| Brand | Drummond |
|---|---|
| Origin | USA |
| Model | Nanoject II Auto-Nanoliter Injector |
| Injection Volume Range | 2.3–69.0 nL |
| Filling Rate | 46 nL/s (fast), 23 nL/s (slow) |
| Injection Rate | 46 nL/s (fast), 23 nL/s (slow) |
| Emptying Rate | 230 nL/s (fast), 92 nL/s (slow) |
| Capillary Material | Borosilicate Glass, Softening Point: 780 °C |
| Included Accessories | 200 borosilicate glass capillaries, maintenance kit, foot switch, universal adapter (3-000-024-A) |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CellTram |
| Pricing | Contact Authorized Distributor |
| Brand | Eppendorf |
|---|---|
| Origin | Germany |
| Model | Eporator |
| Voltage Range | 200–2500 V |
| Pulse Duration | 5 ms |
| Capacitance | 10 µF |
| Resistance | 600 Ω |
| Pulse Waveform | Exponential Decay |
| Dimensions (W×D×H) | 19 × 27.5 × 12.5 cm |
| Weight | 3.2 kg |
| Power Supply | 100–240 V, 50–60 Hz |
| Interface | USB 2.0 |
| Brand | Etta Biotech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | X-Porator F1 |
| Price Range | USD 110,000 – 138,000 (FOB) |
| High-Voltage Range | 30–600 VDC |
| Low-Voltage Range | 30–600 VDC |
| Output Waveform | Square Wave |
| Cell Processing Volume | 3–250 mL per run |
| Cell Capacity | 1.5×10⁷–1.0×10¹⁰ viable eukaryotic cells per run |
| Recommended Cell Density | 1×10⁸ cells/mL |
| Compatible Vessels | Corning 15 mL, 50 mL, and 250 mL conical centrifuge tubes |
| Flow Rate | 1–50 mL/min |
| Input Voltage | 210–240 VAC |
| Operating System | Embedded Linux |
| Dimensions (W×D×H) | 623 × 452 × 325 mm |
| Weight | 28 kg |
| Brand | Etta Biotech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | X-Porator H1 |
| High-Voltage Range | 30–600 VDC |
| Low-Voltage Range | 30–600 VDC |
| Output Waveform | Square Wave |
| Cell Throughput | 3–250 mL per run |
| Recommended Cell Density | 1 × 10⁸ cells/mL |
| Compatible Vessels | Corning 15 mL, 50 mL, and 250 mL centrifuge tubes |
| Flow Rate | 1–50 mL/min |
| Input Voltage | 210–240 VAC |
| Control Software | X-Porator F1 (Linux-based) |
| Dimensions (W × D × H) | 623 × 452 × 325 mm |
| Weight | 28 kg |
| Brand | Etta Biotech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | X-Porator M1 |
| Output Waveform | Square Wave |
| Brand | WPI (World Precision Instruments) |
|---|---|
| Model | EVOM3 |
| Origin | USA |
| Type | Epithelial/Endothelial Transepithelial Electrical Resistance (TEER) Measurement System |
| Measurement Principle | AC-based impedance spectroscopy with constant-current excitation (40 Hz, 2–10 µA) |
| Display | 7-inch capacitive touchscreen |
| Data Output | USB-stored CSV files with timestamped TEER (Ω·cm²), voltage (mV), and temperature (°C) |
| Current Ranges | 2 µA, 4 µA, 10 µA (user-selectable fixed-current mode) |
| Resistance Range | 1 Ω to 100 kΩ (auto-ranging or fixed-range optimized for barrier integrity assays) |
| Resolution | 0.1 Ω at 200 Ω |
| Compliance | Designed for GLP-compliant in vitro barrier function studies |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BTX 384L |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | BTX Electrofusion Electrodes |
| Voltage Range | 0–500 V DC (Microslides), 0–480 V DC / 0–16 V AC (Meander & Flat Chambers) |
| Pulse Duration | 1 µs – 99 ms |
| Pulse Count | 1–99 |
| Electrode Gaps | 0.2 mm (Meander), 0.5 / 1.0 / 3.2 / 10.0 mm (Microslides), 1.0 mm (Flat Chamber) |
| Field Uniformity | Non-uniform (Microslides, Meander, Flat in fusion mode), Uniform (Flat in electroporation mode) |
| Sample Volume Capacity | 20–2200 µL (Microslides), 5–20 µL (Meander), 500 µL (Flat Chamber) |
| Compatible Systems | ECM830, ECM2001 |
