- All
- Favorite
- Popular
- Most rated
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | Niton XL2 Plus |
| Application | Handheld / Portable |
| Industry-Specific Use | Non-Ferrous Metals |
| Elemental Range | Mg to U |
| Quantification Range | ppm to 100% |
| Energy Resolution | 185 eV |
| Repeatability | ±10% |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | Niton FXL |
| Form Factor | Benchtop/Floor-Standing |
| Application Sector | Geological & Mining |
| Elemental Range | Na (11) – U (92) |
| Detection Limit | ppm-level |
| Energy Resolution | <145 eV at Mn Kα |
| Repeatability | ≥99% RSD (for certified reference materials under controlled conditions) |
| Weight | <14 kg |
| Dimensions (External) | 250 × 350 × 300 mm |
| Sample Chamber | 229 × 305 × 114 mm |
| Detector | Geometrically Optimized Large-area Drift Detector (GOLDD™) |
| Display | 9-inch adjustable-angle color touchscreen |
| Data Interface | USB 2.0 |
| Security | Password-protected user accounts with role-based access |
| Preloaded Modes | TestAll Geo (soil/mineral), TestAll (plastics/electronics/paint), Alloy, Precious Metals, RoHS, Environmental, Cement/Industrial Minerals |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | XL3t800 |
| Portability | Handheld/Portable |
| Weight | <1.3 kg |
| Dimensions | 244 × 230 × 95.5 mm (9.60 × 9.05 × 3.75 in) |
| X-ray Tube | High-performance micro-focus tube with Au anode (max 50 kV / 40 µA) |
| Detector | High-sensitivity Si-PIN semiconductor detector |
| Battery | Rechargeable Li-ion, >10 h operation per charge |
| Display | Adjustable-angle (0–90°) high-brightness VGA color touchscreen |
| Standard Elemental Range | Ti–U (23 elements: Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Zr, Nb, Mo, Pd, Ag, Sn, Hf, Ta, W, Re, Pb, Bi, Se, Sb) |
| Optional Helium Purge Kit | Enables Mg, Al, Si, P, S analysis |
| Data Storage | >10,000 spectra + results |
| Analysis Modes | Alloy Grade ID & quantitative composition, Grade Match, Super Quant, 3-mm spot mode (optional) |
| Connectivity | USB 2.0, Bluetooth 4.0 |
| Software | NITON Data Transfer (NDT) v8.x with PMI reporting, remote control, user permission management, audit trail, and CFR Part 11-compliant report generation |
| Safety | Radioisotope-free |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | XL3t 500 |
| Form Factor | Handheld / Portable |
| Detector Options | Si-PIN or High-Performance SDD with Peltier cooling |
| Excitation Source | Rhodium or Silver anode micro-X-ray tube (50 kV / 40 µA max) |
| Analyzable Elements | Mg–U (with He purge: Mg, Al, Si, P, S, Cl, K, Ca, and beyond) |
| Measurement Window | 8 mm or 3 mm (optional) |
| Display | Adjustable-angle VGA color touchscreen (0–90°) |
| Dimensions | 95.5 × 244 × 230 mm |
| Weight | <1.3 kg |
| Battery Life | Up to 10 hours (hot-swappable Li-ion with thermal management) |
| Data Storage | >10,000 spectra + results |
| Connectivity | USB, Bluetooth, RS-232 |
| Calibration Methods | Fundamental Parameters (FP) and empirical coefficient algorithms |
| Compliance | Meets IEC 61000-4 electromagnetic immunity standards |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Handheld EDXRF Analyzer |
| Model | Thermo Scientific Niton XL5 |
| Element Range | Mg (12) to U (92) |
| Detectable Elements | >30 common elements for alloy identification |
| Light Element Performance | Enhanced detection of low-Z elements (e.g., Mg, Al, Si, P, S) |
| Energy Resolution | 150–185 eV (FWHM, dependent on pulse processing time) |
| Weight | 1.3 kg (2.8 lbs) with battery |
| Dimensions | 242.6 × 208.2 × 67.9 mm (9.54 × 8.19 × 2.67 in) |
| X-ray Tube | Ag anode, 6–50 kV, up to 500 µA, max 5 W, dynamically adjustable current |
| Detector | Geometry-optimized large-area Silicon Drift Detector (GOLDD™), count rate up to 180,000 cps |
| Electronics | 800 MHz i.MX6 Quad-core ARM A9, 80 MHz ADC ASIC, 4096-channel MCA, 512 MB RAM / 4 GB industrial-grade flash storage |
