- All
- Favorite
- Popular
- Most rated
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HFM11 |
| Instrument Category | Dose Rate / Contamination Meter |
| Instrument Type | Portable |
| Measurement Target | Human Hands and Feet |
| Detector Type | High-Performance Scintillation-Based Hand/Foot Probe Array |
| Measurement Mode | Surface Radioactive Contamination Screening |
| Sensitivity | High (optimized for low-level β/γ emitters, e.g., ⁹⁰Sr/⁹⁰Y, ¹³⁷Cs, ⁶⁰Co) |
| Compliance | IEC 61098:2017 (Radiation Protection Instrumentation — Hand and Foot Contamination Monitors) |
| Display | Large-area capacitive touchscreen LCD |
| Power Consumption | Low (<5 W standby, <12 W operational) |
| Data Storage | Internal non-volatile memory (≥10,000 measurement records with timestamp, operator ID, and location tag) |
| Calibration | Automated self-calibration routine with reference source verification |
| Optional Configuration | Integrated whole-body contamination probe module (for supplementary torso/leg screening) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | STRIDE |
| Instrument Category | Radiation Dose Rate Meter |
| Instrument Form Factor | Portable |
| Measured Medium | Radioactive Materials on Personnel or Vehicles |
| Detector Type | High-Sensitivity NaI(Tl) Scintillation Detector with Optional He-3 Neutron Detector and GM Tube |
| Measurement Mode | Portal-Based Screening |
| Nuclide Identification Time | 20–30 seconds (dependent on nuclide type, activity, background radiation level, and shielding) |
| Sensitivity | High |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | RadEye G-10 |
| Instrument Category | Dose Rate Meter |
| Form Factor | Portable |
| Radiation Types Measured | X-ray and Gamma (γ) |
| Detector Type | Energy-Compensated Geiger-Müller (GM) Tube |
| Measurement Range | 0.5 µSv/h to 100 mSv/h |
| Energy Response Range | 50 keV to 3 MeV |
| Sensitivity (¹³⁷Cs) | 1.7 cps per µSv/h |
| Compliance | ANSI N42.33-2021, NATO AEP-117 Ed.3 |
| Battery Life | Up to 600 hours on two AAA alkaline cells |
| Environmental Robustness | Vibration-resistant housing, IP65-rated enclosure |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye AB100 |
| Instrument Category | Dose Rate / Contamination Meter |
| Form Factor | Portable |
| Detector Type | Zinc-Loaded Plastic Scintillator |
| Active Detection Area | 69 mm × 145 mm (10,005 mm²) |
| Effective Sensitivity Area | 2500 px² (≈ 100 cm² equivalent in operational context) |
| Window Thickness | 0.87 mg/cm² aluminum-coated polymer foil |
| Alpha Efficiency (²⁴¹Am) | 36% |
| Beta Efficiency (⁶⁰Co) | 25% |
| Beta Efficiency (⁹⁰Sr/⁹⁰Y) | 49% |
| Gamma Response (¹³⁷Cs) | ~40 cps per µSv/h |
| Battery Life | Up to 1000 hours on NiMH rechargeable pack |
| Compliance | Meets ANSI N42.33, IEC 60846-1, and ISO 7503-1 for surface contamination monitoring |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model Series | TLD 3500, TLD 5500, TLD 6600 |
| Instrument Class | Radiation Dosimetry Reader |
| Portability | Portable (TLD 3500), Benchtop Automated (TLD 5500), Fully Automated Floor-Standing System (TLD 6600) |
| Radiation Types Measured | Beta (β⁻), Photons (X-ray, γ), Neutrons (via converter foils) |
| Detector Compatibility | LiF:Mg,Ti (TLD-100), LiF:Mg,Cu,P (TLD-100H), CaF₂:Dy, CaSO₄:Dy, Al₂O₃:C (for OSL-compatible variants), and custom geometries (ribbons, rods, chips, powders) |
| Heating Method | Resistive (TLD 3500), Hot-Gas Convection (TLD 5500), Nitrogen-Heated Non-Contact (TLD 6600) |
| Max Heating Temperature | 600 °C |
| Readout Sensitivity | ≤1 µGy (LiF-based elements, typical) |
