| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | TruNarc |
| Spectral Range | 250 cm⁻¹ to 2875 cm⁻¹ |
| Spectral Resolution | 7–10.5 cm⁻¹ (FWHM, full spectral range) |
| Spatial Resolution | Not applicable (single-point probe geometry) |
| Minimum Wavenumber | 250 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.5 cm⁻¹ shift across three consecutive scans of identical sample under stable conditions |
| Weight | 570 g |
| Dimensions | 16.2 cm × 10.4 cm × 5.1 cm |
| Onboard Database | >60 controlled substances and illicit drugs |
| Data Output Formats | CSV, Excel (.xlsx), SPC, PDF |
| Battery Life | Up to 10 hours (rechargeable 3.7 V Li-ion pack) |
| Power Options | DC wall adapter (5 V, 1.5 A), optional vehicle charger |
| Operating Temperature | −10 °C to +50 °C |
| Interface Language | English, Simplified Chinese |
| Connectivity | Micro-USB to host PC |
| Software | TruNarc Management Software (Windows-compatible) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Confocal Micro-Raman Spectrometer |
| Model | DXR2xi |
| Spectral Range | 50–6000 cm⁻¹ |
| Spectral Resolution | <2 cm⁻¹ |
| Spatial Resolution | 500 nm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | Better than ±0.1 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported |
| Model | Thermo Scientific™ NanoDrop™ Ultra |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | Evolution 200 Series |
| Instrument Architecture | Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Selection |
| Spectral Bandwidth | Variable at 1 nm or 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 220 nm and 340 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific BioMate 3S |
| Optical Design | Double-Beam |
| Detector | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | <0.08% T |
| Automation | Automatic Wavelength Selection |
| Compliance | Meets pharmacopeial requirements (USP <857>, EP 2.2.25, JP 2.04) for routine quality control assays |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Evolution Pro |
| Instrument Configuration | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | Selectable 0.5, 1.0, 1.5, 2.0, or 4.0 nm |
| Wavelength Accuracy | ±0.20 nm at 546.07 nm (Hg emission line) |
| Wavelength Repeatability | Standard deviation <0.05 nm over 10 consecutive measurements |
| Stray Light | ≤0.4% T at 198 nm (KCl), ≤0.032% T at 220 nm (NaI), <0.01% T at 340 nm (NaNO₂) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NanoDrop Eight |
| Optical Design | Dual-beam |
| Detector | CCD Array |
| Wavelength Range | 190–850 nm |
| Wavelength Automation | Fully Automatic |
| Spectral Bandwidth | ≤1.8 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.01% T |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Genesys 30 |
| Optical Design | Single-Beam |
| Detector Type | Photodiode Array |
| Wavelength Range | 325–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | <0.05% at 340 nm and 700 nm |
| Absorbance Range | ±3.0 A |
| Light Source | Tungsten Halogen Lamp |
| Display | 5-inch Full-Color TFT LCD |
| Data Export | USB Mass Storage Mode (TXT format) |
| Software | Onboard VISIONlite UI |
| Warranty | 3 Years Limited |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | TruDefender FTX |
| Instrument Category | Fourier Transform Infrared (FTIR) |
| Form Factor | Portable |
| Wavenumber Range | 4,000–650 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Scan Speed | 1 spectrum per second |
| Signal-to-Noise Ratio | ≥1,000:1 (typical, 32 scans, ambient conditions) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Antaris Target In-Process Mixing Monitor |
| Instrument Category | Online Near-Infrared Spectrometer |
| Operating Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 5300–7500 cm⁻¹ |
| Scan Speed | 12.5 scans/second |
| Spectral Sampling Interval | 0.7 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | TQ Analyst |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Antaris MX |
| Instrument Type | Online/At-line Portable FT-NIR Analyzer |
| Principle | Fourier Transform Near-Infrared Spectroscopy (FT-NIR) with Real-time Process Integration |
| Wavelength Range | 4000–12000 cm⁻¹ |
