- All
- Favorite
- Popular
- Most rated
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | TruDefender FTX |
| Instrument Category | Fourier Transform Infrared (FTIR) |
| Form Factor | Portable |
| Wavenumber Range | 4,000–650 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Scan Speed | 1 spectrum per second |
| Signal-to-Noise Ratio | ≥1,000:1 (typical, 32 scans, ambient conditions) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Nicolet iS20 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | Not specified (custom-configurable per application) |
| Spectral Resolution | 0.25 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 50,000:1 (at 4 cm⁻¹, 1 min scan, KBr beam splitter) |
| Wavenumber Accuracy | ±0.02 cm⁻¹ at 2000 cm⁻¹ |
| Optical Engine | LightDrive™ Interferometer Platform |
| Warranty | 10-year limited warranty on interferometer, laser, and IR source |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet FT-SPR |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory FT-IR Spectrometer |
| Model | Summit |
| Instrument Type | Benchtop FT-IR |
| Wavenumber Range | 8,000–350 cm⁻¹ |
| Spectral Resolution | < 0.6 cm⁻¹ (optimizable to 0.4 cm⁻¹) |
| Signal-to-Noise Ratio | 45,000:1 (standard), up to 48,000:1 (optional) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ at 2,000 cm⁻¹ |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nicolet iS10 |
| Instrument Type | Fourier Transform |
| Compliance Standards | ASTM E1421, NIST-traceable, USP <1119>, EP 2.2.24, JP 2.07, FDA 21 CFR Part 11 (with ValPro™ and OMNIC Security Suite) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TruDefender FT |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared Spectroscopy |
| Wavenumber Range | 4000–650 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Scan Speed | 2 scans/sec |
| Weight | 1.3 kg |
| Dimensions | 19.6 × 11.2 × 5.3 cm |
| Optical Interface | Diamond ATR Crystal |
| Environmental Rating | MIL-STD-810F & IP67 |
| Battery Life | >4 hours (rechargeable Li-ion or CR123A primary cells) |
| Operating Temperature | −25 °C to +40 °C |
| Data Export Formats | SPC, TXT, JPEG |
| Compliance | ASTM E2534 (for field-deployable chemical ID), GLP/GMP-ready audit trail support in firmware |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Nicolet iS50 |
| Instrument Type | Laboratory FT-IR Spectrometer |
| Wavenumber Range | 27,000–15 cm⁻¹ |
| Spectral Resolution | Better than 0.09 cm⁻¹ |
| Scan Speed | 0.158 cm/s (slow), 6.28 cm/s (fast) |
| Signal-to-Noise Ratio | >55,000:1 (1-minute acquisition) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Nicolet iS5 |
| Instrument Type | Laboratory FT-IR Spectrometer |
| Wavenumber Range | 350–7800 cm⁻¹ |
| Spectral Resolution | Better than 0.8 cm⁻¹ |
| Scan Speed | Up to 10 scans per second |
| Signal-to-Noise Ratio (SNR) | > 1 × 10⁵ (peak-to-peak, 4 cm⁻¹ resolution, 1 min scan) |