| Calibration Traceability | NIST-traceable, compliant with ANSI N13.11, N13.32, N545 |
| Software Platform | WinREMS v5.x (data acquisition, QA/QC logging, audit trail), WinAlgorithms v3.x (dose conversion per ICRP 74, ISO 4037, IEC 62387) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Thermoluminescent Dosimeter (TLD) Reader |
| Model | Harshaw TLD 6600 |
| Detector Type | TLD Reader |
| Radiation Types Measured | Photons (X-rays, γ-rays), Neutrons |
| Measurement Scope | Personal Dose, Environmental Dose |
| Linear Dose Range | Up to 20 Sv |
| Compliance | IEC 61066, ISO 14146, ANSI N13.32 |
| Operating Mode | Benchtop (not portable — corrected per technical specification) |
| Calibration | Automated, Traceable to NIST Standards |
| Quality Control | Built-in QC routines with pass/fail reporting |
| Light Sensitivity | Immune to ambient light interference (non-OSL design) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye NBR |
| Instrument Category | Radiation Survey Meter / Dose Rate Meter |
| Form Factor | Portable |
| Detection Target | Trace Artificial Gamma Emitters |
| Detector Type | Multi-Function NBR Probe (FHZ 674) |
| Measurement Range | 0.01 µSv/h – 100 µSv/h |
| Sensitivity | >1500 cps per µSv/h (at 30 keV) |
| Operating Temperature | −20 °C to +50 °C |
| Dimensions (RadEye SX) | 110 mm × 67 mm × 62 mm |
| Weight (RadEye SX only) | ~160 g (with 2×AA batteries and rubber boot) |
| Weight (FHZ 674 probe + SX) | ~2.8 kg (excluding shoulder strap) |
| Battery Life | ~150 h (with FHZ 674 probe, part #4250693) |
| Data Storage | 1500 measurement records + 250 operation logs |
| Alarm | Dual configurable thresholds (count rate / dose rate), audible alarm ≥80 dB at 30 cm |
| Probe Cable | RG58, up to 1.5 m, MHV connector |
| High Voltage Output | 100–1400 V, 2 MΩ load |
| Compatible Probes | 16 selectable probe types (configurable via HV, calibration factor, dead-time correction, overload threshold, and range) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TLD3500 |
| Instrument Class | Radiation Dose Meter |
| Instrument Form Factor | Portable |
| Detectable Radiation Types | Photons (E > 5 keV), Neutrons (thermal–100 MeV), Beta particles (E > 70 keV) |
| Measurement Quantities | Photon dose, neutron fluence, beta dose |
| Dose Range | 10 μGy – 1 Gy (linear response) |
| Sensitivity Threshold | < 1 kGy |
| Temperature Range | 15 °C – 600 °C |
| Heating Rate | 1–50 °C/s |
| Temperature Stability | ±1 °C |
| System Stability | ±0.005% |
| Operating Ambient | 15–40 °C |
| Output Units | nC, gU, mrad, mrem, mGy, Gy, µSv, mSv, Sv |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | MDS |
| Instrument Type | Portable Dose Rate Meter |
| Measurement Principle | Scintillation Detection & Neutron Proportional Counting |
| Detector Types | 5-L Plastic Scintillator (Primary), Optional He-3 Neutron Detector |
| Measurement Range | 1 nSv/h – 20 µSv/h |
| Sensitivity | 20,000 cps/µSv/h (for Cs-137) |
| Energy Response | 50 keV – 3 MeV |
| Background Count Rate | ~500 cps |
| Minimum Detectable Increase | ≥2 nSv/h above background |
| GPS | 6-Channel Satellite Receiver with Real-Time Georeferencing |
| Operating Temperature | −20 °C to +55 °C |
| Relative Humidity | 5–95% RH (non-condensing) |
| Power Supply | 12 V DC |
| Internal Battery | 8 h continuous operation |
| Enclosure | Zargus MIL-STD-810G Certified Transport Case |
| Weight | 15 kg |
| Dimensions (Detector Unit) | 40 × 60 × 35 cm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Models | SGS I, SGS II |
| Instrument Category | Dose Rate Meter / Radiation Survey Meter |
| Portability | Portable |
| Measured Radiation Types | Gamma (γ) and Neutron (n) |