| Display | Tilt-adjustable color touchscreen (glove-compatible) |
| Data Storage | >20,000 spectra (2 GB internal, ~100 kB/spectrum) |
| Connectivity | USB 2.0, Bluetooth 4.2, integrated GPS |
| Software | NitonConnect PC software, user-programmable menus, alloy mode with touch keyboard |
| Standard Accessories | Integrated CCD camera, rugged carrying case, dual Li-ion batteries, AC charger, USB cable, safety lanyard, calibration standards |
| Optional Accessories | 3-mm collimator, portable test stand, HotFoot thermal barrier, protective holster |
| Certifications | CE, RoHS, FCC, Industry Canada, IEC 61010-1:2010 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | XL2t |
| Application | Handheld / Portable |
| Industry-Specific Use | Non-Ferrous Metals |
| Elemental Range | Ti (22) to Bi (83), 25 elements |
| Concentration Range | 5 ppm – 99% |
| Energy Resolution | <185 eV |
| Repeatability | ±0.5% RSD |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Niton XL5 Plus XRF |
| Application | Handheld / Portable |
| Industry Use | General Purpose |
| Elemental Range | Mg–U (with ultra-low-light detection), Na (via spectral detection) |
| Analyzable Elements | >30 common elements |
| Primary Applications | Rapid alloy identification, ultra-trace light-element detection |
| Energy Resolution | 150–185 eV |
| Detector | High-count-rate, high-resolution, large-area silicon drift detector (SDD) with 1 µm graphene window and integrated detector protection |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | XL3t GOLDD+ |
| Application | Handheld / Portable |
| Industry Type | General Purpose |
| Elemental Range | Mg to S |
| Detection Limit | <10 ppm |
| Tube Voltage | 9–50 kV |
| Tube Current | 0–40 µA max |
| Repeatability | ±0.1% RSD |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | XL2 GOLDD |
| Application | Handheld / Portable |
| Industry-Specific Use | Geological & Mining |
| Elemental Range | Mg (12) to U (92), >30 elements |
| Quantification Range | 5 ppm – 99 wt% |
| Energy Resolution | <185 eV (at Mn Kα) |
| Repeatability | ≤0.5% RSD (for major elements under standardized conditions) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | XL3t700 |
| Portability | Handheld / Field-Deployable |
| Weight | <1.3 kg |
| Dimensions | 244 × 230 × 95.5 mm (9.60 × 9.05 × 3.75 in) |
| X-ray Tube | High-performance micro-focus tube with Au anode (max 50 kV / 40 µA) |
| Detector | High-resolution Si-PIN semiconductor detector |
| Battery | Rechargeable Li-ion, >10 h operation per charge |
| Display | Adjustable-angle VGA color touchscreen (0–90° tilt) |
| Standard Elemental Range | Ti–U |
| Optional Helium Purge Kit | Enables Mg, Al, Si, P, S, Ru detection |
| Data Storage | >10,000 spectra + metadata entries |
| Operating Modes | Metal, Plastic, Auto, Paint/Coating |
| Connectivity | USB 2.0, Bluetooth 4.0 |
| Software | NITON Data Transfer (NDT) v4.x with audit trail, user permissions, report customization, remote instrument control, and over-the-air firmware updates |
| Regulatory Compliance | Fully compliant with ASTM F2853, ASTM E1621, ISO 17025 (when used in accredited labs), CPSC Guidance for CPSIA Section 101, EU RoHS Directive 2011/65/EU Annex II, EN 71-3:2019, WEEE Directive 2012/19/EU |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | XL3t600 |
| Form Factor | Handheld / Portable |
| Excitation Source | High-Performance Microfocus X-ray Tube (Au anode) |
| Detector | High-Resolution Si-PIN Detector |
| Display | Adjustable 0–90° VGA Color Touchscreen |
| Battery | Third-Generation Hot-Swappable Rechargeable Li-ion |
| Analyzable Elements | Mg to U (depending on configuration) |
| Standard Mode | Soil Analysis Mode |
| Data Storage | >10,000 spectra + results |
| Connectivity | USB, Bluetooth 4.0, RS-232 |
| Safety | Password-Protected Access & Beam Interlock |
| Compliance | Meets EPA Method 6200 requirements for field screening |
Show next