| Scan Speed | 5 scans per second |
| Spectral Resolution | 2 cm⁻¹ (data sampling interval) |
| Measurement Modes | Transmission, Transflection, Diffuse Reflectance |
| Chemometrics Software | TQ Analyst v9+ and RESULT v3.x |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific MarqMetrix All-in-One Online Raman Spectrometer |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 100–3,250 cm⁻¹ |
| Spectral Resolution | 6.5 cm⁻¹ (average across full spectrum) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Evolution One |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Automation | Motorized Auto-Scanning |
| Spectral Bandwidth | 0.5–4 nm (selectable) |
| Wavelength Accuracy | ±0.5 nm (at Hg emission lines 541.9 nm and 546.1 nm), ±0.8 nm (full range) |
| Wavelength Repeatability | ≤0.05 nm (SD, 10 measurements at 546.1 nm Hg line) |
| Stray Light | <0.01% T (at 220 nm, NaI |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Nicolet iS20 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | Not specified (custom-configurable per application) |
| Spectral Resolution | 0.25 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 50,000:1 (at 4 cm⁻¹, 1 min scan, KBr beam splitter) |
| Wavenumber Accuracy | ±0.02 cm⁻¹ at 2000 cm⁻¹ |
| Optical Engine | LightDrive™ Interferometer Platform |
| Warranty | 10-year limited warranty on interferometer, laser, and IR source |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Biomate 160 |
| Instrument Architecture | Double-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet FT-SPR |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | microPHAZIR PC Plastics |
| Principle | Portable, On-Site NIR Spectroscopy |
| Spectral Range | 1600–2400 nm (6250–4100 cm⁻¹) |
| Measurement Time | <3 s |
| Sampling Mode | Diffuse Reflectance |
| Weight | 1.25 kg |
| Housing | High-Strength Dust-Resistant Polymer Enclosure |
| Light Source | Tungsten-Halogen Lamp |
| Data Storage | Internal Memory with USB Export |
| Interface | USB |
| Operating Temperature | 5–50 °C (non-condensing) |
| Power Supply | Dual Swappable Li-ion Batteries (4.5 h runtime), AC Adapter & Charger Included |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory FT-IR Spectrometer |
| Model | Summit |
| Instrument Type | Benchtop FT-IR |
| Wavenumber Range | 8,000–350 cm⁻¹ |
| Spectral Resolution | < 0.6 cm⁻¹ (optimizable to 0.4 cm⁻¹) |
| Signal-to-Noise Ratio | 45,000:1 (standard), up to 48,000:1 (optional) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ at 2,000 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported Dual-Beam UV-Vis Spectrophotometer |
| Model | GENESYS 40 |
| Optical Detector | Photodiode Array |
| Wavelength Range | 325–1100 nm |
| Wavelength Selection | Manual |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Handheld Raman Spectrometer |
| Model | 1064Defender |
| Spectral Range | 200–2500 cm⁻¹ |
| Spectral Resolution | 8–13 cm⁻¹ |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | ±0.1 cm⁻¹ |
| IP Rating | IP68 |
| Compliance | MIL-STD-810H |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Handheld Dual-Mode Spectrometer (Raman + FTIR) |
| Model | Gemini |
| Spectral Range (Raman) | 250–2875 cm⁻¹ |
| Spectral Resolution (Raman) | 7–10.5 cm⁻¹ (FWHM, full range) |
| Spectral Resolution (FTIR) | 4 cm⁻¹ |
| Minimum Wavenumber (Raman) | 250 cm⁻¹ |
| Minimum Wavenumber (FTIR) | 650 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.5 cm⁻¹ shift across three consecutive scans of identical sample under fixed acquisition conditions |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | DXR3xi |
| Instrument Category | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 350 nm |
| Excitation Wavelength | 455 nm (optional lasers available) |
| Spectral Reproducibility | ±0.1 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Imported |
| Model | GENESYS™ 140 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 325–1100 nm |
| Wavelength Scanning | Automatic |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.05% T at 340 nm and 400 nm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Niton Apollo LIBS |
| Instrument Category | Handheld |
| Integration | All-in-One |