| Detector Configuration | Dual plastic scintillator gamma detectors |
| Gamma Sensitivity | 500 cps/μR/h |
| Neutron Detection | He-3 proportional counter (3 atm) |
| Operating Temperature | –20 °C to +50 °C |
| Compliance | IAEA TS-G-1.2, ITRAP+10, ANSI N42.35-2019 |
| Data Storage | 1300 measurement records |
| Communication | RS-485 (to detectors), RS-232 (to PC) |
| Alarm Logic | Dual-threshold per channel, configurable alarm levels |
| Gamma Detector Volume (SGS I) | 50 L total (2 × 25 L) |
| Gamma Detector Volume (SGS II per 1500 GN unit) | 25 L |
| Neutron Detection Limit (SGS II, 10 s, 2 m, 252Cf) | 20,000 n/s |
| Gamma Detection Limit (SGS II) | <100 nSv/h (background 200 nSv/h) |
| Detection Probability | >99.9% |
| False Alarm Rate | <1 per 10,000 measurements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Mini 900 Series |
| Instrument Category | Dose Rate Meter / Radiation Survey Meter |
| Form Factor | Portable / Benchtop Configurable |
| Radiation Types Detected | X-ray and Gamma (γ) Radiation |
| Detector Options | Geiger-Müller (GM) Tube or Scintillation Detector |
| Measurement Principle | Pulse Counting / Analog Voltage Output Integration |
| Display Format | Logarithmic Scale with Simultaneous Background and Net Count Rate Readout |
| Alarm Function | User-Adjustable Threshold with Proportional Audio Feedback |
| Variants | R-Type (General Purpose), G-Type (Gamma-Optimized), D-Type (Dose Rate Calibrated), X-Type (X-Ray Enhanced) |
| Dimensions | 180 mm (W) × 110 mm (D) × 165 mm (H) |
| Weight | 1.0 kg |
| Power Supply | 6 × AA Alkaline or Rechargeable Batteries (Typical Runtime: ~300 hours at 4 hrs/day usage) |
| GM Tube Bias Voltage Range | 300–700 V DC |
| External Power Input | 12–18 V DC |
| High-Voltage Generator Output | 600–1500 V DC |
| Sensitivity | –100 mV negative polarity analog voltage input (for external detector interfacing) |
| Energy Response | Detector-dependent |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | TPM-903B |
| Instrument Category | Dose Rate Meter / Radiation Survey Meter |
| Instrument Type | Online, Real-Time Portal Monitor |
| Measured Medium | Gamma-emitting Radionuclides (e.g., Cs-137, Co-60) |
| Detector Type | Dual BC408 Plastic Scintillation Detectors |
| Detection Application | Rapid Personnel Screening & Emergency Radiological Incident Response |
| Sensitivity | ≤1 mCi RDA (Reference Dispersal Activity) for Cs-137 at 25 µR/h background, 1-second transit time |
| Shielding | Full-perimeter 1.6 mm lead lining |
| Transit Speed | One-second dwell time per individual |
| Operating Temperature | −20 °C to +50 °C |
| Portable Case Dimensions | 231 cm × 93 cm × 61 cm |
| Portable Case Weight | 40 kg |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | FH40G |
| Instrument Class | Dose Rate / Ambient Dose Equivalent Rate Meter |
| Form Factor | Portable |
| Measurable Radiation Types | X-ray, Gamma (γ), Neutron (n), Alpha (α), Beta (β) |
| Detector Types Supported | Scintillation, GM Tube, Ionization Chamber, Proportional Counter, He-3 Neutron Detector |
| Measurement Quantities | Ambient Dose Equivalent Rate H*(10), Personal Dose Equivalent Hₚ(10), Contamination (Bq/cm²), Count Rate (cps) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye PRD4 Portable High-Sensitivity Radiation Detector |
| Instrument Category | Dose/Dose Rate Meter |
| Form Factor | Portable |
| Measured Radiation | Gamma and Neutron |
| Detector Type | NaI(Tl) Scintillation Detector |
| Energy Range | 58 keV – 6 MeV (for dose and dose rate measurement) |
| Sensitivity | 200 cps per µSv/h |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Harshaw TLD |