| Reusability | Yes (with mild cleaning) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model Variants | 450, 450-1, 453, 453-10 |
| Voltage Range | 0–500 VDC |
| Pulse Duration | 1 µs – 99 ms |
| Pulse Count | 1–99 |
| Electrode Gap Options | 0.5 mm, 1.0 mm, 3.2 mm, 10 mm |
| Sample Volume Capacity | 20 µL – 2.2 mL |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 20–80% |
| Altitude Limit | ≤2000 m |
| Insulation Category | CAT I |
| Pollution Degree | II |
| Autoclavable | No |
| Compatible Generators | ECM® 2001, ECM 630, 830, 395, 399, 600, T820 |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BTX Model 524 |
| Pricing | Upon Request |
| Electrode Type | Reusable bipolar tweezer-style electroporation electrode |
| Length | 11.5 cm |
| Adjustable Inter-electrode Gap | Up to 20 mm |
| Electrode Disk Diameter Options | 7 mm (Part #45-0118) or 10 mm (Part #45-0119) |
| Electrode Material | Stainless steel disk electrodes with integrated anode indicator |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | BTX Specialized Electroporation Electrodes |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PP35-2P |
| Type | Adherent-cell-specific electroporation electrode |
| Compatibility | Standard 35 mm Petri dishes with 2 mm gap electrodes |
| Application | In situ transfection of monolayer-cultured mammalian cells |
| Configuration | Dual parallel plate electrode assembly |
| Brand | NanoEnTek |
|---|---|
| Origin | South Korea |
| Model | ExTransfection |
| Type | Benchtop Microchannel Electroporator |
| Application Focus | High-Efficiency Nucleic Acid and RNP Delivery to Primary Cells, Stem Cells, and Immune Cells |
| Key | Brand: Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PP35-2P |
| Distribution Type | Authorized Distributor |
| Import Status | Imported |
| Pricing | Upon Request |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GP-3000 |
| High-Voltage Range | 400–2500 V |
| Low-Voltage Range | 50–450 V |
| Capacitance Options | 1, 5, 6, 25, 30, 31 µF |
| Resistance Settings | 30 discrete steps (50, 100, 150, 1600 Ω, and ∞) |
| Pulse Decay Profile | Exponential decay |
| Brand | SCILOGEX (SCIENTZ) |
|---|---|
| Model | SCIENTZ-2CS |
| Origin | Zhejiang, China |
| Manufacturer | SCILOGEX Instrument Co., Ltd. |
| Type | Benchtop Capacitance-Variable Electroporator |
| High-Voltage Range | 400–2500 V |
| Low-Voltage Range | 50–450 V |
| Capacitance Options | 1, 5, 6, 25, 30, 31 µF |
| Resistance Settings | 30 discrete values (50, 100, 150, 1600 Ω, and open-circuit/∞) |
| Pulse Decay Profile | Exponential decay |
| Compliance | CE-marked |
| Sample Compatibility | Standard 0.1 cm, 0.2 cm, and 1.0 cm electroporation cuvettes (not included) |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-97 |
| Type | Horizontal Programmable Micropipette Puller |
| Heating Mechanism | Dual-Independent Filament (Tungsten/Platinum) |
| Control Architecture | Microprocessor-Based with Ramp Detection Algorithm |
| Program Storage | 100 User-Defined Protocols with Write-Protection and Timestamping |
| Electrode Symmetry | Dual-Output Symmetric Pulling |
| Tip Diameter Reproducibility | Sub-100 nm (verified by SEM) |
| Integrated Gas System | Regulated Compressed Air with Particulate Filter, Desiccant Dryer, and Humidity Stabilization |
| Display | Vacuum Fluorescent Display (VFD) with Real-Time Parameter Monitoring |
| Compliance | Designed for GLP/GMP-aligned electrophysiology workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CTS Xenon |
| High Voltage Range | 2500 V |
| Low Voltage Range | 500 V |
| Pulse Count | 1–10 |
| Pulse Duration | 1–30 ms |
| Output Waveform | Square Wave |