µW (heat flow) |
| Temperature Scan Rate | 0.001–1 °C/min |
| Single-sample Test Duration | ~15 min |
| Calorimetric Cell Max Pressure Rating | 350 bar |
| Heat Capacity (typical) | ~10,500 J/K |
| Pressure Resolution | 0.1 µW (equivalent heat flow resolution under pressure coupling) |
| Outer Dewar Volume | Up to 12.5 mL |
| Inner Sample Cell Volume | Up to 12.5 mL |
| Peak-to-Peak Noise Level | 1 µW |
| Calorimetric Accuracy | ±0.1% |
| Calorimetric Precision | ±0.2% |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Calvet-type Microcalorimeter |
| Measurement Modes | Isothermal Microcalorimetry (IMC) & Differential Scanning Calorimetry (DSC) |
| Sample Capacity | Up to 12.5 mL |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy & Precision | ±0.1 °C |
| Temperature Scan Rate | 0.001–2 °C/min |
| Heat Flow Resolution | 0.1 μW |
| Baseline Noise (Peak-to-Peak) | ≤1 μW |
| Calorimetric Accuracy | ±0.2% |
| Calorimetric Precision | ±0.2% |
| Maximum Pressure Rating (High-Pressure Cell) | 100 MPa (1,000 bar) |
| Pressure Resolution | 350 bar (for integrated pressure tracking cells) |
| External Bath Volume | Up to 12.5 mL |
| Internal Bath Volume | 12.5 mL |
| Dimensions | 29 cm × 29 cm × 63 cm |
| Weight | 25 kg |
| Power Supply | 110–240 V, 50/60 Hz |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DSC-790 |
| Sample Capacity | Single |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | −150 °C to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| DSC Heat Flow Range | ±6000 mW |
| Cooling Options | Liquid Nitrogen, Mechanical, or Ambient Air |
| Heating Rate | 0.01–100 °C/min |
| Heat Flow Resolution | 0.1 µW |
| Calorimetric Accuracy | ±0.1% |
| Calorimetric Precision | ±0.1% |
| Atmosphere Control | Dual-gas inlet with software-driven automatic switching |
| Dimensions (W×D×H) | 950 mm × 555 mm × 360 mm |
| Weight | 30 kg |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Isothermal Microcalorimeter |
| Instrument Category | Cone Calorimeter (Note: *This is a misclassification in source data |
| Model | MIC-90 |
| Measurement Mode | Isothermal |
| Temperature Range | 3 °C to 95 °C |
| Temperature Stability | ±0.001 °C |
| Temperature Precision | ±0.15 °C |
| Single-Sample Measurement Time | ~15 min |
| Heat Capacity (System) | ~10,500 J/K |
| Outer Bath Volume | 25 mL |
| Inner Bath Volume | 25 mL |
| Channel Configurations | 3-channel or 8-channel swappable modules |
| Detection Limit | 2 μW (8-ch), 8 μW (3-ch) |
| Short-Term Noise | <1 μW (8-ch), <8 μW (3-ch) |
| Baseline Drift (24 h) | <5 μW (8-ch), <55 μW (3-ch) |
| Measurement Range | ±900 mW |
| Sample Cell Volume Options | 25 mL or 100 mL |
| Cell Materials | Borosilicate glass, stainless steel, or custom polymer |
| In-situ Mixing | Motorized stirrer with adjustable speed |
| Thermal Sensing Principle | Differential Seebeck-effect planar thermopile sensors |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Reaction Calorimeter |
| Automation Level | Fully Automated |
| Temperature Range (Reactor) | –25 °C to 200 °C |
| Temperature Range (Oil Bath) | –45 °C to 250 °C |
| Temperature Resolution | 1.0 mK |
| Temperature Control Precision | ±0.1 K |
| Calorimetric Methods | Heat-Flow, Power Compensation (optional), Reflux (optional) |
| Reactor Volume | 1000 mL (customizable) |
| Maximum Operating Pressure | 10 MPa |
| Stirring Speed | up to 2000 rpm |
| Torque | up to 75 N·cm |
| Oil Circulation Rate | 35–76 L/min |
| Calibration Heater | 0–50 VDC / 3.00 A / 120 W |
| Power Supply | 3×400 V / 50 Hz (±10%) / 20 A |
| Total System Power | 7000 W |
| Oil Bath Dimensions | 600 × 700 × 1300 mm |
| Oil Bath Weight | 210 kg |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Manufacturer |
| Model | STA-790 |
| Temperature Range | Ambient to 1300 °C / 1600 °C |
| Heating Rate | 0.01–50 °C/min |
| Thermogravimetric (TGA) Range | ±200 mg / ±1000 mg |
| TGA Resolution | 0.02 µg |
| DSC Resolution | 1 µW |
| Atmosphere Control | Dual independent mass-flow-controlled gas lines with software-programmable switching |
| Crucible Options | Al₂O₃, quartz, BN (optional) |
| Furnace Cooling | Integrated water-cooled furnace housing |
| Power Supply | 220 V, 50/60 Hz |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TGA-790 |
| Pricing | Upon Request |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 700 °C |
| Balance Sensitivity | ±0.01 µg |
| Temperature Calibration Method | Curie Point Reference |
| Heating/Cooling Rate | 0.01–50 °C/min |
| Mass Range | ±200 mg |
| Mass Resolution | ±0.02 µg |
| Atmosphere Control | Dual Independent Mass Flow Controllers (MFCs), Software-Programmable Gas Switching |
| Crucible Options | Alumina, Platinum |
| Furnace Cooling | Water-Cooled |
| Furnace Liner | Dust-Free Recirculating Cooling System |
| Power Supply | 220 V, 50/60 Hz |