Empowering Scientific Discovery

Thermo Fisher Scientific Molecular Spectroscopy Division

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Regional ClassificationDomestic
ModelEvolution 200 Series
Instrument ArchitectureDouble-Beam
Detector TypePhotodiode Array (PDA)
Wavelength Range190–1100 nm
Automation LevelAutomatic Wavelength Selection
Spectral BandwidthVariable at 1 nm or 2 nm
Wavelength Accuracy±0.5 nm
Stray Light<0.05% T at 220 nm and 340 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported Instrument
ModelThermo Scientific BioMate 3S
Optical DesignDouble-Beam
DetectorPhotodiode Array
Wavelength Range190–1100 nm
Wavelength Accuracy±1.0 nm
Spectral Bandwidth1.8 nm
Stray Light<0.08% T
AutomationAutomatic Wavelength Selection
ComplianceMeets pharmacopeial requirements (USP <857>, EP 2.2.25, JP 2.04) for routine quality control assays
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelEvolution Pro
Instrument ConfigurationDouble-beam
Detector TypePhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength ScanningMotorized Auto-Scanning
Spectral BandwidthSelectable 0.5, 1.0, 1.5, 2.0, or 4.0 nm
Wavelength Accuracy±0.20 nm at 546.07 nm (Hg emission line)
Wavelength RepeatabilityStandard deviation <0.05 nm over 10 consecutive measurements
Stray Light≤0.4% T at 198 nm (KCl), ≤0.032% T at 220 nm (NaI), <0.01% T at 340 nm (NaNO₂)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelNanoDrop Eight
Optical DesignDual-beam
DetectorCCD Array
Wavelength Range190–850 nm
Wavelength AutomationFully Automatic
Spectral Bandwidth≤1.8 nm
Wavelength Accuracy±1 nm
Stray Light≤0.01% T
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelGenesys 30
Optical DesignSingle-Beam
Detector TypePhotodiode Array
Wavelength Range325–1100 nm
Wavelength Accuracy±1.0 nm
Spectral Bandwidth5 nm
Stray Light<0.05% at 340 nm and 700 nm
Absorbance Range±3.0 A
Light SourceTungsten Halogen Lamp
Display5-inch Full-Color TFT LCD
Data ExportUSB Mass Storage Mode (TXT format)
SoftwareOnboard VISIONlite UI
Warranty3 Years Limited
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelEvolution One
Instrument ArchitectureDouble-beam
Detector TypePhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength AutomationMotorized Auto-Scanning
Spectral Bandwidth0.5–4 nm (selectable)
Wavelength Accuracy±0.5 nm (at Hg emission lines 541.9 nm and 546.1 nm), ±0.8 nm (full range)
Wavelength Repeatability≤0.05 nm (SD, 10 measurements at 546.1 nm Hg line)
Stray Light<0.01% T (at 220 nm, NaI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelBiomate 160
Instrument ArchitectureDouble-Beam
Detector TypePhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength SelectionManual
Spectral Bandwidth2 nm
Wavelength Accuracy±0.5 nm
Stray Light<1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Instrument TypeImported Dual-Beam UV-Vis Spectrophotometer
ModelGENESYS 40
Optical DetectorPhotodiode Array
Wavelength Range325–1100 nm
Wavelength SelectionManual
Spectral Bandwidth5 nm
Wavelength Accuracy±0.5 nm
Stray Light<0.05% T at 340 nm and 400 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Instrument TypeImported
ModelGENESYS™ 140
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range325–1100 nm
Wavelength ScanningAutomatic
Spectral Bandwidth5 nm
Wavelength Accuracy±0.5 nm
Stray Light<0.05% T at 340 nm and 400 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported Instrument
ModelNanoDrop 2000/2000c
Optical DesignDual-Beam
Sample Volume0.5–2.0 µL
Measurement Time<5 s (NanoDrop 2000), <3 s (NanoDrop 2000c cuvette mode)
Cuvette Temperature Control37 °C ±0.5 °C
Cuvette Stirring Speed150–850 rpm
Cuvette Dimensions12.5 mm × 12.5 mm × up to 48 mm
Pathlength Options10, 5, 2, and 1 mm
Absorbance Range (Cuvette Mode)0.008–1.5 AU
