- All
- Favorite
- Popular
- Most rated
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HFM11 |
| Instrument Category | Dose Rate / Contamination Meter |
| Instrument Type | Portable |
| Measurement Target | Human Hands and Feet |
| Detector Type | High-Performance Scintillation-Based Hand/Foot Probe Array |
| Measurement Mode | Surface Radioactive Contamination Screening |
| Sensitivity | High (optimized for low-level β/γ emitters, e.g., ⁹⁰Sr/⁹⁰Y, ¹³⁷Cs, ⁶⁰Co) |
| Compliance | IEC 61098:2017 (Radiation Protection Instrumentation — Hand and Foot Contamination Monitors) |
| Display | Large-area capacitive touchscreen LCD |
| Power Consumption | Low (<5 W standby, <12 W operational) |
| Data Storage | Internal non-volatile memory (≥10,000 measurement records with timestamp, operator ID, and location tag) |
| Calibration | Automated self-calibration routine with reference source verification |
| Optional Configuration | Integrated whole-body contamination probe module (for supplementary torso/leg screening) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | TruNarc |
| Spectral Range | 250 cm⁻¹ to 2875 cm⁻¹ |
| Spectral Resolution | 7–10.5 cm⁻¹ (FWHM, full spectral range) |
| Spatial Resolution | Not applicable (single-point probe geometry) |
| Minimum Wavenumber | 250 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.5 cm⁻¹ shift across three consecutive scans of identical sample under stable conditions |
| Weight | 570 g |
| Dimensions | 16.2 cm × 10.4 cm × 5.1 cm |
| Onboard Database | >60 controlled substances and illicit drugs |
| Data Output Formats | CSV, Excel (.xlsx), SPC, PDF |
| Battery Life | Up to 10 hours (rechargeable 3.7 V Li-ion pack) |
| Power Options | DC wall adapter (5 V, 1.5 A), optional vehicle charger |
| Operating Temperature | −10 °C to +50 °C |
| Interface Language | English, Simplified Chinese |
| Connectivity | Micro-USB to host PC |
| Software | TruNarc Management Software (Windows-compatible) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Confocal Micro-Raman Spectrometer |
| Model | DXR2xi |
| Spectral Range | 50–6000 cm⁻¹ |
| Spectral Resolution | <2 cm⁻¹ |
| Spatial Resolution | 500 nm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | Better than ±0.1 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | STRIDE |
| Instrument Category | Radiation Dose Rate Meter |
| Instrument Form Factor | Portable |
| Measured Medium | Radioactive Materials on Personnel or Vehicles |
| Detector Type | High-Sensitivity NaI(Tl) Scintillation Detector with Optional He-3 Neutron Detector and GM Tube |
| Measurement Mode | Portal-Based Screening |
| Nuclide Identification Time | 20–30 seconds (dependent on nuclide type, activity, background radiation level, and shielding) |
| Sensitivity | High |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | RadEye G-10 |
| Instrument Category | Dose Rate Meter |
| Form Factor | Portable |
| Radiation Types Measured | X-ray and Gamma (γ) |
| Detector Type | Energy-Compensated Geiger-Müller (GM) Tube |
| Measurement Range | 0.5 µSv/h to 100 mSv/h |
| Energy Response Range | 50 keV to 3 MeV |
| Sensitivity (¹³⁷Cs) | 1.7 cps per µSv/h |
| Compliance | ANSI N42.33-2021, NATO AEP-117 Ed.3 |
| Battery Life | Up to 600 hours on two AAA alkaline cells |
| Environmental Robustness | Vibration-resistant housing, IP65-rated enclosure |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported |
| Model | Thermo Scientific™ NanoDrop™ Ultra |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | RaptIR |
| Price Range | USD 42,000 – 70,000 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | Evolution 200 Series |
| Instrument Architecture | Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Selection |
| Spectral Bandwidth | Variable at 1 nm or 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 220 nm and 340 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye AB100 |
| Instrument Category | Dose Rate / Contamination Meter |
| Form Factor | Portable |
| Detector Type | Zinc-Loaded Plastic Scintillator |
| Active Detection Area | 69 mm × 145 mm (10,005 mm²) |
| Effective Sensitivity Area | 2500 px² (≈ 100 cm² equivalent in operational context) |
| Window Thickness | 0.87 mg/cm² aluminum-coated polymer foil |
| Alpha Efficiency (²⁴¹Am) | 36% |
| Beta Efficiency (⁶⁰Co) | 25% |
| Beta Efficiency (⁹⁰Sr/⁹⁰Y) | 49% |
| Gamma Response (¹³⁷Cs) | ~40 cps per µSv/h |
| Battery Life | Up to 1000 hours on NiMH rechargeable pack |
| Compliance | Meets ANSI N42.33, IEC 60846-1, and ISO 7503-1 for surface contamination monitoring |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific BioMate 3S |
| Optical Design | Double-Beam |
| Detector | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | <0.08% T |
| Automation | Automatic Wavelength Selection |
| Compliance | Meets pharmacopeial requirements (USP <857>, EP 2.2.25, JP 2.04) for routine quality control assays |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Evolution Pro |
| Instrument Configuration | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | Selectable 0.5, 1.0, 1.5, 2.0, or 4.0 nm |
| Wavelength Accuracy | ±0.20 nm at 546.07 nm (Hg emission line) |
| Wavelength Repeatability | Standard deviation <0.05 nm over 10 consecutive measurements |
| Stray Light | ≤0.4% T at 198 nm (KCl), ≤0.032% T at 220 nm (NaI), <0.01% T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NanoDrop Eight |
| Optical Design | Dual-beam |
| Detector | CCD Array |