| Instrument Category | Radiation Dosimetry / Dose Rate Meter |
| Form Factor | Personal/Environmental Wearable |
| Measured Radiation Types | Photons, Beta Particles, Thermal Neutrons, Fast Neutrons |
| Detector Material | LiF:Mg,Cu,P |
| LiF | Mg,Ti |
| Dosimetric Quantities | Hp(10), Hp(3), Hp(0.07), H*(10), H′(0.07), Neutron Fluence-to-Dose Conversion |
| Window Thickness | 3.3 mg/cm² (beta), 42 mg/cm² (photon), 7 mg/cm² (TLD-100/H/700H), 100 mg/cm² (TLD-100 for high-energy photon attenuation) |
| Element Dimensions | 3 mm × 0.4 mm (neutron-sensitive chips) |
| Compliance | ANSI N545-1993, ANSI N13.32-1995, ANSI N13.37 (draft), DOELAP, NVLAP-accredited testing protocols |
| Software | Integrated dose calculation software with ANSI/ISO traceable algorithms |
| Packaging | Hermetically sealed, barcoded, contamination-resistant encapsulation |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Dose Rate Meter |
| Model | FHT 40NBR |
| Detector Configuration | Dual-detector (NaI(Tl) scintillation crystal + plastic scintillator) |
| Measurement Principle | Gamma photon energy discrimination via pulse-height analysis and NBR (Natural Background Rejection) algorithm |
| Compliance | Designed for field-deployable radiological survey per IEC 60846-1:2014, ANSI N42.33, and EURATOM Directive 2013/59/Euratom |
| Data Interface | USB and Bluetooth® 4.0 |
| Storage Capacity | Up to 10,000 timestamped dose rate records |
| Operating Temperature | –10 °C to +50 °C |
| IP Rating | IP67 |
| Battery Life | >100 hours (alkaline) or >200 hours (rechargeable Li-ion) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye HEC |
| Instrument Category | Dose Rate / Activity Meter |
| Form Factor | Portable |
| Measured Radiation Types | Alpha and Beta Emitters |
| Detector Type | Scintillation Detector (Lu₂O₃-based) |
| Counting Range | Alpha: 1–10,000 cps |
| Beta | 1–100,000 cps |
| Background | Alpha <2 cpm, Beta <70 cpm (under 0.25 µSv/h gamma background) |
| Detector Diameter | 5 cm |
| Detection Efficiency (2π geometry, 50 mm source) | Pu-239 >85%, Am-241 >75%, Tc-99 >45%, Sr/Y-90 >70%, C-14 >20% |
| Sample Chamber Dimensions | 51.6 mm × 9.6 mm |
| Adjustable Sample Height | 3.2–7.9 mm |
| Data Storage | 250 system events (alarms/errors/parameter changes), 4500 full sample records |
| Calibration & Decay Correction | Built-in automated routines |
| Interface | Serial and USB |
| Regulatory Compliance | CE Marked |
| Internal Check Source | 9 g lutetium oxide (¹⁷⁶Lu) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Radiation and Contraband Detection System |
| Model | RadEye CD |
| Detector Type | RadEye SX with NaI(Tl) Scintillation Detector |
| Measurement Capability | Simultaneous detection of concealed contraband (e.g., tobacco, explosives, alcohol) and radioactive materials |
| Measurement Range | 5–10 cps (background), 50–100 cps (contraband presence) |
| Sensitivity | ≥5 cps minimum detectable signal above background |
| Analysis Channels | Dual-channel spectral analysis |
| Typical Background Count Rate | 5 cps |
| Effective Measurement Time | 1 second per acquisition |
| Regulatory Compliance | Designed for customs, border security, and port-of-entry applications in accordance with IAEA TS-G-1.2 and ANSI N42.34 standards |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | EPD-G |
| Instrument Category | Dose/Dose Rate Meter |
| Instrument Type | Portable |
| Measured Radiation | X-ray and Gamma (γ) Radiation |
| Detector Type | Multi-stage Solid-State Detector |
| Dose Equivalent Range | 1/64 µSv to 16 Sv |
| Dose Rate Range | 1/64 µSv/h to 16 Sv/h |