Base Unit Weight2.1 kg
ComplianceCE, FCC, RoHS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Instrument TypeImported
ModelGENESYS 180
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength SelectionManual
Spectral Bandwidth2 nm
Wavelength Accuracy±0.5 nm
Stray Light<1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported Instrument
ModelNanoDrop™ One/OneC
Optical DesignDual-beam
DetectorCCD (Charge-Coupled Device)
Wavelength Range190–850 nm
Wavelength AutomationFully Automatic
Spectral Bandwidth≤1.8 nm
Wavelength Accuracy±1.0 nm
Stray Light≤0.01% T
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Product TypeImported Instrument
ModelGENESYS 150
Optical DesignDouble-Beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength SelectionManual
Spectral Bandwidth2 nm
Wavelength Accuracy±0.5 nm
Stray Light<1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelEvolution One Plus
Instrument ArchitectureDouble-beam
Detector TypePhotodiode Array (PDA)
Wavelength Range190 nm to 1100 nm
Automation LevelAutomatic Wavelength Scanning
Spectral Bandwidth1.0 nm (fixed)
Wavelength Accuracy±0.5 nm (at Hg lines 541.9 nm and 546.1 nm), ±0.8 nm (full range 190–1100 nm)
Wavelength Repeatability≤0.05 nm (SD, n=10 at 546.1 nm Hg line)
Stray Light<0.01% T (i.e., >2 A at specified wavelengths)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelGenesys 10s
Instrument ArchitectureDouble-beam
Detector TypePhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Scanning SpeedUp to 4200 nm/min
Spectral Bandwidth1.8 nm
Wavelength Accuracy±0.3 nm
Stray Light<0.05% T at 220 nm and 340 nm
Light SourcePulsed Xenon Flash Lamp (3-year warranty)
GratingHolographic Master Grating
Cuvette ChangerIntegrated 6-position Auto-Changer
Data StorageUSB flash drive support
ComplianceDesigned to support USP <85>, EP 2.2.25, and JP 17 UV-Vis validation protocols
Software OptionsGENESYS Instrument Control Software (PC-based), optional FDA 21 CFR Part 11-compliant audit trail module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Instrument TypeImported
ModelEvolution 260
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.8 nm
Spectral Bandwidth1.0 nm and 2.0 nm
Stray Light≤1% T
AutomationMotorized Wavelength Selection
Light SourceXenon Flash Lamp
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Import StatusImported
ModelNanoDrop Lite Plus
Instrument ArchitectureDual-beam
Detector TypePhotodiode Array
Wavelength Range260–280 nm
Wavelength AutomationAutomatic
Spectral Bandwidth0.5 nm
Stray Light0.01% T
Key ApplicationsNucleic Acid & Protein Quantification, Purity Ratio Analysis (A260/A280, A260/A230)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher
OriginUSA
ManufacturerThermo Fisher Scientific
Instrument TypeImported Dual-Beam UV-Vis Spectrophotometer
ModelGENESYS 50
Optical DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.5 nm
Spectral Bandwidth2 nm
Stray Light<1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO₂)
AutomationAutomatic Wavelength Scanning & Calibration
Sample CompartmentRemovable, Washable Interior Liner
Display7-inch HD Touchscreen Interface
Method ManagementPre-programmed Smart Start Methods
CompatibilityCuvettes (10 mm pathlength standard), Test Tubes, Microvolume Adapters (optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandThermo Fisher Scientific
OriginUSA
ManufacturerYes
Import StatusImported
ModelSPECTRONIC 200
Instrument ArchitectureSingle-beam
Detector TypePhotodiode Array
Wavelength Range340 nm – 1000 nm
Wavelength ScanningMotorized Auto-wavelength Selection
Spectral Bandwidth< 4 nm
Wavelength Accuracy±1.0 nm (typical, per ASTM E275)
Stray Light< 0.1% T at 340 nm (as measured per ISO 9050)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0