| Wavelength Range | 190–850 nm |
| Wavelength Automation | Fully Automatic |
| Spectral Bandwidth | ≤1.8 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.01% T |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Genesys 30 |
| Optical Design | Single-Beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 325–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | <0.05% at 340 nm and 700 nm |
| Absorbance Range | ±3.0 A |
| Light Source | Tungsten Halogen Lamp |
| Display | 5-inch Full-Color TFT LCD |
| Data Export | USB Mass Storage Mode (TXT format) |
| Software | Onboard VISIONlite UI |
| Warranty | 3 Years Limited |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | picoSpin 45 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Form | Liquid Only |
| Sensitivity | ≥600:1 SNR for Single-Scan H₂O |
| Resolution | 2.25 Hz (measured on 1% ethylbenzene in CDCl₃) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | TruDefender FTX |
| Instrument Category | Fourier Transform Infrared (FTIR) |
| Form Factor | Portable |
| Wavenumber Range | 4,000–650 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Scan Speed | 1 spectrum per second |
| Signal-to-Noise Ratio | ≥1,000:1 (typical, 32 scans, ambient conditions) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | Niton XL2 Plus |
| Application | Handheld / Portable |
| Industry-Specific Use | Non-Ferrous Metals |
| Elemental Range | Mg to U |
| Quantification Range | ppm to 100% |
| Energy Resolution | 185 eV |
| Repeatability | ±10% |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Antaris Target In-Process Mixing Monitor |
| Instrument Category | Online Near-Infrared Spectrometer |
| Operating Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 5300–7500 cm⁻¹ |
| Scan Speed | 12.5 scans/second |
| Spectral Sampling Interval | 0.7 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | TQ Analyst |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Continuum |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | Niton FXL |
| Form Factor | Benchtop/Floor-Standing |
| Application Sector | Geological & Mining |
| Elemental Range | Na (11) – U (92) |
| Detection Limit | ppm-level |
| Energy Resolution | <145 eV at Mn Kα |
| Repeatability | ≥99% RSD (for certified reference materials under controlled conditions) |
| Weight | <14 kg |
| Dimensions (External) | 250 × 350 × 300 mm |
| Sample Chamber | 229 × 305 × 114 mm |
| Detector | Geometrically Optimized Large-area Drift Detector (GOLDD™) |
| Display | 9-inch adjustable-angle color touchscreen |
| Data Interface | USB 2.0 |
| Security | Password-protected user accounts with role-based access |
| Preloaded Modes | TestAll Geo (soil/mineral), TestAll (plastics/electronics/paint), Alloy, Precious Metals, RoHS, Environmental, Cement/Industrial Minerals |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Antaris MX |
| Instrument Type | Online/At-line Portable FT-NIR Analyzer |
| Principle | Fourier Transform Near-Infrared Spectroscopy (FT-NIR) with Real-time Process Integration |
| Wavelength Range | 4000–12000 cm⁻¹ |
| Scan Speed | 5 scans per second |
| Spectral Resolution | 2 cm⁻¹ (data sampling interval) |
| Measurement Modes | Transmission, Transflection, Diffuse Reflectance |
| Chemometrics Software | TQ Analyst v9+ and RESULT v3.x |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific MarqMetrix All-in-One Online Raman Spectrometer |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 100–3,250 cm⁻¹ |
| Spectral Resolution | 6.5 cm⁻¹ (average across full spectrum) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Evolution One |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Automation | Motorized Auto-Scanning |
| Spectral Bandwidth | 0.5–4 nm (selectable) |
| Wavelength Accuracy | ±0.5 nm (at Hg emission lines 541.9 nm and 546.1 nm), ±0.8 nm (full range) |
| Wavelength Repeatability | ≤0.05 nm (SD, 10 measurements at 546.1 nm Hg line) |
| Stray Light | <0.01% T (at 220 nm, NaI |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Nicolet iS20 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | Not specified (custom-configurable per application) |
| Spectral Resolution | 0.25 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 50,000:1 (at 4 cm⁻¹, 1 min scan, KBr beam splitter) |
| Wavenumber Accuracy | ±0.02 cm⁻¹ at 2000 cm⁻¹ |
| Optical Engine | LightDrive™ Interferometer Platform |
| Warranty | 10-year limited warranty on interferometer, laser, and IR source |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model Series | TLD 3500, TLD 5500, TLD 6600 |
| Instrument Class | Radiation Dosimetry Reader |
| Portability | Portable (TLD 3500), Benchtop Automated (TLD 5500), Fully Automated Floor-Standing System (TLD 6600) |
| Radiation Types Measured | Beta (β⁻), Photons (X-ray, γ), Neutrons (via converter foils) |
| Detector Compatibility | LiF:Mg,Ti (TLD-100), LiF:Mg,Cu,P (TLD-100H), CaF₂:Dy, CaSO₄:Dy, Al₂O₃:C (for OSL-compatible variants), and custom geometries (ribbons, rods, chips, powders) |
| Heating Method | Resistive (TLD 3500), Hot-Gas Convection (TLD 5500), Nitrogen-Heated Non-Contact (TLD 6600) |
| Max Heating Temperature | 600 °C |
| Readout Sensitivity | ≤1 µGy (LiF-based elements, typical) |
| Calibration Traceability | NIST-traceable, compliant with ANSI N13.11, N13.32, N545 |
| Software Platform | WinREMS v5.x (data acquisition, QA/QC logging, audit trail), WinAlgorithms v3.x (dose conversion per ICRP 74, ISO 4037, IEC 62387) |
Show next