| Accuracy | ±10% (referenced to Cs-137, 662 keV) |
| Energy Response | 15 keV – 10 MeV |
| Power Supply | Two AA 1.5 V alkaline batteries (8 weeks continuous operation) or one 3.6 V lithium battery (5 months continuous operation) |
| Data Retention | 10 years without power |
| Memory Capacity | Adjustable logging interval down to 1 s |
| Security | Password-protected data storage area |
| Compliance | Designed for use in accordance with IEC 61526:2010 (Radiation protection instrumentation — Measurement of personal dose equivalents Hp(10) and Hp(0.07) for X, gamma, neutron and beta radiations) and meets requirements for routine occupational monitoring under ISO 4037 and ANSI N42.20 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | EPD-N2 |
| Instrument Category | Dose Rate Meter / Personal Dosimeter |
| Form Factor | Portable |
| Radiation Types Measured | Gamma and Neutron |
| Detector Technology | Multi-stage Solid-State Detector |
| Energy Range | 25 keV – 10 MeV (photons), Thermal neutrons – 15 MeV (neutrons) |
| Dose Quantity Displayed | Ambient and Personal Dose Equivalent Hp(10) |
| Compliance | IEC 61526 Ed. 4.0 (2018), ANSI N42.20, ISO 15265:2022 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RadEye B20 |
| Instrument Type | Portable Radiation Survey Meter |
| Radiation Types Detected | Alpha, Beta, Gamma, and X-ray |
| Detector Type | Thin-window Geiger-Müller (GM) Tube with 44 mm Active Diameter and Adjustable Window Thickness (1.8–20 mg/cm²) |
| Dose Rate Range (γ) | 0–2 mSv/h (RadEye B20) |
| Count Rate Range (Contamination) | 0–10 kcps (B20) |
| Energy Response (with γ energy window) | 17 keV – 3 MeV |
| 2π Detection Efficiency | ²⁴¹Am: 28%, ⁶⁰Co: 25%, ⁹⁰Sr/⁹⁰Y: 36%, ¹⁴C: 19% |
| Calibration Source | 9 g Lutetium Oxide (Lu₂O₃) reference source, activity density 50 Bq/g (1.4 nCi/g) |
| Alarm Modes | Audible, Visual (LED), and Vibratory |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Personal Radiation Detector (PRD) |
| Detector Type | NaI(Tl) Scintillation Crystal |
| Measurement Principle | Gamma Photon Detection via Scintillation & Pulse Height Analysis |
| Dose Rate Range | 0.01 µSv/h – 250 µSv/h (PRD mode) |
| Extended Range (PRD-ER) | 0.01 µSv/h – 100 mSv/h |
| Energy Response Range | 60 keV – 1.3 MeV |
| Sensitivity | 150 cps/(µSv/h) for ¹³⁷Cs |
| Data Storage Capacity | 1600 dose rate readings with timestamps |
| Ingress Protection Rating | IP65 |
| Operating Temperature | –10 °C to +50 °C |
| Battery Life | Up to 1,000 hours (typical alkaline battery operation) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | RadEye NL |
| Instrument Category | Neutron Dose Rate Meter |
| Form Factor | Portable |
| Detector Type | Pressurized He-3 Proportional Counter (2.5 bar) |
| Measurement Range | <0.2 cps (in presence of 10 mSv/h Cs-137 gamma field) |
| Neutron Sensitivity | −0.15 cps per μSv/h (calibrated to Cf-252 neutron source) |
| Background Count Rate | 0.0025 cps (at 300 m elevation) |
| Gamma Rejection Ratio | <0.2 cps for 10 mSv/h Cs-137 |
| Units Displayed | Counts per second (cps) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SAM12 |
| Instrument Category | Dose Rate / Contamination Meter |
| Instrument Form Factor | Portable |
| Detection Target | Gamma-emitting Radionuclides |
| Detector Technology | Co-60–Optimized Scintillation Detection with NBR (Natural Background Rejection) Algorithm |
| Measurement Scope | Discrimination of Artificial vs. Natural Gamma Radioactivity |
| Performance Context | High-reliability detection under elevated natural background radiation conditions |
| Sensitivity | Enhanced for low-level gamma contamination screening |
Show next